Tender For Engagement Of Service Provider For Various Documentation Along With Supply, Installation Of The Pre-Requisites Needed For Successful Application & Recognition From Nabl For 11 Mandatory Water Quality Parameters For Jamada Wtp Sub-District
Tender Overview
Project Description
Tender for Engagement Of Service Provider For Various Documentation Along With Supply, Installation Of The Pre-Requisites Needed For Successful Application & Recognition From Nabl For 11 Mandatory Water Quality Parameters For Jamada Wtp Sub-District Water Testing Laboratory Under Project Management Unit (Purulia) Under Phe Department, Govt. Of West Bengal. , Rendering Training And Awareness Generation Of Iso/Iec: 17025: 2017 Protocol Deputing Resources Person For Supervision And Hands On Training On Analysis Of 11 Mandatory Parameter For Nabl Recognition Through Nabl Glap Providing Service By Assigning Technical Resource Team For Supervision Of Nabl Recognition (Chemical Testing Of Potable Water) Of Block Level Water Testing Laboratory Under Phe Dte, As Per Below Scope Details: Training To The Lab Personnel On Overview Of Nabl Accreditation As Per Iso/Iec 17025:2017 And Recognition Guidelines For Laboratory Setup (Standard Instrument, Enhancing Manpower Competency, Standard Reference Materials, Mode Of Calibration Of Different Instruments) And As Per Requirement Of Nabl Recognition. To Conduct Consolidated Refresher Hands-On Training On Chemical Parameters Testing And Standardization Procedure Related To Mandatory 11 Parameters As Per Requirement Of Nabl Recognition. To Supervise And Assist For Preparation & Record Of General Documentation To Set Up A Brief Laboratory Operation System Management To Achieve The Requirement Of Nabl Recognition Including Reviewing And Up-Dating Of Documents Of Test Procedure & Records Reviewing And Up-Dating Of Test Procedure & Risk Analysis To Supervise And Assist For Preparation & Record Of Technical Documentation As Per Requirement Of Nabl Recognition Protocol To Supervise And Assist For Preparation & Record Of Proficiency Testing & The Related Technical Documentation For Nabl Recognition, Nc Closing. , Annual Recognition Fees For 3 Years And Pt Test Charge (One Time) & Logistic Expenses , Calibration Of Required Measuring Equipment And Certificate From Nabl Accredited Calibration Laboratory For Nabl Recognition Viz. Analytical Balance, F1 Class Weight Box, , Required Quantity Burettes, Pipettes Of Different Volume, Volumetric Flask Of Different Volume, Thermometer, All Digital Indicator With Rtd, Hao, Hygrometer For Nabl Glap Web Based Application As Per Iso/Iec 17025:2017 , Supply Of F1 Class Analytical Certified (As Per Iso-17025 Requirement) Standard Weight Box With Fractional Weight Tx-F1-1500-Shi-Am , Htc Instrument - Digital Indoor Outdoor Hygro Thermometer With Clock As Per Specification Given In Scope Of Work , High Accuracy Digital Temperature Sensor With Probe- As Per Specification Given In Scope Of Work , Thermometer 10/110 Deg C, Mercury Filled , Thermometer 10/250 Deg C, Mercury Filled , Ph Buffers - 25°C : Clear, Colourless Ph Buffer Solutions. Tested At 25°C And From Iso:17034 Rmp Certificate, Nist Traceable, Ph: 4.00 ±0.01@25°C In 500 Ml , Ph Buffers - 25°C : Clear, Colourless Ph Buffer Solutions.Tested At 25°C And From Iso:17034 Rmp Certificate, Nist Traceable, Ph: 7.00 ±0.01@25°C In 500 Ml , Ph Buffers - 25°C : Clear, Colourless Ph Buffer Solutions. Tested At 25°C And From Iso:17034 Rmp Certificate, Nist Traceable, Ph: 10.00 ±0.01@25°C In 500 Ml , Sodium Carbonate Volumetric Standard, Secondary Reference Material For Acidimetry, Traceable Srm, From Iso:17034 Rmp , Calcium Carbonate Volumetric Standard. Secondary Reference Matenal For Complexometry, Traceable To Nist Standard Reference Material (Srm) From Iso:17034 Rmp , Sodium Chloride Volumetric Standard, Srm For Argentometry, Traceable Srm From Iso:17034 Rmp. , Turbidity Standard Non Ratio, 1000 Ntu, Certified. Nist Traceable, 500 Ml From Iso:17034 Rmp. , Conductivity 1.41 Crm/Kcl, Nist Traceable, 5 Gm From Iso:17034 Rmp. , Certified Traceable To Si Unit Of Pt-Co Color Units Calibration Standard Crm From Iso:17034 Rmp. , Methyl Red Indicator 125 Ml , Bromocresol Green Indicator , Potassium Chloride, 500 Gm , Water For Chromatography, 1 Lit Pk , Nessler Cylinder, For Colour Comparison Graduated As Per Is 4161 : 1967. , Wide Mouth Borosilicate Glass Bottle 1000 Ml With Glass Stopper , Desiccator 8 With Chart Plate , Silica Gel Self Indicating, 500 Gm , Stand For 50 Ml Nessler Cylinder , Supply Of Wall Mount Safety Eye/Face Wash As Per Is 10592:1982 , I. Cones 1000Ml Graduated With Bottom Outlet Stand For Cones, Imhoff , Safety Googles, Pk Of 2 Nos , Nitrile Gloves(Hand Gloves)/Pk Of 100 Nos , Hardened Ashless Filter Paper For Total Dissolved Solid/Pk Of 100 Circles
BOQ
| Sl. No. | Item Description |
| 1 | Rendering Training and awareness generation of ISO/IEC: 17025: 2017 protocol deputing Resources person for supervision and hands on training on analysis of 11 mandatory parameter for NABL recognition through NABL GLAP Providing service by assigning Technical resource team for supervision of NABL recognition (Chemical Testing of potable water) of Block level Water Testing Laboratory under PHE Dte, as per below scope details: Training to the Lab personnel on overview of NABL accreditation as per ISO/IEC 17025:2017 and recognition Guidelines for Laboratory Setup (Standard Instrument, enhancing manpower competency, Standard reference materials, mode of calibration of different instruments) and as per requirement of NABL recognition. To conduct consolidated Refresher hands-on training on chemical parameters testing and standardization procedure related to mandatory 11 parameters as per requirement of NABL recognition. To supervise and assist for preparation & record of General Documentation to set up a brief Laboratory operation system management to achieve the requirement of NABL recognition including Reviewing and Up-dating of Documents of Test Procedure & Records Reviewing and Up-dating of Test Procedure & risk analysis To supervise and assist for preparation & record of Technical Documentation as per requirement of NABL recognition protocol To supervise and assist for preparation & record of Proficiency Testing & the related Technical Documentation for NABL recognition, NC closing. |
| 2 | Annual recognition fees for 3 years and PT test charge (one time) & logistic expenses |
| 3 | Calibration of required measuring equipment and certificate from NABL accredited calibration laboratory for NABL recognition Viz. Analytical Balance, F1 class Weight Box, , required quantity Burettes, Pipettes of different volume, Volumetric Flask of different volume, Thermometer, all digital indicator With RTD, HAO, Hygrometer for NABL GLAP web based application as per ISO/IEC 17025:2017 |
| 4 | Supply of F1 Class Analytical Certified (as per ISO-17025 requirement) standard weight Box with fractional weight TX-F1-1500-SHI-AM |
| 5 | HTC Instrument - Digital Indoor Outdoor Hygro Thermometer with Clock as per specification given in scope of work |
| 6 | High Accuracy Digital Temperature sensor with probe- as per specification given in scope of work |
| 7 | Thermometer 10/110 deg C, mercury filled |
| 8 | Thermometer 10/250 deg C, mercury filled |
| 9 | pH Buffers - 25°C : Clear, Colourless pH Buffer Solutions. Tested at 25°C and from ISO:17034 RMP Certificate, NIST traceable, pH: 4.00 ±0.01@25°C in 500 ml |
| 10 | pH Buffers - 25°C : Clear, Colourless pH Buffer Solutions.Tested at 25°C and from ISO:17034 RMP Certificate, NIST traceable, pH: 7.00 ±0.01@25°C in 500 ml |
| 11 | pH Buffers - 25°C : Clear, Colourless pH Buffer Solutions. Tested at 25°C and from ISO:17034 RMP Certificate, NIST traceable, pH: 10.00 ±0.01@25°C in 500 ml |
| 12 | Sodium carbonate volumetric standard, secondary reference material for acidimetry, traceable SRM, from ISO:17034 RMP |
| 13 | Calcium carbonate volumetric standard. secondary reference matenal for complexometry, traceable to NIST Standard Reference Material (SRM) from ISO:17034 RMP |
| 14 | Sodium chloride volumetric standard, SRM for argentometry, traceable SRM from ISO:17034 RMP. |
| 15 | Turbidity Standard Non Ratio, 1000 NTU, certified. NIST traceable, 500 ml from ISO:17034 RMP. |
| 16 | Conductivity 1.41 CRM/KCL, NIST Traceable, 5 gm from ISO:17034 RMP. |
| 17 | Certified traceable to SI unit of Pt-Co Color Units Calibration Standard CRM from ISO:17034 RMP. |
| 18 | Methyl red indicator 125 ml |
| 19 | Bromocresol Green indicator |
| 20 | Potassium Chloride, 500 gm |
| 21 | Water for Chromatography, 1 lit pk |
| 22 | Nessler Cylinder, for colour comparison graduated as per IS 4161 : 1967. |
| 23 | Wide mouth Borosilicate Glass bottle 1000 ml with glass stopper |
| 24 | Desiccator 8\\" with Chart plate |
| 25 | Silica Gel self indicating, 500 gm |
| 26 | Stand for 50 ml Nessler Cylinder |
| 27 | Supply of wall mount safety eye/face wash as per IS 10592:1982 |
| 28 | I. Cones 1000ml Graduated with bottom outlet Stand for Cones, Imhoff |
| 29 | Safety Googles, pk of 2 nos |
| 30 | Nitrile Gloves(Hand Gloves)/pk of 100 nos |
| 31 | Hardened ashless filter paper for Total dissolved solid/pk of 100 circles Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender