Educational and Research Institute Boards / Undertakings / PSU Closing in 21 days TDR #58292078

Tender For Electrical Maintenance Works In Substations 3&4 And Replacement Of Old Panel Board In A Hostel Kiosk At Nitc C Us

Issued by Boards / Undertakings / PSU · Kozhikode, Kerala
Tender Value
6.50 Lakhs
Estimated cost
Bid Submission
20 Nov 2026
21 days left
EMD
13000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kozhikode → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Electrical Maintenance Works In Substations 3&4 And Replacement Of Old Panel Board In A Hostel Kiosk At Nitc C Us

BOQ

Name of Work:- Electrical Maintenance Works in Substations 3&4 and Replacement of Old Panel Board in A Hostel Kiosk at NITC C us
Sl. No. Item Description
1Supply, Installation, Testing and Commissioning (SITC) of ( C&S CSDPR-V2-300-C2 or ASHIDA ADR241S or its equivalent) self-powered numerical protection relay or equivalent for Over Current, Earth Fault and Short Circuit protection, suitable for the existing 11 kV Lucy make MCR type 2-way RMU panel, including removal of the existing C&S CSDPR-V2-300-C2 RMU protection relay, necessary modifications, wiring, termination, interfacing with the existing tripping mechanism, programming and setting of protection parameters, testing and commissioning, and all other necessary accessories, materials, labour and works required for complete installation and commissioning as per site conditions.(Site Visit Recomended)
2Supply, Installation, Testing and Commissioning of CB Front Fascia Plate suitable for existing Lucy Make RMU, MCR Type 2-Way, Serial No. 1001938, including necessary fixing accessories, hardware and minor modifications required for proper installation and satisfactory completion of the work.(Site Visit Recomended)
3Servicing of existing 11 kV Lucy Make MCR Type CB operating mechanism, including cleaning, degreasing, lubrication of moving parts, checking and testing of the spring charging mechanism, and necessary adjustments for proper and satisfactory operation.(Site Visit Recomended)
4Servicing of existing Under Voltage Relay (UVR) in Lucy Make MCR Type RMU panel, including inspection, cleaning, checking of relay operation, functional trip test, time-delay verification, necessary adjustments and testing for proper and satisfactory operation.(Site Visit Recomended)
5Supply,Installation,testing and commissioning of RMU trip coil 24 Volt for CB mechanism(lucy or it equivalent), in the existing Lucy make MCR type (Site Visit Recomended)
6Removal of existing C&S IRI-Pro 3I-EI protection relay from the existing 11 kV Lucy Make MCR Type panel, and reinstallation of the same relay in another existing 11 kV RMU panel after removal of the existing CG Make protection relay, including necessary mounting, panel modifications, wiring, termination, interconnection, programming/setting, testing and commissioning, along with all required accessories, materials, labour and minor modifications required for satisfactory operation. (Site visit is recommended).
7Supply, Installation, Testing and Commissioning of L&T MRP11 Reverse Power Relay in the existing panel board, including removal of the existing faulty relay, necessary mounting, wiring, termination, programming/setting, testing and commissioning, complete with all required accessories and minor modifications as required at site.(Site visit recomended)
8Replacement of existing faulty Auxiliary Switch, 8NO + 8NC, in the existing 11 kV VCB panel, including dismantling and removal of the existing faulty auxiliary switch, supply, installation, Testing and commisioning of new auxiliary switch, necessary wiring, termination, ferruling, testing and commissioning, complete in all respects.(L&T orRishabh or its Equivalent) (Site visit recomended)
9Replacement of existing faulty VCB spring charging motor limit switch assembly in Megawin make VCB, Type MHVCB, 12 kV, 600 A, 25 kA short-circuit breaking current, rated voltage, manufactured in 2004, including supply, installation, testing and commissioning, complete in all respects.(Site visit recomended)
10Replacemnt of existing TNC breaker control switch 32A/660VAC/DC, pistol grip handle, switch on 11 kV VCB panel (L&T orRishabh or its Equivalent)(Site visit is recommended).
11Removal of the existing panel board and Supply, Installation, Testing and Commissioning (SITC) of a new cubicle-type, dust- and vermin-proof, wall-mounted, front-operated indoor LT panel board, fabricated from 2 mm thick CRCA sheet steel, complete with concealed hinges, neoprene gasket, panel locks and all necessary accessories. The entire sheet steel work shall be treated through a seven-tank process and powder-coated with Siemens Grey matt finish.The panel shall comprise 1 No. 630 A, 4-Pole, 36 kA MCCB incomer and 3 Nos. 400 A, 4-Pole, 36 kA MCCB outgoing feeders, with suitably rated copper busbars. R-Y-B phase indication with control MCB, and multifunction metering for the incomer and outgoing feeders, 4 Nos. in total, with RS-485 communication facility suitable for integration with the Energy Management System (EMS), complete with suitable size CTs(included). CT test reports issued by KSEB or an approved testing agency shall be submitted.The work shall include dismantling and removal of the existing panel board, shifting of dismantled materials to the designated location, necessary reconnection of existing cables, internal wiring, control wiring, terminals, supports, labelling, earthing and all other necessary materials and accessories required for complete installation.(Site visit is recommended).
12Supply for High Purity, Mineral-Free Water (100% TDS and PH Tested) demineralised water designed for topping up lead-acid secondary storage batteries.(Exide or its equivalent)
13Supplying and making end termination with brass compression gland and aluminium 3.5C x 400 sq.mm size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1KV grade as required Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58292078
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 6.50 Lakhs
LAST DATE 20-11-2026
Authority
Authority Name National Institute Of Technology
Work Description Tender for Electrical Maintenance Works In Substations 3&4 And Replacement Of Old Panel Board In A Hostel Kiosk At Nitc C Us
Basic Detail
Tender No Engg/EMU/EMU JE 3/0038/MAINTENANCE AT SS3 and 4
Bidding Type Tender
Location
City Kozhikode
State Kerala
Key Dates
Publish Date 30 Oct 2026
Submission Date 20 Nov 2026
Open Date 23 Nov 2026
Finance
Tender Value 6.50 Lakhs
Tender Fee Ref. Documents
EMD 13000
Exemption Available
Document List
49510aed-55fd-4557-b58a-d92f4d127535.html
BOQ_979893.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 30, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Nov 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Nov 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
html

49510aed-55fd-4557-b58a-d92f4d127535.html

xls

BOQ_979893.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender