Power Government Departments Closing in 6 days TDR #58284857

Tender For Nabard-Ridf Tranche Xxxi (2025-26)- Development Of Rapid Response Units, Forest Station Complex And Other Infrastructure Under Central Circle

Issued by Government Departments · Ernakulam, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
06 Nov 2026
6 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
8850
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Nabard-Ridf Tranche Xxxi (2025-26)- Development Of Rapid Response Units, Forest Station Complex And Other Infrastructure Under Central Circle

BOQ

Name of Work:- NABARD-RIDF Tranche XXXI (2025-26)- Development of Rapid Response Units, Forest Station Complex and other infrastructure under Central Circle
Sl. No. Item Description
1VAZHACHAL DIVISION
2CONSTRUCTION OF BACHELOR QUARTERS BUILDING AT EZHATTUMANGALAM FSIN ATHIRAPALLY RANGE
3CIVIL WORKS
42.1.1Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m inwidth as well as 10 sqm on plan including disposal of excavated earth up to 50 m andlift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
52.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.All kinds of soil
62.25Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m
72.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil
84.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources)
97.1.1 Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand
107.2.1Random rubble masonry with hard stone in superstructure above plinth level and uptofloor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceilinglevel and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)
115.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources)
125.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete
135.9.21Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mmthick
145.3Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (ZoneIII) derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources).
155.9.20Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform with water proof ply 12 mmthick
165.9.19Centering and shuttering including strutting, etc. and removal of form for:Weathershade, Chajjas, corbels etc., including edges
175.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more
1810.17Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shapewith hooked ends in R.C.C. slabs or beams during laying, including painting theexposed portion of loop, all as per standard design complete.
1960.2.1EARTH WORK FILLING- Supplying contractors own earth including cost ofconveyance and royalty and filling (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
204.1.3Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarsesand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources)
2150.6.2.2Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm ornearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etccomplete
2213.4.112 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
2313.16.16 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand
2413.9.1Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neatcement.12 mm cement plaster
25OD83271/2024-2025Water proof plastering with Cement Mortar 1:4 (1 cement : 4 fine sand) 12mm thick plaster finished with a floating coat of neat cement mixed with water proofingcompound of approved make @ 2kg/m2 of mix floated hard and troweled smoothincluding all labour, material, conveyance charges etc complete
2613.26Providing and applying plaster of paris putty of 2 mm thickness over plastered surfaceto prepare the surface even and smooth complete.
2713.43.1Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer
28OD20881/2025-2026Finishing with Deluxe Multi-Surface Paint System for interiors and exteriors as permanufacturers' specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqmover primer
2911.41.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm.
3011.48.2Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm
3111.36Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer -inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm,including pointing in white cement mixed with pigment of matching shade complete
3211.40Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm ormore (thickness to be specified by the manufacturer) of Ist quality conforming to IS:15622 of approved make in all colours, shades, except white, Ivory, Grey Fume RedBrown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
3322.3Providing and laying water proofing treatment to vertical and horizontal surfaces ofdepressed portions of W.C. kitchen and the like consisting of : i) I course of applyingcement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming toIS: 2645 in recommended proportions including rounding off junction of vertical andhorizontal surface. ii) II course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarsesand) mixed with water proofing compound in recommended proportion includingrounding off junction of vertical and horizontal surface. iii) III course of applyingblown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IV course of 400micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wideand pasted to each other with bitumen @ 1.7 Kg/ sqm.
349.48.2Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
3550.9.1.1Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid forseparately), using good quality Anjili wood /jack wood
3650.9.2.1Providing and fixing paneled and glazed shutters for doors, windows and clerestorywindows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges brightfinished of required size with necessary screws, excluding panelling which will bepaid for separately, all complete as per direction of Engineerin - charge using Anjili/Jack wood
3750.9.4.1Providing and fixing paneling or paneling and glazing in paneled or paneled andglazed shutters for doors, windows and clerestory windows (Area of opening forpanel inserts excluding portion inside grooves or rebates to be measured) paneling forpaneled or paneled and glazed shutters 25 mm to 40 mm thick using good qualityAnjili/ Jack wood
3850.9.5.1Providing and fixing glazed shutters for doors, windows and clerestory windowsusing 4 mm thick float glass panes including ISI marked M.S pressed butt hingesbright finished of required size with necessary screws. Using Anjili wood/ jack wood35 mm thick shutters
399.141Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5mm (±0.2mm), made out of single piece extruded PVC profile, with mitred cut jointsand with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross sectionsize 35 x 15 mm & self driven self taping screws, the vertical door profiles to bereinforced with 40x20 mm M.S. rectangular tube of 0.8 mm, including providingEPDM rubber gasket weather seal throughout the frame, including jointing 5 mmPVC frame strip with PVC solvent cement on the back of the profile. The door frameto be fixed to the wall using 8x100 mm long anchor fasteners complete, all as permanufacturer's specification and direction of Engineer-in--charge.
409.142.135 mm thick factory made Solid panel PVC Door shutter, made out of singleNondecorative finish (matt finish)
4113.48.3Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Painting Steel work with Deluxe MultiSurface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqmover an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand andmanufacture
4213.52.1Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturer's specifications including appropriate priming coat, preparationof surface, etc. complete.On steel work
43PLUMBING WORK
4417.3.1Providing and fixing white vitreous china pedestal type water closet (European type)with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flushbend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement withspecials of standard make and mosquito proof coupling of approved municipal designcomplete, including painting of fittings and brackets, cutting and making good thewalls and floors wherever required :W.C. pan with ISI marked white solid plastic seatand lid
4517.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Washbasin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap
4617.73.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleatswith CP brass screws with concealed fitting arrangement of approved quality andcolour600 mm long towel rail with total length of 645 mm, width 78 mm andeffective height of 88 mm, weighting not less than 190 gms
4718.51.1Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore
4818.65Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102mm, height of 75 mm with concealed fittings arrangements, weighing not less than106 gms.
4950.17.1.5Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge.
5018.17.2Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) :32 mm nominal bore
5118.17.3Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) :40 mm nominal bore
5218.22.1Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:100 mm diameter
5318.52.1Providing and fixing C.P brass stop cock ( concealed) of standard design and ofapproved make conforming to IS: 893115 mm nominal bore
5418.53.1Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore
5518.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank
5650.18.7.6.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 10 Kfg/cm - Internal work- Exposed on wall
5750.18.8.3.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe10kgf /cm2
5850.18.9.8.2Providing and fixing PVC pipes includings of pipes with one step PVC solventcement, trenching and refilling & testing of joints complete as per direction ofEngineer in Charge. 75 mm dia 4 Kgf/cm2
5950.18.9.9.2Providing and fixing PVC pipes includes joints of pipes with one step PVC solventcement, trenching, refilling & testing of joints complete as per direction of Engineerin CHarge. 110 mm dia 4 Kg/cm2
6050.18.9.19.2Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 mspacing. This includes jointing of pipes with one step PVC solvent cement and testingof joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 External work - Exposed on wall
6118.32.1Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm(inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation,foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mmnominal size) and inside plastering with cement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cementcomplete as per standard design:With common burnt clay F.P.S (non modular) bricksof class designation 7.5
6251.19.ST4Supplying and installing ready made PVC Septic tank including the cost of carriage,trenching, placing at the level below ground level as specified as per the direction ofengineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparationof bed shall be paid separately) 4. 35 to 50 flush capacity
6319.32.1Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honeycomb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete asper standard design.With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5
64ELECTRICAL
651.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
661.12Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductorsingle core cable in surface/ recessed medium class PVC conduit along with 1 No 4sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing asrequired.
671.14.10Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire
681.14.2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
691.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.5/6amps switch
701.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch
711.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.3pin 5/6 amp socket outlet
721.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.6pin 15/16 amp socket outlet
731.25Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. asrequired
741.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
751.27.4Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
761.55.3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bellpoint ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. asrequired.Group C
77OD20885/2025-2026Supplying and fixing following way prewired TP&N MCB distribution board of steelsheet for 415 volts on surface/ recess complete with loose wire box, terminalconnectors for all incoming and outgoing circuits, duly prewired with suitable sizeFRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar,neutral link, earth bar, din bar, detachable gland plate,interconnections, powderpainted including earthing etc. as required.(But without MCB/ RCCB/Isolator)6 way (4+18), Double door
782.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
792.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps
802.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps
812.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
822.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
832.3.2Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
84OD20886/2025-2026 Supply and fixing 40A TP MCB in existing DB with all connections as required
851.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm
861.21.2Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm
871.21.3Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm
881.41Installation, testing and commissioning of pre - wired, fluorescent fitting/ compactfluorescent fitting of all types, complete with all accessories and tube etc. directly onceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copperconductor, single core cable and earthing etc. as required.
891.44Installation, testing and commissioning of ceiling fan, including wiring the down rodsof standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copperconductor, single core cable etc. as required
901.47Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavygauge including painting etc. as required. (Note: More than 5 cm length shall berounded to the nearest 10 cm and 5 cm or less shall be ignored)
911.50.1 Installation of exhaust fan in the existing opening, including making good the damageconnection testing, commissioning etc. as required.Upto 450 mm sweep
925.17Providing and fixing 4.00 mm dia copper wire on surface or in recess for loopearthing as required.
93OD20888/2025-2026Supplying, Installing, testing and commissioning of wall mounted Three Phase 4 wireenergy meter with a polycarbonate body having range of 10-63 A, with enclosuremade out of powder coated 16 SWG CRCA sheet suitable for fixing in surface/recesswith 3 nos. of 63A HRC fuses, 63A TPN isolator, neutral link, its interconnections,etc.The enclosure shall have lockable door with glass window and all mountingaccessories complete as required (supplying of energy meter is under KSEB scope)
94OD20889/2025-2026Supply of 200 mm sweep,900 rpm light-duty exhaust fan in plastic body with selfopening louvers working on 230 V AC supply complete with all accessories asrequired. (Make: Crompton/Havells or equivalent approved make)
95OD20890/2025-2026 Supply of IP66 streetlight luminaire made of die-cast aluminum along with driver,system wattage of 30+/- 2 watts, lumen output of luminaire greater than 3300 lumens,power factor of 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than110 lumens/watt with suitable driver, and including all necessary accessories asrequired, complete. (MakeCat No: Wipro LR02-331-XXX-57-XX, CG: LSTS-30CDL or other approved equivalent makes)
96OD20891/2025-2026Supply of single tube set LED 20W and other accessories
97OD20892/2025-2026Supply of 20W led bulkhead light fittings with all the accessories, etc., as required
98OD20893/2025-2026Supply of 1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt), Air delivery minimum 210(cubic meter/minute), 300mm downrod, 2 number canopies, shackele kit, Copper winding, 3 number blades and allremaining accessories including safety pin, nut bolts, washers suitable for 230V/240Vsingle phase AC supply,BLDC etc. complete as required make orient/havells orequivalent
995.12Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wirein 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimbleexcavation and re-filling as required.
1005.2Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc.(but without charcoal/ coke and salt) as required
101OD20894/2025-2026Supplying and fixing angle batten with20 watts led bulb and other accessories
102CONSTRUCTION OF RANGE OFFICE COMPLEX IN ATHIRAPALLY RANGE
103CIVIL WORKS
1042.1.1Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m inwidth as well as 10 sqm on plan including disposal of excavated earth up to 50 m andlift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
10515.2.1Demolishing cement concrete manually / by mechanical means including disposal ofmaterial within 50 metres lead as per direction of Engineer - in-Charge.Nominalconcrete 1:3:6 or richer mix (i/c equivalent design mix
10615.3Demolishing R.C.C. work manually / by mechanical means including stacking ofsteel bars and disposal of unserviceable material with in 50 metres lead as perdirection of Engineer -in-Charge.
10715.60Disposal of building rubbish/ malba/ similar unserviceable, dismantled or wastematerials by mechanical means, including loading, transporting, unloading toapproved municipal dumping ground or as approved by Engineer-in-charge, beyond50 m initial lead, for all leads including all lifts involved
10815.7.4Demolishing brick work manually / by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead asper direction of Engineer-in-Charge.In cement mortar
1092.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
1102.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil
1114.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources)
1127.1.1Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand
1137.2.1Random rubble masonry with hard stone in superstructure above plinth level and uptofloor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceilinglevel and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)
1145.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources)
1155.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more
1165.3Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (ZoneIII) derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources).
1175.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete
1185.9.19Centering and shuttering including strutting, etc. and removal of form for:Weathershade, Chajjas, corbels etc., including edges
1195.9.20Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform with water proof ply 12 mmthick
1205.9.21Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mmthick.
12110.17Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shapewith hooked ends in R.C.C. slabs or beams during laying, including painting theexposed portion of loop, all as per standard design complete.
12250.6.1.5Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cmor nearest available size confirming to IS 2185 Part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etccomplete
12313.9.1Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neatcement.12 mm cement plaster
124OD20483/2025-2026Water proof plastering with Cement Mortar 1:4 (1 cement : 4 fine sand) 12mm thickplaster finished with a floating coat of neat cement mixed with water proofingcompound of approved make @ 2kg/m2 of mix floated hard and troweled smoothincluding all labour, material, conveyance charges etc complete
12513.26Providing and applying plaster of paris putty of 2 mm thickness over plastered surfaceto prepare the surface even and smooth complete
12613.43.1Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer
127OD20482/2025-2026Finishing with Deluxe Multi-Surface Paint System for interiors and exteriors as permanufacturers' specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqmover primer
12822.3Providing and laying water proofing treatment to vertical and horizontal surfaces ofdepressed portions of W.C. kitchen and the like consisting of : i) I course of applyingcement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming toIS: 2645 in recommended proportions including rounding off junction of vertical andhorizontal surface. ii) II course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarsesand) mixed with water proofing compound in recommended proportion includingrounding off junction of vertical and horizontal surface. iii) III course of applyingblown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IV course of 400micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wideand pasted to each other with bitumen @ 1.7 Kg/ sqm.
12911.41.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm.
13011.46.2Providing and laying Vitrified tiles indifferent sizes (thickness to be specified bymanufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622,of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thickbed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint withwhite cement & matching pigments etc. complete.Size of Tile 600x600 mm
1318.31Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete.
13211.40Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm ormore (thickness to be specified by the manufacturer) of Ist quality conforming to IS:15622 of approved make in all colours, shades, except white, Ivory, Grey Fume RedBrown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) includingpointing the joints with white cement and matching pigments etc., complete.
1339.48.2Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
13450.9.1.1Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid forseparately), using good quality Anjili wood /jack wood
13550.9.2.1Providing and fixing paneled and glazed shutters for doors, windows and clerestorywindows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges brightfinished of required size with necessary screws, excluding panelling which will bepaid for separately, all complete as per direction of Engineerin - charge using Anjili/Jack wood
13650.9.4.1Providing and fixing paneling or paneling and glazing in paneled or paneled andglazed shutters for doors, windows and clerestory windows (Area of opening forpanel inserts excluding portion inside grooves or rebates to be measured) paneling forpaneled or paneled and glazed shutters 25 mm to 40 mm thick using good qualityAnjili/ Jack wood
13750.9.5.1Providing and fixing glazed shutters for doors, windows and clerestory windowsusing 4 mm thick float glass panes including ISI marked M.S pressed butt hingesbright finished of required size with necessary screws. Using Anjili wood/ jack wood35 mm thick shutters
1389.141 Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5mm (±0.2mm), made out of single piece extruded PVC profile, with mitred cut jointsand with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross sectionsize 35 x 15 mm & self driven self taping screws, the vertical door profiles to bereinforced with 40x20 mm M.S. rectangular tube of 0.8 mm, including providingEPDM rubber gasket weather seal throughout the frame, including jointing 5 mmPVC frame strip with PVC solvent cement on the back of the profile. The door frameto be fixed to the wall using 8x100 mm long anchor fasteners complete, all as permanufacturer's specification and direction of Engineer-in--charge.
1399.142.135 mm thick factory made Solid panel PVC Door shutter, made out of singleNondecorative finish (matt finish)
14010.16.2Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished seamless type tubes
14113.48.3Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Painting Steel work with Deluxe MultiSurface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqmover an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand andmanufacture
14213.52.1Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturer's specifications including appropriate priming coat, preparationof surface, etc. complete.On steel work
14310.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainless steeldash fasteners, stainless steel bolts etc., of required size on the top of the floor or theside of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.)
14413.4.112 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand
14513.16.16 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand
14611.48.2Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm
14711.18.3Precast terrazo tiles 22 mm thick with graded marble chips of sizes upto 12 mm, inskirting and risers of steps not exceeding 30 cm in height , on 12 mm thick cementplaster 1:3 ( 1 cement : 3 coarse sand), jointed with neat cement slurry mixed withpigment to match the shade of the tiles, including rubbing and polishing completewith tiles of :Dark shade pigment using ordinary cement
1482.25Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
149PLUMBING
15017.2.1Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked white solid plastic seat andlid
15150.17.1.5Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge.
15217.32.1Providing and fixing mirror of superior glass ( of approved quality) and of requiredshape and size with plastic moulded frame of approved make and shade with 6 mmthick hard board backing :Circular shape 450 mm dia
15317.7.8Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Surgeontype wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps withelbow including operated levers
15417.70.1Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31 mmsingle piece moulded with height of 270 mm, effective length of tail pipe 260 mmfrom the center of the waste coupling, 77 mm breadth with 25 mm minimum waterseal, weighing not less than 260 gms
15517.73.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleatswith CP brass screws with concealed fitting arrangement of approved quality andcolour450 mm long towel rail with total length of 495 mm, 78 mm wide and effectiveheight of 88 mm. weighing not less than 170 gms
15618.32.1Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm(inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation,foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mmnominal size) and inside plastering with cement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cementcomplete as per standard design:With common burnt clay F.P.S (non modular) bricksof class designation 7.5
15719.7.1.1Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand)with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick withcement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neatcement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size ) finished with a floating coat of neatcement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty)455x610 mm internal dimensions, total weight of cover and frame to be not less than38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clayF.P.S. (non modular) bricks of class designation 7.5
15818.17.2 Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) :32 mm nominal bore
15918.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank.
16018.51.1Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore
16118.53.1Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore
16218.56.1Providing and fixing PTMT pillar cock of approved quality and colour.15 mmnominal bore, 107 mm long, weighing not less than 110 gms
16350.18.7.2.1Providing and fixing PVC pipes, fittings including fixing the pipe with claps at 1.00metre spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 20 mmdia 12Kgf/cm2 - Internal work - Exposed on wall
16450.18.7.3.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer- in- Charge 25 mmdia 12 Kgf/cm2 - Internal work - Exposed on wall
16550.18.9.18.1Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 mspacing. This included jointing of pipes with one step PVC solvent cement and testingof joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 External work- Exposed on wall
16650.18.9.19.1Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2 - External work- Exposed on wall
16750.18.9.9.1Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per direction ofengineer in charge.110 mm dia 6Kgf/cm2
16818.8.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.20 mm nominal dia pipes
16918.8.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.25 mm nominal dia pipes
170ELECTRICAL WORKS
1711.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
1721.12Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductorsingle core cable in surface/ recessed medium class PVC conduit along with 1 No 4sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing asrequired.
1731.14.10Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire
1741.14.2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1751.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.5/6amps switch
1761.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch
1771.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.3pin 5/6 amp socket outlet
1781.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.6pin 15/16 amp socket outlet
1791.25Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. asrequired
1801.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1811.27.4Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1821.55.3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bellpoint ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. asrequired.Group C
1832.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
1842.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps
1852.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps
1862.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
1871.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm
1881.21.2Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm
1891.21.3 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm
1905.17Providing and fixing 4.00 mm dia copper wire on surface or in recess for loopearthing as required.
1912.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
1921.41Installation, testing and commissioning of pre - wired, fluorescent fitting/ compactfluorescent fitting of all types, complete with all accessories and tube etc. directly onceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copperconductor, single core cable and earthing etc. as required.
1931.44Installation, testing and commissioning of ceiling fan, including wiring the down rodsof standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copperconductor, single core cable etc. as required
1941.47Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavygauge including painting etc. as required. (Note: More than 5 cm length shall berounded to the nearest 10 cm and 5 cm or less shall be ignored)
1951.50.1Installation of exhaust fan in the existing opening, including making good the damageconnection testing, commissioning etc. as required.Upto 450 mm sweep
1965.12Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wirein 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimbleexcavation and re-filling as required.
1975.2Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement andwatering pipe etc.(but without charcoal/ coke and salt) as required
1982.3.2Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
199OD20488/2025-2026Supplying, Installing, testing and commissioning of wall mounted Three Phase 4 wireenergy meter with a polycarbonate body having range of 10-63 A, with enclosuremade out of powder coated 16 SWG CRCA sheet suitable for fixing in surface/recesswith 3 nos. of 63A HRC fuses, 63A TPN isolator, neutral link, its interconnections,etc.The enclosure shall have lockable door with glass window and all mountingaccessories complete as required (supplying of energy meter is under KSEB scope)
200OD20485/2025-2026Supply of 200 mm sweep,900 rpm light-duty exhaust fan in plastic body with selfopening louvers working on 230 V AC supply complete with all acc accessories asrequired. (Make: Crompton/Havells or equivalent approved make)
201OD20492/2025-2026 Supply of IP66 streetlight luminaire made of die-cast aluminum along with driver,system wattage of 30+/- 2 watts, lumen output of luminaire greater than 3300 lumens,power factor of 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than110 lumens/watt with suitable driver, and including all necessary accessories asrequired, complete. (MakeCat No: Wipro LR02-331-XXX-57-XX, CG: LSTS-30CDL or other approved equivalent makes)
202OD20486/2025-2026 Supply of single tube set LED 20W and other accessories
203OD20491/2025-2026Supply of 20W led bulkhead light fittings with all the accessories, etc., as required
204OD20487/2025-2026Supply of 1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt), Air delivery minimum 210(cubic meter/minute), 300mm downrod, 2 number canopies, shackele kit, Copper winding, 3 number blades and allremaining accessories including safety pin, nut bolts, washers suitable for 230V/240Vsingle phase AC supply,BLDC etc. complete as required make orient/havells or equivalent
205OD20490/2025-2026Supplying and fixing angle batten with20 watts led bulb and other accessories
206OD20493/2025-2026 Supply and fixing 40A TP MCB in existing DB with all connections as required
207OD20489/2025-2026 Supplying and fixing the following way prewired TP&N MCB distributionboard of steel sheet for 415 volts on surface/recess complete with loose wire box,terminal connectors for all incoming and outgoing circuits, duly prewired withsuitable size FRLS PVC insulated copper conductor up to terminal blocks, tinnedcopper bus bar, neutral link, earth bar, din bar, detachable gland plate,interconnections, powder painted including earthing, etc., as required. (But withoutMCB/RCCB/isolator) 6 way (4+18), Double door
208COMPOUND WALL
2092.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil
2104.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources)
2117.1.1Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand)
2125.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
2135.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete
2145.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more
2157.2.1Random rubble masonry with hard stone in superstructure above plinth level and uptofloor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceilinglevel and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)
21650.6.2.2Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm ornearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etccomplete
21713.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
218OD20484/2025-2026Finishing with Deluxe Multi-Surface Paint System for interiors and exteriors as permanufacturers' specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqmover primer
21913.43.1Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer
22010.16.2Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished seamless type tubes
22113.61.1Painting with synthetic enamel paint of approved brand and manufacture to give aneven shade:Two or more coats on new work
222CONSTRUCTION OF TYPE II DUPLEX QUARTERS BUILDING AT ATHIRAPALLY RANGE
223CIVIL WORKS
22415.2.1Demolishing cement concrete manually / by mechanical means including disposal ofmaterial within 50 metres lead as per direction of Engineer - in-Charge.Nominalconcrete 1:3:6 or richer mix (i/c equivalent design mix)
22515.3Demolishing R.C.C. work manually / by mechanical means including stacking ofsteel bars and disposal of unserviceable material with in 50 metres lead as perdirection of Engineer -in-Charge.
22615.60Disposal of building rubbish/ malba/ similar unserviceable, dismantled or wastematerials by mechanical means, including loading, transporting, unloading toapproved municipal dumping ground or as approved by Engineer-in-charge, beyond50 m initial lead, for all leads including all lifts involved
22715.7.4Demolishing brick work manually / by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead asper direction of Engineer-in-Charge.In cement mortar
22815.9.2Demolishing stone rubble masonry manually / by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50metres lead as per direction of Engineer -in- Charges:In cement mortar
2292.1.1Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m inwidth as well as 10 sqm on plan including disposal of excavated earth up to 50 m andlift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
2302.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.All kinds of soil
2312.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2324.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources)
2337.1.1Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand)
2347.2.1Random rubble masonry with hard stone in superstructure above plinth level and uptofloor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceilinglevel and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)
23560.2.1EARTH WORK FILLING- Supplying contractors own earth including cost ofconveyance and royalty and filling (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m
2364.1.3Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarsesand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources)
2375.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources)
2385.2.2Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up tot floor five level excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 gradedstone aggregate 20 mm nominal size derived from natural sources)
2395.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more
2405.3Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (ZoneIII) derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources).
2415.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete
2425.9.19Centering and shuttering including strutting, etc. and removal of form for:Weathershade, Chajjas, corbels etc., including edges
2435.9.20Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform with water proof ply 12 mmthick
2445.9.21 Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mmthick.
24510.17Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shapewith hooked ends in R.C.C. slabs or beams during laying, including painting theexposed portion of loop, all as per standard design complete.
24650.6.2.2Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm ornearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etccomplete
24713.16.16 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand
24813.4.112 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
24913.9.1Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neatcement.12 mm cement plaster
250OD20897/2025-2026Water proof plastering with Cement Mortar 1:4 (1 cement : 4 fine sand) 12mm thickplaster finished with a floating coat of neat cement mixed with water proofingcompound of approved make @ 2kg/m2 of mix floated hard and troweled smoothincluding all labour, material, conveyance charges etc complete.
25113.26Providing and applying plaster of paris putty of 2 mm thickness over plastered surfaceto prepare the surface even and smooth complete.
25213.43.1Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer
253OD20898/2025-2026 Finishing with Deluxe Multi-Surface Paint System for interiors and exteriors as per manufacturers' specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqmover primer
25422.3Providing and laying water proofing treatment to vertical and horizontal surfaces ofdepressed portions of W.C. kitchen and the like consisting of : i) I course of applyingcement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming toIS: 2645 in recommended proportions including rounding off junction of vertical andhorizontal surface. ii) II course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarsesand) mixed with water proofing compound in recommended proportion includingrounding off junction of vertical and horizontal surface. iii) III course of applyingblown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IV course of 400micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wideand pasted to each other with bitumen @ 1.7 Kg/ sqm.
25511.40Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm ormore (thickness to be specified by the manufacturer) of Ist quality conforming to IS:15622 of approved make in all colours, shades, except white, Ivory, Grey Fume RedBrown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) includingpointing the joints with white cement and matching pigments etc., complete.
25611.41.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm.
25711.48.2Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm
25811.36Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer -inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm,including pointing in white cement mixed with pigment of matching shade complete.
2599.48.2Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
26050.9.1.1Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid forseparately), using good quality Anjili wood /jack wood
26150.9.2.1Providing and fixing paneled and glazed shutters for doors, windows and clerestorywindows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges brightfinished of required size with necessary screws, excluding panelling which will bepaid for separately, all complete as per direction of Engineerin - charge using Anjili/Jack wood
26250.9.4.1Providing and fixing paneling or paneling and glazing in paneled or paneled andglazed shutters for doors, windows and clerestory windows (Area of opening forpanel inserts excluding portion inside grooves or rebates to be measured) paneling forpaneled or paneled and glazed shutters 25 mm to 40 mm thick using good qualityAnjili/ Jack wood
26350.9.5.1 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood/ jack wood 35 mm thick shutters.
2649.141Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5mm (±0.2mm), made out of single piece extruded PVC profile, with mitred cut jointsand with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross sectionsize 35 x 15 mm & self driven self taping screws, the vertical door profiles to bereinforced with 40x20 mm M.S. rectangular tube of 0.8 mm, including providingEPDM rubber gasket weather seal throughout the frame, including jointing 5 mmPVC frame strip with PVC solvent cement on the back of the profile. The door frameto be fixed to the wall using 8x100 mm long anchor fasteners complete, all as permanufacturer's specification and direction of Engineer-in--charge.
2659.142.135 mm thick factory made Solid panel PVC Door shutter, made out of singleNondecorative finish (matt finish)
26610.16.2Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished seamless type tubes
26713.48.3Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Painting Steel work with Deluxe MultiSurface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqmover an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand andmanufacture
26813.52.1Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturer's specifications including appropriate priming coat, preparationof surface, etc. complete.On steel work
2692.25Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
270PLUMBING
27117.2.1Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked white solid plastic seat andlid
27217.32.1Providing and fixing mirror of superior glass ( of approved quality) and of requiredshape and size with plastic moulded frame of approved make and shade with 6 mmthick hard board backing :Circular shape 450 mm dia
27350.17.1.5Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge
27417.7.8Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Surgeontype wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps withelbow including operated levers
27517.70.1Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31 mmsingle piece moulded with height of 270 mm, effective length of tail pipe 260 mmfrom the center of the waste coupling, 77 mm breadth with 25 mm minimum waterseal, weighing not less than 260 gms
27617.73.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleatswith CP brass screws with concealed fitting arrangement of approved quality andcolour450 mm long towel rail with total length of 495 mm, 78 mm wide and effectiveheight of 88 mm. weighing not less than 170 gms
27718.32.1Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm(inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation,foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mmnominal size) and inside plastering with cement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cementcomplete as per standard design:With common burnt clay F.P.S (non modular) bricksof class designation 7.5
27819.7.1.1Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand)with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick withcement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neatcement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size ) finished with a floating coat of neatcement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty)455x610 mm internal dimensions, total weight of cover and frame to be not less than38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clayF.P.S. (non modular) bricks of class designation 7.5
27918.17.2 Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) :32 mm nominal bore
28018.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank.
28118.51.1Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore
28218.53.1Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore
28318.56.1Providing and fixing PTMT pillar cock of approved quality and colour.15 mmnominal bore, 107 mm long, weighing not less than 110 gms
28450.18.7.2.1Providing and fixing PVC pipes, fittings including fixing the pipe with claps at 1.00metre spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 20 mmdia 12Kgf/cm2 - Internal work - Exposed on wall
28550.18.7.3.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer- in- Charge 25 mmdia 12 Kgf/cm2 - Internal work - Exposed on wall
28650.18.9.18.1Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 mspacing. This included jointing of pipes with one step PVC solvent cement and testingof joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 External work- Exposed on wall
28750.18.9.19.1Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2 - External work- Exposed on wall
28850.18.9.9.1Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per direction ofengineer in charge.110 mm dia 6Kgf/cm2
28918.8.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.20 mm nominal dia pipes
29018.8.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.25 mm nominal dia pipes
291ELECTRICAL WORKS
2921.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
2931.12Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductorsingle core cable in surface/ recessed medium class PVC conduit along with 1 No 4sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing asrequired.
2941.14.10Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire
2951.14.2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2961.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.5/6amps switch
2971.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch
2981.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.3pin 5/6 amp socket outlet
2991.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.6pin 15/16 amp socket outlet
3001.25Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. asrequired
3011.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
3021.27.4Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
3031.55.3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bellpoint ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. asrequired.Group C
304OD20899/2025-2026Supplying and fixing following way prewired TP&N MCB distribution board of steelsheet for 415 volts on surface/ recess complete with loose wire box, terminalconnectors for all incoming and outgoing circuits, duly prewired with suitable sizeFRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar,neutral link, earth bar, din bar, detachable gland plate,interconnections, powderpainted including earthing etc. as required.(But without MCB/ RCCB/Isolator)6 way (4+18), Double door
3052.3.2Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
3062.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
3072.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps
3082.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps
3092.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
3102.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
311OD20900/2025-2026 Supply and fixing 40A TP MCB in existing DB with all connections as required
3121.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm
3131.21.2Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm
3141.21.3 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm
3151.41Installation, testing and commissioning of pre - wired, fluorescent fitting/ compactfluorescent fitting of all types, complete with all accessories and tube etc. directly onceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copperconductor, single core cable and earthing etc. as required.
3161.44Installation, testing and commissioning of ceiling fan, including wiring the down rodsof standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copperconductor, single core cable etc. as required
3171.47Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavygauge including painting etc. as required. (Note: More than 5 cm length shall berounded to the nearest 10 cm and 5 cm or less shall be ignored)
3181.50.1Installation of exhaust fan in the existing opening, including making good the damageconnection testing, commissioning etc. as required.Upto 450 mm sweep
319OD20901/2025-2026Supplying and fixing angle batten with20 watts led bulb and other accessories
320OD20902/2025-2026Supply of 20W led bulkhead light fittings with all the accessories, etc., as required
321OD20903/2025-2026Supplying, Installing, testing and commissioning of wall mounted Three Phase 4 wireenergy meter with a polycarbonate body having range of 10-63 A, with enclosuremade out of powder coated 16 SWG CRCA sheet suitable for fixing in surface/recesswith 3 nos. of 63A HRC fuses, 63A TPN isolator, neutral link, its interconnections,etc.The enclosure shall have lockable door with glass window and all mountingaccessories complete as required (supplying of energy meter is under KSEB scope)
322OD20904/2025-2026Supply of 200 mm sweep,900 rpm light-duty exhaust fan in plastic body with selfopening louvers working on 230 V AC supply complete with all acc accessories asrequired. (Make: Crompton/Havells or equivalent approved make)
323OD20905/2025-2026 Supply of IP66 streetlight luminaire made of die-cast aluminum along with driver,system wattage of 30+/- 2 watts, lumen output of luminaire greater than 3300 lumens,power factor of 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than110 lumens/watt with suitable driver, and including all necessary accessories asrequired, complete. (MakeCat No: Wipro LR02-331-XXX-57-XX, CG: LSTS-30CDL or other approved equivalent makes)
324OD20906/2025-2026 Supply of single tube set LED 20W and other accessories
325OD20907/2025-2026Supply of 1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt), Air delivery minimum 210(cubic meter/minute), 300mm downrod, 2 number canopies, shackele kit, Copper winding, 3 number blades and allremaining accessories including safety pin, nut bolts, washers suitable for 230V/240Vsingle phase AC supply,BLDC etc. complete as required make orient/havells or equivalent
3265.12Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wirein 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimbleexcavation and re-filling as required.
3275.17Providing and fixing 4.00 mm dia copper wire on surface or in recess for loopearthing as required.
3285.2Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc.(but without charcoal/ coke and salt) as required
329CONSTRUCTION OF STAFF BARRACK AT VAZHACHAL FOREST STATION
330CIVIL WORKS
3312.1.1Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m inwidth as well as 10 sqm on plan including disposal of excavated earth up to 50 m andlift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
3324.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources)
33360.2.1EARTH WORK FILLING- Supplying contractors own earth including cost ofconveyance and royalty and filling (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m
3344.1.3Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarsesand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources)
3355.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources)
3365.2.2Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up tot floor five level excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 gradedstone aggregate 20 mm nominal size derived from natural sources)
3375.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more
3385.3Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (ZoneIII) derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources).
3395.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete
3405.9.20Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform with water proof ply 12 mmthick
3415.9.21Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mmthick.
3425.9.7Centering and shuttering including strutting, etc. and removal of form for:Stairs,(excluding landings ) except spiral - staircases)
34310.17Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shapewith hooked ends in R.C.C. slabs or beams during laying, including painting theexposed portion of loop, all as per standard design complete.
3445.9.6 Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts
34550.6.2.2Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm ornearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etccomplete
34613.9.1Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neatcement.12 mm cement plaster
34713.16.16 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
34813.4.112 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
349OD20328/2025-2026Water proof plastering with Cement Mortar 1:4 (1 cement : 4 fine sand) 12mm thickplaster finished with a floating coat of neat cement mixed with water proofingcompound of approved make @ 2kg/m2 of mix floated hard and troweled smoothincluding all labour, material, conveyance charges etc complete.
35013.26Providing and applying plaster of paris putty of 2 mm thickness over plastered surfaceto prepare the surface even and smooth complete.
35113.43.1Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer
35222.3Providing and laying water proofing treatment to vertical and horizontal surfaces ofdepressed portions of W.C. kitchen and the like consisting of : i) I course of applyingcement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming toIS: 2645 in recommended proportions including rounding off junction of vertical andhorizontal surface. ii) II course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarsesand) mixed with water proofing compound in recommended proportion includingrounding off junction of vertical and horizontal surface. iii) III course of applyingblown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IV course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wideand pasted to each other with bitumen @ 1.7 Kg/ sqm.
353OD20329/2025-2026Finishing with Deluxe Multi-Surface Paint System for interiors and exteriors as permanufacturers' specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqmover primer
35411.41.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm.
35511.36Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer -inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm,including pointing in white cement mixed with pigment of matching shade complete.
35611.40Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm ormore (thickness to be specified by the manufacturer) of Ist quality conforming to IS:15622 of approved make in all colours, shades, except white, Ivory, Grey Fume RedBrown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) includingpointing the joints with white cement and matching pigments etc., complete.
35711.48.2Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm
3589.48.2Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
35950.9.1.1Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid forseparately), using good quality Anjili wood /jack wood
36050.9.2.1Providing and fixing paneled and glazed shutters for doors, windows and clerestorywindows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges brightfinished of required size with necessary screws, excluding panelling which will bepaid for separately, all complete as per direction of Engineerin - charge using Anjili/Jack wood
36150.9.4.1Providing and fixing paneling or paneling and glazing in paneled or paneled andglazed shutters for doors, windows and clerestory windows (Area of opening forpanel inserts excluding portion inside grooves or rebates to be measured) paneling forpaneled or paneled and glazed shutters 25 mm to 40 mm thick using good qualityAnjili/ Jack wood
36250.9.5.1Providing and fixing glazed shutters for doors, windows and clerestory windowsusing 4 mm thick float glass panes including ISI marked M.S pressed butt hingesbright finished of required size with necessary screws. Using Anjili wood/ jack wood35 mm thick shutters.
3639.141Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5mm (±0.2mm), made out of single piece extruded PVC profile, with mitred cut jointsand with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross sectionsize 35 x 15 mm & self driven self taping screws, the vertical door profiles to bereinforced with 40x20 mm M.S. rectangular tube of 0.8 mm, including providingEPDM rubber gasket weather seal throughout the frame, including jointing 5 mmPVC frame strip with PVC solvent cement on the back of the profile. The door frameto be fixed to the wall using 8x100 mm long anchor fasteners complete, all as permanufacturer's specification and direction of Engineer-in--charge.
3649.142.135 mm thick factory made Solid panel PVC Door shutter, made out of singleNondecorative finish (matt finish)
36513.48.3Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Painting Steel work with Deluxe MultiSurface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqmover an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
36613.52.1Finishing with Epoxy paint (two or more coats) at all locations prepared and appliedas per manufacturer's specifications including appropriate priming coat, preparationof surface, etc. complete.On steel work
3672.25Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
36810.16.2Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished seamless type tubes
369PLUMBING WORK
37017.2.1Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked white solid plastic seat andlid
37117.32.1Providing and fixing mirror of superior glass ( of approved quality) and of requiredshape and size with plastic moulded frame of approved make and shade with 6 mmthick hard board backing :Circular shape 450 mm dia
37217.7.8Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Surgeontype wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps withelbow including operated levers
37317.70.1Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mmfrom the center of the waste coupling, 77 mm breadth with 25 mm minimum waterseal, weighing not less than 260 gms
37417.73.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleatswith CP brass screws with concealed fitting arrangement of approved quality andcolour450 mm long towel rail with total length of 495 mm, 78 mm wide and effectiveheight of 88 mm. weighing not less than 170 gms
37550.17.1.5Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge.
37618.32.1Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm(inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation,foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mmnominal size) and inside plastering with cement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cementcomplete as per standard design:With common burnt clay F.P.S (non modular) bricksof class designation 7.5
37719.7.1.1Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand)with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick withcement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neatcement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size ) finished with a floating coat of neatcement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty)455x610 mm internal dimensions, total weight of cover and frame to be not less than38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clayF.P.S. (non modular) bricks of class designation 7.5
37818.17.2Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) :32 mm nominal bore
37918.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank.
38018.51.1Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore
38118.53.1Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore
38218.56.1Providing and fixing PTMT pillar cock of approved quality and colour.15 mmnominal bore, 107 mm long, weighing not less than 110 gms
38350.18.7.2.1Providing and fixing PVC pipes, fittings including fixing the pipe with claps at 1.00metre spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 20 mmdia 12Kgf/cm2 - Internal work - Exposed on wall
38450.18.7.3.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer- in- Charge 25 mmdia 12 Kgf/cm2 - Internal work - Exposed on wall
38550.18.9.18.1Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 mspacing. This included jointing of pipes with one step PVC solvent cement and testingof joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 External work- Exposed on wall
38650.18.9.19.1Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2 - External work- Exposed on wall
38750.18.9.9.1 Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per direction ofengineer in charge.110 mm dia 6Kgf/cm2
38818.8.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.20 mm nominal dia pipes
38918.8.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.25 mm nominal dia pipes
390ELECTRICAL WORKS
3911.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
3921.12Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductorsingle core cable in surface/ recessed medium class PVC conduit along with 1 No 4sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing asrequired.
3931.14.10Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire
3941.14.2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3951.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.5/6amps switch
3961.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch
3971.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.3pin 5/6 amp socket outlet
3981.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.6pin 15/16 amp socket outlet
3991.25Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. asrequired
4001.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
4011.27.4Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
4021.55.3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bellpoint ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. asrequired.Group C
4032.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
4042.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps
4052.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
4062.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
4072.3.2Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
4081.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm
4091.21.2Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm
4101.21.3Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.32 mm
4115.17Providing and fixing 4.00 mm dia copper wire on surface or in recess for loopearthing as required.
4121.41Installation, testing and commissioning of pre - wired, fluorescent fitting/ compactfluorescent fitting of all types, complete with all accessories and tube etc. directly onceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copperconductor, single core cable and earthing etc. as required.
4131.44Installation, testing and commissioning of ceiling fan, including wiring the down rodsof standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copperconductor, single core cable etc. as required.
4141.47Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavygauge including painting etc. as required. (Note: More than 5 cm length shall berounded to the nearest 10 cm and 5 cm or less shall be ignored)
4151.50.1Installation of exhaust fan in the existing opening, including making good the damageconnection testing, commissioning etc. as required.Upto 450 mm sweep
416OD20330/2025-2026Supply, conveyance, installation, testing, and commissioning of 200 mm sweep, 900rpm light duty exhaust fan in a plastic body with self-opening louvers working on a230 V AC supply complete with all accessories as required. (Make:Crompton/Havells or equivalent approved make)
4175.12Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wirein 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimbleexcavation and re-filling as required.
4185.2Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc.(but without charcoal/ coke and salt) as required
419OD20338/2025-2026Supplying and fixing the following way prewired vertical type TP&N MCBdistribution board of steel sheet for 415 volts on surface/recess complete with loosewire box of sheet steel, dust protected, duly powder painted, inclusive of 200 ampstinned copper bus bar, common neutral link, earth bar, DIN bar for mounting MCBs,terminal connectors for all incoming and outgoing circuits, duly prewired withadequate size of FRLS PVC insulated copper conductor up upto the terminalconnector/neutral link, earthing, etc., as required (But without MCB/RCCB/isolator).(Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets arerequired.)8 way Double door
420OD20335/2025-2026 Supply and fixing 40A FP MCB in existing DB with all connections as required
421OD20339/2025-2026Supplying, Installing, testing and commissioning of wall mounted Three Phase 4 wireenergy meter with a polycarbonate body having range of 10-63 A, with enclosuremade out of powder coated 16 SWG CRCA sheet suitable for fixing in surface/recesswith 3 nos. of 63A HRC fuses, 63A TPN isolator, neutral link, its interconnections,etc.The enclosure shall have lockable door with glass window and all mountingaccessories complete as required (supplying of energy meter is under KSEB scope)
422OD20331/2025-2026Supply of 200 mm sweep,900 rpm light-duty exhaust fan in plastic body with selfopening louvers working on 230 V AC supply complete with all accessories asrequired. (Make: Crompton/Havells or equivalent approved make)
423OD20332/2025-2026 Supply of IP66 streetlight luminaire made of die-cast aluminum along with driver,system wattage of 30+/- 2 watts, lumen output of luminaire greater than 3300 lumens,power factor of 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than110 lumens/watt with suitable driver, and including all necessary accessories asrequired, complete. (MakeCat No: Wipro LR02-331-XXX-57-XX, CG: LSTS-30CDL or other approved equivalent makes)
424OD20333/2025-2026Supply of single tube set LED 20W and other accessories
425OD20337/2025-2026Supply of 20W led bulkhead light fittings with all the accessories, etc., as required
426OD20334/2025-2026Supply of 1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt), Air delivery minimum 210(cubic meter/minute), 300mm downrod, 2 number canopies, shackele kit, Copper winding, 3 number blades and allremaining accessories including safety pin, nut bolts, washers suitable for 230V/240Vsingle phase AC supply,BLDC etc. complete as required make orient/havells orequivalent
427OD20336/2025-2026Supplying and fixing angle batten with20 watts led bulb and other accessories
428EXCLUSIVE OF GST
429Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
4302:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items
4313.Rate should be Exclusive of GST.
4324.Work should be executed as per DSR/PWD specification and direction of Engineer at site.
4335.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
4346.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of
435Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
4367.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference
4378.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.)
4389. SOLID BLOCK MASONRY: Min. average compressive strength as per IS shall be 40-50kg/cm2 and has to be assessed by testing at Govt. lab. ( Variation in rate due to change in size of block and level of floor as per DSR/PRICE has to be considered)
43910.PLUMBING & SANITARY FITTINGS: Note: Make of Water supply and sanitary items: Best branded ISI make Jaquar, Cera, Hindware, Parryware or eq. in the order of pref. Water pipe:
440Supreme, Finolex or eq. with IS and all fittings with IS.
44111.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
442Make of Electrical equipments/materials
443All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
444Panel Boards: CPRI certified reputed manufacturers make
445MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
446Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
447Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
448Cable Glands & Sockets - REPUTED MAKE , Cosmos
449Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent
450Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
45112. STEEL WORK G.I.PIPE: Make: JINDAL, Tata or eq. primary make in the order of preference.
45213.DELUXE MULTI SURFACE PAINT SYSTEM: Make: JOTUN, Asian, Berger, Nerolas or eq. in the order of pref.
45314.VITRIFIED FLOOR TILES/ CERAMIC GLAZED WALL TILES: Make: Khajaria, Jhonson, RAK,
454NITCO, Cera or Eq. in the order of preference and prior sample approval from KEL, Client
45515.ALUMINIUM WORK: Make: INDAL, JINDAL in the order of preference and prior sample approval from KEL, Client
45616.Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco,
45718. ACRYLIC SMOOTH EXTERIOR PAINT/ SYNTHETIC ENAMEL PAINT/WHITE CEMENT BASED
458PUTTY/ CEMENT PRIMER: Make: Asian, Berger, Nerolas or eq. in the order of pref. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58284857
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 06-11-2026
Authority
Authority Name Kerala Electrical And Allied Engineering Co Limited
Work Description Tender for Nabard-Ridf Tranche Xxxi (2025-26)- Development Of Rapid Response Units, Forest Station Complex And Other Infrastructure Under Central Circle
Basic Detail
Tender No KRO/ BDC/2470/2026
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 30 Oct 2026
Submission Date 06 Nov 2026
Open Date 07 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee 8850
EMD 1 Lakhs
Exemption Available
Document List
BOQ_1505488.xls
d05bc2fb-bf70-4adb-97e0-46890bcdc088.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1505488.xls

html

d05bc2fb-bf70-4adb-97e0-46890bcdc088.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender