Heavy Industries and Public Enterprises Government Departments Closing in 5 days TDR #58284898

Tender For Fire Hydrant System At Rubber Park Irapuram- General Electrical Work

Issued by Government Departments · Ernakulam, Kerala
Tender Value
4.14 Crore
Estimated cost
Bid Submission
06 Nov 2026
5 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
8850
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Fire Hydrant System At Rubber Park Irapuram- General Electrical Work

BOQ

Name of Work:- Fire Hydrant System at Rubber Park Irapuram- General Electrical Work
Sl. No. Item Description
1Electrical works
2OD392649/2025-2026Obtaining statutary approval from Kerala State Electrical Inspectorate [KSEI], including preparation of all statutory documents,Soil Test, drawings, scheme approvals completion certificates, test reports of metering and protection devices /equipments and arranging inspection, obtaining NOC / energization certificate etc, including liaison with concerned departments for energisation of entire electrical installations with Transformers, MSB, sets etc. compete as required.Providing and fixing laminated SLD in MSB Room All statutary fee payments shall be reimbursed after submission of necessary bills / invoice / reciept in original from the concerned departments
3OD392651/2025-2026Supply, erection, testing and commissioning of 12kV, 630A,21kA/3sec, 3 Way, oneside extensible outdoor Type IP67 SF6 Gas Insulated Ring Main Unit with Two (2) Motorized Load Break Switch (LBS) and One (1) Motorized Vacuum Circuit Breakers (VCB) wth Auxilary supply transformer installed same on civil foundations using foundation bolts as etc. complete including the cost of all materials and labour as per standards and as per the directions of the engineer in charge.
4OD392652/2025-2026"OUTDOOR HT PANEL Supply, installation, testing and commissioning of outdoor HT VCB panel unit, floor mounted, fabricated with 2mm thick CRCA sheet suitably reinforced, powder coated. Incomer One no. 11KV,630A,25kA for 3 sec HT DRAW OUT TYPE VCB WITH SHUNT TRIP with suitably interlocked earth switch, having horizontal draw out and isolation. The VCB shall be fitted with motorized spring mechanism for closing ,ON, OFF LED /mechanical indication lamp, emergency trip, Microprocessor based Protection relays (3 OC & 1 SC), high speed tripping relay, trip circuit supervision relay, safety shutter etc. The breaker shall be complete with closing coil, tripping coil and shunt trip. Providing in-built battery backup of 12V 24Ah also forms part of the scope. The panel shall be provided with the required no. of auxiliary contacts with 4NO+4NC spare contacts. Components in each incomer panel shall also include, but not limited to the following items. 1 no. Trip neutral close (T-N-C) switch. 1 no. Analogue volt meter scaled 0-15KV with selector switch 1 no. Analogue ammeter scaled 0-50 A with selector switch 1 set On,Off, Trip, Trip healthy, spring charge indication lamp 1 set panel earth bus. 1 set Inbuilt Power pack of 110V AC input with DC output for control & indication 1 set Draw out type 3 limb, 11 kV/110V, 100VA, class 0.2, epoxy cast resin potential transformer with necessary HT & LT fuses. 1 set Epoxy resin cast CT with suitable ratio as per demand load, with 10VA, class 0.2s for metering & 1 set 15VA class 5P10, Epoxy resin cast CT for protection. 1 no Panel heater with a control switch and illumination lamp with door switch. 1 set Test terminal block. 1 set 630 A TP Aluminium bus duly sleeved with all accessories and insulators, complete as required. 1 set 8 window solid state alarm annunciator with test, acknowledge, rest push button with hooter. Including Supply,Testing and commisioning of HT TOD/NET Meter . The panel shall be subjected to all routine tests as per IS/IEC standards. CPRI Type test certificate of the identical panel shall be submitted. The VCB & panel shall be provided with all necessary standard safety features as per IS & door interlocks, such as the breaker cannot be drawn out when the breaker is in ON position, and similarly breaker cannot be closed unless it is fully in drawn in condition
5OD392653/2025-2026Supply, installation, testing and commissioning of outdoor type 630KVA 11/0.433 KV, 3 Phase, 50Hz, Copper wound, Energy Efficiency Level-2, transformer having vector group of Dyn11, first fill of oil, Cable Box on HT side and LT side, Off circuit tappings of +5% to -10% in steps of 2.5% with class F insulation and standard fittings.
6OD5495/2026-2027Supply, installation, testing and commissioning of outdoor type 500KVA 11/0.433 KV, 3 Phase, 50Hz, Copper wound, Energy Efficiency Level-2, transformer having vector group of Dyn11, first fill of oil, Cable Box on HT side and LT side, Off circuit tappings of +5% to -10% in steps of 2.5% with class F insulation and standard fittings
7OD392654/2025-2026Supply and fixing of Emergency push button station in suitable MS box neatly painted with friend glass door at ground and giving all necessary connections
8OD392655/2025-2026Supply and fixing of 125/5A CL5P10 Neutral CT with suitble CRCA sheet steelenclosure and approved colour
9OD392656/2025-2026MSB +APFC Panel For 630KVA Transformer :Fabrication Supply installation testing and commissioning of 1000A LT, floor mounted type, dust and vermin proof, free standing, CPRI Approved, cubical type construction, made out 2mm thick CRCA sheet fully compartmentalised, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel with CT Digital Multifunction meter with cast resin type CTs and indication lamps,high conductivity wroughtaluminium busbars with SMC supports, heat shrinkable sleeves etc. all connections and inter-connections including mounting the following switch gears as per SLD. Should be submiited type test certificate from CPRIIncomer:1000A 4Pole 50KA Microprocessor Based draw out type ACB with 3O/C & 1EF releases and all acessories 1nos1000/5A ,10VA,CL:1 Resin cast CT -3Nos ,1nos 500/5A 5VA CT -APFCREarth Fault Relay-1nosDigital Multi function Meter with RYB indication lamp1x100x10mm AL Bus bar for Phase & 1x50x10mm AL Bus bar NeutralOutgoings :- 400A TPN Isolator-2nos,250A TPN MCCB 1nos,315A TPN SFU with250A fuseAPFC Panel:500/5A ,5VA ,CL :1, Resin cast CT -3Nos 3nos Ammetr (Digital)1x50x10mm AL Bus Bar for Pahse & 1x25x10mm AL Bus bar for Neutral8Stage APFC Relay for 155KVA Capacitor Bank with suitable rating ProtectionMCB/MCCB,Capacitor duty contactor,wires and MPP Capaitors etc.. As per SLD
10OD5505/2026-2027MSB +APFC Panel For 500KVA Transformer :Fabrication Supply installation testing and commissioning of 800A LT, floor mounted type, dust and vermin proof, free standing, CPRI Approved, cubical type construction, made out 2mm thick CRCA sheet fully compartmentalised, duly rust inhibited, degreased, zinc phosphated and powder coating painted with approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel with CT Digital Multifunction meter with cast resin type CTs and indication lamps,high conductivity wrought aluminium busbars with SMC supports, heat shrinkable sleeves etc. all connections and inter-connections including mounting the following switch gears as per SLD. Should be submiited type test certificate from CPRI Incomer:800A 4Pole 50KA Microprocessor Based draw out type ACB with 3O/C &1EF releases and all acessories 1nos 800/5A ,10VA,CL:1 Resin cast CT -3Nos ,1nos 500/5A 5VA CT -APFCR Earth Fault Relay-1nos Digital Multi function Meter with RYB indication lamp 1x100x10mm AL Bus bar for Phase & 1x50x10mm AL Bus bar Neutral Outgoings :- 400A TPN Isolator-2nos,250A TPN MCCB 1nos,315A TPN SFU with 250A fuse APFC Panel: 500/5A ,5VA ,CL :1, Resin cast CT -3Nos 3nos Ammetr (Digital) 1x50x10mm AL Bus Bar for Pahse & 1x25x10mm AL Bus bar for Neutral 8Stage APFC Relay for 155KVA Capacitor Bank with suitable rating Protection MCB/MCCB,Capacitor duty contactor,wires and MPP Capaitors etc.. As per SLD
11OD392662/2025-2026Supply of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of 3x300sqmm HT Cable
12OD412190/2025-2026Supply of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade 3.5 core 400 sq mm
13OD412189/2025-2026Supply of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade 3.5 core 240 sq mm
14OD392661/2025-2026Supply of one No. PVC insulated and PVC sheathed armoured CU power cable of 1.1 KV grade of 3 core 95 sq mm CU UG Cable
15OD392660/2025-2026Supply of one number PVC insulated and PVC sheathed armoured CU power cable of 1.1KV grade 3 core 25 sq mm CU UG
16OD392659/2025-2026Supply of one No. PVC insulated and PVC sheathed armoured CU power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required. 3 core2.5 sq mm CU
17OD392658/2025-2026Supply of one number PVC insulated and PVC sheathed armoured CU power cable of 1.1KV grade 6core 2.5 sq mm CU UG
188.1.2Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm
198.2.2Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etcAbove 120 sq. mm and upto 400 sq. mm
208.4.2Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm
218.3.2Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm
227.1.4Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm
237.2.4 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm
247.5.4Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm
257.6.4Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm
267.8.4Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
277.6.2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm
287.8.2Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
297.6.1Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
307.7.1Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
317.1.1Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
327.8.1Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle
3310.6.4Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm
3410.5.4Supplying and making outdoor cable end termination with heat shrinkable jointing kit with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm
359.1.31 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)
369.1.29 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
379.1.13 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 95 sq. mm (38mm)
3890.12.24.6 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.25 sq mm
399.1.9 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 25 sq. mm (25mm)
4090.12.24.1 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.2.5 sq mm
419.1.2Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
4290.12.24.10Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.95 sq mm
43OD413106/2025-2026Earthing with G.I. earth plate1200 mm X 1200 mm X 10 mm thick includingaccessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
44OD413108/2025-2026Supplying and laying 50 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
455.9Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
4690.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
47OD392674/2025-2026Supply and laying of 200mm dia NP3 RCC HUME pipe, length of 2.5meters and wall thickness 40mm
4890.12.9.5Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench90/75 mm or nearest size
4990.11.1.10Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
502.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
512.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
522.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
532.11Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
541.14.2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
551.3.1Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
561.27.5Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module(125mmX125mm)
571.24.8Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.Bell push
5890.3.23.5.3Surface mounting decorative fluorescent tube light fitting complete with lamp with complete accessories duly wired up for use on 230 V AC .Surface mounting LED 20W LED Batten with out put 2000 lumen for use on 250V AC supply
59OD392672/2025-2026Providing and fixing of Insulating Elastomeric (a genric term that includesrubbers,latex and elastomeric compunds that may be natural or synthetic or a mixture or a combination of both) mat with ISI mark of 1 mtr wide and 2.5mm thick to withstand 12 KV dielectric strength as per IS 15652-2006.
60OD392671/2025-2026Providing and fixing of Insulating Elastomeric (a genric term that includesrubbers,latex and elastomeric compunds that may be natural or synthetic or a mixture or a combination of both) mat with ISI mark of 1 mtr wide and 2mm thick to withstand 1.1 KV dielectric strength as per IS 15652-2006
61OD392670/2025-2026Supply & fixing shock treat chart duly mounted on a wooden frame with 5mm thick glass as required. (approximate front area 1.20sq.metre) in English, Hindi & Malyalam
622.21Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
632.22Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
64OD392669/2025-2026Supply and fixing 4.5 KG carbon dioxide (CO2) type fire extinguisher cylinder of fully charged confirming to IS 2878 -1976 as required.
65OD392668/2025-2026Supply and Installation of set of 4 Nos. 9.5Litre capacity GI bucket painted in post office red colour with prior coat of red-oxide paint and written with white paint FIRE and mounted on MS angle iron frame with bracket of appropriate size & capacity including filling sand as required.
667.10Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
677.9Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
68OD412182/2025-2026Supplying and installation of Suitable MS Cable tray through wall, floor, for laying 3x95sqmm cu ug cable &25x6mm GI Strip ,using MS angle and MS flat of suitable size with necessary supports including painting with 2coats of synthetic enamel over zinc chromate metal primer etc complete as required as per the site requirement as directed by Engineering charge
691.24.4Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
70OD392666/2025-2026Fabrication,supply,installation testing and commissioning of electric control panel ofcubical construction,floor mounted type,fabricated out of 2mm thick CRCAsheet,compartmentalized withhinged lockable doors,dust and vermin proof,powder coated of approved shade after 7 tank treatment process,cable alley,inter connected with suitable size copper conductor cable solid copper strip,having switch gears and accessories,mountings and internal wiring,earth terminals,numbering etc complete incomplete as per CPWD specification with following incoming and outgoing suitable fas required: INCOMING:400A TPN Isolator with VIF Meter operation on 415 V,3 phase 50 Hz Ac supply,with enclosure protection class IP 42. Aluminium bus bar 500A. OUTGOING MAIN FIRE PUMP:250A TPN Isolator with fully automatic star/delta starter suitable for suitable 120HP pump with all accessories and internal wiring required for automatic operation, JOCKEY PUMP: 125 A,TPN SFU,with suitable ,50HP fully automatic star/delta starter with all accessories and internal wiring required for automatic operation SPARE FEEDER:250A TPN Isolator with Provision for fixing Fully automatic starter etc..
71OD38222/2026-2027 Fabrication,supply,installation testing and commissioning of electric control panel of cubical construction,floor mounted type,fabricated out of 2mm thick CRCA sheet,compartmentalized withhinged lockable doors,dust and vermin proof,powder coated of approved shade after 7 tank treatment process,cable alley,inter connected with suitable size copper conductor cable solid copper strip,having switch gears and accessories,mountings and internal wiring,earth terminals,numbering etc completeincomplete as per CPWD specification with following incoming and outgoingsuitable fas required: INCOMING:400A TPN Isolator with VIF Meter operation on415 V,3 phase 50 Hz Ac supply,with enclosure protection class IP 42. Aluminium busbar 500A. OUTGOING MAIN FIRE PUMP:250A TPN Isolator with fullyautomatic star/delta starter suitable for suitable 120HP pump with all accessories andinternal wiring required for automatic operation, JOCKEY PUMP: 125 A,TPNSFU,with suitable ,50HP fully automatic star/delta starter with all accessories and internal wiring required for automatic operation SPARE FEEDER:250A TPN Isolator with Provision for fixing Fully automatic starter etc.. DIESEL ENGINE CONTROL:Control for diesel engine comprising -Automatic /Manual selector switch and 3 attempts starting device ,timers and relays as required,push buttons,start/stop in manual mode indicating lamp for high/low lub.oil pressure,high water remp and engine on indication,Battery charger suitable for 12V/24V DC with boost and trickle selector switch,0-30 V DC volt meter,and 0-20A DC ammeter.Allstandard relays for automatic operation of diesel engine.
72OD392673/2025-2026Dismantling of Concrete road ,for laying RCC Hume pipe ,and reconstruction of concrete road as per std.
73OD5516/2026-2027Retrieving of one number power cable of 11 KV grade of 300 sq.mm size including excavation and refilling the trench etc as required.
74OD38206/2026-2027Supply and fixing of 24hr timer with suitable Metal enclosure
75CIVIL WORKS - TRANSFORMER BASE AND FENCING
762.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
777.1.1Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand)
785.1.2Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources)
795.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
805.9.6Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
814.1.5Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mmnominal size derived from natural sources)
8216.70.1Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia4 mm
83OD39177/2026-2027Providing and laying stone aggregate 40 mm nominal size.
8413.52.1Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
8510.1Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
8610.2Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
87Civil Works- TRENCH FOR PIPELINE, WATER TANK AND PUMP HOUSE
882.25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
892.31Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
902.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil
914.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources)
924.1.5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mmnominal size derived from natural sources)
9311.3.1Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominalsize stone aggregate
945.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete
955.1.2Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources)
965.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
9760.2.1EARTH WORK FILLING- Supplying contractors own earth including cost ofconveyance and royalty and filling (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
987.1.1Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand)
9950.6.2.1Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
10013.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
10113.48.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm
10210.16.2Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished seamless type tubes
10312.50Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoidscratches during transportation and should be supplied in single length upto 12 metreor as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/selftapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch inhorizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shape wherever required.
1049.48.2Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
10513.52.1Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
10616.33.22.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete ( tack coat to be paid for separately):With paving Asphalt grade VG - 30 with no solvent
10716.36.1Providing and laying Bitumen Penetration Macadam with hard stone aggregate of quality, size and grading as specified, with bitumen of suitable penetration grade, including required key aggregate as specified, spreading coarse aggregate with the help of self propelled/ tipper tail mounted aggregate spreader and applying bitumen by a pressure distributor and then spreading key aggregate with the help of aggregatespreader complete, including consolidation with road roller of minimum 8 to 10 tonne capacity to achieve specified values of compaction and surface accuracy:For 50mm compacted thickness using coarse aggregate of size 50-20 mm graded @ 0.60 cum per 10 sqm key aggregate of size 12.5 mm graded @ 0.15 cum per 10 sqm. With paving asphalt grade VG - 10 @ 50 kg/ 10 sqm.
10816.78.1Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specifiedthickness with motor grader on prepared surface and compacting with vibratorypower roller to achieve the desired density, complete as per specifications anddirections of Engineer-in- Charge.With Material conforming to Grade - I ( size range75 mm to 0.075 mm) having CBR Value- 30
10916.31.1.1Providing and applying tack coat using bitumen emulsion conforming to IS : 8887, using emulsion pressure distributor including preparing the surface & cleaning with mechanical broom. With rapid setting bitumen emulsion On W.B.M / W.M.M. @ 0.4kg/sqm
11016.31.1.2Providing and applying tack coat using bitumen emulsion conforming to IS : 8887, using emulsion pressure distributor including preparing the surface & cleaning with mechanical broom. With rapid setting bitumen emulsion On bituminous surface @ 0.25kg/sq
11185.101Supply of MS plates confirming to IS 2062GrB including cost of conveyance charges
11285.108Fabrication , erection and commissioning of Structural Steel Embedded parts in IS2062 Grade and accessories as per approved specifications, drawings and directions of deptl officer at site including cost of labour , machinery , incidental and handling charge etc complete but exculding cost of materials already supplied
11310.2Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
1142.33.2Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58284898
AUTHORITY Government Departments
TENDER VALUE 4.14 Crore
LAST DATE 06-11-2026
Authority
Authority Name Steel Industrials Kerala Limited
Work Description Tender for Fire Hydrant System At Rubber Park Irapuram- General Electrical Work
Basic Detail
Tender No SILK/SFU/04/2026-27/28
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 30 Oct 2026
Submission Date 06 Nov 2026
Open Date 07 Nov 2026
Finance
Tender Value 4.14 Crore
Tender Fee 8850
EMD 1 Lakhs
Exemption Available
Document List
2ae3209b-26cf-426b-b72d-c7b7ef065cc5.html
BOQ_1505491.xls
GCC.pdf
PROFILE.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

2ae3209b-26cf-426b-b72d-c7b7ef065cc5.html

xls

BOQ_1505491.xls

pdf

GCC.pdf

pdf

PROFILE.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender