Public Administrative Department Local Bodies Closing in 5 days TDR #58292314

Tender For Provision Of Lighting Arrangement In Vidya Devi Park-Pandav Nagar, Near Wz-414-Narayana Village, Opp. Dda Flat-67A-Tc C -Pandav Nagar, Apna Park-Nearest To Union Bank-Narayana Vihar, Near Wz-572-Club-Narayana Vihar, In Mcd School-Pandav Na

Issued by Local Bodies · New Delhi, Delhi
Tender Value
15.16 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
5 days left
EMD
30650
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of Lighting Arrangement In Vidya Devi Park-Pandav Nagar, Near Wz-414-Narayana Village, Opp. Dda Flat-67A-Tc C -Pandav Nagar, Apna Park-Nearest To Union Bank-Narayana Vihar, Near Wz-572-Club-Narayana Vihar, In Mcd School-Pandav Nagar And Narayana Vihar In Ward No. 139 (Ac-39) Under Karol Bagh Zone.

BOQ

Name of Work:- Provision of Lighting arrangement in Vidya Devi Park-Pandav Nagar, Near WZ-414-Narayana Village, Opp. DDA Flat-67A-TC C -Pandav Nagar, Apna Park-Nearest to Union Bank-Narayana Vihar, Near WZ-572-Club-Narayana Vihar, In MCD School-Pandav Nagar and Narayana Vihar in Ward No. 139 (AC-39) under Karol Bagh Zone.
Sl. No. Item Description
1Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
2Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
3Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (without charcoal/ coke and salt) as required
4Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
5Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
6Fabrication, Supplying, Installation, testing, Commissioning of 12 metres semi high mast System with its accessorles Mast shaft shall be in one section, hot dip galvanized 4mm thick(Single dip) Inside & out sides & suitable for wind velocity as per IS 875 part .There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For semi High Mast head frame ,2 point suspension system ,5 X 2.5 sqmm Copper conductor with steel wire rope 5mm dia. (7/19 construction) single drum winch galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminaries symmetrically and its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the semi high mast considering the safe soil bearing capacity at site as 10 T/sqm at 2 mts. Depth with all material i/c 4 Nos. S.P MCB, 1 No. Double pole 16 Amp. MCB etc as reqd. Logo/Name .of manufacturer shall be either embossed or Rivited plate on the pole. galvanization as per relevant IS.
7Fabrication, supply & erection of 4.0 mtr height, minimum 3 mm thick, bottom dia of 130 mm & top dia of 70mm, base plate of size 225 x 225 x 12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplylng and fixing of 6 mm thick laminated mounted sheet inside the window and i/c providing and welding 3 nos. Gl strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor - 4 nos. & shorting links on DIN channel i/c providing and flxing DIN channel of suitable length, 6 Amp. SPMCB 'C' Curve characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be either embossed or Rivited plate on the pole Galvanization as per relevant IS code etc as required.
8Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm(L) x 450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -960mm long (approx.) - 8 nos. and reinforcement of cold twisted bar of 8 mm dia - 1400 mm (approx.) - 6 nos. (with 150 mm spacing) as required with supplying and positioning of 4 nos foundation bolts size 16 mm dia, 600mm long, J type i/c 2 nos template anchor plates of size 225 mm x 225 mm x 3 mm and providing DWC HDPE pipe for cable entry & exit as required for 3 m and 5 mtr pole.
9Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 3 x 1.5 sq. mm
10LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3- 2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). -45 Watt.
11Fabrication supplying and fixing Class B Galvanised Single overhang arm bracket made out of 250 mm long galvanized top tube with cap & 1000 mm long 32 mm dia galvanized pipe with tightening bolts complete as reqd.
12Providing and fixing of stainless steal name plate of size 6x8 sq inch made of 20 guage sheet including engraved name of arae repersentative duly painted along with SS clamp nut bolt etc. as required.
13Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
14Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc as reqd.
15Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.lKV grade conforming to IS- 7098 of following size:- (a) 2x6 sqmm
16DSR Civil 2018 110.10:Providing and fiving name board made of MS Sheet 90x60cm, 1mm thick with frame of MS angle 50x50x6mm, two diagonal braces at the back of the sheet of MS flat 40x6mm, total height of the board above ground level 2.40m, length of legs below ground 0.30m embedded in CC block 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) 30x30x45cm including excavation and removal of surplus earth with in 50m lead, applying priming coat of approved steel primer, painting with synthetic enamel paint of approved quality and lettering with enamel paint of approved colour (one side) as per drawing/direction of Engineer-in-Charge.
17LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy >135 lm/Watt)-Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg 120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)- 100 Watt Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58292314
AUTHORITY Local Bodies
TENDER VALUE 15.16 Lakhs
LAST DATE 09-11-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Provision Of Lighting Arrangement In Vidya Devi Park-Pandav Nagar, Near Wz-414-Narayana Village, Opp. Dda Flat-67A-Tc C -Pandav Nagar, Apna Park-Nearest To Union Bank-Narayana Vihar, Near Wz-572-Club-Narayana Vihar, In Mcd School-Pandav Nagar And Narayana Vihar In Ward No. 139 (Ac-39) Under Karol Bagh Zone.
Basic Detail
Tender No NIT No 41/EEE/KBZ/MCD/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 30 Oct 2026
Submission Date 09 Nov 2026
Open Date 09 Nov 2026
Finance
Tender Value 15.16 Lakhs
Tender Fee 590
EMD 30650
Exemption Not Available
Document List
b7470e1c-79ee-4cd4-87fa-b5abfd2aef79.html
BOQ_345461.xls
ConditionNarayana.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

b7470e1c-79ee-4cd4-87fa-b5abfd2aef79.html

xls

BOQ_345461.xls

pdf

ConditionNarayana.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender