Tender For Repair / Replacement Of External Electrification, Water Supply, Cleaning Of Over Head Tanks And Repair / Maintenance Of Pumps, Dg Sets, Solar Street Lights And Connected Allied Works, Sweage Treatment Plant In The Aor Of Hebbal Garission U
Tender Overview
Project Description
Tender for Repair / Replacement Of External Electrification, Water Supply, Cleaning Of Over Head Tanks And Repair / Maintenance Of Pumps, Dg Sets, Solar Street Lights And Connected Allied Works, Sweage Treatment Plant In The Aor Of Hebbal Garission Under Ge (South) Bangalore
BOQ
| Sl. No. | Item Description |
| 1 | M & L excavation in trenches in soft/loos soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed. |
| 2 | M & L excavation in trenches in soft/loos soil not less than 1.5 mtr deep and not exc 3 mtr in deep for pole foundation etc complete all as specified and as directed. |
| 3 | M & L for returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete as specified and as directed |
| 4 | M & L for removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed |
| 5 | M & L for sand cushioning with a layer of dry sand 23 cm thick under and above the cable complete all as specified and as directed |
| 6 | S & L sub class burnt bricks for cable protection complete as specified as directed |
| 7 | Taking down old unsv/burnt XLPE cable from trench/wall/pole of following size :- |
| 8 | (a) 2 C x 10 Sqmm |
| 9 | (b) 4 C x 10 Sqmm |
| 10 | (c) 4 C x 16 Sqmm |
| 11 | (d) 3.5 C x 25 Sqmm |
| 12 | (e) 3.5 C x 35 Sqmm |
| 13 | (f) 3.5 C x 50 Sqmm |
| 14 | (g) 3.5 C x 70 Sqmm |
| 15 | (h) 3.5 C x 95 Sqmm |
| 16 | (j) 3.5 C x 120 Sqmm |
| 17 | Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable legs including neccessary roadcrossing if applicable for following size :- |
| 18 | (a) 2 C x 10 Sqmm |
| 19 | (b) 4 C x 10 Sqmm |
| 20 | (c) 4 C x 16 Sqmm |
| 21 | (d) 3.5 C x 25 Sqmm |
| 22 | (e) 3.5 C x 35 Sqmm |
| 23 | (f) 3.5 C x 50 Sqmm |
| 24 | (g) 3.5 C x 70 Sqmm |
| 25 | (h) 3.5 C x 95 Sqmm |
| 26 | (j) 3.5 C x 120 Sqmm |
| 27 | M & L in repair for GI tubing light grade 40mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. Note road cutting rate are included on the above items |
| 28 | M & L in repair for GI tubing light grade 50mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. Note road cutting rate are included on the above items. |
| 29 | M & L in repair for GI tubing light grade 80mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. Note road cutting rate are included on the above items. |
| 30 | M & L in repair for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized strip 25x4mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 1991 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed incl dismantling and taking out old U/S. |
| 31 | M & L in repair for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed incl dismantling and taking out old U/S. |
| 32 | S & F in replacemet of UNSV existing /suitable size MCCBs 4 pole 415 Volts 50HZ incl complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools insulating the naked portion with insulation tape as under:- |
| 33 | (a) MCCB 100 Amps ,16 KA with adjustable Thermal setting |
| 34 | (b) MCCB 200 Amps 36 KA with adjustable Thermal setting . |
| 35 | (c) MCCB 250 Amps 36 KA with adjustable Thermal setting . |
| 36 | (d) MCCB 315 Amps 36 KA with adjustable Thermal setting . |
| 37 | (e) MCCB 63 Amps , 25 KA with adjustable Thermal setting |
| 38 | M&L for in repair cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core/4core XLPE armoured aluminium conductor cable for following sizes:- |
| 39 | (a) 3.5 C x 25 to 35 Sqmm |
| 40 | (b) 3.5 C x 50 to 120 Sqmm |
| 41 | M&L for painting of steel tubular/PCC poles of any height and type ,incl security light mounting brackets with one coat of aluminium paint/two coat of cement base paint incluing painting black and yellow strip or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering of pole complete all specified and as directed. |
| 42 | Dismantling the damaged unservicable pole of any type. |
| 43 | Supply and errect steel tubular swaged poles complete with cast iron base plate,finial taper plug,bolts,nuts & screws as specified type 410SP-31, 9 mtr long . |
| 44 | M&L for PCC 1:3:6 type C1 with 20mm graded stone aggregate for couping of pole,filling and mass concrete of pole, make good to road surface , hard standing etc incl necessary form work all as specified and as directed |
| 45 | M&L for PCC 1:4:8 type D2 with 40mm graded stone aggregate in foundation of poles all as specified and as directed |
| 46 | M&L for outdoor type, double door sheet metal enclosure/Junction box of size 80x80x30 cm with aluminium bus bar 400 Amps for 3 phase & neutral including MCCB 4 pole 415 volts 250 Amps 36 KA .including removing old unserviceable junction box complete all as specified and as directed |
| 47 | Supply and fix in replacement of Timeline distribution board 32 A 3 pole /230V analog time switch including complete accessories relay contactor, timer etc, all as specified and as directed. |
| 48 | M&L for cable fault finding for LT cables any sizes complete all as specified and as directed |
| 49 | Supply & Fix in repair on pole/ wall etc GI pipe bracket made of 40mm bore light grade GI pipe1.5 mtr long suitably bent to shape and fixed on wall/ pole for fixing street light fitting with 2 Nos suitable MS clamps of size 25 x 3 mm size incluiding bolts, nuts, washers all as specified and as directed. |
| 50 | Supply and fixing,replacement of moulded (FRP) junction box with IP 65 protection of size 300x200x80mm with 32 Amp 4 way heavy duty terminal block with 6 Amp MCB SP and two number of cable entry gland of standard size with suitable MS bracket to fix with pole complete all as directed |
| 51 | Supply and fixing in repair 60 W LED street light fitting with pressure die cast housing along with prismatic polycarbonate modular secondary lens optics with IP 66 ingress protection and impact resistance of IK 08. 4kV inbuilt and 10 kV external surge protection with top opening driver cover for easy maintenance .including taking down old unserviceable street light fittings from pole. |
| 52 | Supply and fixing in repair 90 W LED street light fitting with pressure die cast housing and toughened glass and individual LEDs with secondary lens optics with IP 66 ingress protection and impact resistance of IK 07. 5kV inbuilt and 10 kV external surge protection with top opening driver cover for easy maintenance .including taking down old unserviceable street light fittings from pole. |
| 53 | S&F in replacement of 2 runs of PVC insulated 2.5 sqmm single core multistranded copper conductor cable and one run of 2.5 sqmm copper wire as earth continuity conductor drawn through and incl rigid non metalic conduit 20 mm external dia fixed on poles & connecting up all as specified and as directed. |
| 54 | Supply & fix in replacement of on load Change over switch 4 pole in sheet metal enclosure compact design rating 63 Amps suitable for isolation and prevent leakage current/ flush over between phases, handle lock feature in off position with three padlocks complete all as specified and as directed. |
| 55 | Supply & fix in replacement of on load Change over switch 4 pole in sheet metal enclosure compact design rating 100 Amps suitable for isolation and prevent leakage current/ flush over between phases, handle lock feature in off position with three padlocks complete all as specified and as directed. |
| 56 | Supply & fix in replacement of on load Change over switch 4 pole in sheet metal enclosure compact design rating 400 Amps suitable for isolation and prevent leakage current/ flush over between phases, handle lock feature in off position with three padlocks complete all as specified and as directed. |
| 57 | Dismantling and taking out the LED street light fittings any make from Pole and removing the burned out /unserviceable LED driver 25 W to 60W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site. |
| 58 | Dismantling and taking out the LED street light fittings any make from Pole and removing the burned out /unserviceable LED driver 90 W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site. |
| 59 | Dismantling and taking out the flood light from high mast pole and removing the burned out/unserviceable LED driver 200 W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site. |
| 60 | Supply & Fix in repair 200W LED flood light luminaries with innovative die-cast aluminium flood light with highly efficient LEDs as light source, suitable for highmast lighting with complete accessories including taking down old unserviceable flood lights from high mast pole all as specified and as directed. |
| 61 | S&F in replacement of new generation 25 Watt post top energy saving IP-65 enviornmental , friendly long life with symmetrically light distribution , spun aluminium with high power LED. Make :- Havells Cat No. CORALPT25WLED757PSYMTOPC |
| 62 | S&F in replacement of Stellar LED post-top offering combination of sturdy design, execllent illumination and aesthetics in one go. IP 66 and IK 10 rating ensures it stands tall amid varid environemtnal conditionsl , friendly long life with symmetrically light distribution , spun aluminium with high power LED. Make :-Mk -Havells or eqv-Phillips/ Crompton |
| 63 | S&F in replacement of TERRAIN post top lentern is a wether proof indirect lighting solution wich improves horizental uniformity , with reduced glare and improved lighting control saving IP-65 enviornmental , friendly long life with symmetrically light distribution , spun aluminium with high power LED. Make :-Mk -Crompton or eqv-Phillips/ Havells |
| 64 | M&L for painting of outdoor type Feeder piller panel upto the size of 1100 x 450 x 1200 mm (approx), incl replacement of door hinges with new one and apply one coat of smoke grey colour paint and base angle with black paint complete or as directed by Engineer-in-charge complete all specified and as directed. |
| 65 | M&L for painting of outdoor type Lt panel upto the size of 2500 x 600 x 3000 mm (approx), incl replacement of door hinges with new one and apply one coat of smoke grey colour paint and base angle with black paint complete or as directed by Engineer-in-charge complete all specified and as directed. |
| 66 | Boring of holes under road, pavement, hard standing by trenchless techless using ultra sounding technique and necessary machine including HDPE pipe of 63 mm dia bore suitable for 0.4 mpa working pressure complete all as specified and as directed. |
| 67 | M&L for repair of Lt panel upto the size of 2500 x 3000 mm (approx), incl replacement of door hinges with new one and duly with powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of smoke grey colour as directed by Engineer-in-charge complete all specified and as directed. |
| 68 | Supply, testing and commissioning in replacement of weather and vermin proof LT feeder pillar box factory fabricated outdoor cubical/kiosk type CPRI approved and confirming to IS 5036 totally enclosed made out of 3 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly with powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar for phase & neutral 500 Amps,36 KA capacity and IP 54 protection mounted on epoxy insulator-01 Set including mounting the panel board on ground with PCC 1 :3:6 bedding upto a height of 50 cm above ground level and the size of feeder should not less than 150x130x 45 cm. complete all as directed and comprising the following including taking out unseviceable LT Panel :- (i) Incoming MCCB 4 pole, 400 Amps 36 KA 415 Volts -01 No (ii) Outgoing MCCB 4 pole, 250 Amps 25 KA 415 Volts -01 No (iii) Outgoing MCCB 4 pole, 200 Amps 25 KA 415 Volts -02 Nos (iv) Outgoing MCCB 4 pole, 100 Amps 16 KA 415 Volts -02 Nos (v) Digital Voltmeter 0-500 volts with selector switch - 01 No (vi) Digital Amps meter CT operated 0-400 Amps with phase selector switch - 01 Nos (vii) LED Indicator lamp ( RYB ) - 01 Set (03 Nos) |
| 69 | Excavation in trenches not exceeding 1.5 m depth and not exceeding 1.5m width and getting out in Soft/loose soil for laying of pipe lines. |
| 70 | Returning, refilling incl spreading, levelling watering and well ramming in layers not exceeding 25 cm thick with any type of soil all as directed |
| 71 | Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified as directed. |
| 72 | Taking up CI/DI water mains (including all fittings), with spigot and socket ends and lead joints/Titan Joints for the following size :- |
| 73 | (a) 150 mm bore |
| 74 | (b) 100 mm bore |
| 75 | (c) 80 mm bore |
| 76 | Dismantaling the sluice valves in various location and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland nuts, gland packing etc and refixing after properly repairs of the following sizes:- |
| 77 | (a) 150 mm dia bore |
| 78 | (b) 100 mm dia bore |
| 79 | (c) 80 mm dia bore |
| 80 | M&L for repacking stuffing box of sluice valve spindle including taking a part and reassembling of following sizes:- |
| 81 | (a) 150 mm bore |
| 82 | (b) 100 mm bore |
| 83 | (c) 80 mm bore |
| 84 | Taking up the old/rusted/unsv GI/CI/HDPE/PPR pipes with fittings and connected control gate valves/ Sluice valve/non return valve/foot valve etc. from sump/ trenches/ floors/roof for the following size:- |
| 85 | (a) 15 mm dia |
| 86 | (b) 20mm dia |
| 87 | (c) 25mm dia |
| 88 | (d) 40mm dia |
| 89 | (e) 50mm dia |
| 90 | (f) 80mm dia |
| 91 | (g) 100mm dia |
| 92 | S&F GI water tubing medium grade with all fitting (flanged/socket/union/tee etc) laid in trenches/walls/floors/roof of following sizes :- |
| 93 | (a) 15 mm dia |
| 94 | (b) 20mm dia |
| 95 | (c) 25mm dia |
| 96 | (d ) 40mm dia |
| 97 | (e) 50mm dia |
| 98 | (f) 80mm dia |
| 99 | (g) 100mm dia |
| 100 | S&F brass non return valve of the following size dia internal threded type complete including taking down the existing all as specified and as directed. |
| 101 | (a) 63/65/80 mm dia |
| 102 | (b) 100 mm dia |
| 103 | Supply & fixing in replacement of the following size gun metal Gate valve with iron wheel. |
| 104 | (a) 15 mm dia |
| 105 | (b) 20 mm dia |
| 106 | (c) 25 mm dia |
| 107 | (d) 40 mm dia |
| 108 | (e) 50 mm dia |
| 109 | (g) 80 mm dia |
| 110 | S&F in replacement of sluice valve both side flanged and ISI marked (IS-780) of sluice valve cast iron body with S/S spindle and brass fly nuts, class PN-1.6 and cast iron hand wheel and joining with nut, bolt, washers and rubber insortion packing 6mm thick etc of following sizes:- |
| 111 | (a) 150 mm dia bore |
| 112 | (b) 100 mm dia bore |
| 113 | (c) 80 mm dia bore |
| 114 | Removing of unserviceable foot valve from tank and replacement with new CI foot valve ball type of following sizes:- |
| 115 | (a) 100 mm dia bore |
| 116 | (b) 80 mm dia bore |
| 117 | (c) 50/63 mm dia bore |
| 118 | Removing old unserviceable float valve from service tank supply and fix float valve with PVC body aluminium float rod, nylon float high pressure type for the following size:- |
| 119 | (a) 20 mm bore |
| 120 | (b) 25 mm bore |
| 121 | Taking out old unserviceable foot valve from UG sump and removing unserviceable leather from suction line and replacement the same with high quality leather including nuts, bolts, washer etc and servicing for the following sizes. |
| 122 | (a) 100 mm bore |
| 123 | (b) 80 mm bore |
| 124 | Supply and filling Calcium hypochlorite granular(65-80%chorine contect)disinfectant in Sumps complete as specified and directed by Engineer-in-charge |
| 125 | Dismantling Old valve pit complete with deteriorated MS cover and Construction of brick massonry valve pit chamber of inner dimension 100x100x100 cms suitable for sluice valves upto 150mm size, with PCC 1:4:8 type D-2 for foundation, brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, incl necessary earth work, including MS sheet cover of thickness 3.15mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement . |
| 126 | S&F in replacement of Air release valve of existing size suitable for centrifugal pump set complete all as specified and as directed. |
| 127 | S & F in repair of Voltmeter (0-500 V), Ammeter (0-400A) (Make Meco) & indication lamps |
| 128 | Supply & laying in replacement of flat submersible copper cable for of following sizes:- |
| 129 | (a) Flat copper cable 3 core 2.5 Sqmm. |
| 130 | (b) Flat copper cable 3 core 6 Sqmm. |
| 131 | Repairs/Maintenance of centrifugal/monoblock pumpsets regularly/systematically including inspection, adjustment repairs by opening the pump set for carrying out the preventive maintenance and repair by checking the serviceability alignment of various spares, removing the unserviceable pump spares and replacing with new spare parts, components servicing, cleaning and overhauling the same by lubricating, replacement of gasket, refixing the same after servicing, testing the same for smooth running, replacing minor parts like Gland rope, bolts & nuts, packing, threading and replacing spares and matching inclusive etc all as specified and as directed by Engr-in-charge of the following capacities pump sets. Note : New spares shall be measured and paid separately. |
| 132 | (a) 15 to 25 HP any model & make |
| 133 | (b) 5 TO 10 HP any model & make |
| 134 | Disconnecting the electric cable from the terminal box of upto 5HP motor, disconnecting the motor from them pump, remove the motor from the foundation bed and taking out the motor and transporting to authorised work shop and performing following works as specified and directed by Engr-in-Charge |
| 135 | (i) Dismantling the motor and taking out the burnt copper winding /fiber strip/insulating materials and worn out ball bearing - 2 Nos |
| 136 | (ii ) Clean the stator slots by CTC solution and rewind on stator slots with super enamelled copper wire of existing gauge with insulating materials/fiber strip/varnishing and made terminal connection of fiber glass coated wire. |
| 137 | (iii) Replacement of ball bearing - 2 Nos |
| 138 | (iv) Assembling the motor and painting with two coat of primer and one coat of synthetic enamel paint including marking flow of water and MES NO all as per norms and all as specified and as directed as directed by the engr-in-charge. |
| 139 | (v) Transporting to the motor to the site refixing on foundation channel with new bolts and nuts, coupling the pump and motor with correct alignment apply grease and connecting electrical connections testing complete alll as directed and specified by the Engr-in-charge |
| 140 | Disconnecting the electric cable from the terminal box of 7.5 to 15HP motor, disconnecting the motor from them pump, remove the motor from the foundation bed and taking out the motor and transporting to authorised work shop as specified and directed by Engr-in-Charge |
| 141 | (i) Dismantling the motor and taking out the burnt copper winding /fiber strip/insulating materials and worn out ball bearing - 2 Nos |
| 142 | (ii ) Clean the stator slots by CTC solution and rewind on stator slots with super enamelled copper wire of existing gauge with insulating materials/fiber strip/varnishing and made terminal connection of fiber glass coated wire. |
| 143 | (iii) Replacement of ball bearing - 2 Nos |
| 144 | (iv) Assembling the motor and painting with two coat of primer and one coat of synthetic enamel paint including marking flow of water and MES NO all as per norms and all as specified and as directed as directed by the engr-in-charge. |
| 145 | (v) Transporting to the motor to the site refixing on foundation channel with new bolts and nuts, coupling the pump and motor with correct alignment apply grease and connecting electrical connections testing complete alll as directed and specified by the Engr-in-charge |
| 146 | Disconnecting the electric cable from the terminal box of 25HP motor ,disconnecting the motor from them pump, remove the motor from the foundation bed and taking out the motor and transporting to authorised work shop as specified and directed by Engr-in-Charge |
| 147 | (i) Dismantling the motor and taking out the burnt copper winding /fiber strip/insulating materials and worn out ball bearing - 2 Nos |
| 148 | (ii ) Clean the stator slots by CTC solution and rewind on stator slots with super enamelled copper wire of existing gauge with insulating materials/fiber strip/varnishing and made terminal connection of fiber glass coated wire. |
| 149 | (iii) Replacement of ball bearing - 2 Nos |
| 150 | (iv) Assembling the motor and painting with two coat of primer and one coat of synthetic enamel paint including marking flow of water and MES NO all as per norms and all as specified and as directed as directed by the engr-in-charge. |
| 151 | (v) Transporting to the motor to the site refixing on foundation channel with new bolts and nuts, coupling the pump and motor with correct alignment apply grease and connecting electrical connections testing complete alll as directed and specified by the Engr-in-charge |
| 152 | Scraping the old paint by using wire brush and emery paper and preparation of the surface for painting the following pumpset's /control panel /suction and delivery pipe of the pump house with one coat of primer and two coat of synthetic enamel paint all as specified and directed at site of the following capacity including marking flow of water and MES NO all as per norms and all as specified and as directed |
| 153 | (a) 15 to 25 HP Pump set |
| 154 | (b) 5 TO 10 HP Pump set |
| 155 | Disconnect the electrical connection,Lifting the submersible pumpset with 50mm GI pipe from 500 to 700 feet depth bore well up to 7.5 HP capacity and dismantling the pump set and rewinding the submerssible motor with super enamelled copper wire of suitable gauge replacing the damaged impeller, bearing , bushes, stainer as per exisiting size and assembiling the same including necessary lathe works, fixing the motor and proper insulation ,connecting and testing with apply one coat of primer and two coat of synthetic enamel paint and lowering the same and testing and commissioning all as directed at specified by the Engr-in-charge |
| 156 | Removing the defective single phase preventer from star/delta starter and supply and fixing new single phase preventer suitable for various capacity of motors 5/7.5 /15/25 HP |
| 157 | Taking down carefully electric driven centrifugal / Monoblock pump 5 to 25 HP from foundation/ MS channel after disconnecting suction/ delivery lines/main electric supply from motor starter panel for replacement of ball bearing -02 Nos as per existing size at site / nearest repairing workshop including bring back and reassembling the same complete all as directed by Engr-in-charge. |
| 158 | Taking down carefully electric driven Motor 5 to 25 HP from foundation/ MS channel after disconnecting suction/ delivery lines/main electric supply from motor starter panel for replacement of ball bearing -02 Nos as per existing size at site / nearest repairing workshop including bring back and reassembling the same complete all as directed by Engr-in-charge. |
| 159 | Repair the star/delta starter fully automatic starter including replacing with new spares ie. Contactor, timer, relays etc suitable for existing make and capacirty of ML1/ML2/ML3/ML4/ML1.5/MK1. Note : Spares shall be measured and paid separately. |
| 160 | Supply only starter contactor of ML 1.5 Type Make L & T or eqv |
| 161 | Supply only starter contactor of ML 2 W Type Make L & T eqv |
| 162 | Supply only starter relay of ML 2 /3Type Make L & T or eqv |
| 163 | Supply only standard operating coil for ML 1.5 Type Make L & T or eqv |
| 164 | Taking out the existing unsv submersible panel, supply & fixing of new accessories like starter single phase preventor, fuse cut outs, indicating lamp, coil, terminal block etc suitable for 5/7.5 HP, submersible pump set for outdoor application. Note :- Job includes necessary civil works such as foundation, grounding of panel etc & connecting back existing old cables. |
| 165 | S&F in replacement of Electronic Timers ST 100 operating range of 160V to 500V make L & T or eqv as required |
| 166 | Dismantling the existing old pressure gauge from the pump set/water supply line and provision of new pressure guage 1-10.6 kg per sq cm 100 mm dia dial 3/8\\" threaded type with stop cock arrangement. |
| 167 | S&F new pump shaft as per existing size of the following capacity pump sets |
| 168 | (a) 15 to 25 HP Pump set |
| 169 | (b) 5 to 10 HP Pump Set |
| 170 | S&F new rubber with CI coupling set suitable 10 to 25 HP for centrifugal pumping set including key, lock, stud etc complete all accessories as existing size of the following capacity pump sets. |
| 171 | S&F in replacement of GI pipe heavy duty 50 mm dia with heavy duty socket. |
| 172 | S&F in replacement of LED indication lamps from Lt panels of colours Red, Green and Yellow. |
| 173 | M&L in replacement of Mechnical joints with rubber washer, nuts and bolts as existing at site of the following sizes of CI/DI pipes :- |
| 174 | (a) 80 mm bore |
| 175 | (b) 150 mm bore |
| 176 | (c) 100 mm bore |
| 177 | M&L for Emptying complete water, removing sludge, silt, cleaning internally all the walls and bottom with wire mesh/brush/brooms etc by using washing soda and bleaching powder completely, finally cleaning with plain water for making the UG sump suitable to store potable drinking water incl one coat white washing inside and marking outside sump in visible place the capacity of sump, date of cleaning, due date for cleaning with white enamel paint, over black enamel paint complete all as specified and as directed by Engineer-in-Charge for the following sumps:- |
| 178 | (a) Capacity of 30000 gallons |
| 179 | (b) Capacity of 33000 gallons |
| 180 | M&L for Emptying complete water, removing sludge, silt, cleaning internally all the walls and bottom with wire mesh/brush/brooms etc by using washing soda and bleaching powder completely, finally cleaning with plain water for making the OH reservoir of any staging suitable to store potable drinking water incl one coat white washing inside and marking out side sump in visible place the capacity of Tank, date of cleaning, due date for cleaning with white enamel paint, over black enamel paint complete all as specified and as directed by Engineer-in-Charge for the following overhead reservoirs including staging:- |
| 181 | (a) Capacity of 30000 gallons |
| 182 | (b) Capacity of 33000 gallons |
| 183 | Supply and installed avaiation lights of LED Based all as specified and directed by Engr-in-Charge. |
| 184 | M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized strip 32x6mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2020 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed. |
| 185 | M&L for Air termination single pointed aluminium rod 12mm dia and 300mm long |
| 186 | M& L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex, head screw. |
| 187 | M&L for Aluminium Strip 25x3.15mm with saddles and fixing screws etc, for roof conductors and down conductors above ground. |
| 188 | Comprehensive maints / periodical maintenance / servicing and repair of standby Eco Friendly/Acoustic type DG set 200 KVA of check 250Hrs or 6 Months which ever is earlier.Note : 1. As per maintenance schedule prescribed in repair and maintenance manual (Repair & maintenance should be carried out by the qualified and experianced mechanic from the servicing centre who is conversant with the DG set and report should be submitted by the contractor)2. Rate quoted by the contractor includes the fixing charges for replacement of parts specified in relevant item here in after. 3. The tenderer shall produce qualification and experiance cerificate of the mechanic to the Engineer in charge and approved personal only will be allowed to carried out the work |
| 189 | Checking and servicing includes the following :-(i) Lubricant oil leaking.(ii) Operation and repairs to lubricant oil leakage and cooling system leakage, radiator operation with coolant, hoses and connection, belt connection and tension. Fan hub drive pulley and water pump operation and cleaning of radiator cooling system.(iii) Leaking in air intake system, maintenance filter & air cleaner piping connection.(iv) Fuel line and connection, fuel injection pump, cleaning of fuel tank for removing sediments(v) Leakage in exhaust system and exhaust restriction, drain out condensate trap, cleaning & maintenance of exhaust manifold and turbo charger cap screw.(vi) Battery charging system & topping up electrolyte and maintenance of specific gravity(vii) Cleaning of engine tighten of all nut bolt washer and unusual vibration.(viii) Checking to electric connection & smooth operation of generator control panel, greasing to all bearing and movable part, measurement and recording winding insulation resistance cleaning up complete generator/alternator. |
| 190 | Supply only following parts of DG set 200 KVA specified under ser item No 1 and replacement as per recommendation of manufacturer & all as directed .NOTE:-Taking down & fixing charges will be included in SL item NO 1 of BOQ. |
| 191 | (a) Fan belt all as per manufactures recommendations |
| 192 | (b) supply only Coupling main alternator |
| 193 | (c) supply only Fuel filter |
| 194 | (d) supply only Oil Filter |
| 195 | (e) supply only Air Filter |
| 196 | (f) Fuel tank cleaning |
| 197 | (g) Cleaning / Descaling of radiator internally and externally . |
| 198 | (h) Servicing of self starter |
| 199 | (j) Supply only coolant filter. Make Fleetguard. |
| 200 | (k) Supply only Oil sensor. |
| 201 | (l) Supply only Coolant sensor. |
| 202 | Capacity of DG set/DD Pump Set 100 KVA/133 HP 1. As per maintenance schedule prescribed in repair and maintenance manual (Repair & maintenance should be carried out by the qualified and experianced mechanic from the servicing centre who is conversant with the DG set and report should be submitted by the contractor)2. Rate quoted by the contractor includes the fixing charges for replacement of parts specified in relevant item here in after. 3. The tenderer shall produce qualification and experiance cerificate of the mechanic to the Engineer in charge and approved personal only will be allowed to carried out the work. Checking and servicing includes the following :-(i) Lubricant oil leaking.(ii) Operation and repairs to lubricant oil leakage and cooling system leakage, radiator operation with coolant, hoses and connection, belt connection and tension. Fan hub drive pulley and water pump operation and cleaning of radiator cooling system.(iii) Leaking in air intake system, maintenance filter & air cleaner piping connection.(iv) Fuel line and connection, fuel injection pump, cleaning of fuel tank for removing sediments(v) Leakage in exhaust system and exhaust restriction, drain out condensate trap, cleaning & maintenance of exhaust manifold and turbo charger cap screw.(vi) Battery charging system & topping up electrolyte and maintenance of specific gravity(vii) Cleaning of engine tighten of all nut bolt washer and unusual vibration.(viii) Checking to electric connection & smooth operation of generator control panel, greasing to all bearing and movable part, measurement and recording winding insulation resistance cleaning up complete generator/alternator. |
| 203 | Supply only following parts of DG set specified under ser item No 3 all as per recommendation of manufacturer & all as directed NOTE:- Taking down & fixing charges will be included in SL item NO 3 of BOQ. |
| 204 | (a) supply only Fan belt |
| 205 | (b) supply only Fuel filter |
| 206 | (c) supply only Oil Filter |
| 207 | (d) supply only Carbon brush |
| 208 | (e) Cleaning / Descaling of radiator internally and externally . |
| 209 | (f) Servicing of self starter |
| 210 | Capacity of DG set 62.5/60/50 KVA KVA 1. As per maintenance schedule prescribed in repair and maintenance manual (Repair & maintenance should be carried out by the qualified and experianced mechanic from the servicing centre who is conversant with the DG set and report should be submitted by the contractor)2. Rate quoted by the contractor includes the fixing charges for replacement of parts specified in relevant item here in after. 3. The tenderer shall produce qualification and experiance cerificate of the mechanic to the Engineer in charge and approved personal only will be allowed to carried out the work. Checking and servicing includes the following :-(i) Lubricant oil leaking.(ii) Operation and repairs to lubricant oil leakage and cooling system leakage, radiator operation with coolant, hoses and connection, belt connection and tension. Fan hub drive pulley and water pump operation and cleaning of radiator cooling system.(iii) Leaking in air intake system, maintenance filter & air cleaner piping connection.(iv) Fuel line and connection, fuel injection pump, cleaning of fuel tank for removing sediments(v) Leakage in exhaust system and exhaust restriction, drain out condensate trap, cleaning & maintenance of exhaust manifold and turbo charger cap screw.(vi) Battery charging system & topping up electrolyte and maintenance of specific gravity(vii) Cleaning of engine tighten of all nut bolt washer and unusual vibration.(viii) Checking to electric connection & smooth operation of generator control panel, greasing to all bearing and movable part, measurement and recording winding insulation resistance cleaning up complete generator/alternator. |
| 211 | Supply only following parts of DG set specified under ser item No 5 and all as per recommendation of manufacturer & all as directed. NOTE:-Taking down & fixing charges will be included in SL NO 5 of BOQ. |
| 212 | (a) supply only Fuel filter |
| 213 | (b) supply only Oil Filter |
| 214 | (c) Fuel tank cleaning |
| 215 | (d) Cleaning / Descaling of radiator internally and externally . |
| 216 | (e) Servicing of self starter |
| 217 | Capacity of DG set 30 to 40 KVA 1. As per maintenance schedule prescribed in repair and maintenance manual (Repair & maintenance should be carried out by the qualified and experianced mechanic from the servicing centre who is conversant with the DG set and report should be submitted by the contractor)2. Rate quoted by the contractor includes the fixing charges for replacement of parts specified in relevant item here in after. 3. The tenderer shall produce qualification and experiance cerificate of the mechanic to the Engineer in charge and approved personal only will be allowed to carried out the work. Checking and servicing includes the following :-(i) Lubricant oil leaking.(ii) Operation and repairs to lubricant oil leakage and cooling system leakage, radiator operation with coolant, hoses and connection, belt connection and tension. Fan hub drive pulley and water pump operation and cleaning of radiator cooling system.(iii) Leaking in air intake system, maintenance filter & air cleaner piping connection.(iv) Fuel line and connection, fuel injection pump, cleaning of fuel tank for removing sediments(v) Leakage in exhaust system and exhaust restriction, drain out condensate trap, cleaning & maintenance of exhaust manifold and turbo charger cap screw.(vi) Battery charging system & topping up electrolyte and maintenance of specific gravity(vii) Cleaning of engine tighten of all nut bolt washer and unusual vibration.(viii) Checking to electric connection & smooth operation of generator control panel, greasing to all bearing and movable part, measurement and recording winding insulation resistance cleaning up complete generator/alternator. |
| 218 | Supply only following parts of DG set specified under ser item No.7 all as per recommendation of manufacturer as directed NOTE :-Taking down & fixing charges will be included in SL no 7 of BOQ. |
| 219 | (a) supply only Fan belt |
| 220 | (b) supply only Fuel filter |
| 221 | (c) supply only Oil Filter |
| 222 | (d) Fuel tank cleaning |
| 223 | (e) Cleaning / Descaling of radiator internally and externally . |
| 224 | (f) Servicing of self starter |
| 225 | Capacity of DG set 20 to 25 KVA 1. As per maintenance schedule prescribed in repair and maintenance manual (Repair & maintenance should be carried out by the qualified and experianced mechanic from the servicing centre who is conversant with the DG set and report should be submitted by the contractor)2. Rate quoted by the contractor includes the fixing charges for replacement of parts specified in relevant item here in after. 3. The tenderer shall produce qualification and experiance cerificate of the mechanic to the Engineer in charge and approved personal only will be allowed to carried out the work. Checking and servicing includes the following :-(i) Lubricant oil leaking.(ii) Operation and repairs to lubricant oil leakage and cooling system leakage, radiator operation with coolant, hoses and connection, belt connection and tension. Fan hub drive pulley and water pump operation and cleaning of radiator cooling system.(iii) Leaking in air intake system, maintenance filter & air cleaner piping connection.(iv) Fuel line and connection, fuel injection pump, cleaning of fuel tank for removing sediments(v) Leakage in exhaust system and exhaust restriction, drain out condensate trap, cleaning & maintenance of exhaust manifold and turbo charger cap screw.(vi) Battery charging system & topping up electrolyte and maintenance of specific gravity(vii) Cleaning of engine tighten of all nut bolt washer and unusual vibration.(viii) Checking to electric connection & smooth operation of generator control panel, greasing to all bearing and movable part, measurement and recording |
| 226 | Supply only following parts of DG set specified under ser item No.9 and all as per recommendation of manufacturer.as directed.NOTE ;- Taking down & fixing charges will be included in SL item NO 9 of BOQ. |
| 227 | (a) supply only Fan belt |
| 228 | (b) supply only Fuel filter |
| 229 | (c) supply only Oil Filter |
| 230 | (d) Fuel tank cleaning |
| 231 | (e) Cleaning / Descaling of radiator internally and externally . |
| 232 | (f) Servicing of self starter |
| 233 | Dismantling DC dynamo/alternator of battery charging system 12/24V complete servicing including replacement of bushes, bearings, Carbon brushes, diodes any other minor parts required all as directed & fixing on engine testing/commissioning complete for any capacity of DG Set |
| 234 | Material and labour for replacement of unserviceable contactor AC operated 4 pole 415 Volt suitable for the following capacity of DG Set as per the existing in the AMF panel of same make/model. |
| 235 | (a) DG Set 200/100 kVA |
| 236 | (b) DG Set up to 62.5 kVA |
| 237 | S&F in replacement of Fuel pipe PVC metal braided of length 0.8 mtr long fitted with benzo adopters to both sides with benzo bolts & washers. |
| 238 | Repair and servicing of existing canopy of eco friendly DG Set of any capacity cleaning of internal & external parts, tightening of loose parts, replacing of unserviceable door locks and keys, replacing of damaged or burned inside sponge insulations complete all as directed. |
| 239 | Dismantling self starter engine of DG set capacity 30 KVA to 200 KVA & repairing the starter by replacing carbon brushes, bearings, solenoid coil, brush, brush holders complete rewinding, servicing refixing after repair, testing/ commissioning complete all as directed by Engr-in-Charge. |
| 240 | S&F in repair ON line battery charger 12V with TRICKLE and BOOSTING facility etc in charge mode, necessary connection from AC supply to Battery Charger and DC wiring to the battery with crocodile clip etc as required complete all as specified and as directed. |
| 241 | Supply and fixing in replacement of Door hinges for DG canopy complete all as specified and as directed. |
| 242 | Supply & filling Engine Oil 15W-40 Make : Servo/Volvo/Castrol or equivalent |
| 243 | Supply & filling Coolant premixture Make : Servo/Volvo/Castrol or equivalent |
| 244 | S&F in replacement of AVR of any type/size for DG Sets upto 500 KVA as per existing make all as specified and directed. |
| 245 | S&F in repair Battery 12 volts 180 AH, complete all as specified and as directed. MAKE:- Exide/Amaron/microtek. |
| 246 | S&F in repair Battery12 volts 80/100 AH, complete all as specified and as directed. MAKE:- Exide/Amaron/microtek. |
| 247 | M&L to repair AMF panel for DG Set of capcity 20 KVA to 500 KVA. |
| 248 | M&L in repair Start/Stop push button for DG set panel upto 500 KVA. |
| 249 | S&F in replacement of inner Air filter element of any type /size for DG Sets upto 500 KVA as per existing make, type and size all as specified and directed. |
| 250 | S&F in replacement of battery lead of colour Red and Black for +ve and -ve suitable for Battery 12 Volt 180 AH alongwith copper lugs and brass terminal of suitable size. |
| 251 | Taking down old unserviceable HPSV/ HPMV street light fittings & Supply and fixing 60 W LED street light fitting with pressure die cast housing, toughened glass and indivudial LEDs with secondary optics and IP 66 protection. |
| 252 | Dismanling and taking out the LED street light fittings any make from Pole and removing the burned out /unserviceable LED driver 25 W to 60 W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site. |
| 253 | Supply and fixing,replacement of moulded (FRP) junction box with IP 65 protection of size 300x200x80mm with 32 Amp 4 way heavy duty terminal block with 06 Amp MCB SP and two number of cable entry gland of standard size with suitable MSclamp to fix with pole complete all as directed |
| 254 | Supply & Fix in replacement of GI pipe bracket on pole/ wall etc made of 40mm bore light grade GI pipe1.5 mtr long suitably bent to shape and fixed on wall/ pole for fixing street light fitting with 2 Nos suitable MS clamps of size 25 x 3 mm size incluiding bolts, nuts, washers all as specified and as directed. |
| 255 | M & L for PCC 1:3:6 type C1 with 20mm graded stone aggregate for couping of pole,filling and mass concrete of pole, make good to road surface, hard standing etc incl necessary form work all as specified and as directed |
| 256 | Taking down old unsv/burnt XLPE cable from trench/wall/pole of following size :- |
| 257 | (a) 2 C x 10 Sqmm |
| 258 | (b) 4 C x 10 Sqmm |
| 259 | (c) 4 C x 16 Sqmm |
| 260 | (d) 3.5 C x 25 Sqmm |
| 261 | (e) 3.5 C x 35 Sqmm |
| 262 | Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable legs including neccessary roadcrossing if applicable for following size :- |
| 263 | (a) 2 C x 10 Sqmm |
| 264 | (b) 4 C x 10 Sqmm |
| 265 | (c) 4 C x 16 Sqmm |
| 266 | (d) 3.5 C x 25 Sqmm |
| 267 | (e) 3.5 C x 35 Sqmm |
| 268 | S & F in replacement of 03 core sheathed of 1.5 sqmm PVC insulated cable with mulitstanded copper PVC insulated cable with multistanded copper conductor 1100 volts grade cofirming to IS 694 including drawn throgh the steel tubular pole and connection to light fitting and MCBs all as specified and as directed. |
| 269 | S & F in replacement of 03 core sheathed of 2.5 sqmm PVC insulated cable with mulitstanded copper PVC insulated cable with multistanded copper conductor 1100 volts grade cofirming to IS 694 including drawn throgh the steel tubular pole and connection to light fitting and MCBs all as specified and as directed. |
| 270 | S&F in replacement of 45 Watt post top LED light fitting, die cast aluminum graphite grey powder coated spigot, Acrylic clear diffuser, spun aluminum power coated canopy, LED connected in series and paralled combination either better heat dissipation arrangement, LED colour 3000 K + 300K, open and short circuit protection, voltage surge protection 5KV, suitable for 60mm OD pipe entry with fixing bolts, IP-65. |
| 271 | M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.incl dismantling and taking out old U/S. |
| 272 | Supply & fix in replacement of LED bollard 9 watt with opal acrylic diffuser and IP 65 protection |
| 273 | Supply & fix in repai/replacement of Driver suitable for LED bollard 9 watt |
| 274 | M & L excavation in trenches in soft/loose soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed. |
| 275 | M & L for returning, filling in trenches incl spreading leveling watering and well ramming in layers with soft/loose soil not exc 25 cm thick in each layer complete as specified and as directed |
| 276 | M & L for removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed |
| 277 | M & L for sand cushioning with a layer of river sand 23 cm thick under and above the cable complete all as specified and as directed |
| 278 | S & L sub class burnt bricks for cable protection complete as specified as directed |
| 279 | Maintenance / servicing, cleaning, descaling of solar water heating system complete of capacity 100/200 Ltr per day with 02 Nos of collector of any size 01 No of stainless steel tank and 01 No of plastic make up tank 500 Ltr by replacement of washers, gasket, adaptor and worn out nut bolt, GI fitting for water pipe line 20/25 mm dia for inlet and outlet of stainless steel tank / collector /water make up tank and making fully leak proof by brazing / welding of the inner container for arresting leakages complete and testing for satisfactory performance all as specified and directed. |
| 280 | Maintenance / servicing, cleaning, descaling of solar water heating system complete of capacity 201/300 Ltr per day with 02 Nos of collector of any size 01 No of stainless steel tank and 01 No of plastic make up tank 500 Ltr by replacement of washers, gasket, adaptor and worn out nut bolt, GI fitting for water pipe line 20/25 mm dia for inlet and outlet of stainless steel tank / collector /water make up tank and making fully leak proof by brazing / welding of the inner container for arresting leakages complete and testing for satisfactory performance all as specified and directed. |
| 281 | Replacement of broken glass of solar flat plate collector of size 206 cm x 105 cm x 4 mm thick (L x B x W) (or as per existing size) by new one including rubber packing complete all as specified and as directed. |
| 282 | ETC Tube 47mm dia/ 54mm dia, glass tube with copper coating fixed in repairs complete all as specified and directed. |
| 283 | Supply and fix in replacement of Timeline distribution board 40 A 3 pole /230V analog time switch including complete accessories relay contactor etc, timer with battery back up all as specified and as directed. |
| 284 | Replacement black hose pipe suitable for 20/25mm dia hot/cold water pipe for solar hot water system all as specified by Engr -in Charge |
| 285 | S&F in repair Electric heating element 3KW, ISI Marked threaded/cup type to SS tank of solar water heating system 100/150/200 ltrs capacity with necessary fixtures including taking out unserviceable one complete all as specified and directed by Engr-in-Charge. |
| 286 | S&F in repair Thermostat of any size and type as per existing type, ISI Marked for solar water heating system 100/150/200 ltrs capacity including taking out unserviceable one all as specified and directed by Engr-in-Charge. |
| 287 | Supply installation, testing and commissioning of LED Solar Street light All IN ONE TYPE with inbuilt battery, SPV Module of capacity 12 Watt of light source and 12 watt SPV panel, IP 65 protection, Lumionous efficacy 120 Lm /watt, Colour temperature 6000 K, battery 12.8 V, 12 AH including charging system with overload protection, light sensor devices , etc all as specified and directed. |
| 288 | Taking down old unserviceable LED Solar Street light any Type and replacment of unserviceble parts like inbuilt battery, SPV Module of capacity 12 Watt of light source and 12 watt SPV panel, IP 65 protection, Lumionous efficacy 120 Lm /watt, Colour temperature 6000 K, battery 12.8 V, 12 AH including charging system with overload protection, light sensor devices, wiring , nut/bolts/washer ets after testing and commissioning the same location , Note : 1. As per maintenance schedule prescribed in repair and maintenance manual ( authorised servicing centre who is conversant with the Solar Street light and report should be submitted by the contractor)2. Rate quoted by the contractor includes the fixing charges for replacement of parts specified in relevant item here in after. 3. The tenderer shall produce qualification and experiance cerificate of the mechanic to the Engineer in charge and approved personal only will be allowed to carried out the work 4. All speir part shall be measured and paid seperatly |
| 289 | (a)battery 12.8 V, 42 AH including charging system with overload protection, |
| 290 | (b) SPV Module of capacity 12 Watt of light source |
| 291 | (c) 12 watt SPV panel |
| 292 | (e) light sensor devices |
| 293 | (f) wiring/nut/bolt/washer/clamp etc . |
| 294 | Excavation in trenches not exceeding 1.5 m depth and not exceeding 1.5m width and getting out in Soft/loose soil for laying of pipe lines. |
| 295 | Returning, refilling incl spreading, levelling watering and well ramming in layers not exceeding 25 cm thick with any type of soil all as directed |
| 296 | Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified as directed. |
| 297 | Taking up CI/DI water mains (including all fittings), with spigot and socket ends and lead joints/Titan Joints for the following size :- |
| 298 | (a) 150 mm bore |
| 299 | (b) 100 mm bore |
| 300 | S&F DI pipe (flanged/spigot type) laid in trenches of the following sizes :- |
| 301 | (a) 150 mm dia |
| 302 | (b) 100 mm dia |
| 303 | M&L for CI/DI Specials like bends, tappers, tee pieces all sockets, all spitgot, collars, caps & plugs any size & shape as ordered by Engineer- in- charge incl testing complete as specified & directed for the following sizes:- |
| 304 | (a) Up to 150 mm bore |
| 305 | S&F in replacement of sluice valve both side flanged and ISI marked (IS-780) of sluice valve cast iron body with S/S spindle and brass fly nuts, class PN-1.6 and cast iron hand wheel and joining with nut, bolt, washers and rubber insortion packing 6mm thick etc of following sizes:- |
| 306 | (a) 100 mm dia bore |
| 307 | (b) 80 mm dia bore |
| 308 | S&F in replacement of Air release valve of existing size suitable for centrifugal pump set complete all as specified and as directed. |
| 309 | Dewatering and pumping out of existing accumulated sludge from Bar sreen chamber at STP by using external sewage disposal pump set to near by sewage disposal drain and cleaning of tank by scrapping with wire brush or any other means of on walls and bottom of tank and removing the sludge/ slits/ sand/fungus etc deposited inside the sumps/ tanks with buckets and depositing where directed followed by cleaning with bleaching water solution and fresh water and finally applying one coat of snow cem on internal and external surfaces including writing \\"Tank Cleaned (date) and due date with 10Cm size white colour letter\\" on Black back ground on external walls complete all as specifoed and direted. Location : Hebble |
| 310 | Dewatering and pumping out of existing accumulated sludge from Equilization tank at STP by using external sewage disposal pump set to near by sewage disposal drain and cleaning of tank by scrapping with wire brush or any other means of on walls and bottom of tank and removing the sludge/ slits/ sand/fungus etc deposited inside the sumps/ tanks with buckets and depositing where directed followed by cleaning with bleaching water solution and fresh water and finally applying one coat of snow cem on internal and external surfaces including writing \\"Tank Cleaned (date) and due date with 10 Cm size white colour letter\\" on Black back ground on external walls complete all as specifoed and direted. |
| 311 | Dewatering and pumping out of existing accumulated sludge from Raw sewge sump at STP by using External Sewage disposal drain and cleaning of tank by scrapping with wire brush or any other means of on walls and bottom of tank and removing the sludge/ slits/ sand/fungus etc deposited inside the sumps/ tanks with buckets and depositing where directed followed by cleaning with bleaching water solution and fresh water and finally applying one coat of snow cem on internal and external surfaces including writing \\"Tank Cleaned (date) and due date with 10 Cm size white colour letter\\" on Black back ground on external walls complete all as specifoed and direted. Please Enable Macros to View BoQ information |
| 312 | Dewatering and pumping out of existing accumulated sludge from Raw sewge sump at STP by using External Sewage disposal drain and cleaning of tank by scrapping with wire brush or any other means of on walls and bottom of tank and removing the sludge/ slits/ sand/fungus etc deposited inside the sumps/ tanks with buckets and depositing where directed followed by cleaning with bleaching water solution and fresh water and finally applying one coat of snow cem on internal and external surfaces including writing \\"Tank Cleaned (date) and due date with 10 Cm size white colour letter\\" on Black back ground on external walls complete all as specifoed and direted. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender