Tender For Rehabilitation Of Drainage And Inspection Chambers To The Existing 9 Nos. Of Si & 57 Nos. Of Pc/Hc Quarters (D Block) And 56 Nos. Of Pc/Hc Quarters (E Block) At annual repair C Us In Vellore District.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Nov 2026
0 days left
EMD
28600
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Vellore → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Rehabilitation Of Drainage And Inspection Chambers To The Existing 9 Nos. Of Si & 57 Nos. Of Pc/Hc Quarters (D Block) And 56 Nos. Of Pc/Hc Quarters (E Block) At annual repair C Us In Vellore District.
BOQ
| Sl. No. | Item Description |
| 1 | DW-B/S-CMW-U3) Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of Brick / Stone Masonry in cement mortar walls under 3m high including all tools and plants required etc. all complete as per relevant standard specifications and as directed by the departmental officers. |
| 2 | DM-R-PT-OC) Removing of One Course of Pressed Tile Roof finish in cement mortar including all tools and plants required etc. all complete as per relevant standard specifications and as directed by the departmental officers. |
| 3 | Clean Removel of Cement Plaster from walls without affecting the adjacent structure including the cost of required tools and plants and scaffolding, if necessary and clearing the debris away from the site etc., all complete and as directed by the departmental officers. |
| 4 | DW-CS-C-HJ) Clearing Heavy Jungle Clearing heavy jungles in the work site including labour charges for cutting and cleaning the site with required tools & plants and dumping the waste material to out of site boundary etc. all complete and as directed by the departmental officers. |
| 5 | EW-AS-NC-IR) Earth work excavation for foundation in all soils and sub-soils to the required depth as may be directed except in hard rock requiring blasting but inclusive of shoring, strutting, and bailing out water wherever necessary and refilling the sides of foundation with excavated earth in 150mm thick layers (Including Refilling)EW-AS-NC-IR-2m)a) 0 to 2m depth. |
| 6 | EW-AS-Dr-ER) Earth work excavation for Open Foundation for drains in all soils and subsoils to the required depth as may be directed except in hard rock requiring blasting, inclusive of shoring, strutting and bailing out water wherever necessary. (Excluding refilling the sides of foundation) and depositing the earth in places shown clearing and leveling the site with an initial lead of 10 metres and lift as specified hereunder etc., complete in all respects complying with relevant standard specification (Excluding Refilling) (Drain having bed width upto 1.25 metre).EW-AS-Dr-ER-2m)a) 0 to 2m depth. |
| 7 | EW-AS-OC-IR) Earth work excavation for Open Foundation in all soils and sub soils to the required depth as may be directed except in hard rock requiring blasting but inclusive of shoring, strutting and bailing out water wherever necessary and refilling the sides of foundation with excavated earth in 150 mm thick layers well watered rammed and consolidated and depositing the surplus earth in places shown clearing and levelling the site with an initial lead of 10 metres and lift as specified hereunder etc., complete in all respects complying with relevant StandardSpecifications (Including Refilling)EW-AS-OC-IR-2m)a) 0 to 2m depth. |
| 8 | FL-FB-SCS) supplying and filling in foundation and basement with filling crushed stone sand in layers of 150 mm thickness well watered, rammed and consolidated complying with relevant standard specification including cost of supplying filling crushed stone sand. |
| 9 | FL-FB-HBSJ-40mm) Supplying and filling with 40mm size Hard broken stone jelly in foundation and basement and other similar works including cost of materials, labour charges, etc., all complete and as directedby the departmental officers. |
| 10 | FL-FB-HBSJ-20mm) Supplying and filling with 20mm size Hard broken stone jelly in foundation and basement and other similar works including cost of materials, Labour charges etc., all complete and as directed by the departmental officers. |
| 11 | CN-FB-PCC-1:5:10) Plain cement concrete 1:5:10 (One of cement, five of crushed stone sand and ten of hard broken stone Jelly including Mortar Plasticizer (Liquid) at 200ml per bag) for foundation and basement using 40 mm gauge hard broken stone jelly |
| 12 | BW-FB-KB-CM 1:5) Brick work in Cement Mortar 1:5 (One of cement and five of crushed stone sand including Mortar Plasticizer (Liquid) at 200ml per bag) using Kiln burnt country bricks of size 8¾”x4¼”x2¾” (22x11x7cm) in foundation and basement including dewatering wherever necessary proper setting, curing etc., complete with relevant standard specifications. |
| 13 | BW-PW 110mm-KB-CM 1:4) Brick partition wall in Cement Mortar 1:4 (One of cement and four of crushed stone sand including Mortar Plasticizer (Liquid) at 200ml per bag) 110mm thick for super structure in the following floors using Kiln burnt country bricks of size 8¾”x4¼x2¾” (22x11x7cm) including labour for fixing the doors, windows and ventilator frames in position, fixing of hold fasts, scaffoldings, curing etc., complete in all respect complying with relevant standard specifications and drawings.BW-PW 110mm - FB-KB-CM 1:4) a. In Foundation and basement |
| 14 | PL-FL-CM 1:4-20mm) Plastering the top of flooring in cm 1:4 (one of cement and four of crushed stone sand including Mortar Plasticizer (Liquid) at 200ml per bag) 20mm thick including surface rendered smooth including providing proper slopes, thread lining, curing and 150mm wide skirting alround with the same cement mortar etc., complete in all respects. |
| 15 | PL-OU-CM 1:5-12mm) Plastering with CM 1:5 (One of cement and five of crushed stone sand including Mortar Plasticizer (Liquid) at 200ml per bag) 12mm thick finished with neat cement, including providing band cornice, ceiling cornice, curing, scaffolding, etc., complete in all respects and complying with relevant standard specifications. |
| 16 | PL-IN-CM 1:4-12mm) Plastering with CM 1:4 (one of cement and four of crushed stone sand including Mortar Plasticizer (Liquid) at 200ml per bag) 12mm thick finished with neat cement including providing band cornice, ceiling cornice, curing, scaffolding etc., complete in all respects and complying with standard specifications. |
| 17 | SA-Ex-SFRC-S) Supply and delivery at site and fixing of SFRC manhole cover with frame with locking arrangement of clear opening heavy duty with 10 Ton capacity including of all cost etc., all completed and as directed by the departmental officers.SA-Ex-SFRC-600 x 600) b. 600mm x 600 mm |
| 18 | WS-EX-ASTM-PVC) Supplying, laying, fixing and jointing the following PVC pipes as per ASTM D - 1785 of suitable schedule (40/60/80) of wall thickness not less than the specified in IS 4985 suitable for plumbing by threading of wall thickness including the cost of suitable PVC/UPVC/GI specials /GM specials like Elbow, Tee reducers, Plug, union, bend, coupler, nipple/ GM gate valve, check and wheel valve etc., wherever required above the ground level including the cost of teflon tape, special clamps, nails, etc., fixing on wall to the proper gradient and alignment and redoing the chipped of masonry etc., as directed by the departmental officers.WS-EX-ASTM-32 PVC)a) 32mm dia |
| 19 | WS-EX-ASTM-25 PVC)b) 25mm dia |
| 20 | SA-IN-GT-KB) Supplying and fixing 150mm x 100mm size stone ware Gully trap with iron gratings over a bed of 150mm thick brick jelly concrete in CC 1:8:16 (one of cement, eight of crushed stone sand and sixteen of broken brick jelly) using 40mm size brick jelly and brick masonry wall 110 mm thick using kiln burnt country bricks of size 8¾”x4¼”x2¾” (22x11x7cm) in cm 1:5 (One of cement and five of crushed stone sand) plastered with CM 1:3 (One of cement and three of crushed stone sand) 12mm thick including Mortar Plasticizer (Liquid) at 200ml per bag etc., complete and as directed by the departmental officers. |
| 21 | SA-Ex-SWR P-Dia) Supplying and fixing the following dia PVC (SWR) pipe with ISI mark confirming to IS 13952:1992- type `B` for soil line with relevant specials confirming to IS 14735 including jointing with seal ring confirming to IS 5382 with leaving a gap about 10mm to allow thermal expansion, fixing the pipes into walls with necessary UPVC special clamps, wooden plug, screws, holding wherever necessary and making good of the dismantled portion with necessary connections to sanitary fittings etc., complete in all respects and as directed by the departmental officers.SA-Ex-SWR P-110)a) 110mm dia PVC SWR pipe including all required PVC specials etc., all complete., |
| 22 | SA-Ex-SWR P-75)b) 75mm dia PVC SWR pipe including all required PVC specials etc., all complete., |
| 23 | SA-Ex-SN8-Dia) Supplying, laying and jointing the following dia UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003, superior variety and tested with water, including necessary earth work excavation for trenches and refilling the same, well rammed and consolidated after the pipes are jointed and laid to proper gradiant to the alignment as directed by the departmental officers. (SN8 SDR 34 (S16.5), as per IS 15328/2003, should be got approved by the EE/SE/CE before use in works)SA-Ex-SN8-110)a. 110 mm UPVC Non Pressure pipe |
| 24 | SA-Ex-SN8-160)b. 160 mm UPVC Non Pressure pipe |
| 25 | SA-Ex-SWR P-LJ) Supplying and laying and loose jointing the following dia stone ware pipes with ISI mark Superior variety (glazed) with spigot and sockets ends in dry conditions and tested with water, after the pipes are laid to proper gradient to the alignment etc., complete and as directed by the departmental officers.SA-Ex-SWR P-150)b. 150 mm dia S.W. pipe |
| 26 | Desilting the existing septic tank by using 5000 litres capacity vehicle and using compressor septic tank pump including cost of loading, hire charges, conveyance the septic tank sludge away from the town, unloading and cleaning the septic tank with water after disposal etc., all complete and as directed by the departmental officers. |
| 27 | CN-FPS-1:3:6-50mm) Supplying and fixing of fibre mixed precast slab of 50mm thick of all required shapes made in cement concrete 1:3:6 (one of cement,three of crushed stone sand and six of 20mm hard broken stone jelly including Mortar Plasticizer (Liquid) at 200ml per bag) with secondary reinforcement fibre of approved quality at 0.25% by weight of cement (125gm of fibre for 1 bag i.e., 50Kg of cement) used including cost of all materials, moulding, curing, transportation, laying, pointing etc., for approach road,pavement slab and other similar works etc., complete as per the relevant standard specifications and as directed by the departmental officers. (The shape of slab and brand and quality of fibre should be got approved from the Executive Engineer before use) |
| 28 | Providing and filling the tile joint with epoxy grout with following specification: Surface preparation including cleaning the joint to be free from dust and loose particles. Providing masking tape on either side of the tile joint edges and providing sealing the tile gap with epoxy tile joint grout and finishing neatly and as directed by the departmental officers. The rate inclusive of cost of materials and labour, etc., complete. |
| 29 | Acid washing the existing floor tiles and wall tiles to make it dirt free including cost of materials and labour etc., complete and as directed by the departmental officers. |
| 30 | FL-FB-GR) supplying and filling in foundation and basement with gravel in layers of 150 mm thickness well watered, rammed and consolidated complying with relevant standard specifications including cost of supplying gravel and as directed by the departmental officers. |
| 31 | SA-IN-VSC-PVC) Supplying and fixing the following dia PVC(SWR) pipe with ISI mark confirming to IS 13952:1992- type `A` with PVC cowl and relevant specials confirming to IS 14735 including jointing with seal ring confirming to IS 5382 with leaving a gap 10mm to allow thermal expansion and fixing the pipes into walls or over the septic tank with necessary wooden plug, screws, holding wherever necessary and making good of the dismantled portion with necessary connections to sanitary fittings etc., complete in all respects and as directed by the departmental officers. a) 110mm dia PVC SWR pipe of 3metre with required PVC cowl & PVC specials etc., all complete. |
| 32 | Cleaning the existing drain including labour charges and conveyance the drain waste away from site etc., all complete and as directed by the departmental officers. |
| 33 | Cleaning the existing Inspection Chambers including labour charges and conveyance the drain waste away from site etc., all complete and as directed by the departmental officers. |
| 34 | Labour charges for chipping and removing peeled concrete cover for an average thickness of 30-50 mm until the reinforcement is exposed or a sound structure is found complete., including hire charges for Casurino props and cost of cocunut coir rope for tying the post etc., all complete. |
| 35 | Providing Nitozine primer coat with two component epoxy zinc rich primer over the prepared reinforcement bars after mixing the base and hardner mechanically using heavy duty slow speed stirrer and applying the same using a stiff bristle brush to ensure an unbroken coating. |
| 36 | Providing Nitobond EP epoxy bonding agent after washing the prepared surface with clean potable water, allowed drying, mixing base and hardener of Nitobond EP, applying over the surface using Nylon brush. |
| 37 | Special plastering over the existing old brick wall with C.M. 1:5, 12 to 40mm thick mixed with SBR (Polymer bonding agent) including admixture, providing band cornice, ceiling cornice, curing, scaffolding etc., all complete complying with relevent standard specifications. |
| 38 | Painting the new plaster walls with One coat of approved best Exterior Emulsion paint of best approved quality color and shade in addition to one coat of approved primer paint over cement plastered wall surfaces including cost of Exterior Emulsion paint, putty, brushes, etc., all complete as directed by the departmental officers (Paints and its shade should be got approved from the Executive Engineer before using) |
| 39 | Removing and Relaying the existing Precast slab of 50mm thick of all required shapes including cost of all materials, labour charges for laying and pointing etc., complete and as directed by the departmental officers. |
| 40 | TL-RO-PT-CM 1:3) Finishing top of roof with one course of Pressed Tiles of approved superior quality of size 23cmx 23cmx20mm thick laid over weathering course in CM 1:3 (One of cement and three of crushed stone sand including Mortar Plasticizer (Liquid) at 200ml per bag,) 12mm thick mixed with Water proofing compound at 2% by weight of cement used and pointed neatly with the same cement mortar mixed with water proofing compound including curing etc., as per standard specifications. (The quality of tiles shall be got approved from the Executive Engineer before use) |
| 41 | Supplying and fixing of PVC tank lid including cost of material and labour charges for fixing etc., all complete and as directed by the departmental officers. |
| 42 | Removing the existing PVC tank and refixing after cleaning including cost of materials and labour charges for fixing etc, all complete and as directed by the departmental officers. |
| 43 | WS-EX-RWD-PVC) Supplying and fixing of following dia PVC SWR pipe with ISI mark conforming to IS 13952:1992- type `A` for Rain water down fall pipe with relevant specials such as gratings, shoes, bends, offsets conforming to IS 14735 including jointing with seal ring conforming IS 5382 with leaving a gap about 10mm to allow thermal expansion with necessary clamps, teak wood plugs, etc., of approved quality and including fixing C.I. gratings at the junction of parapet and floor or roof slab etc., including finishing etc., complete complying with relevant standard specifications. (The quality and brand of fittings should be got approved from Executive Engineer before use).WS-EX-RWD-PVC 110) b. 110mm dia PVC SWR pipe |
| 44 | WS-IN/EX-Spl PVC / UPVC / CPVC / GI / CI / GM / MS / SS-Dia) Supply and fixing of following dia PVC / UPVC / CPVC / GI / CI / GM / MS / SS Specials of best approved quality,with ISI mark including cost and conveyence and fixing in position etc., all complete in all respects complying with relevant standard specification and as directed by the departmental officer (The brand and quality of the Specials should be got approved from EE before use)WS-IN/EX-GM GV-GV)21.Gun Metal Gate Valve.WS-IN/EX-GM GV-25) c. 25 mm Dia |
| 45 | WS-IN/EX-GM GV-32) d. 32 mm Dia |
| 46 | FW-SS-AHS-2leg) Providing two legged scaffolding using 15cm diameter casurina props or best quality bamboo posts of 4m overall length (3m height + 0.50m projection + 0.50m into the ground ) the distance between the two rows being 1.25 m and the spacing of posts being 2m in both rows with two horizontal posts with 0.5m overlap on either side and braces at 2mc/c including longitudinal and transverse middle braces to step up and providing a platform with country wood planks of 40mm thick and 1 m width etc., all complete firm using coir and nails 1m run.FW-SS-AHS-10.5m)d).10.50 m height in addition of 2.5m ht |
| 47 | CN-F&S-PCS-M20-20/40) Providing precast concrete slab for cupboard ward robes shelves, cover slab for chambers, Baffle walls side slabs of boxing around windows and other similar works in Standardised concrete mix M20 for the following thickness excluding the cost and fabrication of reinforcement grills but including precasting, moulding, curing, finishing and fixing in position complying with relevant standard specifications etc., complete in the following floors (Measurement will be taken including bearing in wall also)CN-F&S-PCS-M20-40) II. 40mm thickCN-FB-PCS-M20-40)a. In Foundation & basement |
| 48 | RE-RTS-Fe-NC) Supplying, fabricating and placing in position of Mild steel Grills / Ribbed Tor Steels (without cement slurry) of all diameters for reinforcement for all floors including cost of binding wire, bending tying etc., all complete and as directed by the departmental officers. |
| 49 | CN-SS-JV-M20-50) Precast cement concrete Jally ventilator using standardised concrete mix M20 (without vibrating charges) using 20mm gauge hard broken stone jelly for the following thickness excluding the cost and fabrication of reinforcement grills but including precasting, moulding, curing, finishing and fixing in position complying with relevant standard specifications etc., complete in the following floors. 50mm thick.CN-SS-JV-M20-50-(GF)) a. In Ground Floor |
| 50 | CN-SS-JV-M20-50-(1F)) b. In First Floor |
| 51 | CN-SS-JV-M20-50-(2F)) c. In Second Floor |
| 52 | CN-SS-JV-M20-50-(3F)) d. In Third Floor Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedNov 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer