Tender For The Work Of Furnishing Of New Office At Kalpetta In Wayanad District.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Nov 2026
6 days left
EMD
27400
Bank guarantee accepted
Document Fee
2600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Wayanad → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for The Work Of Furnishing Of New Office At Kalpetta In Wayanad District.
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Secretary, Kerala Khadi and Village Industries Board, Vanchiyoor, Thiruvananthapuram Name of Work: The Work of Furnishing of New Office at Kalpetta in Wayanad District. Contract No: KB.6988/2026/Engg. Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Details of Work Item Code / Make Quantity Unit Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | APPENDIX-A |
| 3 | Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. : - Hot finished welded type tubes ( D S R 10.16.1 ) |
| 4 | Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling , partition etc. complete (frame work to be paid seperatately). 8 MM thick Cement fiber board as per IS: 14862 ( D S R 12.26.1 ) |
| 5 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: Gypusm Plaster Board of size 1200 x 2400 x 12.5 mm, with all 4 side tapered ( D S R 2016 12.45.1. ) |
| 6 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. ( D S R 13.26 ) |
| 7 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer ( D S R 13.43.1 ) |
| 8 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. ( D S R 13.61.1 . ) |
| 9 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : One or more coats on old work ( 2018 D S R 13.98.1 ) |
| 10 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : One or more coats on old work. ( D S R 13.99.1 ) |
| 11 | Finishing walls with Acrylic Smooth exterior paint of required shade: Old work (Two or more coats applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface ( D S R 13.111.1 ) |
| 12 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade ( D S R 8.2.2.2. ) Area of slab over 0.50 sqm |
| 13 | Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall ( Observed Data Buildings 50.18.7.4.2. ) |
| 14 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.63 mm dia 4 Kgf/cm2 ( OD BUILDINGS 50.18.9.7.2 ) |
| 15 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow |
| 16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ( D S R 18.53.1 ) 15mm nominal bore |
| 17 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore |
| 18 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. ( DSR 2018 , 8.5 ) |
| 19 | 17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required 17.10.2 Kitchen sink without drain board - 610x510 mm bowl depth 200 mm ( DSR 2018 17.10.2.1 ) |
| 20 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, For all leads including all lifts involved. ( D S R 2016 15.60 ) |
| 21 | Engaging Labour For Cleaning works / Repair Works - Beldar |
| 22 | Engaging Labour For Cleaning works / Repair Works - FITTER GRADE 2 |
| 23 | Providing and Fixing Office Table size 120 x 60 x , height 75 cm using Prelaminated particle board with one side decorative and other side balancing lamination, flat pressed 3 layer & graded (medium density) Grade I, Type II conforming to IS : 12823 (exterior grade) 18 mm thick , including 1 no of Key Board Drawyer, 1 no of Cupboard and 1 no of Table Drawyer, making the frame work using 25 x 25 mm thick teak wood reepers and steel screws, providing the CPU STAND USING 16 MM THICK BWR GRADE ( IS 303 ) PLYWOOD, Fixing 40 x 40 mm Teak Wood Moulded beeding ( Ornamental Type ) for the Table Edge, fixing 2nd class teak wood lipping/ moulded beading of size 18X12 mm fixed with wooden adhesive of approved quality and screws/nails on all the edges of the Pre-laminated particle board/ Ply wood,, Providing Suitable Foot Rest Using Teak Wood Scandling Of SIze 100 x 50 mm, Providing 1 no Telescopic key board runner, 1 no of Drawyer runner, suitable hinges for cupboard, Locks, Handles ( All of Ebco or Aproved Quality ) , including Finishing With all Painting and Polishing work all as per the approved Drawing and as directed by the Engineer in Charge |
| 24 | Providing and Fixing Project Officer Table / VIO TABLE of size 150 x 80 cm , height 80 cm , using Prelaminated particle board with one side decorative and other side balancing lamination, flat pressed 3 layer & graded (medium density) Grade I, Type II conforming to IS : 12823 (exterior grade) 18 mm thick , including 1 no of Key Board Drawyer, 1 no of Cupboard and 1 no of Table Drawyer, making the frame work using 25 x 25 mm thick teak wood reepers and steel screws, providing the CPU STAND USING 16 MM THICK BWR GRADE ( IS 303 ) PLYWOOD, Fixing 40 x 40 mm Teak Wood Moulded beeding ( Ornamental Type ) for the Table Edge, Providing Suitable Foot Rest Using Teak Wood Scandling Of SIze 100 x 50 mm, Providing 1 no Telescopic key board runner, 1 no of Drawyer runner, suitable hinges for cupboard, Locks, Handles ( All of Ebco or Aproved Quality ) , including Finishing With all Painting and Polishing work all as per the approved Drawing and as directed by the Engineer in Charge |
| 25 | Supplying fabricating and erecting in position FILE STORAGE RACK of1.20 M x 1.20 M x 0.40 M by using 12mm / 16 mm / 18 mm thick commercial ply wood board conforming to IS : 303 BWR Grade , 16 mm thick 4 nos for vertical members, 18 mm thick 4 racks horizontal and 12 mm thick for back covring ,Providing 16 mm thick Shutters using piano hinges,providing II ND CLASS TEAK WOOD Lipping to all edges of the ply wood and corners, all Exposed surface should be covered with 1 mm thick approved quality Decorative Laminated sheets using suitable addhessive ( Heatex or Equivalent ) , All Internal surface painted with 2 coat of Synthetic Enamel over a coat of primer after sealing all the holes and joints using putty , providing approved quality Cup board Locks and Handles etc. complete all as per the approved drawings and direction of the Engineer in charge. . ( Only one Phase area of File Storage Rack may be meassured for payment ) |
| 26 | Providing and Fixing Office Partition made out of FRAME work using 16 mm BWR QUALITY ( IS 303 grade ) plywood at suitable spacing both horizontally and vertically, Commercial plywood 16 mm thick B W R grade ( IS 303 Grade ) of approved make is fixed on Both side of the frame work with screws of necessary size fixing the partition to wall/ floor including making hole in the concrete / masonry wall with necessary S S Hold Fasts, L Clamps or SS screws of necessary size, Providing Teak wood beading of of size 50 x 20 mm on all the exposed edges of the partition , Providing surface covered by suitable thickness Decorative Laminated Sheets with Texture Finish using suitable adhesive ( Heatex or Equivalent ) including sealing all the joints and holes all as per the approved drawings and Direction of the Engineer in Charge . ( Only one Phase area of each partition may be meassured for payment ) |
| 27 | Providing and Fixing plywood Back ground panel made out of FRAME work using 16 mm BWR QUALITY ( IS 303 grade ) plywood at suitable spacing both horizontally and vertically, including making hole in the concrete/ masonry wall, with necessary SS hold fasts or SS screws of necessary size. Then Commercial plywood 12 mm thick B W R grade ( IS 303 Grade ) of approved make is fixed to the Exposed side of the frame work with screws of necessary size , all the exposed surface covered by 1.00mm thickness Decorative Laminated Sheets with suitable adhesive ( Heatex or Equivalent ) including sealing all the joints and holes all as per the approved drawings and Direction of the Engineer in Charge . |
| 28 | Providing M S DISPLAY RACKS in Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding grinding and bolted with special shaped washers etc. complete. Hot finished welded type tubes ( D S R 10.16.1 ) |
| 29 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. GROUP B ( D S R ELECTRICAL 1.10.2 ) |
| 30 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required ( DSR Eectrical 2018, 1.55.3 ) |
| 31 | Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. ( OD ELECTRICAL 90.4.8 ) |
| 32 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 MM ( D S R ELECTRICAL 1.21.1 ) |
| 33 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 MM ( D S R ELECTRICAL 1.21.2 ) |
| 34 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X 1.5 sq.mm ( D S R ELECTRICAL 1.17.3 ) |
| 35 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm ( D S R ELECTRICAL 1.17.12 ) |
| 36 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 4 sq. mm ( D S R ELECTRICAL 1.17.21 ) |
| 37 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) ( D S R ELECTRICAL 1.27.1 ) |
| 38 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm) ( D S R ELECTRICAL 1.27.2 ) |
| 39 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 4 Module ( 125 mm X 75 mm ) ( D S R ELECTRICAL 1.27.3 ) |
| 40 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 6 Module ( 200 mm X 75 mm ) ( D S R ELECTRICAL 1.27.4 ) |
| 41 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 8 Module ( 125 mm X 125 mm ) ( D S R ELECTRICAL 1.27.5 ) |
| 42 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm) ( D S R ELECTRICAL 1.27.6 ) |
| 43 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch ( D S R ELECTRICAL 1.24.1 ) |
| 44 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch ( D S R ELECTRICAL 1.24.3 ) |
| 45 | Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 32A DP switch with indicator ( OD Electrical 90.10.3.15 ) |
| 46 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet ( D S R ELECTRICAL 1.24.4 ) |
| 47 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet ( D S R ELECTRICAL 1.24.5 ) |
| 48 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. ( D S R ELECTRICAL 1.26 ) |
| 49 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings) ( DSR Electrical 1.31 ) |
| 50 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) ( DSR Electrical 2.4.5 ) |
| 51 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole ( D S R ELECTRICAL 2.10.1 ) |
| 52 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required ( D S R ELECTRICAL 2.11 ) |
| 53 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. ( 40 Amps ) ( D S R 2.12. 1 ) |
| 54 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. ( 63 Amps ) ( D S R 2.12. 1 ) |
| 55 | Supplying and fixing following rating, 2 pole, ( Single Phase and Neutral ) 240 volts, residual current circuit breaker ( RCCB) having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps ( D S R ELECTRICAL 2.14.2 ) |
| 56 | Supplying and fixing following rating, 2 pole, ( Single Phase and Neutral ) 240 volts, residual current circuit breaker ( RCCB) having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps ( D S R ELECTRICAL 2.14.3 ) |
| 57 | Supply , conveyance, installation, testing and commissioning Wall mounting fan of 400 mm Sweep with Oscillation system and Pull Cord, using mounting brackets supplied along with the fan and giving connection with existing wire. |
| 58 | Supply, conveyance installation testing and commissioning of Sleek Compact Recess Mounting LED Slim Panel light fitting 18 W , square or round, Cool or Warm , size 205 mm ( or nearest available size ) with light Weight Body, energy efficient drive ,complete with all accessories , fixing directly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required. |
| 59 | Supply, conveyance installation testing and commissioning of Sleek Compact Recess Mounting LED Slim Panel light fitting 12 W , square or round, Cool or Warm , size 155 mm ( or nearest available size ) with light Weight Body, energy efficient drive ,complete with all accessories , fixing directly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required. |
| 60 | Supply, conveyance installation testing and commissioning of Sleek Compact Recess Mounting LED Slim Panel light fitting 6 W , square or round, Cool or Warm , size 105 mm ( or nearest available ) with light Weight Body, energy efficient drive ,complete with all accessories , fixing directly on ceiling including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring etc. as required. |
| 61 | SUPPLY AND FIXING 250 MM EXHAUST FAN WITH NECESSARY FITTINGS ( od15434/2021_2022 ) |
| 62 | Supplying and drawing RJ 45 Data Cable ( CAT 6 4 PAIR LAN CABLE ) in the existing surface or recessed PVC conduits as required |
| 63 | Supplying and fixing following modular switch/socket on the existing modular plate and switch box including connections etc as required. RJ 45 Socket ( Legrand Mylinc or Equivalent Brand ) od179147/2023_2024 |
| 64 | SUPPLY AND FIXING 1200 MM BATTEN LED LIGHT 20 WATTS WITH ALL NECESSARY FITTINGS od2332/2026_2027 |
| 65 | Engaging Labor for Electrical works including repair or maintenance works as directed by the Engineer in charge , Wire Man od2335/2026_2027 |
| 66 | Supply and installation of suitable size MS fan clamp with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required. ( OD ELECTRICALS 90.4.2 ) |
| 67 | Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C ( OD ELECTRICAL 90.4.5.2. ) |
| 68 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. ( D S R ELECTRICAL 1.25 ) Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender