Tender For 1) Replacement/Installation Of Led Luminaries, Ceiling Fan, Exhaust Fan & Other Electrical Accessories At Observation Home For Boy-I Delhi Gate, New Delhi. 2) Supply Installation Testing and Commissioning of 125 Kva & 50 Kva Servo Voltage
Tender Overview
Project Description
Tender for 1) Replacement/Installation Of Led Luminaries, Ceiling Fan, Exhaust Fan & Other Electrical Accessories At Observation Home For Boy-I Delhi Gate, New Delhi. 2) Supply Installation Testing and Commissioning of 125 Kva & 50 Kva Servo Voltage Stabilizer With Accessories At Observation Home For Boys At Delhi Gate. (Sh: Provision Of Wiring Acs And Other Electrical Accessories)
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.1.01) Group C |
| 2 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). a) 4 way (4 + 12), Double door |
| 3 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. (a) Group C |
| 4 | Supplying and drawing of following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit etc as required.a) 3 x 1.5 sq. mm |
| 5 | b) 3 x 4 sq. mm |
| 6 | c) 3 x 6 sq. mm |
| 7 | d) 6 x 4 sq. mm |
| 8 | Supplying and fixing of PVC cable management system / wall trunking with cover of following sizes including internal, external, flat single cover and T- cover , end cap and other accessories on the wall so as to make complete etc as required. a) 100 mmx50mm |
| 9 | b) 50 mm X 50mm |
| 10 | Supplying and fixing of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. a) 3 Module (100 mmX75 mm) |
| 11 | b) 6 Module (150 mmX75 mm) |
| 12 | c) 8 Module (125 mmX125 mm) |
| 13 | d) 12 Module (200 mmX150 mm) |
| 14 | Supplying and fixing of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etcas required.a) 5/6 Ampers switch |
| 15 | b) 15/16 Ampers switch |
| 16 | c) 3 pin 5/6 Ampers socket outlet |
| 17 | d) 6 pin 15/16 A socket outlet |
| 18 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. a) 12 way (4 + 36), Double door |
| 19 | Supply, Installation, Testing and Commissioning of 100kg organic fully automatic (PLC based) kitchen food wastage, paper wastage Composter Machine including heaters, sensors, temperature controller, Manual, automatic Feeding to shredder, overload and current protection for motors and blowers, Aerobic Thermophilicbased Bacteria, odor control, Enriched and dry Condition and state of output compost, no harmful gases, suitable for removing composte once in 24 hours, SS 304 shaft, blades, body of machine should be made of SS, Fibre/MS with grade A epoxy coating, Specification confirms as per Solid waste management rules 2016 including including 20 nos. standard manure collection bags, transfer tray having 10-20 KG capacity and all accessories etc as required for smooth operation of the system as per site condition including suitable cement concrete foundation with 1 year free of cost complete comprehensive maintenance etc. complete as reqd. |
| 20 | Supplying and fixing of 5 Ampers to 32 Ampers rating, 240/415 Volts, 10 kA, breaking capacity “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as requireda) Single pole |
| 21 | b) Single pole and neutral |
| 22 | Supplying, laying and fixing of following sizes XLPE insulated PVC sheathed aluminum conductor armoured cable of 1.1 KV grade on surface etc complete as required.a) 3.5 X 70 Sq.mm |
| 23 | b) 4 X 25 Sq.mm |
| 24 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only12.01) 2.0 TR with 5 Star BEE Rating |
| 25 | Supplying and fixing of M.S. outdoor, floor/ wall mounting powder coated stand suitable for 1.5/2.0 Ton capacity split/tower type A.C. outdoor unit complete as required. |
| 26 | Supplying, installation, testing and commissioning of 5 KVA (170v-270v), copper wounded, wall mounted voltage stabilizer with LED display, surge indicator, automatic reset complete etc. as required. |
| 27 | Providing &Laying of refrigerant copper piping of size 1/4\\" or 3/8\\" & 5/8\\" diameter from indoor unit to outdoor unit of split type Air Conditioner unit along with 4 core 2.5 sq.mm PVC insulated and PVC sheathed flexible copper conductor cable including 20 mm size of cotton thread ribbed PVC flexible pipe from drip tray of Air Conditioner unit to drain pipe along with necessary support complete etc all as per Direction of Engineer-in-charge. |
| 28 | Supplying & Drawing of 3x4 sqmm size of PVC insulated &pvc sheathed copper conductor round multicore flexible cable for indoor to outdoor and upto nearest power point i/c providing suitable copper lugs connection etc as required. |
| 29 | Providing & fixing of 25 mm dia (Schedule-1) UPVC/heavy duty PVC white colour drain pipe of with necessary fitting such as nipple, reducer, clamp on surface / recess i/c cutting the wall and making good the same complete as required. |
| 30 | Supplying, installation, testing & commissioning of 450mm sweep size metal body Oscillating type wall fan of with fan regulator and fixing with the help of dash fasteners including connections etc as required. |
| 31 | LED DisplaySupplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with3840x2160 resolution or better, USB playback, Bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+,brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V):170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc.as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender