Tender For Provision Of Squad Post (Open Class Room With Galvalume Sheet Shed) For 604And 626 Garud Flts
Tender Overview
Project Description
Tender for Provision Of Squad Post (Open Class Room With Galvalume Sheet Shed) For 604And 626 Garud Flts
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | M & L Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Hard/Dense Soil. |
| 2 | M & L Add to item 01 for each additional 1.5m or part thereof in depth beyond the first 1.5 m Hard/Dense Soil. |
| 3 | M&L Cement concrete in foundations, filling and mass concrete type D-2 1:4:8 (40mm graded aggregate) |
| 4 | M&L Reinforced cement concrete type B1, 1:2:4, using 20mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete |
| 5 | M&L Reinforced cement concretetype B1, 1:2:4, using 20mm graded aggregate) Columns, pillars, piers, posts and struts |
| 6 | M&L Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm |
| 7 | M&L Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed |
| 8 | M&L Formwork flat to sides of concrete foundations, footings, bases of columns, and plinth beams and similar work vertical or to batter |
| 9 | M&L Formwork flat to to sides of pillars, posts, struts, piers, columns and stanchions |
| 10 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 11 | Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders |
| 12 | M&L pre-cast cement concrete masonary in PCC 1:3:6 type C1 using 20mm graded aggregate with solid block, exceeding 10cm in width setting in CM 1:6 complete. |
| 13 | M&L for rendering 15mm thick cement plaster in CM 1 :4 on concrete surfaces of roof slab and parapets mixed with WPC @ 4ml per kg by weight of cement shall be carried out all as specified and directed by the Engineer-in-Charge ( WPC shall be measured and paid separetely) |
| 14 | Supply only Liquid water proofing compound |
| 15 | M&L Filling under floors or in foundations including watering and consolidation |
| 16 | M&L Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 10cm thick, watered and rammed to a true surface |
| 17 | M&L 100mm thick PCC, 1:4:8 Type D-2 |
| 18 | M & L for Cement concrete 40mm thick type B-1, 1:2:4 (20mm graded aggregate) Finishing cement concrete surface even and smooth without using extra cement |
| 19 | M&L Three coats of white wash on internal wall surfaces including preparations above skirting/Dado |
| 20 | S & F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment Fe-410- W(Gde-E-250) quality-B |
| 21 | S & F for steel work in Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc Fe-410- W(Gde-E-250) quality-B |
| 22 | S & F for steel work in Roof trusses in a Curved Shape (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe-290 Gde E-165 |
| 23 | Preparation of new or previously untreated steel surfaces & applying a two coats of synthetic enamel paint over a coat of red oxide primer over 10cm in width or girth,not otherwise described. |
| 24 | S & F for steel work in Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 |
| 25 | S & F Pre- painted galvalume (Curved Shape) aluminum zinc coating GI based corrugated Curved steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 26 | S & F Pre-painted galvalum aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 27 | M&L M&L for PCC 1:3:6, type C2, (Using 40 mm graded stone aggregate), 100mm thick as in plinth protection/Sub base flooring, finishing surface fair and even, in panels & filling joints with mortar, etc., complete all as specified and directed. |
| 28 | Surface dressing n exc 15 cm deep and getting out Hard/Dense soil. |
| 29 | Excavating over areas not exc 1.50m deep and getting out in Hard/Dense soil. |
| 30 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed. |
| 31 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. |
| 32 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; |
| 33 | Wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade concealed ISI marked incl accessories incl GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium/heylam plat, iron screws , housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for the following :- (a) One light point controlled by one switch Note for Item No 33 to 35:-(i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. |
| 34 | (b) One 3 pin socket out let 5 Amps on independent board |
| 35 | (c) one 3 pin socket out let 5 A on same board |
| 36 | S&F LED batten suitable for indoor applications 18/20 Watts, 4 feet with extruded aluminium housing & integrated LED channel rectangular white acrylic cover complete with all accessories all as specified and directed. |
| 37 | S&F for modular switch , flush type single pole, one way 5/6 Amps, 230 Volts complete all as specified and directed by Engr-In-Charge. |
| 38 | S&F for modular socket , single pole, one way 5/6 Amps, 230 Volts complete all as specified and directed by Engr-In-Charge. |
| 39 | S&F MCB SPN 240 volts 40 Amps complete all as specified and as directed |
| 40 | S&F MCB single pole 240 volts 6 to 32 Amps complete all as specified and as directed |
| 41 | S&F MCB DB SPN 4 way double door type 240 volts with 200 Amps rated bushbar as specified and as directed. |
| 42 | S&F ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed. |
| 43 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed. |
| 44 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 45 | S&F of Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer GI bracket from bldg complete all as specified and directed. |
| 46 | M& L Excavation in trenches in soft/loose soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed. |
| 47 | M&L for removing excavated surplus soil to a distance exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as directed. |
| 48 | M&L for sand cushioning with a layer of river sand 23 cm thick under and above the cable complete all as specified and as directed. |
| 49 | Supply and lay sub class 'B' old size bricks,designation 75 laid in trenches for protection of cables all as directed. |
| 50 | S&F XLPE insulated, screeened, PVC bedded, galvanised steel strip or wire armoured power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area16 sqmm, 4 core laid in trenches/wall. |
| 51 | Supply and laying in repairs galvanised iron steel tube, light grade, with all fittings fixed complete on walls, poles, laid under floors or in trenches as cable protection works (including necessary clamps, bolts, nuts, etc.,) as specified for 32 mm bore pipe |
| 52 | Supply, install,testing & Commisioning of LT feeder pillar box/panel board/out door type, made out of MS sheet 3.15 mm thick duly powder coated, dust and vermin proof and angle iron frame of size 40x40x6 mm mounted on angle iron bracket (40x40x6mm) ie, 15cm below groung level and 15cm above ground level with suitable foundation/ platform for mounting the panel, 3 phase, 4 wire, 440 Volts, AC, 50 HZ with TPN aluminium bus bar of capacity 400 A with PVC insulated heat shrink colour code sleeves, mounted horizontaly with porcelain insulators, sufficient air vent provision for all the three sides, stickers / plastic plates for switch gear details complete with voltmeter 0-500 volts Ammeter 0-50Amps with CTS & selector switches, back to fuse, indicating lamps with toggle switches duly wired including, CBET locking arrngement and comprising of the following items. (a) Incomming MCCB 63 Amps, 4 pole, 25 KA, 415 volts- 01 No (b) Outgoing MCB SPN 20 Amps- 02 Nos (c) Amp Meter, Volt Meter and indicator set (RYB) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 6 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender