Educational and Research Institute Boards / Undertakings / PSU Closing in 4 days TDR #58289122

Tender For Civil And Electrical Renovation Of Orc Suits Rooms No:111,112 And Proposed New Suit Room At Nit Warangal.

Issued by Boards / Undertakings / PSU · Warangal Urban, Telangana
Tender Value
12.33 Lakhs
Estimated cost
Bid Submission
27 Nov 2026
4 days left
EMD
24700
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Warangal Urban → Telangana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Civil And Electrical Renovation Of Orc Suits Rooms No:111,112 And Proposed New Suit Room At Nit Warangal.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 20-Nov-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-Nov-2026

BOQ

Name of Work:- Civil and Electrical renovation of ORC Suits rooms no:111,112 and proposed new suit room at NIT Warangal.
Sl. No. Item Description
1Providing new wooden wall cladding using 12 mm thick moisture resistant plywood and aluminum frames and a 6 mm thck decorative surface panel of smooth finish with polishing as per the instructions of Engineer in charge.
2Providing and fixing 12 mm thick perforated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineering-charge. Pre-laminated particle board with decorative lamination on both sides
3Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.0 mm thickness (weight not less than 12.50kg/sqm)
4Providing and fixing aluminium hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
5Providing and fixing aluminium tower bolts, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm
6Providing and fixing aluminium handles, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm
7Providing and fixing ISI marked aluminium butt hinges anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 100x63x3.2 mm
8Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm
9Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge.
10Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. each 1025.65
11Supplying and fixing of Unplasticized Poly Vinyl Chloride (UPVC) 3 track sliding doors with mesh shutter – (2-glass shutters and 1-mesh shutter)- 95 - Series duly manufactured using UPVC reinforced profiles (Composition of profile shall consists a minimum of 5.5 PHR of TiO2 and not more than 12 PHR of CaCo3 for every 100 parts of PVC resin) of (108 mm x 45 mm)/(95.50 mm x 60 mm) x 2.20 mm for outer frames, (75 mm x 39 mm)/(66 mm x 42 mm) x 2.20 mm for sliding door shutter frames capable of mounting single glazing system, structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.2 mm prefabricated & welded through fusion welding the door sash shall be fitted with 6 mm thick clear float glass of reputed make duly fixed with Grey colour TPV Gasket for sash & Glazing bead shall be coextruded with Grey colour soft PVC.
12Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
13Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.
14Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand)
1512 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
16Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
17Supplying and fixng of nahany trap of 4''(100mm) dia for washroom floors and other locations
18S&F Stainless steel 4\\" dia round Grating for nahany or floor trap cover with cockroach trap with or without hole
19S&F of 15 mm Stainless steel flexible hose 1.0 m long for hand shower / health faucet with brass nuts
20S&F of 15 mm CP finish brass body health faucet gun
21Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes
22Supplying & Fixing Indian make Flat Back Wash Hand Basin 1st quality conforming to IS:2556Part4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:29631979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 660 x 460 mm Single C.P. Pillar cock
23S&F of 15 mm brass angle stop valve of quarter turn spindle type of not less than 400 grams weight with internal threaded conforming to IS 8931
24Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge with all necessay fitting as per site requirement. 15 mm nominal dia
25S&F 15 mm nominal size CP finish brass over head shower arm of 450 mm long with 90 degree bend & wall flange suitable for rain shower 15 mm nominal dia
26Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
27Providing and fixing on wall face unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler110mm
28Providing and fixing on wall face unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with door 110x110x110 mm
29Providing and fixing on wall face unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend
30Providing and fixing on wall face unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe
31Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm
32Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks
33Providing and fixing underground drainage single socket pipes of SN4(3m) quality 150mm dia pipe
34Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
35Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
36Providing and fixing factory made single extruded WPC(WoodPolymerComposite)solidoor/window/Ceosetorywindows&otherFrames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints afterapplying PVC solvent cement and screwed with full body threaded Code Description Unit RateNo. 542 SUB HEAD : 26.0 NEW TECHNOLOGIES AND MATERIALS star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A categorywith property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shallbe paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extrapayment on this account shall be made. Frame size 45 x 70 mm
37Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required sizecomprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30mm thick
38Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screwsetc. complete. Twin rubber stopper
39Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level :
40Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
41Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm
42Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete.
43Supplying and fixing of 25 mm of FRLS (ISI) PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
44Wiring for light point/exhaust fan point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required.
45Supplying and drawing of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (2 X 2.5 sq. mm + 2 X 1.5 sq. mm earth wire )
46Supplying and drawing of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
47Supplying, installation, Testing & Commissioning of 18 watt LED Down light Recessed/ surface Down lighter (Round/square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt,frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, UGR < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K/ 5700°K / 6500°K (As per ANSI Bin), SDCM <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.Powder coated die cast /Extruded aluminium Body including trim with AluminiumReflector
48Supply and transportation of 10W, 1000 lumens, 600 mm (+/-10%) length LED batten tube light,housing made with PC body, wide operating voltage with Single / double side connection, PF≥0.9, Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT:3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty with BIS Certification.
49Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types and ceiling fans complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS /HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required.
50Supply, Installation, Testing and Commissioning of ceiling fan 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS :374-2019), THD (Total Harmonic Distortion) less than 10%,suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req
51Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
52Supplying and fixing 1 or 2 Module (75mmX75mm) , GI box/PVC along with modular base & cover plate for modular switches in recess etc. as required.
53Supply and fixing of Anchor fastner with fan hook / Providing MS Fan hook with grouting and cement plastering.
54Providing and fixing extra conduit down rod of 20 mm dia, 90 cm length wiring with 2 X 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required.
55Supplying and fixing following 5/6 A switch modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
56Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
57Supplying and fixing suitable size GI/PVC box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
58Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
59Supplying and fixing of 15/16 A modular socket outlet, along with 20A rating, 240/415V, 10kA, 'C' curve mcb ,suitable size GI box/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing of 3 pin 16A plug Top, connections etc. as required.
60Supply of 12\\" (300mm +/ - 5%) Light duty exhaust fan with metal blades etc complete for ante rooms / individual toilets.
61Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
62Installation of exhaust fan Upto 450 mm sweep in the existing opening, including making good the damage,WPC board of suitable size , connection, testing, commissioning etc. as required
63Supplying and fixing of single pole 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
64Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
65Supply and Fixing of TW / PVC Round Blocks
66Dismantling of the existing lights/fans/exhaust fans/switch boards/DB /PVC/ conduit/cable and panel boards,shifting and handover to store,etc., as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58289122
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 12.33 Lakhs
LAST DATE 27-11-2026
Authority
Authority Name National Institute Of Technology
Work Description Tender for Civil And Electrical Renovation Of Orc Suits Rooms No:111,112 And Proposed New Suit Room At Nit Warangal.
Basic Detail
Tender No 21/NITW/CMUNIT/CIVIL ELECTRICAL/2026-27
Bidding Type Tender
Location
City Warangal Urban
State Telangana
Key Dates
Publish Date 20 Nov 2026
Submission Date 27 Nov 2026
Open Date 30 Nov 2026
Finance
Tender Value 12.33 Lakhs
Tender Fee 1180
EMD 24700
Exemption Not Available
Document List
56bb70e7-1ccf-478e-b001-d0b7fbeff5ea.html
BOQ_979887.xls
finalenderdocorc2.pdf
nieq2.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 27, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Nov 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

56bb70e7-1ccf-478e-b001-d0b7fbeff5ea.html

xls

BOQ_979887.xls

pdf

finalenderdocorc2.pdf

pdf

nieq2.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer