Tender For Repair Of Soil Testing Lab At Dabwali Road Batinda

Issued by Government Departments · Bathinda, Punjab
Tender Value
40.67 Lakhs
Estimated cost
Bid Submission
10 Nov 2026
11 days left
EMD
81353
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bathinda → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair Of Soil Testing Lab At Dabwali Road Batinda

BOQ

Name of Work:- REPAIR OF SOIL TESTING LAB AT DABWALI ROAD BATINDA
Sl. No. Item Description
1Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority: EXECUTIVE ENGINEER PROVINCIAL DIVISION, BATHINDA NAME OF WORK:- REPAIR OF SOIL TESTING LAB AT DABWALI ROAD BATINDA Contract No: Composite Works Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Work Name Item Code / Make Quantity Unit RateRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2CIVIL WORK
3Scraping Of Colour Wash and White Wash
4scraping of cement plaster
512.5 mm thick cement plaster 1:4
6Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coatsto get required finish
7Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
8Wall painting with plastic emulsion paint of approvedbrand and manufacturer to give an even shade (two or more coats)
9Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint.
10Providing and fixing hydraulic door closerISI mark with necessary screw etc. complete
11Providing&Fixing glass pane swith nails and putty
12Providing and fixing mineral fibre false ceiling tiles at all heights With 16 mm thick beveled tegular mineral fibre Anti-microbial false ceiling tile of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection> 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K,Fire Performance as per (BS 476 pt - 6 &7)in true
13Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal ofmalbaatasuitableplacewithina distanceof100Mtrsof hecomplexcomplete in all respect.
14Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high trafficzones.)
15Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness
16Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-charge.
17Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1 (1999)(35mm) CSR 17.27
18Supplying and fixing of Japani sheet frames (Chowkat)consistingof18gauge(1.25mm) thick steel sheet of the specified section (standard designlatest), includingironlugs(holdfasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower boltsand finished, fixed in position including the cost of cement concrete1:3:6for fillingintheframeandcement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge
19Wire gauge Hollock wood door shutter without springs housed in chowkhat A 35 mm thick
20Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. (a) panelled, glazed or glazed and panelled. (ii)35 mm thick
21Wrought iron & Mild steel ladders, framed grills,gratings etc. with ends of bars riveted or moldedforged framed window guards, barred iron doorsstair case iron railing etc. including cost of boltsand nuts, screws, welding rod complete fixing inposition
22Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect (B)Glazing area above 0.09 sqm (IV)8.0mm thick Plate glass(weight not less than 20 kg/ sqm)
23Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consistingofwhite lead, linseedoil,Varnish, andChalkMitti includingfinishingthesurface to required finish complete.
24Applying pink primer or aluminum priming coat on woodwork including preparation of surface knotting and stopping etc.
25Applying priming coat with metal primer on new steel or iron work including preparation of surface.
26Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
27Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50 m lead (The cost of new tiles or bricks excluded).
28cost of new tiles
29Floating coat of 1:5mm thick neat cement laid inone operation to the topping
30115mm thick brick wall in cement sand mortar 1:4 withoutreinforcement in superstructure
31Extra for 115mm/100mm thick walls for additionalstoreyupto4metersabovethetopof structural roof oflower storey forBrickWork/ Concrete Block/ Clay Block.
3212.5 mm thick cement plaster 1:4
33Extra for Plastering in each subsequent storey above the first storey upto 4metre above plinth level.
34Centering and shuttering for flat surfaces such as suspendedfloors, roofs, landings, chajjas, shelves etc.
35Reinforced cement concrete M-25 mechanically batchmixed using batch type concretemixer asper IS:1791andvibrated by needle vibrator but excluding steel reinforcement centring andshuttering in superstructure.
36Cold twisteddetormed (Ribbed/ Tor steel)Bars (Fe500gradeasper IS1786-2008) , forR.C.C works,wherenot includinginthecompleterateof RCC including bending and bindingplacing in position complete
37ColouredGranitestonetiles15mmto20mmthick inskirting, risersof steps,dadowallsandpillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointedwith neat cement slurrymixedwithpigment tomatch the shadeof stone, including rubbingandpolishing including labour for fixing dowel pins andcramps
38Providing and fixing commercial plywood18mm thick
39Hollock wood cup board shutter with plywood panels orf acedon both side fixed inposition(excludingthecostofhandles, bolts haspwith staple but including the labour for fixing them)
40Providing & Fixing decorative high pressure laminated sheet 1mm (1Star) thickwithhighdensityprotectivesurface layer and reverse side of adhesive bondingquality conforming to IS : 2046Type S, including cost of adhesive of approved quality
41Providing & Fixing decorative laminatedsheet 0.72mm thick and reverse side ofadhesive bonding quality conforming to IS: 2046 Type S, including cost of adhesiveof approved quality.
42Providingand fixingspecial qualitybright finished brass cupboard or ward robe lockswith four leversof approvedquality includingnecessaryscrewsetc. complete in all respect as per thedirections of Engineer-in-charge
43Providing & fixing 6\\" stainless steel handles ISI marked on door &window framescomplete inall respectasper the directions ofEngineer-in-charge
44Providing&Fixingof 10gaugeweldedmeshof 25mmx25mmsize fixedonsteel glazingwith MS flat 20mmx 6mmbeedingcomplete inall respect including painting two coats with Synthetic Enamel Paint and Priming Coat
45Providingand fixingbright finishedbrass 100mmmortise latch and lock with 6 levers and a pair of lever handleswith necessaryscrews etc. complete (best make of approved quality).
46Electrical Services
47RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:
48Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
49Wiring fan point (Without fan box)
50Wiring light point
51Wiring 6Amp. wall socket point
52Wiring 6Amp. Plug control comprising wall socket point
53Wiring 16/20Amp. power plug control point
54Wiring light point without control switch.
55RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):
56Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
57Wiring Computer terminal point having 2 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16/20Amp. universal Socket (shuttered) and 2Nos. 16/20Amp. switch with indicator (Modular accessories).
58RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):
59Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
60Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
61RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):
62Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
63Wiring Networking socket point RJ45 (one module)
64PVC INSULATED FR COPPER CONDUCTOR CABLES:
65Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
66Overall size 1.5sq.mm (Un-sheathed)
67Overall size 2.5sq.mm (Un-sheathed)
68Overall size 4sq.mm (Un-sheathed)
69Overall size 10sq.mm (Un-sheathed)
70Overall size 25sq.mm (Un-sheathed)
71Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
72CAT 6 LAN cable
73PVC, HDPE PIPES & PVC FLEXIBLE PIPES:
74Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
75Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed)
76Heavy Gauge PVC Conduit Pipe 32mm dia. (Flushed)
77Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed)
78XLPE INSULATED UN-ARMOURED CABLES (LOOSE):
79Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
80Overall size 35sq.mm (3½ Core) Un-armoured (Loose)
81MINIATURE CIRCUIT BREAKERS:
82Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
83MCB Single Pole 6-32amp. (10kA, Curve-C)
84MCB Double Pole 50, 63amp. (10kA, Curve-C)
85MCB Four Pole 50, 63amp. (10kA, Curve-C)
86COPPER EARTHING: 8 SWG COPPER EARTHING :
87Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
88Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
89Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:-
90Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface)
91SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:
92Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
93SP&N Double Door Distribution Board 8 way each
94TP&N Horizontal Double Door Distribution Board 8 way each
95MCCB's (MOULDED CASE CIRCUIT BREAKER):
96Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
97MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
98SHEET METAL IRON CLAD SWITCHES:
99Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:-
100ICTPN Switch 100amp., 415volts
101Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary.
102Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary.
103Supply and erection of Slim Recessed mounted, Round downlighter 18 watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with CRCA sheet with control gear (IP 20 protection), THD<10%, CRI minimum 70, Low power LED with wattage Less 1 Watt, Surge Protection 2.5KV and above as per IS/ IEC Standards, efficacy of LED fixture minimum 100 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab
104Supply and erection of Recessed Mounted 36 Watt LED 2x2 panel (including constant LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary
105Supply and erection of Wall Fan Plastic Body 400MM, 16\\" including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
106Supply and erection of Heavy duty Exhust Fans 300mm sweep 900RPM complete with aluminium louver shutter double ball bearing, longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
107Supply and erection of 3-Star rating AC Ceiling Fan 1200mm (48\\") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site.
108Less Dismental material
109Public Health Services
110Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.Single Socket Type B
111110mm o/d SWR UPVC pipe lines laid complete
11290mm o/d SWR UPVC pipe lines laid complete
113Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
114Door Elbow 90 Degree (All side socketed)
115Vent Cowls
116Coupler
117Single Tee With Door
118Door elbow 90 degree (all side socket)
119Vent Cowls
120Coupler
121Single Tee With Door
122With 110mm o/d outlet shallow seal at First Floor, S.F, T.F.
123Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects.
124Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge)110mm o/d
125Single Tee With Door
126Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge)90mm o/d
127P Trap/Floor Trap 110mm x 110mm
128Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting.
129M.S. Holder bats clamps for 100mmi/d H.C.I. pipes
130M.S. Holder bats clamps for 90mm o/d as per table-1
131Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
132100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mmas per table-1
133Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weightas per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
134450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal
135Cement concrete 1:2:4 With stone ballast or shingle mixing by manual means
136110mm o/d SWR UPVC pipe lines laid complete
13790mm o/d SWR UPVC pipe lines laid complete
138Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
139Through wall 11.43 cm thick
140Through wall 22.86 cm thick
141CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
142SDR 11 CPVC pipes & fittings 20mm o/d
143INTERNAL- EXPOSED ON WALL :Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in Charge
144SDR 11 CPVC pipes & fittings 25mm o/d
145Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm
146qty same as CPVC PIPE 20mm o/d to 25 mm
147Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
148Through wall 11.43 cm thick
149Through wall 22.86 cm thick
150Providing, fixing and jointing Cpvc Union Couplings with Upvc Pipes complete in all respect.
15125mm i/d CPVC Union ( Ex. Pipeline)
15225mm i/d CPVC Union
153Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete.
15425mm i/d CPVC Ball valves
155Providing, fixing and jointing cpvc Tank Nipple with Cpvc Pipes complete in all respect.
15625mm i/d CPVC tank nipple( For Ex. Inlet + Outlet)
157Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball
158Brass Ball Cock with rod and Plastic Ball 25mm i/d
159Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge.
160Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete.
161Vitreous white Chinaware Partition
162Large partition size 75 x 16.5 x 36.5 cm
163Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.
164Size 550 mm x 400 mm x 815mm
165Providing and fixing vitreous chinaware standard pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect.
166Vitreous chinaware standard white pedestal for wash hand basin.
167Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut
168Qty same as OWC+EWC+WB
169Providing and fixing P.V.C Waste Pipe Collapsible 32mm complete in all respect.
170For Sink
171Qty same as WB+Urinal+
172Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
173C.P brass towel ring
174Qty. as per Detail in Table-3
175Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
176Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm)
177Qty. as per Detail in Table-3
178Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.
179C.P Brass bib cock foam flow without flange
180Qty. as per Detail in Table-3
181Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
182C.P.brass 15mm Angle valve without flange
183Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
184Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect.C.P. Brass extension piece, 25mm long to 50mm long
185Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks
186500 ltr Capacity
187Screed of 50mm thick cement concrete 1:8:16 with stone aggregateto be laid below the topping using mechanical mixer for mixing of material
188Toilet
189deduct duct area
190Extra rate for Second Floor
191Supplying and filling cinder on roof (Ist to third story)including light ramming
192Qty Same as Item 14.11
193(Labour Rate) For Taking out & Refilling
194Qty Same as Item 14.11
195Extra Cinder for Decreased Cinder After Drying Old Cinder
196Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete .
197Qty same as Screed
198Total all Floors
199Extra rate for Second Floor
200Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish / Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
201Toilet Total All Floors
202Extra rate for Second Floor
203Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge) including carriage and fixing in position complete in all respect.
204Supplying,errection, testing & commissionng of split type fixed speed air-conditioners Rating Three star Cap.2.00 TR confirming to IS:1391 (Part-2)-1992 with amendments No.1& 2 fitted with Rotary compressor operating on Refrigerant R-32 suitable for wall mounting of reputed make with 5.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respectsi) 2 TR
205Supplying,errection, testing & commissionng of split type fixed speed air-conditioners Rating Three star Cap.1.50 TR confirming to IS:1391 (Part-2)-1992 with amendments No.1& 2 fitted with Rotary compressor operating on Refrigerant R-32 suitable for wall mounting of reputed make with 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects
206Providing laying hard soft copper concealing of copper pipes of dia 12.7mm od (insulation = 13mm)/9.5mm od (insulation = 13m) as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects.
207For 1.50 tonne split AC
208Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe (TYPE-A) Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects.
209uPVC Pipe 6 Kgf/cm2
21040 mm o/d
211For split AC
212Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm
213qty same as 28.12
214Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
215Through wall 22.86 cm thick
216PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE:
217Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-
218Overall size 2.5sq.mm (50/0.25mm), 3Core
219For split AC
220MINIATURE CIRCUIT BREAKERS:
221Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
222MCB Double Pole 6-32amp. (10kA, Curve- C)
223For 1.50 tonne split AC
224PLASTIC DISTRIBUTION BOARDS:
225Supply and erection of Plastic enclosure DB's of various sizes on surface on wall for mounting MCB's SP/ DP/ FP including fixing and other petty material etc.:-
226Plastic enclosure MCB DB 4way
227For 1.50 tonne split AC
228Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.
229110 mm o/d pipes
230IC to Exist IC
231110 mm o/d pipes
232For Sewer Line GT to IC 3mtr each 110mm
233Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.
234Depth not exceeding 3 m. BGL.For all classes of soil except rocky
235For Sewer Line 110 mm dia
236Cement concrete 1:6:12 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type
237For covering Sewer Line Type II
238For Sewer Line 100 mm i/d (Type-I)
239Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work.
240For covering Sewer Line Type II
241For Sewer Line 110 mm i/d
242Sub Work -3
243Sub Head-1 Dismantling
244Dismantling Sanitary fixtures such as Eurpoean /Indian / Orissa W.C., PVC / China ware cistern, Wash Hand Basin, Urinal Pot, Sinks and CP Fittings and disposal of dismantled material with in a distance of 100 Mtr. complete in all respect as required by Engineer-in-Charge.
245Eurpoean/Indian/Orissa W.C.,
246PVC / China Ware Cistern
247Wash Hand Basin / Urinal Pot
248Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect.
249Qty, Same as per Item No.14.127
250Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect.
251Qty, Same as per Item No.14.11
252Labour for carrying dismantled material Total in Figures 4067629.22 4067629.22 INR Forty Lakh Sixty Seven Thousand Six Hundred & Twenty Nine and Paise Twenty Two Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58289059
AUTHORITY Government Departments
TENDER VALUE 40.67 Lakhs
LAST DATE 10-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Repair Of Soil Testing Lab At Dabwali Road Batinda
Basic Detail
Tender No PB/BTI/46
Bidding Type Tender
Location
City Bathinda
State Punjab
Key Dates
Publish Date 30 Oct 2026
Submission Date 10 Nov 2026
Open Date 10 Nov 2026
Finance
Tender Value 40.67 Lakhs
Tender Fee 5000
EMD 81353
Exemption Available
Document List
BOQ_364565.xls
e2159aa9-b96d-4908-a756-a12cfbcb2e2e.html
sbd46.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 30, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Nov 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Nov 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_364565.xls

html

e2159aa9-b96d-4908-a756-a12cfbcb2e2e.html

pdf

sbd46.pdf

pdf

Tendernotice_1.pdf

Disclaimer