Tender For Repair/ Maintenance Lightening Protection System, Leds/ Lt Cables And Other Associated Work At Wsa At Af Stn Jaisalmer
Tender Value
16 Lakhs
Estimated cost
Bid Submission
18 Nov 2026
16 days left
EMD
32000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaisalmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Lightening Protection System, Leds/ Lt Cables And Other Associated Work At Wsa At Af Stn Jaisalmer
BOQ
| Sl. No. | Item Description |
| 1 | M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 25 X 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil.(b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.(e) Requisite quantity of common salt and charcoal.(f) Testing of earthing. |
| 2 | M&L for taking down of aluminium earth strip of any size and kept aside for schedule of credit or refixing at site. |
| 3 | M&L in repair aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed |
| 4 | M&L for refixing of serviceable aluminium earth strip of any size retrived from site all as specified and directed |
| 5 | M&L for taking down of GI earth strip of any size and kept aside for schedule of credit or refixing at site |
| 6 | M&L in repair galvaniased iron (GI) strip 32mm x 6 mm buried in ground/ fixed on wall/ Passed through pipe/wall incuding connected by means of exothermic brazing, nuts and bolts where required complete all as specified and directed |
| 7 | M&L for refixing of serviceable GI earth strip of any size retrived from site all as specified and directed. |
| 8 | M&L for supply and fixing in repair air termination, single pointed aluminium rod 12 mm dia and 300 mm long all as specified and as directed |
| 9 | M&L for supply and fixing in repair air termination, single pointed copper rod 12 mm dia and 300 mm long all as specified and as directed |
| 10 | M&L in repair for test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw all as specified and directed |
| 11 | M&L in repair for porceiline insulator suitable for fixing earthing strip to the wall / floor etc complete with necessary nuts, bolts and fixing material complete all as specified and as directed |
| 12 | Supply and fixing in replacement of earth resistance marking plate fabricated from MS plate not less than 3mm thick, in square shape of size 200x200mm, fixed to equal angle of size 20x20x3mm of length 0.75 mtr, 0.30 mtr shall be embedded in PCC of 1:2:4, type B-1, using 15mm stone aggregate of size 200x200x300mm below ground level in and including necessary earth work duly writing of earthing No and details of earth, painted with applicable colour code for conventional/ chemical earthing complete all as specified and directed |
| 13 | M&L for surface Point wiring in stove enamelled steel conduit of suitable size complete with 1.5 sqmm PVC insulated unsheathed single core multistranded copper conductor FRLS cable (Phase and neutral) 1100 V grade for one light /fan/buzzer/soket outlet point controlled by one switch including continuous 1.5 sqmm copper conductor, stranded (green colour, earth), PVC insulated unsheathed earth wire to common earth and connected to earth dolly to be terminated to including complete all as specified and directed for One light point controlled by one way switchNote : Unit rates quoted by contractor shall be deemed to included for cutting chases in walls and making good in cement morter (1:3) and finishing the surface to match with exisiting surface where required |
| 14 | Supply and fixing in repair Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed |
| 15 | Supply and fixing in repair flame proof, CIMFR certified LED Flood lights not less than 60 watt, Flame Proof light in die cast aluminium housing with heat resistant toughened glass complete recommended for explosive storage complete with all fixing arrangments at site and as specified. |
| 16 | Taking down of old unserviceable LT cables of size 25sqmm 4 core to 300 sqmm 3.5 core and kept in safe custody for schedule of credit/ relaying complete all as specified and directed |
| 17 | M&L for Relaying of LT cables after, jointing or necessary repair work and testing XLPE insulated PVC outer seathed and PVC inner sheath, galvanised steel strips armoured, and reconnecting the cable from over head line and panel suitable for rated voltage of 1100 Volts grade 25 sqmm to 120 sqmm 4/3.5 Core and laid in treches/ducts/pipe or under road/ on wall/pole all as required and directed at site. Note: excavation and earth work joints will be measured and paid seprately |
| 18 | Supply, laying or fixing or passing through GI pipe, HDPE (DWC pipe) commissioning and testing of PVC / XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of the following cross section area including suitable size lugs including taking out /dismantling of existing cable. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:- Make: Polycap/KEI/Finolex or equivalant |
| 19 | All as per item Sr No. 18.00 here-in before but 10 Sqmm 2 core |
| 20 | All as per item Sr No. 18.00 here-in before but 10 Sqmm 4 core |
| 21 | All as per item Sr No. 18.00 here-in before but 16 Sqmm 4 core |
| 22 | All as per item Sr No. 18.00 here-in before but 50 Sqmm 3.5 core |
| 23 | All as per item Sr No. 18.00 here-in before but 120 Sqmm 3.5 core |
| 24 | M&L in repair for GI Tubes, of following size, light grade, galvanised with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed. |
| 25 | All as per item Sr No. 24.00 here-in before but 40 mm bore |
| 26 | All as per item Sr No. 24.00 here-in before but 50 mm bore |
| 27 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as directed at site. |
| 28 | Supply and lay in repair for double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 (Part I and II) for protection of underground cables of following size nominal outer dia & nominal inner dia with all fittings laid in trenches/ road/ nallah of fixed along wall for cable protection complete all as specified and as directed. |
| 29 | All as per item Sr No. 28.00 here-in before but Nominal outer dia 63 mm & nominal inner dia 50 mm dia up to 16 Sqmm cable |
| 30 | All as per item Sr No. 28.00 here-in before but nominal outer dia 90 mm & nominal inner dia 76 mm dia for 50 sqmm cable |
| 31 | All as per item Sr No. 28.00 here-in before but nominal outer dia 120mm & nominal inner dia 103.5 mm dia for 120 Sqmm cable |
| 32 | M&L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 33 | Taking down existing rusted/worn out MS cross arm, angle, clamps, nuts, bolts and washers and supply and fixing new MS Cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide primer and one coat of aluminium paint complete all as specified and directed by Engr in charge. |
| 34 | S & F in repair Mild steel, plain, black sheet of 1.6mm thick sheet in wall cladding, steel gates, making cover of DBs/Meters/switch boards and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc in and including providingt of one coat of red oxide two coats of smoke grey paint after preparation of surface of any type and size complete all as required at site. |
| 35 | Material and labour for providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface complete all as specified and directed by Engr in charge. |
| 36 | M&L for cutting of black top cover of existing road upto 0.6 mtr depth and upto 45cm wide for laying of UG cable and pipe line, refilling and making good after laying UG cable and pipe line with PCC 1:3:6 upto 30cm from top of the road surface complete all as specified and directed by Engr - in-charge |
| 37 | Supply, installation, commissioning and testing of cubical, outdoor type CPRI approved LT bus bar Box totally enclosed weather and vermi proof, fully compartmentalised made out of 3.15 mm thick CRCA sheet for load bearing and 2 mm thick for non load bearing portions, protection of enclosure IP-66 complete with two coat synthetic enamel paint over one coat of red oxide primer, locking arrangement, front size and rear side opening arrangement of suitable size, mounted on angle iron stand of angle size 50x50x6mm having min height 45cm from floor level, excavation and earth work, PCC foundation ( mini 45 cm hight from GL), making all incoming and out going connection with suitable size copper cable including cable lugs, cable gland etc including taking down with consisting the following items:-. (a) 4 Nos bus bar of equal size made by copper conductor with PVC insulated coloured heat shrinkabal type sleeves , rating bus bar 400 Amps , mounted on non cracking resin type insulator - 1 Set with suitable capacity of CT,s , Ammeter, volt meter, frequincy meter, selector switch and indication lamp , LED indication lamps for ON, OFF & RYB, etc(b) MCCB ,3 phase and neutral, 415 V thermal magnetic type, 4 poles, rating 250 Amps , with rupturing capacity 36 KA - 1 No (incoming). |
| 38 | Supply, fabrication, errection, installation, testing and commissioning of cubical, outdoor type CPRI approved LT panel totally enclosed weather and vermi proof, fully compartmentalised made out of 3.15 mm thick CRCA sheet steel for load bearing and 2 mm thick for non load bearing portions. Protection of enclosure IP-54 complete with two coat enamel paint over one coat of red oxide including suitable angle flat iron frame work for supports, excavation earth work, PCC foundation ( mini 45 cm hight from GL) , making all incoming and out going connection with suitable size copper cable including cable lugs , cable gland etc including taking down with consisting the following items. (a) 4 Nos bus bar of equal size made by copper conductor with PVC insulated coloured heat shrinkabal type sleeves , rating suitable size bus bar mounted on non cracking resin type insulator - 1 Set with suitable capacity of CT,s , Ammeter , volt meter , frequincy meter, selector switch and indication lamp , LED indication lamps for ON, OFF & RYB, etc. Location: near DB No. 14 (b) MCCB ,3 phase and neutral, 415 V thermal magnetic type, 4 ploes, rating 400 Amps , with rupturing capacity 36 KA - 1 No (incoming). (c) MCCB ,3 phase and neutral, 415 V thermal magnetic type, 4 ploes, rating 250 Amps , with rupturing capacity 25 KA - 1 Nos (Outgoing). (d) MCCB ,3 phase and neutral, 415 V thermal magnetic type, 4 ploes, rating 200 Amps , with rupturing capacity 25 KA - 2 Nos (Outgoing). (e) MCCB ,3 phase and neutral, 415 V thermal magnetic type, 4 ploes, rating 100 Amps , with rupturing capacity 25 KA - 1 Nos (Outgoing). |
| 39 | Supply, fabrication, errection, installation, testing and commissioning of cubical, outdoor type CPRI approved LT panel totally enclosed weather and vermi proof, fully compartmentalised made out of 3.15 mm thick CRCA sheet steel for load bearing and 2 mm thick for non load bearing portions. Protection of enclosure IP-54 complete with two coat enamel paint over one coat of red oxide including suitable angle flat iron frame work for supports, excavation earth work, PCC foundation ( mini 45 cm hight from GL) , making all incoming and out going connection with suitable size copper cable including cable lugs , cable gland etc including taking down with consisting the following items.(a) 4 Nos bus bar of equal size made by copper conductor with PVC insulated coloured heat shrinkabal type sleeves , rating suitable size bus bar mounted on non cracking resin type insulator - 1 Set with suitable capacity of CT,s , Ammeter , volt meter , frequincy meter, selector switch and indication lamp , LED indication lamps for ON, OFF & RYB, etc. Location: near boundary wall(b) MCCB ,3 phase and neutral, 415 V thermal magnetic type, 4 ploes, rating 250 Amps , with rupturing capacity 36 KA - 1 No (incoming). (c) MCCB ,3 phase and neutral, 415 V thermal magnetic type, 4 ploes, rating 100 Amps , with rupturing capacity 25 KA - 2 Nos (Outgoing). (d) MCCB ,3 phase and neutral, 415 V thermal magnetic type, 4 ploes, rating 63 Amps , with rupturing capacity 25 KA - 2 Nos (Outgoing). (e) Supply and fixing of nature switch smart timer based Automatic street light control panel. The panel should be suitable enough to take 3 phase load of 25 KW with 3 Nos incoming-ougoing MCBs of 63 Amps & 3 nos. Contactors (2 Pole/3 pole) of 40 Amps & Circuit wiring (Copper) of 16 Sqmm. Nature switch timer smart timer should be maintannace -free in design and settings accessible via a mobile app )with bluetooth connectivity). The mobile App should allow users to customize the ON & Off timing based on nature light (Sensor), Local Sunset/Sunrise (AStro) and time. The Mobile App should also have facility to set input Voltage range. The smart timer along with suitable Power Contactors and incoming-outgoing MCBs should be enclosed. The circuit should also have provision for manual operartion (Sensor By pass option) & in 3 phase model, contolling current phase selection option (at least from 2 phases) . Model No : Navdeep-66-25KW3P |
| 40 | Taking out existing PCC LT electric poles of any length including breaking of cement concrete, necessary excavation and earth work, dismantling cross arms, M.S. clamps, insulators etc and carefully taking down existing over head conductors. |
| 41 | Supply and erecting in repair steel tubular poles complete with cast iron base plate, finial taper plug , bolts Nuts & screws complete all as specified type 410 SP 31 of 9 mtr long including painting of pole with one coat red oxide primer & two coats of aluminum paint & emebeded portion shall be painted with two coat of black bituminous paint all as specified in IS with following specifications:-(i) Excavation in trenches in any types of soil ,returning filling in & well ramming including watering and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points.(ii PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in foundation bedding of size 600x600mm, 200mm base all as specified and directed .(iii) PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as upto ground level of size 600x600mm for casing of pole upto planting depth.(iv) PCC (1:2:4) type B-2 using 20mm graded stone aggregate as in coping including necessary form work above GL level. (v) Writing pole No with yellow shade on black base using synthetic enamel paint having height of words exc 5 cm as directed by Engr-in-charge. |
| 42 | Supply, fixing and connecting in repair elastomer insulated, flat,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size1.5sqmm, 3 core, confirming to IS 694-1990 complete all as specified and directed |
| 43 | S&F in replacement 3 Layer PPR Pipes, UV stabilised having thermal stability upto 93 degree centrigrade complete and fixed with the pole by providing FI clamps, nuts and bolts of size 25x25x3mm with nuts & bolts for protection of connecting wires, connection from junction box to light fittings, complete for outer dia 20 mm (PN-16) |
| 44 | Supply and fix in repair cable junction box with new pole mounted polycarbonate cable Junction box for steet light with IP-67 protection with cable gland, halogen free and weather proof with metric knockouts for cable entry for outdoor installation of approx size 225 mm x 295mm x 122 mm with front door opening system including terminals for one incoming and two outgoing cables of size 16/35 sqmm 4 core, one MCB SP 3 to 6 Amp 240V AC with mounting clamp of flat iron, nut, bolt and washers complete all as specified and directed . Make of junction box - Hensel or equivalant as approved by GE. |
| 45 | Supply and fix in repair cable junction box with new pole mounted polycarbonate cable Junction box for steet light with IP-65 protection with cable gland, halogen free and weather proof with metric knockouts for cable entry for outdoor installation of approx size 300mm x 450mm x 170 mm with front door opening system including terminals for one incoming and two outgoing cables of size 50/70 sqmm 3.5 core, one MCB SP 3 to 6 Amp 240V AC with mounting clamp of flat iron, nut, bolt and washers complete all as specified and directed . Make of junction box - Hensel or equivalant as approved by GE. |
| 46 | Material and labour for painting to PCC pole of HT/ LT over head line and all MS clamps, cross arm work on poles with one coat of superior aluminium paint on iron surfaces and synthetic enamel paint on PCC pole surface from top to bottom including necessary preparation of surfaces and painting of alternate strip with blue paint in three strip of 30cm each up to 1.5mtr above PCC benching/coping complete all as specified and directed by Engr in charge. |
| 47 | Material and labour for painting to steel tubular pole/Rail Pole, swan neck pole of HT/ LT over head line and all MS clamps, cross arm work on poles with one coat of superior aluminium paint including necessary preparation of surfaces and painting of alternate strip with black and blue for LT and Black and red for HT, synthetic enamelled paint strip 05 Nos each of 30 cm height up to 1.5mtr above PCC benching/coping complete all as specified and directed by Engr in charge |
| 48 | S&F LED flood light of capacity 150 watt, aesthetically design, having epoxy powder coated pressure die cast aluminium housing with IP 66 protection efficient high output emitter LED for better thermal management of capacity 150W(5700K CCT) , individuals LED's should have lenses for better throw across, system luminous efficacy lm/w grater than or equal to 100lm/w, high efficiency long life LED module with SMD LED package mounted on MCPCB, viewing angle 120 degree, high quality toughened glass cover, IK 07 powered by 02 Nos , inetgral , isolated electronic LED drivers (SMPS based constant current supply) with lower THD output open/short circuit protection, over voltage protection, surge voltage, protection with SPD not less than 10 KV and other sagety test as Per IS-15885 part -2/sec 13, the LED flood light should be LM 79 report and IES file, in and including taking down of old unserviceable light fitting complete all as specified and directed |
| 49 | Supply and fixing in repair energy efficient LED street light fittings of capacity not less than 70 Watt, pressure die cast alluminium housing & toughened glass with IP-66 degree of protection , individuals LED's should have lenses for better throw across &along road range 140-280 volts fittings should be provided 10 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector inbuilt in driver for maximised protections, should have lumens output of 110 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections all as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysNov 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender