Tender For Expansion Of Education Hub At Tokarkhada. (Primary School)
Tender Value
58.58 Crore
Estimated cost
Bid Submission
25 Nov 2026
12 days left
EMD
68.59 Lakhs
Bank guarantee accepted
Document Fee
15000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dadra and Nagar Haveli → Dadra and Nagar Haveli
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Expansion Of Education Hub At Tokarkhada. (Primary School)
BOQ
| Sl. No. | Item Description |
| 1 | Clearing and grubbing road land including uprooting rank vegetation grass bushes,shrubs,sapling and trees girth up to 300 mm removal of stumps of trees cut earlier and disposal of unserviceable materials (C) By mechanical means in area of light jungle |
| 2 | Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil |
| 3 | Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil |
| 4 | Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil |
| 5 | Dewatering for work as original or extended including furnishing of pumps and other accessories all complete, as directed by the Engineer. |
| 6 | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering. |
| 7 | Disposal of remaining excavated Earth after filling in foundations and plinth as per direction of Engineer in-charge including loading from site and unloading at disposal site for all lead and lift/depth etc. complete and as directed by EIC. |
| 8 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete etc and as directed by EIC. |
| 9 | Filling in foundation and plinth with murrum or selected soil in layers of 20cm. thickness including watering, ramming and consolidating etc.complete and as directed by EIC. |
| 10 | Providing and filling rubbles including hand packing and filling voids with sand as directed including ramming and consolidating etc. complete and as directed by EIC. |
| 11 | Carrying out plinth treatment to post construction / existing structure by spraying chemical solution for termite control treatment including labour and material consistent with I.S.I specification. Using Chlordane and Chiorpurfiles 20 EC. As Per 6131_paret-II Concentration Weight one percent is recommended i.e. one litre 20 EC chemical emulsion with 19 litre give 1 % concentration inclusive of one litre chemical emulsion application at the rate of 5 Litre chemical / Sqm of surface is recommended as per I.S and as directed by EIC. Approved Makes for Anti-Termite Treatment: Pest Control India Ltd, Pest Con India,Pest Control Incorporated, or any other agency to be approved by the Engineer In-charge |
| 12 | Rolling of earthwork in layers with power roller including filling in depression which occur duirng the process. |
| 13 | Providing, laying and compacting Granular Sub-Base (GSB) using graded mechanically crushed stone material, including carriage from approved source to site, spreading in uniform layers over prepared surface with motor grader, watering, rolling and compaction with vibratory power roller at OMC to achieve the required density, complete as per MoRTH Clause 401 and as directed by the Engineer-in-Charge. |
| 14 | Providing and laying cement concrete 1:3:6 (1- Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mm nominal size) and curing complete excluding cost of formwork in and as directed by EIC.(A) Foundation and Plinth |
| 15 | Construction of dry lean cement concrete sub-base over a prepared subgrade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per Table 600-1 (MORT & H- Revision IV), cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length, concrete strength not to be less than 10 mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 ton vibratory roller, finishing and curing, and formwork as specified in Clause 601 of MORT & H(Revision IV). Including the cost of all material labor charges, machinery hire charges, tools and equipment charges, transportation and conveyance, loading and un loading etc complete with all lead and lift as per specification and directed by the Engineer. |
| 16 | Construction of un-reinforced, dowel jointed, plain cement concrete pavement (M30) of 300mm thickness over a prepared sub-base with 43 grade cement, coarse and fine aggregate conforming to IS 383; maximum size of coarse aggregate not exceeding 25mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, formwork, rails, guidewires, finishing to line and grades as per drawings as specified in clause 602 of MORT & H ; including the cost of Dewatering, channel placings as per gradient, and deshuttering of channels and all material labour charges, machinery hire charges, tools and equipmentcharges, transportation and conveyance, loading and unloading etc complete with all lead and lift as per specification and as directed by the Engineer in charge. |
| 17 | Providing and laying in position ready mixed M-300 grade concrete for reinforced cement concrete work, using cement content as per approved design mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead upto 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of RMC from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/reatrd setting of concrete, improve workability without impairing strength and durability as per direction of the EIC without fly ash(min. cement level as per latest IS 456 shall be maintained) (Cement level 475Kg) Foundations, Pedestal, Column, Shear walls,Compound wall, Slabs, Beams, Lintel and Sill, RCC Seat,RCC Pardi |
| 18 | Second Floor |
| 19 | Third Floor |
| 20 | Terrace |
| 21 | Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work , using cement content as per approved Design Mixmanufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer,manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450 kg ) Grade slab, Planter |
| 22 | Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-35 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads, above rate are including the stocking up up to 1.2 M in to Rock with bore hole in rock(Length of pile for payment of excavated earth with all lifts and leads (Length of pile for payment shall be measured up to bottom of pile cap). 350 mm dia piles. |
| 23 | Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns etc. and Mass concrete. Add Extra for Providing formwork with sheathing steel sheets so as to give a fair finish in (A) Foundations, Footings, Bases of Columns etc. and Mass concrete and as directed by EIC. |
| 24 | Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (B) Flat surfaces such as soffits of suspended floors, slabs, landings and the like and as directed by EIC. (1) Floors etc. upto 200mm in thickness. The formwork shall be accurately aligned, rigid, watertight and free from surface defects. It shall produce a smooth, uniform and fair faced RCC surface finish equivalent to that achieved using Mivan/aluminum formwork, without visible undulations, grout leakage, honeycombing, fins, offsets or excessive shuttering joint marks and as directed by EIC. |
| 25 | Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (C) Vertical surfaces such as walls (any thickness) partitions and the like including attached buttresses & string course & the like. Add Extra for Providing formwork with sheathing steel sheets so as to give a fair finish in (C) Vertical surfaces such as walls (any thickness) partitions and the like including attached buttresses & string course & the like. The formwork shall be accurately aligned, rigid, watertight and free from surface defects. It shall produce a smooth, uniform and fair faced RCC surface finish equivalent to that achieved using Mivan/aluminum formwork, without visible undulations, grout leakage, honeycombing, fins, offsets or excessive shuttering joint marks and as directed by EIC. |
| 26 | Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (G) Columns PillarsPosts and struts. (1) Square Rectangular Polygonal in plan. Add Extra for Providing formwork with sheathing steel sheets so as to give a fair finish in (G) Columns PillarsPosts and struts. (1) Square Rectangular Polygonal in plan. The formwork shall be accurately aligned, rigid, watertight and free from surface defects. It shall produce a smooth, uniform and fair faced RCC surface finish equivalent to that achieved using Mivan/aluminum formwork, without visible undulations, grout leakage, honeycombing, fins, offsets or excessive shuttering joint marks and as directed by EIC. |
| 27 | Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (G) Columns PillarsPosts and struts. (2)Circular or curved in Plan. Add Extra for Providing formwork with sheathing steel sheets so as to give a fair finish in (G) Columns PillarsPosts and struts. (2)Circular or curved in Plan. The formwork shall be accurately aligned, rigid, watertight and free from surface defects. It shall produce a smooth, uniform and fair faced RCC surface finish equivalent to that achieved using Mivan/aluminum formwork, without visible undulations, grout leakage, honeycombing, fins, offsets or excessive shuttering joint marksand as directed by EIC. |
| 28 | Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (H) (1) Sides and soffits of Beams, beam haunchings, cantilevers, girders, bressumers and lintels not exceeding 1M in depth. The formwork shall be accurately aligned, rigid, watertight and free from surface defects. It shall produce a smooth, uniform and fair faced RCC surface finish equivalent to that achieved using Mivan/aluminum formwork, without visible undulations, grout leakage, honeycombing, fins, offsets or excessive shuttering joint marks as directed by EIC. |
| 29 | Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (M) Staircase with sloping or stepped soffits including risers and stringers excluding landing. The formwork shall be accurately aligned, rigid, watertight and free from surface defects. It shall produce a smooth, uniform and fair faced RCC surface finish equivalent to that achieved using Mivan/aluminum formwork, without visible undulations, grout leakage, honeycombing, fins, offsets or excessive shuttering joint marks as directed by EIC. |
| 30 | Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (Q) Vertical fins and vertical sun breakers. Add Extra for Providing formwork with sheathing steel sheets so as to give a fair finish in (Q) Vertical fins and vertical sun breakers. The formwork shall be accurately aligned, rigid, watertight and free from surface defects. It shall produce a smooth, uniform and fair faced RCC surface finish equivalent to that achieved using Mivan/aluminum formwork, without visible undulations, grout leakage, honeycombing, fins, offsets or excessive shuttering joint marks as directed by EIC. |
| 31 | Extra for additional height of propping and centering where the height of propping and centering exceeds 4 .O M between supporting floor to ceiling including temporary brick or stone pillars for supporting as required. (i)Height more than 4.0 M.and upto 5.0 M. |
| 32 | Extra for additional height of propping and centering where the height of propping and centering exceeds 4 .O M between supporting floor to ceiling including temporary brick or stone pillars for supporting as required. (ii) Height more than 5.0 M.and upto 6.0 M. |
| 33 | Extra for additional height of propping and centering where the height of propping and centering exceeds 4 .O M between supporting floor to ceiling including temporary brick or stone pillars for supporting as required. (iii) Height more than 6.0 M. and upto 7.0 M |
| 34 | Extra for additional height of propping and centering where the height of propping and centering exceeds 4 .O M between supporting floor to ceiling including temporary brick or stone pillars for supporting as required. (iii) Height more than 7.0 M. and upto 11.0 M |
| 35 | Providing and laying damp proof course 25mm thick cement concrete 1:2:4 (1-cement : 2-coarse sand : 4-stone aggregate 10mm nominal size) and curing complete for plinth protection and as directed by EIC. Approved Makes of Cement: Larsen& Turbo,Gujarat Ambuja,Vikram,Binani. |
| 36 | Providing and laying and fixing 50mm thick expansion joint by hydro cell semi rigid UV resistance with high performance laminated closed cell polythene foam joint filler in sheet foam as directed etc. complete and as directed by EIC. |
| 37 | 52 mm thick cement concrete flooring (trimix) with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding thecost of nosing of steps etc. complete and as directed by EIC.Approved Makes of Cement: Larsen& Turbo,Gujarat Ambuja,Vikram,Binani. |
| 38 | Providing and fixing formwork for exposed concrete surfaces in the desired pattern, grooves, lines, levels, sizes, drip moulds and other architectural features as shown in the drawings, using accurately saw-cut Deodar wood patties, including cutting, fixing, alignment and securing of patties, complete propping and strutting, deshuttering, removal of Deodar patties and neat cleaning of the exposed concrete surface. Including application of solvent-based water repellent coating to the exposed concrete surface, all as directed by the EIC and as per the drawings. |
| 39 | Cleaning and restoration of exposed RCC surfaces having stains, or any other surface deposits by scraping, grinding, buffing and chemical washing, including preparation of the surface and removal of all loose and contaminated material. The surface shall be brought to its natural and uniform appearance by application of a suitable mixture of marble powder, white cement and grey cement, including filling of minor surface imperfections, levelling and finishing. The item shall also include application of approved Dr. Fixit Powercrete and Carbon Pholacide protective coating, complete at all elevations, including all materials, labour, tools, scaffolding and incidental works, as directed by the Engineer-in-Charge. |
| 40 | Providing and laying cement concrete (IPS) flooring 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregates 20mm nominal size) laid in one layer and finished with a floating coat of neat cement and as directed by EIC. (B) 50mm thick and as directed by EIC.Approved Makes of Cement: Larsen& Turbo,Gujarat Ambuja,Vikram,Binani. |
| 41 | Providing TMT Bar FE 500D reinforcement for R.C.C. work including bending, binding, placing in position and placing mechanical rebar couplers of approved standard parallel-threaded or tapered-threaded type, compatible with high-yield strength deformed (HYSD) reinforcement bars of specified diameters as drawings. The couplers shall provide full-strength and reliable continuity between reinforcement bars and shall include complete end preparation, such as bar-end threading, cold forging or upsetting as required, proper alignment, tightening/torquing and testing. All couplers and installation works shall comply with IS 16172, BS 8110, ACI 318, relevant manufacturer specifications and approved structural drawings, complete in all respects. complete upto floor two level |
| 42 | Second Floor |
| 43 | Third Floor |
| 44 | Terrace |
| 45 | Providing and fixing reinforcement bars (rebaring/dowel bars) of required diameter in existing RCC members by drilling holes of required diameter and depth using rotary hammer drill machine, cleaning the holes with compressed air and brush, injecting approved two-component epoxy/chemical anchoring adhesive (Hilti/Fischer/Fosroc), inserting Fe-500D TMT bars with proper embedment depth as per structural drawings, maintaining alignment, curing as recommended, including cutting, bending, scaffolding, all tools and tackles, complete as directed by Engineer-in-Charge. |
| 46 | Masonary work using Aerated light weight concreteblock having crushing strength not less than 35 kg/sqcmfor super structure above plinth level upto floor two levelin cement mortar 1:5 ( 1 cement : 5 fine sand ) completeas per Technical Specification |
| 47 | Second Floor |
| 48 | Third Floor |
| 49 | Terrace |
| 50 | Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(A) Modular |
| 51 | Ground Floor |
| 52 | First Floor |
| 53 | Second Floor |
| 54 | Third Floor |
| 55 | (i) Half brick masonry in common brunt clay building bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in Ground Floor (A) Modular |
| 56 | First Floor |
| 57 | Second Floor |
| 58 | Third Floor |
| 59 | Providing, fabricating and fixing aluminium doors in singleshutter, double-shutter, sliding, semi-panelled and louvred configurations, using Cardinal or Domal Series aluminium framing system conforming to IS 733 and IS 1285. Aluminium shall have an approved wooden(wooden coating not less than grade AC 10 as per IS:1868) transparent or dyed to requied colour or shade with necessary etc, with AHPL/compact-sheet panels in an approved finish and/or toughened tinted, clear or frosted glass of the 6mm thickness. Door frames to be made of teakwood with shade of polish to match with the shade of aluminium. Approved makes of aluminium extrusions shall be Jindal, Hindalco, and approved makes of float glass shall be Modiguard, Saint Gobain, Asahi, Atul. The rate shall include AHPL/compact-sheet panels, louvres, glazing accessories, EPDM gaskets, hinges, pivots, door closers, hydraulic floor spring, handles, locks, rollers, channels and all required fixing and operating hardware, complete as per approved shop drawings and directions of the Engineer-in-Charge. |
| 60 | Providing, fabricating aluminium windows, partitions and ventilators in fixed, openable, two/three-track sliding, semi-panelled and louvred configurations, using Cardinal or Domal Series aluminium framing system conforming to IS 733 and IS 1285. Aluminium shall have an approved wooden(wooden coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary etc, with AHPL/pre-laminated panels and toughened tinted, clear or frosted glass of the 6mm thickness. Door frames to be made of teakwood with shade of polish to match with the shade of aluminium. Approved makes of aluminium extrusions shall be Jindal, Hindalco, and approved makes of float glass shall be Modiguard, Saint- Gobain, Asahi, Atul. The rate shall include AHPL/compact-sheet panels, aluminium/glass louvres, matt-black SS mosquito/pigeon-net jali in separate sliding shutter, glazing accessories, EPDM gaskets, SS hardware, drainage holes and silicone sealant for a complete watertight installation, as per approved shop drawings and directions of the Engineer-in-Charge. |
| 61 | Providing material and labour for fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and 1mm thick laminate Approved makes of : Greenlam or well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws, with Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS :2046 Type S, including cost of adhesive of approved quality 1.0mm Thick on both face, with Providing and fixing S.S. tower bolts (barrel type) with necessary screws etc 200mm long x10mm dia, with Providing and fixing S.S. Door Aldrop with necessary screws etc. 300mm long x16mm dia, Providing and fixing S.S. Door Aldrop with necessary screws etc 250mm long x16mm dia, with Providing and fixing S.S. Pipe Handle for door 30cm size on both side of Door shutter, with Providing and fixing S.S hanging type floor door stopper with necessary screws, etc. providing cut-out in door as per drawing and provision of 6mm thk fixed toughened glass in the cut-out. Door frames to be made of teakwood with shade of polish to match with the shade of aluminium complete as directed by Engineer in charge. All S.S Shall be ASIS 304 Grade. of Engineer in charge. |
| 62 | Providing and fixing FRP frame size 125x65 mm and 35mm thick FRP shutter having extra reinforcement on sides & edges in polish finish. The core of the shutter & frame is to be filed up with injected polyurethene foam done in situ alongwith embedded wooden pieces for stiffening & also taking hinges & fintures. The whole FRP frame & shutter is to be water proof weather proof, termite proof & resistance to mild acid/alkali. Rates are to be inclusive of S.S hinges with necessary screws & alluminium S.S fixtures & fastenings & fastener sleeve. Toilet doors |
| 63 | Providing, supplying, fabricating and fixing 10 mm + 1.5 mm PVB + 10 mm toughened laminated safety glass for skylight, comprising two layers of 10 mm thick toughened glass laminated with 1.5 mm PVB interlayer, including cutting, edge polishing, drilling, necessary SS/aluminium framing, structural glazing accessories, EPDM gaskets, silicone sealant, fasteners and all necessary fittings, lifting, alignment and fixing, making the whole assembly water tight, complete in all respects as per approved drawings and directions of Engineer-in-Charge. |
| 64 | Providing and fixing M.S. grills of required pattern to wooden frames of windows etc. with M.S. flats at required spacings and frame alround, square or round bars with round headed bolts and nuts or by screws (A) Plain Grill. |
| 65 | Extra above steel works for 2 coats of spray painting acrylic polyurethane enamel paint(Auto Paint including paint and all base coats) |
| 66 | Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately). Approved Makes for Floor Door Spring: Doorset,Everite,Indobrass. Approved Makes of Float Glass: Modi guard,Saint gobain,Asahi,Atul. |
| 67 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. Rate to include Polished bright bars in TGP (Turned, Ground, and Polished) finish using EN8 or C45/NC45 grades and CNC Slotting |
| 68 | Extra above steel works for 2 coats of spray painting acrylic polyurethane enamel paint(Auto Paint including paint and all base coats) |
| 69 | Structural Steel work (confirming to IS 4923-1997) riveted, bolted or welded in builtup for all type sections, in framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as per the structural designs and directions of EIC. Approved Makes for Steel : SAIL,TISCO,RINL,VIZAG. Approved Makes for Fasteners: Fischer,Hilti,Anchors. Rate to include CNC Slotting |
| 70 | Extra above steel works for 2 coats of spray painting acrylic polyurethane enamel paint(Auto Paint including paint and all base coats) |
| 71 | Providing and laying river wash kota stone slab 25 mm thick flooring as per the drawings and directed by Engineer in Charge over 20 mm (Average ) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) laid over and jointed with epoxy grout filling, rubbing and polishing etc. complete and as directed by EIC.Including groovs, Epoxy in joints As per Architecture Drawing. Stone used to be calibrated stones of uniform colour (grey/brown) as per approval of the consultant |
| 72 | Providng and laying mirror finish polished kota stone slab flooring and door window jambs over 20mm (average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or LM 1.1.5 (1-lime putty : 1.5-coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete and as directed by EIC. (A) 25mm thick. Stone used to be calibrated stones of uniform colour (grey/brown) as per approval of the consultant |
| 73 | Providng and laying mirror finish polished kota stone slab flooring over 25mm thick in risers of steps, skirting, dado and pillars laid on 10mm thick cement mortar 1:3 (1-cement : 3-coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete and as directed by EIC. The skirting stone to be flushed with plaster and finished with groove |
| 74 | Providng and laying Vitrified tiles 8 to 10mm thick, 24\\" x 24\\" in flooring, treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-cement : 3-Coarse sand) finishing with flush pointing in white cement and as directed by EIC. |
| 75 | For Vitrified tiles Size of 600 X 1200 (Base rate of 1500Rs per sqm) |
| 76 | For Vitrified tiles Size of 800 X 2400 (Base rate of 2400Rs per sqm) |
| 77 | Providng and laying Vitrified tiles 8 to 10mm thick, 24\\" x 24\\" in skirting, risers of steps and dado laid on a bed of 10mm thick cement plaster 1:3 (1-cement : 3-Coarse sand) and jointed with white cement slurry and as directed by EIC. The skirting to be flushed with plaster and finished with groove |
| 78 | For Vitrified tiles Size of 600 X 1200 (Base rate of 1500Rs per sqm) |
| 79 | For Vitrified tiles Size of 800 X 2400 (Base rate of 2400Rs per sqm) |
| 80 | Providing and laying Polished/ Leather finished Granite stone slab 16mm thick flooring as per the drawings anddirected by Engineer in-charge over 16mm (Average) thick base ofcement mortar 1:6 (1-cement : 6-coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete colour and shade as approved by architect engineer in charge. Type 1 (Base rate of 1500Rs per sqm) |
| 81 | For Type 2 granite stone (Base rate of 2000Rs per sqm) |
| 82 | For Type 3 granite stone (Base rate of 2500Rs per sqm) |
| 83 | Providing and laying 18 mm thick polished granite stone machine cut in single piece (Max. available) in sill and jambs of door Fixing with S.S. screw to the ceiling wherever necessary, urinal partitions, Seats and Steps tread and riser laid over 10 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) and jointed with grey cement slurry with matching pigment incl. rubbing and polishing half rounding edge etc. Including stepped overlap to house the aluminium windows and grooves. Including double garnite and edge polishing for nosing and seat edges, Also CNC Cutting. Complete colour and shade as approved by architect/ engineer in charge. Type 1 (Base rate of 1500Rs per sqm) |
| 84 | For Type 2 granite stone (Base rate of 2000Rs per sqm) |
| 85 | For Type 3 granite stone (Base rate of 2500Rs per sqm) |
| 86 | Providing and laying premium-grade Kesariyaji Green Marble (Verde Guatemala), 18–20 mm thick, selected from approved quarries and free from cracks or structural defects and white veins.Slabs shall be cut to required sizes and laid over a 20 mm thick cement mortar bed (1:4), including cement slurry, matching colour-pigmented epoxy jointing, diamond polishing, cleaning and sealing, complete as per approved drawings and Architect’s specifications. |
| 87 | Providing cast terrazo Flooring 22 mm thick with graded marble chips of sizes upto 6mm thick cement plaster 1:6 (1 cement : 6 coarse sand), jointed with neat cement slurry mixed with pigment to mix and match as per the instruction of the architect, including rubbing and polishing complete with Flooring. Sample to be made for approval. |
| 88 | Supplying and installing 8 mm thick wooden laminate flooring of size 1220 × 200 × 8 mm, with scratch-resistant and anti-slip surface and click-lock joint system, laid as a floating floor over approved foam/felt underlayment on a clean, dry and levelled floor. Including interlocking of planks, necessary perimeter expansion gaps, matching skirting, trims, cutting, fitting, accessories and post-installation cleaning, complete as per manufacturer's specifications and as directed by the Engineer-in-Charge. |
| 89 | Providing and applying epoxy grout for flooring tiles having joints of 3–5 mm width, using epoxy grout mix comprising 0.70 kg of organic-coated filler of approved/desirable shade, 0.10 kg of hardener and 0.20 kg of resin per kg of grout mix, including filling/grouting of joints, proper finishing, cleaning of excess grout and all labour, materials, tools and equipment, complete as per specifications and directions of the Engineer-in-Charge. |
| 90 | Providing and laying broken china mosaic flooring for terrace using 12mm to 20mm broken pieces of glazed tiles to be laid over cement mortar 1:3 to plain or slope and to be tempered to bring mortar crème out upto surface using white cement including rounding off junctions and extending them upto 15 cm along the wall, clearing with water and oxalic acid etc. as directed and as directed by EIC. |
| 91 | Providing and fixing Sandwich Type Granite Platform, comprising 18 mm thick, mirror-polished, first-quality granite stone fixed on the top and side positions, including vertical granite strip at the front, over a 25 mm thick polished Kota stone platform, with intermediate supports, fixed with approved cement mortar and adhesive as required, including cutting and making openings for fixing of sink of any size at required positions, as directed by the Engineer-in-Charge. The item shall also include providing and fixing SS 316 grade heavy-duty brackets/supports, of suitable size and spacing, properly anchored to the wall/structure with suitable SS fasteners/anchor bolts to provide adequate support to the platform, including all cutting, drilling, fixing and finishing works complete. Sizes and dimensions shall be as per Architectural Drawings and as directed by the Engineer-in-Charge. |
| 92 | Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 30cm length, 30cm height and 15cm thick of M250 grade concrete as per approved design and including excavation for fixing in proper line and level, filling the joint with C:M 1:3 (1 cement: 3 fine sand) etc. complete and as directed by EIC.Approved Makes of Kerb Stone: Dalal tiles,Unistone,Modern , Vyara. |
| 93 | Providing and fixing pre-cast shotblasted/cobble paver block 60mm thick with grade of concrete M300 pneumatic compressed / vibrated mechanically and as per approved design confirming to IS 15658 : 2006 including 35mm sand layer for levelling and filling the joint with sand in proper line and level as per guidelines of IRC : SP 63-2018 etc. complete and as directed by EIC.Approved Makes of cement: Larsen & Turbo, Gujarat, Vikram, Binani or any other make as approved by the chief engineer. Edge/margin paverblocks to be machine cut on site as per site/edge conditions. Approved Makes of Interlock Blocks: Dalal tiles,Unistone,Modern, Vyara or any other make as approved by the chief engineer. |
| 94 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 andapproved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:With average thickness of 120 mm and minimum thicknessat khurra as 65 mm. |
| 95 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of alljoints, corners, junctions of pipes and masonry with polymer mixed slurry and as directed by EIC.Approved Makes of Water Proofing: Creations,Pidilite,Cico. |
| 96 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage and as directed by EIC.Approved Makes of Water Proofing: Creations,Pidilite,Cico. (a) For vertical surface two coats @ 0.70 kg per sqm |
| 97 | (b) For horizontal surface one coat @1.10 kg per sqm |
| 98 | Providing cement vata (10 cm x 10 cm size) quarter round in cement mortar 1:1 including neat cement finishing, watering, etc. and as directed by EIC. |
| 99 | Providing and laying in situ five course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd & 4th courses of bonding material @ 1.20 kg/sqm, which shallconsist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd layer of roofing membrane APP modified Polymeric membrane 2.0 mm thick of 3.00 Kg/ sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 5th, the top most layer shall be finished with brick tiles of class designation 10grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).and as directed by EIC. |
| 100 | Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately).Approved Makes of cement: Larsen & Turbo, Gujarat, Vikram, Binani. |
| 101 | Pebble dash plaster upto 10 m height above ground level with a mixture of washed pebble or crushed stone 6 mm to 12.5 mm nominal size, dashed over and including fresh plaster in two layers under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. Exterior wall upto plinth |
| 102 | Providing 10mm thick cement plaster in single coat onbrick/concrete walls for interior plastering upto floor twolevel and finished even and smooth in (i)Cement mortar1:3 (1-cement:3-sand) .Approved Makes of cement: Larsen & Turbo, Gujarat, Vikram, Binani. |
| 103 | Second Floor |
| 104 | Third Floor |
| 105 | 20mm thick sand faced cement plaster on walls upto height 10 meters above ground level consisting of 12mm thick backing coat of C.M 1:3 (1 cement : 3 sand) and 8mm thick finishing coat of C.M 1:1 (1 cement : 1 sand) etc. complete and as directed by EIC. Sponge finish plaster. Approved Makes of cement: Larsen & Turbo, Gujarat, Vikram, Binani. on exteror works |
| 106 | Above 10 and upto 15 m |
| 107 | Above 15 and upto 17m |
| 108 | Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-sand). On ceiling |
| 109 | Extra over items for plastering on ceilings and sofits of stairs upto floor two level instead of plastering on walls. |
| 110 | Providing and fixing Chicken mesh jali (22 gauge) at the junction of 2 different surfaces of different material component at the time of plastering to prevent cracking in plaster surface as and where directed at all floors with all leads and lifts etc.complete. |
| 111 | Applying two coats of putty and two coats of primer of approved brand and manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth and as directed by EIC. |
| 112 | Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including thoroughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth and as directed by EIC.Approved Makes of Water Proofing: Creations,Pidilite,Cico. |
| 113 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied@ 2.20kg/10 sqm and as directed by EIC. |
| 114 | Applying priming coat over new steel and other metal surface after and including preparing the surface by thoroughly cleaning, oil, grease, dirt and other foreign matter and scoured with brushes fine steel wood, scarpers and sand paper with ready mixed priming paint brushing red lead and as directed by EIC.Approved Makes of Water Proofing: Creations,Pidilite,Cico. |
| 115 | Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint, brushing, interior to give an even shade inculding cleaning the surfcae of all dirt, dust and other foreign matter and as directed by EIC.Approved Makes of Water Proofing: Creations,Pidilite,Cico. |
| 116 | Polishing with french polish on new wood and wood based surface to give an even surface including cleaning the surface of all dirt, dust and sand papering smooth and including a coat of wood filler and as directed by EIC. |
| 117 | Providing and applying a multi-coat epoxy paint system on new or existing Mild Steel (MS) structural works, sections, pipes, or fabrications at all heights. Surfaces shall be prepared by wire brushing, grinding, or sandblasting to Sa 2.5 standard to remove rust and scale. The system comprises one base coat of epoxy zinc phosphate primer (minimum 50 microns DFT) followed by two coats of two-pack epoxy or aliphatic polyurethane topcoat (minimum 50 microns DFT per coat), achieving a total minimum DFT of 150 microns. Rate includes all materials, labor, scaffolding, tools, equipment, curing, and testing. |
| 118 | Providing and fixing suspended open cell false ceiling of Hunter douglas make or Armstrong Cellio - Metal/Aluminium Open Cell Ceiling-of 100x100mm cell size with all the accessories. Open Cell Ceiling :- Providing & Fixing Open cell type grid ceiling Providing and fixing in true horizontal level Open cell Aluminum lay- in ceiling tiles of size 600mmx600mmx38mm having Humidity Resistance of 100% RH, and having Fire Performance A2-s2, d0. The tile of ‘global white’ color with cell size options of 150mm (81% open area) /100mm (72% open area). The grid should be of “Armstrong” make with 15mm wide T - section flanges color white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 14 Kgs/M2. The T Sections have a Galvanizing of 90 grams per M2 & passed through 500 hrs of Salt test. The Tile & Grid system used together should carry a 15 year warrantee and as directed by EIC. INSTALLATION: To comprise main runner spaced at 1200mm centers 1975 securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum centre. The First/Last Armstrong suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centers. accessories manufactured and supplied by OEM consisting of M6 Anchor Fasteners with Vertical Hangers made of Galvanized steel of size 26 x 26 x 25 x 1.2mm with a Galvanized Thickness of 80gsm, A pre Straightened Hanger wire of dia – 2.68 mm of 1.83 m length., thickness of 80gsm and a tensile strength of 344-413 MPa, along with Adjustable hook clips of 0.8mm thick, galvanized spring steel for 2.68 mm with a minimum pull strength of 110 kg. The adjustable clip also consists of a 3.5 mm aquiline wire to be used with the main runner. |
| 119 | Providing and fixing 6 mm thick plain Calcium Silicate Board False Ceiling using full-size boards of 1830 × 1220 mm (6 ft × 4 ft) or 2440 × 1220 mm (8 ft × 4 ft), fixed over suspended GI framework comprising perimeter channels, main and intermediate channels, hangers and necessary accessories. Including joint treatment with approved tape and jointing compound for a smooth, seamless surface, cutting openings for lights and services, all screws, fasteners, edge trims, labour and incidental works, complete as per approved drawings and directions of the Engineer-in-Charge. |
| 120 | Providing and fixing 16 mm thick Bison Cement Bonded Particle Board (CBPB) false ceiling of approved make (Bison Panel/approved equivalent), manufactured from cement-bonded particles with minimum density of 1100 kg/m³, minimum bending strength of 9 N/mm², modulus of elasticity not less than 3000 N/mm², screw holding capacity of 1250 N, moisture content 9% ±3%, suitable for internal and external applications. The boards shall be fixed to a suspended GI framework comprising galvanized steel perimeter channels, intermediate channels, ceiling sections and hangers with self-drilling corrosion-resistant screws, including cutting, edge finishing, joint treatment with fibre mesh and approved jointing compound, necessary supports, scaffolding, matching with exposed RCC shade complete in all respects as per manufacturer's specifications and direction of Engineer-in-Charge. |
| 121 | Providing and fixing aluminium galvanized ceiling panels in 100mm / 150mm / 200mm width, made from minimum 0.6mm thick metal, with wood grain finish (teak/oak/walnut or approved), fixed on concealed GI/aluminium suspension system with all necessary accessories (trims, hangers, fasteners). Panels shall be pre-coated/powder-coated, rust-proof, and interlocking clip in type, installed true line and level. |
| 122 | Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position and as directed by EIC. (a) Indian Teak Wood |
| 123 | Providing, Making, Fixing / Applying Glass Fiber Reinforced Pigmented Concrete GRC Fin, Jali , gate & pergola, beam, Door of Various Sizes with perforation and as shown in drawing using well graded Approved fine quality aggregates, alkali resistant glass fibres, admixtures, water and cement including curing, Scaffolding, cleaning, preparing surfaces, junctions etc, prepare shop drawings showing fixing and methodology and arrangements, taking its approvals, modifying to suit site dimensions, taking approval of mock ups prior to installation/ fixing/ making of features and including all SS fittings, SS hardware, SS screws, SS fasteners, SS washers, SS clamps etc. complete and as directed by EIC. |
| 124 | Providing and fixing on handmade clay jalis as per design approved by architect or engineer in charge including Keraflex chemical required to stick it in existing surface , cleaning it and filling joints with required chemical and as directed by EIC. Approved Makes of clay jali: Clay club innovative or any other make as approved by the engineer incharge. |
| 125 | Providing and fixing Brick cladding in required design and patterns, in linear as well as curvilinear portions of the building all complete as per pattern provided in the architectural drawings with 20 mm thick exposed brick over 20 mm (average) thick base of adhesive mortar laid and jointed with adhesive mortar and pointing with mortar admixed with pigment of matching shade including rubbing, and polishing etc. Including special corner profiles, projection profiles etc. all complete as specified and as directed by the Engineering- Charge. Approved makes - Jalaram Bricks |
| 126 | Providing and constructing perforated/Regular brick jaali work of required pattern and design using approved first-class burnt clay bricks conforming to IS:1077, laid in cement mortar 1:4 (1 cement : 4 coarse sand) up to all floor levels. The item includes selecting uniform bricks, wetting for 24 hours, precise mechanical cutting or grinding for geometric voids, maintaining uniform joint thickness (8mm to 10mm), flush pointer finishing on all exposed faces, erecting stable double scaffolding, continuous water curing for a minimum of 7 days, cleaning mortar stains, and providing all labour, materials, tools, tackles, and incidentals. The edge/margin blocks to be machine cut. complete as per approved architectural drawings, specifications, and directions of the Engineer-in-Charge. Approved makes - Jalaram Bricks |
| 127 | Providing and fixing handmade clay block cladding / terracotta façade tiles of approved size, thickness, pattern and colour, as per architectural drawings and design approved by the Architect/Engineer-in-Charge. The work shall include preparation and cleaning of the existing substrate, application of approved Keraflex polymer-modified chemical adhesive, proper alignment, level and uniform joints, cutting and finishing at edges, corners and openings, filling and finishing of joints with compatible approved grout/chemical, cleaning of completed surface and all necessary materials, labour, scaffolding and accessories. Including special corner profiles, projection profiles etc. complete as directed by the Engineer-in-Charge. Approved makes: Clay Club Innovative. |
| 128 | Providing and fixing TIP Wood natural composite profile jaali of approved make, size, pattern and finish, as per approved architectural drawings and design. The item shall include cutting, shaping and half-slotting/notching at profile joints, including all necessary fixing hardware such as screws, clamps, brackets, supports and approved adhesives, complete with proper alignment and finishing. The rate shall include transportation, handling, cutting, wastage, scaffolding, tools, tackles, labour and all incidental works required to complete the work at site. Samples/mock-ups shall be prepared and approved by the Engineer-in-Charge (EIC) and Architect prior to execution. |
| 129 | Providing and laying cinder filling in sunken floors and other locations with approved quality cinder including watering and light ramming etc. required for proper compaction/completion of the work complete in all respects as per drawings and as directed by EIC. |
| 130 | Providing and fixing formwork including centering, shuttering, strutting, staging, propping, bracing using tubular H frames, cuplocks, stirrup heads, adjustable arrow props, adjustable acorw spans, etc. complete and including its removal at all levels for all types structural and non-structural members. The rates shall be inclusive of all tools, tackles, plant, machinery, plywood (of appropriate thickness and density, but min of 12mm thickness), bracing, supporting and also making the shuttering water tight and in correct line, level, shaoes, making drip moulds, grooves, leaving inserts etc. as per the Consultant's designs and as per the direction of EIC. Thw works shall be carried out as per the designs of the consultants. |
| 131 | Providing and fixing M.S. PIVOT Gates of required pattern fixed to brick walls / Columns prepared with M.S. flats, angles, Square / round bars, square pipes, at required spacings with necessary hold fasts, Rollers and other fixtures and fittings as per detailed drawing and fixing brick walls / coping / columns etc. complete including one coat of primer and two coats of Epoxy Paint including cleaning and finishing the surface etc. complete and as directed by EIC. |
| 132 | Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600. Upto 5 mm depth and 5 mm width. |
| 133 | Supplying & laying of drainage composite for use behind walls, between two different fills, alongside drains of road, below concrete lining of canals etc. having thermobonding a draining core - HDPE geonet comprises of two sets of parallel overlayed ribs integrally connected to have a rhomboidal shape with a polyethylene film and a nonwoven geotextile having mass per unit area 130 gsm and tensile strength of 8.0 kN/m that will be working as separation or protecting layer, geocomposite having in plane flow capacity of 0.7 L / (m.s) at hydraulic gradient of 1.0 & 20 kPa pressure and tensile strength of 13.5 kN/m , with mass per unit area of 830 gsm, at easily accessible location including top and bottom, with all leads and lifts, manpower and machinery, materials, labour etc. complete and as directed by Engineer - In - Charge. |
| 134 | Making Bulb For 350 Mm Dia Pile As Per Design At Required Depth And Sufficient Dia At Any Level, Rate Shall Be Inclusive Of All Machinery Tools And Equipmets Required |
| 135 | Pile Integrity testing equipment |
| 136 | Providing and fixing of 1.20mm thick EPDM/PVC waterbarrier membrane over the joint profile with special adhesive before fixing of the joint system to ensure water tight joints,complete in all respect. |
| 137 | Providing and fixing of 3R MSDSZJ /QSZJ - floor to floor and Floor to wall having granite/vertified top finish expansion /seismic joint system design for movement and system requiring light to medium duty load as per the usage and conforming to ASTM T6063 standards and cover concealment having superior finish and seismic movement over the joint profile as per the joint profile and as per the manufacturer speciation and the joint design and drawing ,complete , |
| 138 | Providing and fixing of expansion joint system related with wall joint(external) location as per drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221-02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System.The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063.) |
| 139 | Providing and fixing of 3R MSNSK/ 3R IL2 system designed for interior wall and ceiling finishes with expansion movement as per design for internal application on wall to wall/ceiling /wall to corner where concealed /flush metal plate is desired as per the joint design and design width over the joint profile as per the joint manufacturer speciation and the joint design and drawing ,complete , |
| 140 | Providing and fixing of 3R MSWGZ / QG terrace coping system with full expansion /seismic movement of +/- 50% design for roof finishes as per the joint design and design width over the joint profile as per the joint manufacturer speciation and the joint design and drawing ,complete |
| 141 | Providing and fixing mechanical anchor fastener of hilti make for required fitting with hilti epoxy adhesive 150*12 mm and as directed by EIC. |
| 142 | Providing & fixing in position exposed R.C.C pre cast bollard in M30 desired locations as per designs of the consultants. The bollards shall be cast in rubber lined M.S moulds. The contractor shall take approvals for the moulds from the engineer in charge prior to casting. The bollards shall be placed on 150 mm thick PCC bedding in 1:4:8 shown as per designs. The rates shall be inclusive of all materials like M30 concrete for bollards, PCC, excavation, removal of debries from the site and making the site clean. after work, marking of bollards in positiones as per the consultant's design drawings providing for and fixing 3M dimond grade retro refelectors using adhesive tapes as per the instructions of the engineer in charge, labour for all works, erection and erection equipments all tools, tackels, moulds and all lead, lifts and transportation. The works shall be carried out to the complete satisfaction of the engineer in charge. |
| 143 | Making of Pre-cast exposed RCC benches as per designs and placing the same in positions as directed using M25 grade concrete. The concrete shall be poured in pre-fab rubber lined MS moulds to form the shape of the bench and the resting blocks. The pre-cast concrete seat / becnh shall be firmly fixed at an angle as shown in the design drawings to MS spring of appropriate capacity so as to keep the seat / bench in normal position. The seat shall be further fixed over MS plate of 8mm thickness with SS screws and the plate shall be paitned with metal coat PU paint. The bench alongwith the assembly of the pre cast seat and the MS plate and spring together shall be kept on resting blocks shall be cast in seperate moulds to the most precise dimensions as per the drawings. The pre-cast exposed RCC blocks shall be placed on a level RCC (M20) base of 200mm as per the designs. The bench shall then be firmly fixed using 20mm dia polished bar MS pins with the precast blocks and the pin holes shall be filled using non-shrink cementitious grouts of approved makes. The Rates shall be inclusive of all kinds of materials like concrete, reinforcement, exposed rendering, plasticizers etc. The rates shall also include for part excavation on site to firmly place the benches in positions as required - rate per bench as per drawing. The contractor shall ensure that the moulds are cast in a proper manner so that the holes for the connecting 20mm dia pins are well co-ordinated so as to achieve a firm fixity after final placement. The bench shall be placed on the resting blocks by placing a fine layer of cement slurry. The rates shall be inclusive of the seat , spring, MS plate, bed block and shall include for all materials, labour and moulds etc. |
| 144 | Providing and laying Diamond Core cutting Required in RCC/ Bricks walls required for electric pipes/ Ac Ducts, Etc depth upto 380 mm. 2\\" Diameter and as directed by EIC. |
| 145 | Providing and laying Diamond Core cutting Required in RCC/ Bricks walls required for electric pipes/ Ac Ducts, Etc depth upto 380 mm. 3\\" Diameter and as directed by EIC. |
| 146 | Providing and laying Diamond Core cutting Required in RCC/ Bricks walls required for electric pipes/ Ac Ducts, Etc depth upto 380 mm. 4\\" Diameter and as directed by EIC. |
| 147 | Providing and laying Diamond Core cutting Required in RCC/ Bricks walls required for electric pipes/ Ac Ducts, Etc depth upto 380 mm. 5\\" Diameter and as directed by EIC. |
| 148 | Providing and laying Diamond Core cutting Required in RCC/ Bricks walls required for electric pipes/ Ac Ducts, Etc depth upto 380 mm. 6\\" Diameter and as directed by EIC. |
| 149 | Providing and laying 125 micron thick polyethylene (polythene) separation membrane of approved quality and make over the prepared DLC/PCC base for RCC road pavement, including surface preparation, overlapping of joints, cutting, laying, necessary wastage, transportation, handling, labour and all other incidental works, complete as directed by the Architect/PMC/Engineer-in-Charge. |
| 150 | Providing and fixing to wall, ceiling and floor galvanised Mild steel tubes (Medium grade) of the following ominal bore, tube fitting and clamps including making good the wall ceiling and floor.(A) 15mm |
| 151 | Providing and fixing to wall, ceiling and floor galvanised Mild steel tubes (Medium grade) of the following nominal bore, tube fitting and clamps including making good the wall ceiling and floor.(B) 20mm |
| 152 | Providing and fixing to wall, ceiling and floor galvanised Mild steel tubes (Medium grade) of the following nominal bore, tube fitting and clamps including making good the wall ceiling and floor.(C) 25mm |
| 153 | Providing and fixing to wall, ceiling and floor galvanised Mild steel tubes (Medium grade) of the following nominal bore, tube fitting and clamps including making good the wall ceiling and floor.(D) 32mm |
| 154 | Providing and fixing to wall, ceiling and floor galvanised Mild steel tubes (Medium grade) of the following nominal bore, tube fitting and clamps including making good the wall ceiling and floor.(E) 40mm |
| 155 | Providing and fixing to wall, ceiling and floor galvanised Mild steel tubes (Medium grade) of the following nominal bore, tube fitting and clamps including making good the wall ceiling and floor.(F) 50mm |
| 156 | Providing and laying in trenches galvanised mild steel tubes (Medium grade) of the following nominal bore, and tube fitting (Earthwork in trenches to be measured and paid for separately)(A) 15mm |
| 157 | Providing and laying in trenches galvanised mild steel tubes (Medium grade) of the following nominal bore, and tube fitting (Earthwork in trenches to be measured and paid for separately)(B) 20mm |
| 158 | Providing and laying in trenches galvanised mild steel tubes (Medium grade) of the following nominal bore, and tube fitting (Earthwork in trenches to be measured and paid for separately)(C) 25mm |
| 159 | Providing and laying in trenches galvanised mild steel tubes (Medium grade) of the following nominal bore, and tube fitting (Earthwork in trenches to be measured and paid for separately)(D) 40mm |
| 160 | Providing and laying in trenches galvanised mild steel tubes (Medium grade) of the following nominal bore, and tube fitting (Earthwork in trenches to be measured and paid for separately)(E) 65mm |
| 161 | Providing and laying in trenches galvanised mild steel tubes (Medium grade) of the following nominal bore, and tube fitting (Earthwork in trenches to be measured and paid for separately)(F) 80mm |
| 162 | Making connection of galvanised Mild steel distribution branch with galvanised mild steel main 50mm to 80mm nominal bore by providing and fixing tee including cutting and threading the pipes complete. |
| 163 | Providing and fixing to wall ceiling and floor 6.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(A) 20mm |
| 164 | Providing and fixing to wall ceiling and floor 6.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(B) 25mm |
| 165 | Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(C) 32mm |
| 166 | Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(D) 40mm Wash Out Pipe |
| 167 | Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(E) 50mm Wash Out Pipe |
| 168 | Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure polythene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(F) 75mm ( Waste Pipe & Rain & Balcony Drain) |
| 169 | Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(G)110 mm ( Rain & Balcony Drain) |
| 170 | Providing and fixing water closet squatting Pan (Indian type W.C. Pan) size 580mm (Earthwork, bed concrete, foot reste and trap to be measured and paid for separately) (A) Vitreous China.(I) Long pattern = White colour |
| 171 | Providing and fixing wsh down water closet (European type, W.C. Pan) with integral P or S trap including jointing the trap with soil pipe in Cement Mortar 1:1 (1-Cement : 1-fine sand) (Seal and cover to be measured and paid for separately)(A) vitreous China Pattern :(i) in white colour |
| 172 | Providing and fixing 100mm size P or S trap for water closet squatting pan including jointing the trap with the pan and soil pipe in cement Mortar 1:1 (1-Cement : 1-Fine sand)(A) Vitreous China. |
| 173 | Providing and fixing in Cement Mortar 1:3 (1-Cement : 3-coarse sand)a, pair of white vitreous China 250mm x 130mm x 30mm footrest to long pattern squatting pan water closet. |
| 174 | Providing and fixing ( Dual Flush Type ) ( 6ltr & 12.5 Litres )low level flushing cistern with a pair, of C.I. or Mild brackets, complete with fittings such as lead valve less syphon, 15mm nom.nal size brass ball valve with polythene float, C.P brass handle unions and couplings for connections, with inlet, outlet and overflow pipes, 40mm dia. porcelain enamelled flush bend including cutting holes in walls and making good the same connecting the flush bend with cistern and closet (overflow pipe to be measured and paid for separately)(A) Vitreous China (I) In white colour |
| 175 | Providing and fixing 12.5 Litres high level C..I. flushing cistern with A pair of C.I. or Mild steel brackets, womplete with fittings such as syplionic arrangement, 15mm nominal size brass ball valve with polythene float, lever G.I. China (60 cm. ) and pull union and couplings for connections with inlet, outlet and overflow pipes etc. including cutting holes in walls and making good the same (overflow pipe to be measured and paid fo separately ) |
| 176 | Providing and fixing in position with clamps etc. 32mm nominal internal diameter galvanised steel tube flush pipe for high level flushing cistern including connecting the flush pipe with cistern and closet and making good the walls and floors. |
| 177 | Providing and fixing G.I. inlet connection for flush pipe with W.C. Pan |
| 178 | Providing and fixing plastic seat and cover for wash down water closer with C.P. brass hinges and rubber buffers. (B) Black plastic seal and cover. |
| 179 | Providing and fixing washbasin with single hole for pillar tap with C.I. or M.S. brackets painted white including sutting holes and making good the same but excluding fittings.(A) Vitreous China:(ii) Flat Back washbasin 550 mm x v 400mm size. (i) In white colour. |
| 180 | Providing and fixing Kitchen sink with C.I. or M.S. brackets, painted white including cutting holes in walls and making good the same but excluding fittings. (C) Vitreous China Sink.(i) 600mm x 450mm x 150mm size |
| 181 | Providing and fixing C.P. brass waste for washbasin or sink. (A) 32mmdia. |
| 182 | Providing and fixing C.P. brass waste for washbasin or sink. (B) 40mm dia. |
| 183 | Providing and fixing M.I. fisher union for washbasin or sink. (A) 32mm dia. |
| 184 | Providing and fixing M.I. fisher union for washbasin or sink. (B) 40mm dia. |
| 185 | Providing and fixing 100mm sand cast iron grating for gully, floor or Nahni trap. |
| 186 | Providing and fixing C.P. brass shower rose with 15mm or 20mm inlet.(A) 100mm dia. Each |
| 187 | Providing and fixing 600mm x 450mm bevelled edge mirrror of superior glass mounted on 6mm thick A.C. sheet or plywood sheet and fixing to wooden pluge with C.P. brass screws and washers. |
| 188 | Providing and fixing C.P. brass towel rail comlete with C.P. brass brackets fixed to wooden plugs with C.P. brass scews.(B) 600mm x 20mm size. |
| 189 | Providing and fixing 600mm x 120mm glass shelf with C.P. brass bracket and guard rail complete mixed to wooden plug with C.P. brass screws. |
| 190 | Providing and fixing screw down bib taps of following size.(A) Brass screw down bib tap polished bright. (i) 15mm dia. |
| 191 | Providing and fixing screw down bib taps of following size.(A) Brass screw down bib tap polished bright. (ii) 20mm dia. |
| 192 | Providing and fixing screw down bib taps of following size.(B) Brass chromium plated screws down Bib Tap. (i) 15mm dia. |
| 193 | Providing and fixing screw down bib taps of following size.(B) Brass chromium plated screws down Bib Tap. (ii) 20mm dia. |
| 194 | Providing and fixing screw down bib taps of following size.(C) Gun metal screw down bib tap. (i) 15mm dia. |
| 195 | Providing and fixing screw down bib taps of following size.(C) Gun metal screw down bib tap. (ii) 20mm dia. |
| 196 | Providing and fixing pillar tap, capstan head, screw down high pressure with screws, shanks and back nuts. (i) 15mm dia. |
| 197 | Providing and fixing pillar tap, capstan head, screw down high pressure with screws, shanks and back nuts. (ii) 20mm dia. |
| 198 | Providing and fixing brass screw down stop tap.(A) 15mm dia. |
| 199 | Providing and fixing brass screw down stop tap.(B) 20mm dia. |
| 200 | Providing and fixing brass screw down stop tap.(C) 25mm dia. |
| 201 | Providing and fixing Gun metal check or non-return fullway wheel valve.(A) 15mm dia. |
| 202 | Providing and fixing Gun metal check or non-return fullway wheel valve.(B) 20mm dia. |
| 203 | Providing and fixing Gun metal check or non-return fullway wheel valve.(C) 25mm dia. |
| 204 | Providing and fixing Gun metal check or non-return fullway wheel valve.(D) 32mm dia. |
| 205 | Providing and fixing Gun metal check or non-return fullway wheel valve.(E) 40/50 mm dia. |
| 206 | Providing and fixing chromium plated brass half trun flush cock of approved quality including fixing in pipe line etc. complete.(i) 20mm dia. |
| 207 | Providing and fixing chromium plated brass half trun flush cock of approved quality including fixing in pipe line etc. complete.(ii) 25mm dia. |
| 208 | Providing and fixing chromium plated brass half trun flush cock of approved quality including fixing in pipe line etc. complete.(iii) 32mm dia. |
| 209 | Providing and fixing Urinal or approved quality including conecting the Urinal with waste pipe , tap etc. complete.(A) White earthenware flat back or corner type size 430mm x 260mm x 350mm. |
| 210 | Providing and fixing Urinal of approved quality including connection with trap and with integral longitudinal flush pipe.(A) Squating plate pattern white earthenware 550mm x 300mm. |
| 211 | Providing and fixing Rubber plug for sink or wash basin. |
| 212 | Providing and fixing chromium plated, bottle trap with necessary couplings of approved quality for wash basin. |
| 213 | Providing and fixing ball cock of approved. quality as directed.(A) Copper Metal (i) 25mm dia. |
| 214 | Providing and fixing ball cock of approved. quality as directed.(A) Copper Metal (ii) 50mm dia. |
| 215 | Providing and fixing ball cock of approved. quality as directed.(B) Abonite (i) 25mm dia. |
| 216 | Providing and fixing ball cock of approved. quality as directed.(B) Abonite (ii) 50mm dia. |
| 217 | Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. size having weight not less than 35Kg. |
| 218 | Providing and fixing G.I. Rain water spout of 50mm dia. and 30cm. length. |
| 219 | Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete.[A] 15 mm. |
| 220 | Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [B] 20 mm. |
| 221 | Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [C] 25 mm. |
| 222 | Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [D] 32mm. |
| 223 | Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [E] 40mm. |
| 224 | Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [F] 50mm. |
| 225 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. External -Underground - piping Works :- 65mm Dia. |
| 226 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. External -Underground - piping Works :- 80mm Dia. |
| 227 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. External -Underground - piping Works :-100mm Dia. |
| 228 | Providing laying and jointing in true line and level 15mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 229 | Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 230 | Providing laying and jointing in true line and level 32mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 231 | Providing laying and jointing in true line and level 40mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 232 | Providing laying and jointing in true line and level 50mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 233 | Providing, laying and jointing in true line and level 160 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 160 mm diametre x 210 mm length x 196 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. |
| 234 | Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. |
| 235 | Providing and fixing PVC SWR P-Trap/ Nahni trap IS 14735 for drain - 100 mm diameter with jali of the following nominal diameter of self cleansing design with C.I scread down or hinged grating including the cost of cutting and making good the walls. |
| 236 | Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 75 mm diameter with jali of the following nominal diameter of self cleansing design with C.I scread down or hinged grating including the cost of cutting and making good the walls. |
| 237 | Providing and fixing white vitreous china extended wall mounted water closet (European type) of size 370 x 535 x 405 mm of approved shape including seat and lid, fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved design complete, including chair brackets, nuts, rag bolts, painting of fittings and brackets, cutting and making good the walls and floors wherever required. Wall mounted water closet of Jaquar : CNS-WHT-959NN , Health Faucet ALD-CHR-573 or Equivalent approved Make . ( Cera/ Jauar/Hindware/Parryware or Eq. Make) |
| 238 | Providing & fixing of first quality white vitreous china Oval type Wash basin as per product detail, including specially fabricated C.I. brackets with studs painted with two or three coats of enamel paint of approved shade over a coat of primer complete including filling gap between counter and wash basin with approved sanitary grade material, cutting & making good the walls where required to the complete satisfaction of the Engineer in Charge. Oval Wash Basin of Jaquar - FLS-WHT-5701; Rag Bolts for Wash Basins, Bottle Trap: Jaquar ALD-769L300x190, Waste Coupling: Jaquar: Cat. No.: ALD-705, Prismatic Pillar Cock: Jaquar PRS-031 or Equivalent approved Make . ( Cera/ Jauar/Hindware/Parryware or Eq. Make) |
| 239 | Providing & fixing of first quality white vitreous china Wash basin as per product detail, including specially fabricated C.I. brackets with studs painted with two or three coats of enamel paint of approved shade over a coat of primer complete including filling gap between counter and wash basin with approved sanitary grade material, cutting & making good the walls where required to the complete satisfaction of the Engineer in Charge. Wash Basin CNS-WHT-811; Rag Bolts for Wash Basins, Bottle Trap: Jaquar ALD- 769L300x190, Waste Coupling: Jaquar: Cat. No.: ALD-705, Prismatic Pillar Cock: Jaquar PRS-031 or Equivalent approved Make . ( Cera/ Jauar/Hindware/Parryware or Eq. Make) |
| 240 | Providing and fixing white vitreous china flat back urinal of approx. size 375 x 315 x 620mm having water inlet & outlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. Urinal: Jaquar Make URS-WHT-13253O, Urinal FlushPRS-073 or Equivalent approved Make . ( Cera/ Jauar/Hindware/Parryware or Eq. Make) |
| 241 | Providing & fixing of Health faucet with Angular Cock Assembly( Cera/ Jauar/Hindware/Parryware or Eq. Make) (JAQUAR- ALLIED ALD 565 - CHROME) |
| 242 | Handicaped ToiletProviding and Fixing Handicap Toilet set including EWC, Cistern, Seat Cover, Fittings, Washbasin,, Hinged Rail, Grab Bar and Faucet with Spatula Lever including Cast Iron chair backed and necessary bolts and nuts complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required to the satisfaction of Engineer-In-Charge. Special Needs Toilet Set: Jaquar - CNS-WHT- 755SN + Cistern Set CNS-WHT-207, Wash Basin CNS-WHT-811 & Grab Bar 2 No. - WAC-WHT-BG0800 & WAC-WHC-BR0600 - 2 nos.+ or Equivalent approved Make ( Cera/ Jauar/Hindware/Parryware or Eq. Make) |
| 243 | Providing and fixing 2 Nos. support arms and backrest to mount at fixed height (Commander or equivalent) for handicap toilet complete as recommended by the E-I-C. ( Cera/ Jauar/Hindware/Parryware or Eq. Make) |
| 244 | Providing and fixing raised toilet seat with cover for handicap toilet (Commander or equivalent) as recommended by the E-I-C ( Cera/ Jauar/Hindware/Parryware or Eq. Make) |
| 245 | Providing and fixing brackets, tracks with flexible feed & waste pipes for adjustable type wash basin complete as recommended, for handicap toilet (Commander or equivalent) ( Cera/ Jauar/Hindware/Parryware or Eq. Make) |
| 246 | Providing and fixing white vitreous china extended wall mounted water closet (European type) of size 490 x 350 x 330 mm of approved shape including seat and lid, fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved design complete, including chair brackets, nuts, rag bolts, painting of fittings and brackets, cutting and making good the walls and floors wherever required. Wall mounted water closet of Compact with cintia soft close seat cover Wall hung EWC with ceat cover Cat. No. B1520102 Cintia,soft close seat cover,Cat No. : S1043153, Health Faucet ALD-CHR-573 or Equivalent approved Make . ( Cera/ Jauar/Hindware/Parryware or Eq. Make)- Compact Model-Closet- |
| 247 | Supplying Installing & fixing white vitreous china flat back urinal of size 590x375x390mm as per IS-2556 (Part-2 ) with C.I. hangers and 15mm dia. C.P. spreader,15MM cCP angular Stop Cock ,Flexible pipe Connecion, 32mm dia CP bottle trap and pipe to wall with C.P. flange complete including cutting and making good the walls and floors wherever required. Jaquar-URS-WHT-13255 Urinal Without Sensor With Fixing Accessories, Size: 480x300x740 mm ( Jaquar, Kohler, Cera or Eq. ) |
| 248 | Supplying Installing & fixing of concealed type urinal sensor with concealed body, divertor, cock with wall flange and complete., for the following sizes. SNR-STL-51087 Sensor Concealed Type Flushing Valve for Urinal Complete Set with Installation Box with Control Cock (Battery Operated) ( Jaquar, Kohler, Cera or Eq. ) |
| 249 | Supplying Installing & fixing of Flush Valve Auto operation cock with wall Flange 32mm with lever knob complete in all respects including cutting and making good the walls etc. FLV-1085NMetropole Flush Valve Dual Flow 32mm Size (Concealed Body) with Exposed Shut Off Provision & Round Flange (3.0/6.0 Lts. Per Flushing) ( Jaquar, Kohler, Cera or Eq. ) |
| 250 | Supplying Installing & fixing of Pressmatic open type anguler cock concealed flush Valve Auto operation cock with wall Flange 15mm with lever knob complete in all respects including cutting and making good the walls etc. for Urinal area Flsuh :- PRS-077Urinal Valve Auto Closing System with Built-in Control Cock & Wall Flange ( Jaquar, Kohler, Cera or Eq. ) |
| 251 | Supplying Installing & fixing of Pressmatic open type Bib Tap wall Monted type Auto operation cock with wall Flange 15mm with lever knob complete in all respects including cutting and making good the walls etc. for Press Matic Bib cock- Wall Mounted :- PRS-043 Bib Cock Auto Closing System withBuilt-in Control Cock With Wall Flange ( Jaquar, Kohler, Cera or Eq. ) |
| 252 | Supplying Installing & fixing stainless steel sink, R.S. or C.I. Painted brackets painted, 40mm dia. C.P. waste, C.P. brass chain and rubber plug, strainer with necessary C.P. brass unions complete including painting the fittings and cutting and making good the walls wherever required, with CP sink cock with raised \\"J\\" shaped swinging spout. NIRALI - GRACE - PLAIN - 510 X 432 MM (ONLY BOWL) SINK COCK WALL MOUNTED WITH J-SHAP SWIING OPERATION - ( Nirali-Jaquar, Kohler, Cera or Eq. ) |
| 253 | Providing and fixing 9 mm thick nitrial electrometic insulation tube over pipes in wall chase and filling the wall chase as per manufature's specifications for hot water insulation with over aluminium tape covering over the insulation. Open Line work : covered installation/) (Tharmaflex, Accoflex, Superloan Makes)15mm pipe Size |
| 254 | Providing and fixing 9 mm thick nitrial electrometic insulation tube over pipes in wall chase and filling the wall chase as per manufature's specifications for hot water insulation with over aluminium tape covering over the insulation. Open Line work : covered installation/) (Tharmaflex, Accoflex, Superloan Makes)20mm pipe Size |
| 255 | Providing and fixing 9 mm thick nitrial electrometic insulation tube over pipes in wall chase and filling the wall chase as per manufature's specifications for hot water insulation with over aluminium tape covering over the insulation. Open Line work : covered installation/) (Tharmaflex, Accoflex, Superloan Makes)25mm pipe Size |
| 256 | Providing and fixing 9 mm thick nitrial electrometic insulation tube over pipes in wall chase and filling the wall chase as per manufature's specifications for hot water insulation with over aluminium tape covering over the insulation. Open Line work : covered installation/) (Tharmaflex, Accoflex, Superloan Makes)32mm pipe Size |
| 257 | Providing and fixing 9 mm thick nitrial electrometic insulation tube over pipes in wall chase and filling the wall chase as per manufature's specifications for hot water insulation with over aluminium tape covering over the insulation. Open Line work : covered installation/) (Tharmaflex, Accoflex, Superloan Makes)40mm pipe Size |
| 258 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore |
| 259 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore |
| 260 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore |
| 261 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore |
| 262 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 263 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore |
| 264 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore |
| 265 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts 100mm dia. Class.II |
| 266 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore |
| 267 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore |
| 268 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore |
| 269 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : Vertical : 25 mm nominal bore |
| 270 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : Vertical : 32 mm nominal bore |
| 271 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : Vertical : 40 mm nominal bore |
| 272 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : Vertical : 50 mm nominal bore |
| 273 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : Vertical : 65 mm nominal bore |
| 274 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : Vertical : 80 mm nominal bore |
| 275 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 276 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 50 mm dia |
| 277 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 80 mm dia |
| 278 | Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 80 mm dia nominal bore |
| 279 | Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 100 mm dia nominal bore |
| 280 | Making holes upto 50mm dia. 300mm long in any RCC members by diamond Core Cutting machine of HILTI or equivalent including disposing the debries,all works refinishing of the GP-2 pipe grout complete with water proof testing etc completed as directed by E.T.C/PMC . |
| 281 | Making holes upto 100mm dia. 300mm long in any RCC members by diamond Core Cutting machine of HILTI or equivalent including disposing the debries,all works refinishing of the GP-2 pipe grout complete with water proof testing etc completed as directed by E.T.C/PMC .. |
| 282 | Making holes upto 150mm dia. 300mm long in any RCC members by diamond Core Cutting machine of HILTI or equivalent including disposing the debries all works refinishing of the GP-2 pipe grout complete with water proof testing etc completed as directed by E.T.C/PMC . |
| 283 | PVC PIPE SLEEVE WORK DURING CONSTRUCTION PHASE:-Providing and fixting of the PVC -6kg. pipe sleeves of 75mm,100mm&150mm dia pipe during civil work casting works, the lenght of pipe should be 450mm and 300mm as per the requirments, the sleeve works must be coordinated with the civil agency, beam, sleeves, slab and RCC reating walls etc. complete as directed by EIC/Architect |
| 284 | SITC of Heavy duty PVC flexible pipe of 25mm dia with 15 meter length , the pipe shouble be included Gunmetal hose nozzel at the termination point. For gaden manual irrigation purpose. As per the site eng. incharge and as per the guide line o be execute. (Pipe:- Ashirvad, Kissan, Supreme, valve RB, Zoloto, Audco or Eq. Make) |
| 285 | CENTRIFUGAL PUMPS ,Suppying, installing, testing and commissioing of centrifugal monoset submersible pumps with c.i. casing, Bronze impeller, SS Shaft and driven by 415 V AC, 3 phase, 50HZ., motor running at 2900 rpm speed and shall be supplied with all accessories viz., base plate, coupling, motor, starter panel, cabling up to panel, dry ru protection, auto level sensor float switch operation,earthing,delivery & header pipes & valves etc., complete.. (UG tank to OHT feede and Softener Inlet Set ) ( Make Grundfos / ITT Lowara or Eq.)Capacity : 20.0 mtr3/hr. x 25mtr. head 1 working 1 stand by set. |
| 286 | WATER COOLER PLANT ; Supply, installation, testing & commissioning of S.S. storage type water cooler with on line U.V. fultration along with built in booster pumps all intercnnectio piping, supports and valve and other electrical requirment ,along with inbuilt storage tank with nessesarry accessories, safety valve, air valve, drain arrangement, all insturumentation, base frame, necessary electrification, etc. complete for Drinking Water supply. ( Kitchen Area ) ( Voltas, Blu star, Power H2o Make) Capacity : 150 storage capacity. Complete as directed by EIC/Architect |
| 287 | WATER COOLER PLANT ; Supply, installation, testing & commissioning of S.S. storage type water cooler with on line U.V. fultration along with built in booster pumps all intercnnectio piping, supports and valve and other electrical requirment ,along with inbuilt storage tank with nessesarry accessories, safety valve, air valve, drain arrangement, all insturumentation, base frame, necessary electrification, etc. complete for Drinking Water supply. ( Pantry Area ) ( Voltas, Blu star, Power H2o Make) Capacity : 50 storage capacity. Complete as directed by EIC/Architect |
| 288 | Hydro Pneumatic Pressure Pump ( Domestic Water ) Suppying, installing, testing and commissioing of Vertical Multistage Booster Pump with c.i. casing, Bronze impeller, SS Shaft and driven by 415 V AC, 3 phase, 50HZ., motor running at 2900 rpm speed and shall be supplied with all accessories viz., base plate, coupling, motor, starter panel, cabling up to panel, earthing,delivery & header pipes & valves etc., complete. (Domestic Pressure Pump at Terrace lvl. & R.O. Water Supply )( Grundfos, ITT Lowara, or Eq.Make)Capacity : 7.50mtr3/hr.2 Nos. pumps ( 2 Working + 1 Stand by Set)Head : 40 mtr. Booster Tank 100 ltr. |
| 289 | BORE WELL:-Supply installation, testing, commissioning of Bore well submersible pump to be installed in the tube well of required indicated capacity and head as per relevant IS for Bore water lifting with suitable submersible vet type, water cooled, squirrel case motor conforming to IS 9283, working of 3-phase, 50Hz +/- 3% 415 VAT +/- 10%, AC supply 2900 RPM synchronous speed with 10mtr. copper conductor flat cable from pump to starter panel with cables and termination ( all supports clamps pipe fittings mechanical seal, bearing, bush, strainer, etc. comp., Casing C.I., S.S. CF8M impeller, bronze casing, wearing and bearing bush, TC mechanical seal, S.S. bearing, S.S. shaft with sleeve, S.S. strainer, and M.S. morter along with water guard, single phase preventor with all cables of appropriate size control and instrumentations, switches, testing, and installation along with testing. The scope shall also include delivery isolation valve & NRV with PVC piping (400 dia Drill well @200mm dia MS. heavy class pipe : BORE WELL) Assume 100 TO 125mtr depth) ( 20 TO 25 MTR CU. PER HR. OUT PUT FLOW RATE with potable water quality ) (15 TO 20HP PUMP.) |
| 290 | PUDDLE SLEEVES:-Providing & Installing of the G.I. heavy duty Puddle Sleeve in the UGT & OHT water tanks , durring the construction of the RCC tanks. The pipe and flazes nut bolt material are as per the IS recommondation must be follow. all works must properly finishing as per site eng. Incharge slab & Beams where ever req. 200 mm pipe dia x 600mm length |
| 291 | PUDDLE SLEEVES:-Providing & Installing of the G.I. heavy duty Puddle Sleeve in the UGT & OHT water tanks , durring the construction of the RCC tanks. The pipe and flazes nut bolt material are as per the IS recommondation must be follow. all works must properly finishing as per site eng. Incharge slab & Beams where ever req. 150 mm pipe dia x 600mm length |
| 292 | PUDDLE SLEEVES:-Providing & Installing of the G.I. heavy duty Puddle Sleeve in the UGT & OHT water tanks , durring the construction of the RCC tanks. The pipe and flazes nut bolt material are as per the IS recommondation must be follow. all works must properly finishing as per site eng. Incharge slab & Beams where ever req. 100 mm pipe dia x 600mm length |
| 293 | PUDDLE SLEEVES:-Providing & Installing of the G.I. heavy duty Puddle Sleeve in the UGT & OHT water tanks , durring the construction of the RCC tanks. The pipe and flazes nut bolt material are as per the IS recommondation must be follow. all works must properly finishing as per site eng. Incharge slab & Beams where ever req. 80 mm pipe dia x 600mm length |
| 294 | PUDDLE SLEEVES:-Providing & Installing of the G.I. heavy duty Puddle Sleeve in the UGT & OHT water tanks , durring the construction of the RCC tanks. The pipe and flazes nut bolt material are as per the IS recommondation must be follow. all works must properly finishing as per site eng. Incharge slab & Beams where ever req. 50 mm pipe dia x 450mm length |
| 295 | APPROVAL WATER SUPPLY SERVICES CONNECTION FROM LOCAL AUTHORITYGetting of Water supply connection of nearest water point from Approval from local drainage & water authority with all other charges and documentations for getting No Objection Certificate. |
| 296 | SITC of Heavy duty PVC flexible pipe of 25mm dia with 15 meter length , the pipe shouble be included Gunmetal hose nozzel at the termination point. For gaden manual irrigation purpose. As per the site eng. incharge and as per the guide line o be execute. (Pipe:- Ashirvad, Kissan, Supreme, valve RB, Zoloto, Audco or Eq. Make) |
| 297 | SITC of Spray Pop Up Sprinkler 3 to 5 Meter Radius of Hunter/Rain Bird / Toro make |
| 298 | SITC of Spray Pop Up Dripper/Bubller 1.5 to 3 Meter Radius of Hunter/Rain Bird / Toro make |
| 299 | SITC of Swing Joing 3/4\\" of Hunter/Rain Bird / Toro make |
| 300 | SITC of Swing Joint 1/2\\" of Hunter/Rain Bird / Toro make |
| 301 | SITC of PP Clamp Saddle 3/4\\" PN 16 of Astore/Cepex make |
| 302 | SITC of PP Clamp Saddle 1/2\\" PN 16 of Astore/Cepex make |
| 303 | SITC of Double Acting Air Release Valve 1\\" of ARI/AZUD/R.B. OR EQ. make |
| 304 | Supply and installation of open drip piping consits of 16mm dia drip lines of length 20m connected to 23 m long 37.5 MM HDPE lateral capped at the end per block, as per Engineer instruction. Including 16mm drip lines , End drip caps fittings, Rubber drip fitings, Offtake connectors drip fittings, 50 MM Main screen filter,Start connectors without rubber,Start connectors with rubber( Jain,Dutron, Price, Kissan Make) |
| 305 | Providing and laying (to level or slopes) and jointing with stiff mixture of Cement Mortar in proportion 1:1 Selt glazed stoneware pipes including testing of pipes and joints complete.(A) 100mm dia. (upto 10 ton) |
| 306 | Providing and laying (to level or slopes) and jointing with stiff mixture of Cement Mortar in proportion 1:1 Selt glazed stoneware pipes including testing of pipes and joints complete.(B) 150mm dia. (upto 10 ton) |
| 307 | Providing and laying Cement concrete 1:5:10 (1-Cement : 5-Fine sand :10-Graded stone aggregate 40mm nominal size) bedding for stoneware pipes of following internal diameters with necessary formwork and curing complete.(A) 100 mm dia. (112 mm Ave.bed thickness) |
| 308 | Providing and laying Cement concrete 1:5:10 (1-Cement : 5-Fine sand :10-Graded stone aggregate 40mm nominal size) bedding for stoneware pipes of following internal diameters with necessary formwork and curing complete.(B) 150mm dia. (166mm Ave. bed thickness) |
| 309 | Providing and laying lime concrete 1:2:4 (1-Lime putty :2-Fine samd : 4-Graded brick aggregates 40mm nominal size) bedding for stoneware pipes of following internal diameters with necessary formwork and curing complete.(A) 100 mm dia. 300mm width (112 mm Ave.bed thickness) |
| 310 | Providing and laying lime concrete 1:2:4 (1-Lime putty :2-Fine samd : 4-Graded brick aggregates 40mm nominal size) bedding for stoneware pipes of following internal diameters with necessary formwork and curing complete.(B) 150mm dia. 450mm width (166mm Ave. bed thickness) |
| 311 | Extra over item 24.1 for providing salt Glazed stoneware fittings.(i) Bends of required degree (any redious) of following nominal diameters. (A) 100mm dia. (upto 10 ton) |
| 312 | Extra over item 24.1 for providing salt Glazed stoneware fittings.(i) Bends of required degree (any redious) of following nominal diameters.(B) 150mm dia. (upto 10 ton) |
| 313 | Extra over item 24.1 for providing salt Glazed stoneware fittings.(ii) Taper bend of required degree of following internal diameters.(A) 100mm x 150mm (upto 10 ton) |
| 314 | Extra over item 24.1 for providing salt Glazed stoneware fittings.(iii) Single Junction of required angle of following internal diametrs. (A) 100mm. (upto 10 ton) |
| 315 | Extra over item 24.1 for providing salt Glazed stoneware fittings.(iii) Single Junction of required angle of following internal diametrs. (B) 150mm. (upto 10 ton) |
| 316 | Providing and laying jointing and pointing with stiff mixture of Cement Mortar 1:1 (1-Cement : 1-Fine sand) 150 mm internal diameter salt glazed stoneware half round channels. (upto 10 ton) |
| 317 | Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight.(i) Square mouth traps. (A) 100mm x 100mm size P type. (upto 10 ton) |
| 318 | Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight.(i) Square mouth traps.(B) 150mm x 100mm size P or R type |
| 319 | Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(B) 150mm (upto 10 ton) |
| 320 | Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(C) 250mm (upto 10 ton) |
| 321 | Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(D) 300mm (upto 10 ton) |
| 322 | Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(E) 450mm |
| 323 | Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (1) A type depth 0.90 Metre for 150mm diameter sewer. |
| 324 | Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (2) B type depth 1.50 Metre for 150mm diameter sewer. |
| 325 | Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (3) C type depth 2.25 Metre for 150mm diameter sewer. |
| 326 | (A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (4) D type depth 3.15 Metre for 150mm diameter sewer. |
| 327 | (I) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. or Part thereof over item No.24.27 (I) for depth from 0.9M to 1.5M. |
| 328 | (II) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. GR Part thereof over item No.24.27 (I) for depth from 1.50M. to 2.25M. |
| 329 | (III) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. or Part thereof over item No. 24.27 (III) for depth from 2.25M to 3.15M. |
| 330 | (IV) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. or Part thereof over item No. 24.27 (IV) for depth above 3.15M. |
| 331 | Providing and fixing cast iron steps of size 500mm x 150mm x 22.5mm and painting with two coats of Anti-corrosive paint etc. complete. |
| 332 | Supplying and fixing C.I. cover 300mm x 300mm without frame for Gulley trap (Standard pattern) te weight of cover to be not less 4.53 Kg.) (upto 10 ton) |
| 333 | Providing and erecting at the site of work steel ventilating column of 150m internal diameter and 12.20 Metre High from G.L. to bottom of top grill including C.I. grill and base plate bolts and nuts etc. and excavation in foundation of size 120cm. x 120vcm. x 165cm. and filling the pit with first layer of cement concrete 1:3:6 mix (1-cement :3-coarse sand :6-graded stone aggregate 20mm nominal size) of 120cm. x 120cm. x 90cm. and remaining pit with B.B.C. 1:3:6 mix (1-cement :3-coarse sand:6-Brickbats 40+50mm size) and providing fillet in Cement concrete 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm. nominal size) at G.L. and 3 coats of silver paint etc. complete. (upto 10 ton) |
| 334 | Constructing Brick masonry road gully chamber 500mm x 450mm x 600mm including 500mm x 450mm C.I. horizontal grating wih frame complete. (upto 10 ton) |
| 335 | Constructing Brick masonry road gully chamber 450mm x 450mm x 775mm with vertical gating complete. |
| 336 | Constructing brick masonry road gully chamber 1100mm x 775mm including 500mm x 450mm (C.I. horizontal grating with frame and vertical grating complete.) (upto 10 ton) |
| 337 | Constructing brick masonry chamber for underground C.I. Inspection chamber and bends with briocks having croshing strength not less than 35Kg. Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete.(i) Inside dimensions 455mmx 610mm and 450mm deep for single pipe line. (upto 10 ton) |
| 338 | Constructing brick masonry chamber for underground C.I. Inspection chamber and bends with briocks having croshing strength not less than 35Kg. Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete.(ii) Inside dimensions 500mm x 700 mm and 450mm deep for pipe line with one or two inlets. (upto 10 ton) |
| 339 | Constructing brick masonry chamber for underground C.I. Inspection chamber and bends with briocks having croshing strength not less than 35Kg. Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete.(iii) Inside dimensions 600mm x mm and 450mm deep for pipe lines with three or more inlets. (upto 10 ton) |
| 340 | Extra over items 24.44 for every additional depth of 0.1M. of part thereof beyond 450mm depth for Brick masonry chamber.(i) for 455mm x 610mm size. |
| 341 | Extra over items 24.44 for every additional depth of 0.1M. of part thereof beyond 450mm depth for Brick masonry chamber.(ii) for 500mm x 700mm size. |
| 342 | Extra over items 24.44 for every additional depth of 0.1M. of part thereof beyond 450mm depth for Brick masonry chamber.(iii) for 600mm x 850mm size. |
| 343 | (A) Providing sock pit of 2.00 Cu.M. Volume including excavating and filling brickbats with dry masonry work at top for 45cm. height including covering the top with stone including providing vatas in C.M. 1:3 with finishing curing etc. complete as directed. (upto 10 ton) |
| 344 | (B) Providing sock pit of 5.00 Cu.M. Volume including excavating and filling brickbats with dry masonry work at top for 45cm. height including covering the top with stone including providing vatas in C.M. 1:3 with finishing curing etc. complete as directed. (upto 10 ton) |
| 345 | Constructing water tight brick masonry grease trap with second class bricks in cement mortar 1:4 (1 cement :4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size, foundation concrete 150 mm thick 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement & FRP. foot rests including fixing in 20 x 20 x 10 cm cement concrete blocks 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20 mm nominal size), two brick masonry baffle walls each of 500 mm depth & third one 600 mm deep each of 115 mm thickness, 1 No. cast iron double seal manhole cover with frame (internal size 455 x 610 mm & total weight of cover & frame to be not less than 38 kgs) & 2 Nos C.I. double seal medium duty covers each of 600 x 600 mm size including excavation, backfilling & disposal of surplus earth complete as per standard design.(Note : Cost shall include dewatering & water proofing of chambers as directed at site).Grease Trap (Size 1500 x 750 x 1200 mm lequid depth). |
| 346 | SEPTIC TANK :- Providing, constructing and completing septic tank of required capacity and dimensions as per approved drawings, including excavation, PCC bed, RCC., internal partition/baffle walls, cement plastering and waterproofing, RCC cover slab, manhole covers, inlet and outlet connections, ventilation pipe, necessary fittings, testing, curing, backfilling and disposal of surplus earth, complete in all respects. as per the strc. design dwgs.( Size:- 15 mtr x 5mtr x 1.50 liq. depth ) |
| 347 | APPROVAL WASTE WATER DRAIN CONNECTION FROM LOCAL AUTHORITYGetting of waste water drain connection of nearest drain point from Approval from local drainage & water authority with all other charges and documentations for getting No Objection Certificate. |
| 348 | Cobsideration.Boring/drillingborewellofrequireddiaforcasing/strainerpipe,bysuitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 50 metre depth below ground level. All types of soil 400 mm dia |
| 349 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia |
| 350 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 351 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer- in-charge |
| 352 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. |
| 353 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer- in-charge. |
| 354 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. |
| 355 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement |
| 356 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia |
| 357 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm dia |
| 358 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of 200 mm dia |
| 359 | FIRE FIGHTING PUMPS:- Supply, installation, testing & commissioning of electric driven Hydrant & Sprinkler Pump suitable for automatic operation consisting of the following:Horizontal end suction centrifugal pump complete with mechanical seal and including necessary arrangement for testing of pump Squirrel cage induction motor suitable for 415 V, 50 Hz, AC supply of suitable rating for the above pump with synchronous speed of 2900 RPM T.E.F.C. type and conforming to IP:55 and flexible coupling and coupling guard with the pump. Common bed plate of fabricated mild steel channel or cast iron type. Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers as required. Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers as required. The pump shall be of the following specifications:Discharge-2280 lpm,Head - 88 mtr No. of stage preferred - Single / Double Speed RPM - 2900 Material of construction a) Impeller - Bronze b) Casing - C.I. c) Shaft & Shaft Sleeve - SS-410 d) Bearing - Grease Lubicated e) Seal & Make - Mechanical Type of pump - End suction HP :- 80HP ( 60KW.) ( Make :- KBL / M & P / GROUNDFOS / KSB.) |
| 360 | Supply, installation, testing & commissioning of electric driven Jockey Pump suitable for automatic operation consisting of the following: Horizontally mounted centrifugal end suction pump complete with mechanical seal and including necessary arrangement for testing of pump.Squirrel cage induction motor suitable for 4440 V, 50 Hz, AC supply of suitable rating for the above pump with synchronous speed of 2900 RPM T.E.F.C. type and conforming to IP:55 and flexible coupling and coupling guard with the pump.Common bed plate of fabricated mild steel channel or cast iron type.Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers as required.The pump shall be of the following specifications:Discharge - 180 lpm Head - 88 m No. of stage preferred - Multistage Speed RPM - 2900 Mover - Electric Motor Driven Material of construction a) Impeller - Bronze b) Casing - C.I. c) Shaft & Shaft Sleeve - SS-410 d) Bearing - Grease Lubicated e) Seal & Make - Mechanical Type of pump - End suction HP:- 7.0 HP ( 5 KW.) ( Make :- KBL / M & P / GROUNDFOS / KSB.) |
| 361 | Supply, installation, testing & commissioning of diesel engine Hydrant Pump suitable for automatic operation consisting of the following: Horizontal split casing centrifugal pump complete with mechanical seal and including necessary arrangement for testing of pump Water cooled Diesel Engine developing suitable BHP at 1500 RPM for the Pump, common bed plate for mounting of engine and pump, RCC foundation and vibration damping arrangement by Cushy Foot and engine panel provided by engine manufacturer, connection to Engine Starting Panel as per item (4), sealed maintenance free batteries of 24 V, 88 AH. Rate shall include Exhaust pipe of required length with asbestos lagging, muffler, day oil tank of 400 lts with first charge and manual oil pump set.Flexible coupling and coupling guard with the Pump,Common bed plate of fabricated mild steel channel or cast iron type.Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers as required. Engine panel Sealed maintenance free batteries of 24 V, 88 AH --2 Nos. (1 working + 1 standby)Exhaust pipe of required length with asbestos lagging, muffler Day oil tank G.I.-pipe Metal) of 400 lts with first charge and manual oil pump set and necessary piping and structural work to place tank at upper level from pump in pump room,Discharge -2280 lpm, Head - 88 m No. of stage preferred - Single / Double Speed RPM - 1450 Mover - Diesel engine driven Material of construction a) Impeller - Bronze b) Casing - C.I. c) Shaft & Shaft Sleeve - SS-410 d) Bearing - Grease Lubicated e) Seal & Make - Mechanical Type of pump - END SUCTION ( Make :- KBL / M & P / GROUNDFOS / KSB.) |
| 362 | Supply, installation, testing & commissioning of electric driven automatic fire booster Pump suitable for automatic operation consisting of the following: Horizontal end suction centrifugal pump complete with mechanical seal and including necessary arrangement for testing of pump. Squirrel cage induction motor suitable for 415 V, 50 Hz, AC supply of suitable rating for the above pump with synchronous speed of 2900 RPM T.E.F.C. type and conforming to IP:55 and flexible coupling and coupling guard with the pump. Common bed plate of fabricated mild steel channel or cast iron type. Suitable reinforced cement concrete pump foundation including cushy foot mounting, foundation bolts, washers as required. The pump shall be of the following specifications: Discharge-450 lpm, Head - 35 m No. of stage preferred - Single / Double Speed RPM - 2900 Material of construction a) Impeller - Bronze b) Casing- C.I. c) Shaft & Shaft Sleeve - SS-410 d) Bearing - Grease Lubicated e) Seal & Make - Mechanical ,Type of pump - End suction f) H.P.- 7 HP ( 5 KW.) ( Make :- KBL / M & P / GROUNDFOS / KSB.) |
| 363 | Providing and fixing air vessel for fire pumps as per following specifications: Diameter - 250mm, Shell thickness - 8mm, Dish ends - 10mm, Height - 1200mm Finishing - Two coats of Red enamel paint of first grade over one coat of primer externally & two coats of epoxy coating inside Material of Construction - M.S. Test Pressure - 15 Kg./sq.cm., drain arrangmenet with 25mm dia. dia gun metal wheel valve with required accessories etc. comp.( Make:- NewAge/ SBJ/ Sukan/ Winco/ ) |
| 364 | Fire Fighting Panel :- Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : Including feeders earthing and paint shade as per Fire norms and as per specifications.out going motor feeders to have start/stop on / off /trip indication and current in all the phases. All out going terminals brought to cable alleys. This panel should be painted in Red shade as per local Fire Officer's norms, if any. INCOMING250A, 50kA 4 Pole MCCB, Ics=100% Icu ratingDigital Voltmeter 0-500V with selector switchDigital Ammeter (0-250 A) with selector swtich & CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lampsSet of Copper Bus Bar 300A ( Make:- L & T, Siemens, Schinder, ABB) Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual modeIndicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indicationBattery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC AmmeterAll standard relays and accessories for automatic operation of diesel engineSystem ControllerDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification ( Make:- L & T, Siemens, Schinder, ABB) |
| 365 | Providing and laying the PVC insulated & sheathed FRLS Armoured cables of 1.1 K.V. Aluminium Conductor 3 core x 70 sq.mm ( Make:- KEW /FINOLEX/ POLYCAB ) |
| 366 | Providing and laying the PVC insulated & sheathed FRLS Armoured cables of 1.1 K.V. Aluminium Conductor 3 core x 10 sq.mm (cable from pump room to terrace for booster pump) |
| 367 | Providing and laying the PVC insulated & sheathed FRLS Armoured cables of 1.1 K.V. Aluminium Conductor 3 core x 16 sq.mm (cable for jockey pump)( Make:- KEW /FINOLEX/ POLYCAB ) |
| 368 | Providing and fixing in position cable end termination glands for above mentioned cables 3 core x 70 sq.mm ( Make:- JINDAL/HUMMEL/ ATEX ) |
| 369 | Providing and fixing in position cable end termination glands for above mentioned cables 3 core x 10 sq.mm (cable from Booster Pump to terrace Remort Panel )( Make:- JINDAL/HUMMEL/ ATEX ) |
| 370 | Providing and fixing in position cable end termination glands for above mentioned cables 3 core x 16 sq.mm (cable for jockey pump)( Make:- JINDAL/HUMMEL/ ATEX ) |
| 371 | Providing, installation, testing, & commissioning of Remote Panel for fire fighting terrace pump with push buttons for manual operation (the remote panel shall be located at ground level) all complete.( Make:-L & T/ Siemens/ Schinder/ABB) |
| 372 | Supplying, laying and connecting of following size 1.1 kV grade copper conductor armoured control cable on wall or on existing cable tray with clamping, dressing or drawn in existing ducts all as required (For remote panel for fire fighting terrace pump). 3 core x 6 sq.mm(Make:- KEW /FINOLEX/ POLYCAB ) |
| 373 | Providing, installation, testing, & commissioning of pressure switches for Hydrant, Sprinkler, Standby and Jockey pump including necessary wiring upto control panel & other materials.. ( Make:- Indfoss , Switcher, donfos ) |
| 374 | Providing and fixing fire retardent / extinguishing electrical insulated synthetic mat of 5mm thick ±10% conforming to latest BIS doc no.-ET-02(5440) meeting requirements of IS 3043 / IS 5216 (Part I, II & III), IS 8437 & IEC 479 suitable for all voltages not exceeding 3.3 KV AC supply and having minimum width of 1000mm ± 20mm and including supply of required quantity of adhsive / compound and fixing the same at site as per site requirement.. ( Make:- Vardhman/ Armacell/Vidyut ) |
| 375 | Fabricating and installing following size of perforated G.I.-pipe cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders including painting, etc., as required. 150mm width x 50mm depth x 1.6 mm thickness.. (Make:- Elcon/ Aeron/ Sharda/ Super Steel) |
| 376 | Providing & fixing 25 mm x 5 mm G.I.-pipe Strip in on surface or in recess for connections etc as required.(Make:- Elcon/ Aeron/ Sharda/ Super Steel) |
| 377 | Providing & fixing 25 mm x 5 mm G.I.-pipe Strip in 40 mm dia GI pipe from earth electrode as required.(Make:- Elcon/ Aeron/ Sharda/ Super Steel) |
| 378 | SUCTION AND DELIVERY PIPES AND VALVES FOR FIRE FIGHTING PUMPS:- Providing and fixing G.I.-pipe -Class- B Medium Duty suction & delivery headers / pipes for fire fighting pumps (IS. 1239 heavy duty) including all fittings like couplings, bends, elbows, offsets, blind flanges, plugs, tees, flanges (flanges as per table E), etc. threaded or welded (all type) joints as per detailed specfications as required, cutting holes and chases in brick or RCC walls or floors and making good complete alongwith painting G.I.-pipe pipe with coat of Red Oxide primer and two or more coats of synthetic enamel paint of approved colour and quality to give an even shade including surface preparation. 15 mm nominal bore(Make:- TATA/ JINDAL) |
| 379 | Providing and fixing G.I.-pipe -Class- B Medium Duty suction & delivery headers / pipes for fire fighting pumps (IS. 1239 heavy duty) including all fittings like couplings, bends, elbows, offsets, blind flanges, plugs, tees, flanges (flanges as per table E), etc. threaded or welded (all type) joints as per detailed specfications as required, cutting holes and chases in brick or RCC walls or floors and making good complete alongwith painting G.I.-pipe pipe with coat of Red Oxide primer and two or more coats of synthetic enamel paint of approved colour and quality to give an even shade including surface preparation. 25 mm nominal bore(Make:- TATA/ JINDAL) |
| 380 | Providing and fixing G.I.-pipe -Class- B Medium Duty suction & delivery headers / pipes for fire fighting pumps (IS. 1239 heavy duty) including all fittings like couplings, bends, elbows, offsets, blind flanges, plugs, tees, flanges (flanges as per table E), etc. threaded or welded (all type) joints as per detailed specfications as required, cutting holes and chases in brick or RCC walls or floors and making good complete alongwith painting G.I.-pipe pipe with coat of Red Oxide primer and two or more coats of synthetic enamel paint of approved colour and quality to give an even shade including surface preparation. 80 mm nominal bore (Make:- TATA/ JINDAL) |
| 381 | Providing and fixing G.I.-pipe -Class- B Medium Duty suction & delivery headers / pipes for fire fighting pumps (IS. 1239 heavy duty) including all fittings like couplings, bends, elbows, offsets, blind flanges, plugs, tees, flanges (flanges as per table E), etc. threaded or welded (all type) joints as per detailed specfications as required, cutting holes and chases in brick or RCC walls or floors and making good complete alongwith painting G.I.-pipe pipe with coat of Red Oxide primer and two or more coats of synthetic enamel paint of approved colour and quality to give an even shade including surface preparation. 100 mm nominal bore (Make:- TATA/ JINDAL) |
| 382 | Providing and fixing G.I.-pipe -Class- B Medium Duty suction & delivery headers / pipes for fire fighting pumps (IS. 1239 heavy duty) including all fittings like couplings, bends, elbows, offsets, blind flanges, plugs, tees, flanges (flanges as per table E), etc. threaded or welded (all type) joints as per detailed specfications as required, cutting holes and chases in brick or RCC walls or floors and making good complete alongwith painting G.I.-pipe pipe with coat of Red Oxide primer and two or more coats of synthetic enamel paint of approved colour and quality to give an even shade including surface preparation. 150 mm nominal bore (Make:- TATA/ JINDAL) |
| 383 | Providing and fixing M.S.-pipe -Class- C Heavy Duty suction & delivery headers / pipes for fire fighting pumps (IS. 1239/IS:3589 heavy duty) including all fittings like couplings, bends, elbows, offsets, blind flanges, plugs, tees, flanges (flanges as per table E), etc. threaded or welded (all type) joints as per detailed specfications as required, cutting holes and chases in brick or RCC walls or floors and making good complete alongwith painting M.S.-pipe pipe with coat of Red Oxide primer and two or more coats of synthetic enamel paint of approved colour and quality to give an even shade including surface preparation. 200 mm nominal bore (6.3 thick min.)(Make:- TATA/ JINDAL) |
| 384 | Providing and fixing cast iron wafer type Butterfly valve of the following size complete with bolts, nuts, washers and neoprene gaskets as per specifications. 80 mm nominal bore (Make:- Audco, Kartaar, Zoloto) |
| 385 | Providing and fixing cast iron wafer type Butterfly valve of the following size complete with bolts, nuts, washers and neoprene gaskets as per specifications. 100 mm nominal bore (Make:- Audco, Kartaar, Zoloto) |
| 386 | Providing and fixing cast iron wafer type Butterfly valve of the following size complete with bolts, nuts, washers and neoprene gaskets as per specifications. 150 mm nominal bore (Make:- Audco, Kartaar, Zoloto) |
| 387 | Providing and fixing cast iron wafer type Butterfly valve of the following size complete with bolts, nuts, washers and neoprene gaskets as per specifications. 200 mm nominal bore (Make:- Audco, Kartaar, Zoloto) |
| 388 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 100 mm nominal bore |
| 389 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 80 mm nominal bore (Make:- Audco, Kartaar, Zoloto) |
| 390 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 150 mm nominal bore (Make:- Audco, Kartaar, Zoloto) |
| 391 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 200 mm nominal bore (Make:- Audco, Kartaar, Zoloto) |
| 392 | Providing and fixing reinforced Neoprene flexible pipe connectors with all accessories on all pumps delivery.Suitable for 20 Kg/cm2 80mm ( Make:- Elaflex, V.H. Polymer, Corirubber ) |
| 393 | Providing and fixing reinforced Neoprene flexible pipe connectors with all accessories on all pumps delivery.Suitable for 20 Kg/cm2 150mm ( Make:- Elaflex, V.H. Polymer, Corirubber ) |
| 394 | Providing and fixing of nickel plated brass / nonferrous alloy fullyway ball valve (minimum working pressure of 20 bar ) with operating handle of approved make. 25 mm nominal bore (Make:- Audco, Kartaar, Zoloto) |
| 395 | Providing and fixing of nickel plated brass / nonferrous alloy fullyway ball valve (minimum working pressure of 20 bar ) with operating handle of approved make.15 mm nominal bore (Make:- Audco, Kartaar, Zoloto) |
| 396 | FIRE HYDRANT SYSTEM(External & Internal) (All Fire Fighting Hardware Should be ISI Mark) :-Providing, fixing, jointing and testing heavy quality 'B' class Medium duty G.I. Pipe conforming to IS 3589/IS 1239 for pipes upto 150 mm dia. including forged threaded/socked(weldable) i.e. tees, bends, elbows, unions, reducers, draining arrangement, flange joints, rubber insertion, nuts & bolts etc. as required including fixing of pipework on walls, slabs etc. with M. S. supports (duly painted), adjustible hangers. Note: Joints for pipes and fitttings upto 50 mm diameter shall be threaded joints using Teflon Tape or equivalent bonding tape on the threads. Joints for pipe and fittings above 50 mm diameter shall be welded joints.Above ground pipe-with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation. :- 25 mm dia (Make:- TATA/ JINDAL) |
| 397 | Providing, fixing, jointing and testing heavy quality 'B' class Medium duty G.I. Pipe conforming to IS 3589/IS 1239 for pipes upto 150 mm dia. including forged threaded/socked(weldable) i.e. tees, bends, elbows, unions, reducers, draining arrangement, flange joints, rubber insertion, nuts & bolts etc. as required including fixing of pipework on walls, slabs etc. with M. S. supports (duly painted), adjustible hangers. Note: Joints for pipes and fitttings upto 50 mm diameter shall be threaded joints using Teflon Tape or equivalent bonding tape on the threads. Joints for pipe and fittings above 50 mm diameter shall be welded joints.Above ground pipe -with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation.:- 80 mm dia (Make:- TATA/ JINDAL) |
| 398 | Providing, fixing, jointing and testing heavy quality 'B' class Medium duty G.I. Pipe conforming to IS 3589/IS 1239 for pipes upto 150 mm dia. including forged threaded/socked(weldable) i.e. tees, bends, elbows, unions, reducers, draining arrangement, flange joints, rubber insertion, nuts & bolts etc. as required including fixing of pipework on walls, slabs etc. with M. S. supports (duly painted), adjustible hangers. Note: Joints for pipes and fitttings upto 50 mm diameter shall be threaded joints using Teflon Tape or equivalent bonding tape on the threads. Joints for pipe and fittings above 50 mm diameter shall be welded joints.Above ground pipe -with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation.:- 100 mm dia (Make:- TATA/ JINDAL) |
| 399 | Providing, fixing, jointing and testing heavy quality 'B' class Medium duty G.I. Pipe conforming to IS 3589/IS 1239 for pipes upto 150 mm dia. including forged threaded/socked(weldable) i.e. tees, bends, elbows, unions, reducers, draining arrangement, flange joints, rubber insertion, nuts & bolts etc. as required including fixing of pipework on walls, slabs etc. with M. S. supports (duly painted), adjustible hangers. Note: Joints for pipes and fitttings upto 50 mm diameter shall be threaded joints using Teflon Tape or equivalent bonding tape on the threads. Joints for pipe and fittings above 50 mm diameter shall be welded joints.Above ground pipe-with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation. :- 150 mm dia (Make:- TATA/ JINDAL) |
| 400 | Providing and laying of 'B' class Medium duty G.I. Pipe conforming to IS 3589/IS 1239 including all GI/MS fittings like couplings, bends, elbows, offsets, blind flanges, plugs, tees, flanges (flanges as per table E), etc. threaded or welded (all type ) joints as per detailed specfications as required, cutting holes and chases in brick or RCC walls or floors and making good complete with one coat of 4 mm thick 'PYPKOTE' or COATEK anti rust pipe protection including approved primer & surface preparation of pipes as per manufacturers specifications and lap of 25 mm to make an impermeable layer on G.I. Pipes in trenches or underground pipes below soil all complete.Under ground pipe-with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation. 80 mm dia(UNDERGROUND) (Make:- TATA/ JINDAL) |
| 401 | Providing and laying of 'B' class Medium duty G.I. Pipe conforming to IS 3589/IS 1239 including all GI/MS fittings like couplings, bends, elbows, offsets, blind flanges, plugs, tees, flanges (flanges as per table E), etc. threaded or welded (all type ) joints as per detailed specfications as required, cutting holes and chases in brick or RCC walls or floors and making good complete with one coat of 4 mm thick 'PYPKOTE' or COATEK anti rust pipe protection including approved primer & surface preparation of pipes as per manufacturers specifications and lap of 25 mm to make an impermeable layer on G.I. Pipes in trenches or underground pipes below soil all complete.Under ground pipe-with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation. 100 mm dia(UNDERGROUND) (Make:- TATA/ JINDAL) |
| 402 | Providing and laying of 'B' class Medium duty G.I. Pipe conforming to IS 3589/IS 1239 including all GI/MS fittings like couplings, bends, elbows, offsets, blind flanges, plugs, tees, flanges (flanges as per table E), etc. threaded or welded (all type ) joints as per detailed specfications as required, cutting holes and chases in brick or RCC walls or floors and making good complete with one coat of 4 mm thick 'PYPKOTE' or COATEK anti rust pipe protection including approved primer & surface preparation of pipes as per manufacturers specifications and lap of 25 mm to make an impermeable layer on G.I. Pipes in trenches or underground pipes below soil all complete.Under ground pipe :- 150 mm dia(UNDERGROUND)with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation. (Make:- TATA/ JINDAL) |
| 403 | Providing and fixing S.S landing valve conforming to IS -5290 with 63 mm dia instantaneous female coupling on the outlet with S.S. orifice flange 6 mm thick as required to maintain 3.5 Kg/sq.cm., blank cap and chain, necessary companion flanges ( as per table \\"E\\") nuts, bolts, washer and gasket complete as per specification. (ISI marked) Single outlet ( Make:- NEWAGE / SBJ / SUKAN/ WINCO / PRIYANKA ) |
| 404 | Providing and fixing first aid fire hose reel drum wall mounting, swinging type fitted with 20 mm dia 30.0 m long high pressure hose to I.S. 5132 with 25 mm outlet gunmetal nozzle with shut off valve (I.S. 884-1969). Name of Manufacturer should be embossed on the drum. ( Make:- NEWAGE / SBJ / SUKAN/ WINCO / PRIYANKA ) |
| 405 | Providing and fixing 63 mm dia 15m long EPDM lined fabric lined hose including SS male and female instantaneous type coupling approved by fire authority, machine wound with copper wire complete in all respects.Hose shall conform to IS 636 TypeII and coupling to IS 903 -1975 (ISI marked) ( Make:- NEWAGE / SBJ / SUKAN/ WINCO / PRIYANKA ) |
| 406 | Providing and fixing standard short size SS branch pipe with gunmetal nozzle 20 mm dia outlet with standard instantaneoustype 63 mm dia coupling. (conform to IS-903). ( Make:- NEWAGE / SBJ / SUKAN/ WINCO / PRIYANKA ) |
| 407 | Providing and fixing standard fireman's axe ( tested for 20000 Volts) with heavy insulated rubber handle.( ISI marked)( Make:- NEWAGE / SBJ / SUKAN/ WINCO / PRIYANKA ) |
| 408 | Providing and fixing gunmetal single acting air release valve with screwed inlet 25 mm dia. . ( Make:- Audco , Leader , Sant, & Zoloto ) |
| 409 | Providing and fixing brass ball valve (full bore type) with plastic coated lever and screwed female ends tested to 20 Kg/ cm2 of approved quality as specified.20mm . ( Make:- Audco , Leader , Sant, & Zoloto ) |
| 410 | Providing and fixing brass ball valve (full bore type) with plastic coated lever and screwed female ends tested to 20 Kg/ cm2 of approved quality as specified. 25 mm dia . ( Make:- Audco , Leader , Sant, & Zoloto ) |
| 411 | Providing and fixing door with frame for all internal fire hydrants fabricated from 16 SWG Alumunim of size 750 x 1200 x2100 mm double door including 2 nos allen key lock for locking along with padlock arrangement & fully glazed with 4 mm thick float glass approved by local Fire Authority, stove enameled fire red finish with \\" fire hose' written on front suitable to house 15 mm long four length of canvas hose with couplings,one no of branch pipe, one fire mans axe and two numbers of portable extinguishers, first aid fire hose and supports for hoses, branch pipes, Axe and hose reel. as per approved design including necessary fixing arrangement for hoses & axe and branch pipe.) FOR INTERNAL.( Make:- NEWAGE / SBJ / SUKAN/ WINCO / PRIYANKA ) |
| 412 | Providing and fixing dial type pressure gauge with isolation cock and chrome coated copper pipe at hydrant station. Dial diameter 100 mm calebration 0-15 kg/ sq.cm.. ( Make:- H GURU / FIEBG/ BELL / WARREE ) |
| 413 | Providing and fixing cast iron wafer type Butterfly valve -PN-1.6-of the following size complete with bolts, nuts, washers and neoprene gaskets as per specifications. 80 mm dia (Make:- Audco, Kartaar, Zoloto) |
| 414 | Providing and fixing cast iron wafer type Butterfly valve-pn-1.6- of the following size complete with bolts, nuts, washers and neoprene gaskets as per specifications. 150 mm dia (Make:- Audco, Kartaar, Zoloto) |
| 415 | Providing and fixing cast iron dual plate wafer type non return valves. 150 mm dia (Make:- Audco, Kartaar, Zoloto) |
| 416 | Providing and fixing gunmetal fire brigade inlet head as per IS:904 Specification tested for 20 Kg/cm2 with 63 mm dia instantaneous type inlet and 150mm dia. flanged outlet with built-in check valve for fire brigade connection to under ground tanks and fire risers including campanion flanges as pertable \\" E\\" including nuts, bolts & washers etc. Four way ( Make:- NEWAGE / SBJ / SUKAN/ WINCO / PRIYANKA ) |
| 417 | Providing and fixing gunmetal fire brigade inlet head as per IS:904 Specification tested for 20 Kg/cm2 with 63 mm dia instantaneous type inlet and 150mm dia. flanged outlet with built-in check valve for fire brigade connection to under ground tanks and fire risers including campanion flanges as pertable \\" E\\" including nuts, bolts & washers etc. Two way ( Make:- NEWAGE / SBJ / SUKAN/ WINCO / PRIYANKA ) |
| 418 | Providing and fixing suction coupling for fire brigade drawl of water from tank with 150 mm dia GI (Medium) pipe and foot valve .( Make:- NEWAGE / SBJ / SUKAN/ WINCO / PRIYANKA ) |
| 419 | Providing, fixing ,testing and commissioning external (yard) hydrant \\"STAND-POST\\" type conforming to IS:908-1975 and comprising of stand post for single outlet of hot diped class ' C' G.I.-pipe Pipe of 100 mm dia at the with instantaneous spring lock type Stainless steel female coupling of 63 mm dia for connecting to hose pipe, single headed SS valves conforming to type A of IS: 5290-1977, GI tee tapping from underground mains, flange riser and any other accessories etc. as per specification complete as required. ( Make:- NEWAGE / SBJ / SUKAN/ WINCO / PRIYANKA ) |
| 420 | Providing and fixing fire hose cabinet fabricated from 16 gauge M.S.sheet with locking arrangement and hanging arrangement for accessories painted \\"Fire Red\\" with Stove enameled paint \\"Fire Hose\\" written on front including suitable supports to place 900 mm above ground level properly anchored, approximately size 800 X 600 X 250 mm deep (to house two lengths of canvas hose with couplings, branch pipe with nozzle for external hydrants) FOR EXTERNAL. ( Make:- NEWAGE / SBJ / SUKAN/ WINCO / PRIYANKA ) |
| 421 | SPRINKLER SYSTEM :- Providing and fixing 'B' class Medium duty G.I. Pipe conforming to IS 3589/IS 1239 complete with GI / MS fittings like couplings, bends, elbows, tees, offsets,reducers, flanges as per table 'E' etc. including cutting and making good the walls complete.Pipes upto 50 mm dia threaded joint with holdtite, 65 mm dia and above should be welded joint (all type).with one coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour to give an even shade including surface preparations. :- 25 mm dia (Make:- TATA/ JINDAL) |
| 422 | Providing and fixing 'B' class Medium duty G.I. Pipe conforming to IS 3589/IS 1239 complete with GI / MS fittings like couplings, bends, elbows, tees, offsets,reducers, flanges as per table 'E' etc. including cutting and making good the walls complete.Pipes upto 50 mm dia threaded joint with holdtite, 65 mm dia and above should be welded joint (all type).with one coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour to give an even shade including surface preparations. :-32 mm dia (Make:- TATA/ JINDAL) |
| 423 | Providing and fixing 'B' class Medium duty G.I. Pipe conforming to IS 3589/IS 1239 complete with GI / MS fittings like couplings, bends, elbows, tees, offsets,reducers, flanges as per table 'E' etc. including cutting and making good the walls complete.Pipes upto 50 mm dia threaded joint with holdtite, 65 mm dia and above should be welded joint (all type).with one coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour to give an even shade including surface preparations. :-40 mm dia (Make:- TATA/ JINDAL) |
| 424 | Providing and fixing 'B' class Medium duty G.I. Pipe conforming to IS 3589/IS 1239 complete with GI / MS fittings like couplings, bends, elbows, tees, offsets,reducers, flanges as per table 'E' etc. including cutting and making good the walls complete.Pipes upto 50 mm dia threaded joint with holdtite, 65 mm dia and above should be welded joint (all type).with one coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour to give an even shade including surface preparations. :-50 mm dia (Make:- TATA/ JINDAL) |
| 425 | Providing and fixing 'B' class Medium duty G.I. Pipe conforming to IS 3589/IS 1239 complete with GI / MS fittings like couplings, bends, elbows, tees, offsets,reducers, flanges as per table 'E' etc. including cutting and making good the walls complete.Pipes upto 50 mm dia threaded joint with holdtite, 65 mm dia and above should be welded joint (all type).with one coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour to give an even shade including surface preparations. :-65 mm dia (Make:- TATA/ JINDAL) |
| 426 | Providing and fixing 'B' class Medium duty G.I. Pipe conforming to IS 3589/IS 1239 complete with GI / MS fittings like couplings, bends, elbows, tees, offsets,reducers, flanges as per table 'E' etc. including cutting and making good the walls complete.Pipes upto 50 mm dia threaded joint with holdtite, 65 mm dia and above should be welded joint (all type).with one coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour to give an even shade including surface preparations. :-80 mm dia (Make:- TATA/ JINDAL) |
| 427 | Providing and fixing 'B' class Medium duty G.I. Pipe conforming to IS 3589/IS 1239 complete with GI / MS fittings like couplings, bends, elbows, tees, offsets,reducers, flanges as per table 'E' etc. including cutting and making good the walls complete.Pipes upto 50 mm dia threaded joint with holdtite, 65 mm dia and above should be welded joint (all type).with one coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour to give an even shade including surface preparations. :-100 mm dia (Make:- TATA/ JINDAL) |
| 428 | Providing and fixing 'B' class Medium duty G.I. Pipe conforming to IS 3589/IS 1239 complete with GI / MS fittings like couplings, bends, elbows, tees, offsets,reducers, flanges as per table 'E' etc. including cutting and making good the walls complete.Pipes upto 50 mm dia threaded joint with holdtite, 65 mm dia and above should be welded joint (all type).with one coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour to give an even shade including surface preparations. :-150 mm dia (Make:- TATA/ JINDAL) |
| 429 | Providing and fixing 15 mm gunmetal sprinkler head with quartz bulb and set to operate at specified temperature pendent/ upright/ side wall as per instruction and fixing with loctite. Pendent Type 68 C ( Make :- H.D. FIRE / TYCO/VIKING) |
| 430 | Providing and fixing 15 mm gunmetal sprinkler head with quartz bulb and set to operate at specified temperature pendent/ upright/ side wall as per instruction and fixing with loctite. Side Wall Type 68 C ( Make :- H.D. FIRE / TYCO/VIKING) |
| 431 | Providing and fixing 15 mm gunmetal sprinkler head with quartz bulb and set to operate at specified temperature pendent/ upright/ side wall as per instruction and fixing with loctite. Upright Type 68 C ( Make :- H.D. FIRE / TYCO/VIKING) |
| 432 | Rossete Plate:-Providing, installation, testing & commissioning ofadjustable rosette plate for 15mm dia in white finish ULListed or FM approved complete as required. ( Make :- H.D. FIRE / TYCO/VIKING) |
| 433 | Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.1200mm ( Make:- SBJ/ Newage/ Pneucons) |
| 434 | Providing & fixing 25mm dia gunmetal inspecting & testing assembly with ball valve(3 nos.), gunmetal sight glass, by pass valve & connected to drain line. ( Make:- Audco , Leader , Sant, & Zoloto ) |
| 435 | Providing and fixing brass ball valve full bore type with plastic coated lever approved quality, tested to 20 Kg.cm.sq. 40 mm dia ( Make:- Audco , Leader , Sant, & Zoloto ) |
| 436 | Providing and fixing brass ball valve full bore type with plastic coated lever approved quality, tested to 20 Kg.cm.sq. 50 mm dia ( Make:- Audco , Leader , Sant, & Zoloto ) |
| 437 | Providing and fixing cast iron wafer type Butterfly valve-PN-1.6- of the following size complete with bolts, nuts, washers and neoprene gaskets as per specifications. :- 100 mm nominal bore ( Make:- Audco , Leader , Sant, & Zoloto ) |
| 438 | Providing and fixing cast iron wafer type Butterfly valve -PN-1.6-of the following size complete with bolts, nuts, washers and neoprene gaskets as per specifications. :- 65 mm nominal bore ( Make:- Audco , Leader , Sant, & Zoloto ) |
| 439 | Providing and fixing electricaly operated flow indicating switches model System Sensor in sprinkler branch line on each floor with necessary junction box installed in accessible place (Wiring from switches to panel and stair case pressurisation not included) :- 100 mm dia ( Make:- DANFOSS/ Honeywell /FORBES MARSHALL/SWITZER ) |
| 440 | Providing and fixing dial type pressure gauge with isolation cock and copper pipe on main header Dial diameter 100 mm celebration 0-15 / sq. cm. ( Make:- H GURU / FIEBG/ BELL / WARREE) |
| 441 | Providing and fixing 25 mm dia single acting air release valve with screwed inlet..(Make:- Audco, Kartaar, Zoloto) |
| 442 | Providing and fixing cast iron dual plate wafer type non return valves. :- 150 mm dia .(Make:- Audco, Kartaar, Zoloto) |
| 443 | Providing and fixing cast iron dual plate wafer type non return valves.:- 100 mm dia .(Make:- Audco, Kartaar, Zoloto) |
| 444 | Providing, Installation, testing and commissioning of Control Valve inclusive of: - 150 mm dia butterfly Valve,Alarm Valve with Water Motor Gong, Pressure gauge and other miscellaneous Valves and fittings as required. ( Make:- NEWAGE / SBJ / SUKAN/ WINCO / HD FIRE) |
| 445 | Fire Resistant Door Double Leaf Hinge Type (2 Hour Fire Rated) 1.00 mm thick GI Sheet cladded 40mm thick shutter complete with GI frame (Single Ribet – Frame Profile 100 x 57mm) made from 1.20mm thick GI Sheet & Fixing arrangements AS PER BS 476 PART- 20 & 22 & IS: 3614 Part - II for Integrity, Stability.Door Size: 2000mm (W) x 2100mm (H) Including below Accessories S.S. Ball Bearing Hinges- 6 Nos Vision Panel with Fire Glass of Size: 200 x 300mm - 2 Nos Heavy Duty Door Closer - 2 Nos Heavy Duty Door Closer - 2 Nos Panic Exit Device for Double Leaf Door - 1 No. External Trim Bar (Panic Latch) - 1 No. ( JC-Fire Door/ Metaflex Doors India PVT ltd/ Navair / Promat) |
| 446 | HAND APPLIANCES :- Providing and fixing ABC type fire extinguishers consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. Capacity 6.0 kg. I.S.I. Marked.( Make:- KANEX/ CEASE FIRE / SAFEX ) |
| 447 | Providing and fixing Trolley type foam fire extinguishers cap. 50 liters. 50 litres capacity ( Make:- KANEX/ CEASE FIRE / SAFEX ) |
| 448 | Providing and fixing in position Co2 gas type fire extinguishers of 4.5 kg. capacity each.( Make:- KANEX/ CEASE FIRE / SAFEX ) |
| 449 | Providing and fixing Trolley type Co2 gas fire extinguishers cap. 9 liters will be provided for transformer area.( Make:- KANEX/ CEASE FIRE / SAFEX ) |
| 450 | Providing and keeping in position standard sand buckets filled with clean sand and painted red from outside at various places.( Make:- KANEX/ CEASE FIRE / SAFEX ) |
| 451 | Providian’s Escape Sigane:- Photoluminescent rigid plastic, 2mm thickness, printed on high quality glass paint with UV resistance, 5 year warranty, material used-non radioactive, non-phophorous, non toxic and lead free. Available in different types & sizes, time after removing the light source (in minutes):- 60 minutes, luminescent intensity(milicandelas*per square meter-mcd/sqm):30 mcd/sqm. Luminescent intensity greater than 0.32 mcd/sqm, period of light decay* (in minutes) :3100 (1) “Fire Exits” ( Size 365 x 119 x 84 mm or nearest )(Make : Honeywell, Cease Fire, Prolite , Glowster ) |
| 452 | (2)Fire exit signs of standard size ( Size 450 x 200 x 84 mm or nearest ) (photoluminous type.(glowing in dark type)Providing and fixing portable fire extinguishers of approved make ISI marked of following Capacity at the places shown on Drawing & mentioned in CFO letter .(Make : Honeywell, Cease Fire, Prolite , Glowster ) |
| 453 | Providing, fixing, testing and commissioning of below Auto Glow Signages. In Case of Fire do not use Lift ,Use Staircase 8\\"x 8\\" (Make : Honeywell, Cease Fire, Prolite , Glowster ) |
| 454 | ADDITIONAL WORK:- Core Cutting in RCC wall, beam, columns and roof as required locations of required size & depth and repairing , making it goods complete . Size 40mm to 80mm dia ( avarge depth 200) |
| 455 | Core Cutting in RCC wall, beam, columns and roof as required locations of required size & depth and repairing , making it goods complete :- Size 100mm to 200mm dia ( avarge depth 200) |
| 456 | Supply & fixing of testing and commissioning of stainless steel Y-strainer fabricated out of 1.6mm thickness steel, grade 304, sheet with 3mm dia holes with stainless steel flange.. 100mm dia y strainer in main suction header ( Make:- Audco , Leader , Sant, & Zoloto ) |
| 457 | Supply & fixing of testing and commissioning of stainless steel Y-strainer fabricated out of 1.6mm thickness steel, grade 304, sheet with 3mm dia holes with stainless steel flange. 150mm dia. Size ( Make:- Audco , Leader , Sant, & Zoloto ) |
| 458 | Supply & fixing of testing and commissioning of Orifice plate made out of 6mm thick stainless steel Grade-304, with orifice of required size to be fitted between flange & landing valve of external & internal hydrants to reduce pressure at the outlet to the level of 3.5 kg. cm2 complete as required. (WIKA/ Armstrong /GENERAL/ EUERA / ) |
| 459 | Earthing with G.I.-pipe earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 460 | Earthing with G.I.-pipe earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 461 | Costing for Liasion work with authority and obtaining Pre & Final NOC and all relevant applicable approvals including required drawing work. |
| 462 | Point WiringPoint wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length , in below type of pipe erected with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete. Cat. III |
| 463 | Point wiring for Tissino / Modular secondary light point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires, in below type of pipe to be erected complete with earth continuity and necessary connection with primary light with accessories erected on Metal / PVC / wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic sheet for open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed.Note:- Maximum up to 6 mtrs length, excess will be considered as Mains for Secondary Point(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete |
| 464 | Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in following type of pipe to be erected concealed in / flushed on wall / ceiling complete with 6A Tissino Type ISI marked accessories with earth continuity erected on Metal/PVC//Wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic sheet. with necessary Lamp holder/ceiling rose / H.D.Connector as directed.(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete |
| 465 | Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected with 6A Modular type switch and hum free EME step type electronic fan regulator mounted and accessories with earth continuity of following type erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed.(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete.Cat.III |
| 466 | Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate modules erected on / in wall / ceiling with following type accessories.Cat. III |
| 467 | Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories.[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db board(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete.Cat.III |
| 468 | Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories.[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board.(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete. Cat. III |
| 469 | Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories.[III] For 16A Plug and 16 amp switch with 2-4 sq.mm Cu. Wire with 2.5 sq.mm ( green) earthing wire from mcb d b board.(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete |
| 470 | Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (b) 25 mm |
| 471 | Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (c) 32 mm |
| 472 | Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (d) 40 mm |
| 473 | MAINS : ( not for Point wiring )providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size(A) with medium class Rigid PVC pipe and accessories(a) 2 wire 4 sq. mm |
| 474 | Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (A) With medium class Rigid PVC pipe and accessories(b) 2 wire 2.5 sq. mm |
| 475 | Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (A) With medium class Rigid PVC pipe and accessories(a) 2 wire 1.5 sq. mm |
| 476 | Distribution BoardSupply, Assembling, grouting, leveling Connecting & testing D.B .Distribution Board-VTPNProviding and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) - flush / surface mounted double door (IP54) fitted with insulated copper busbar, isolated neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986,IP-54 suitable for 63/100 AMP TPN MCCB + RCCB as incomer and three phase outgoing as per following .(The DBs should be used of same company of MCB to be used) 12 way outgoing |
| 477 | Providing and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) - flush / surface mounted double door (IP54) fitted with insulated copper busbar, isolated neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986,IP-54 suitable for 63/100 AMP TPN MCCB + RCCB as incomer and three phase outgoing as per following .(The DBs should be used of same company of MCB to be used) 4 way outgoing |
| 478 | Distribution Board-TPNProviding and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable forthree phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) sheet steel double door 16 way |
| 479 | Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable forthree phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) sheet steel double door 12 way |
| 480 | Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable forthree phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) sheet steel double door 8 way |
| 481 | Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable forthree phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) sheet steel double door 6 way |
| 482 | Distribution Board-SPNProviding and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for single phase incoming and horizontal single phase outgoingsheet steel double door (IP-43) 16 way |
| 483 | Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for single phase incoming and horizontal single phase outgoingsheet steel double door (IP-43) 12 way |
| 484 | Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for single phase incoming and horizontal single phase outgoingsheet steel double door (IP-43) 8 way |
| 485 | MCBproviding and erecting Miniature circuit breaker single pole 0.5A to 2A system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark .Cat.III |
| 486 | providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark. Cat.III |
| 487 | Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity (A) 6 to 32 Amp. Cat.III |
| 488 | Providing & erecting 415 V MCB three Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity (a) 6 to 32 Amp. Cat.III |
| 489 | providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed (i) 25 Amps.DP Cat.III |
| 490 | providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed(ii) 40Amps. DP Cat.III |
| 491 | providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed(iii) 63Amps. DP Cat.III |
| 492 | Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity (a) 6 to 32 Amp. Cat.III |
| 493 | Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity (b)40 Amp. Cat.III |
| 494 | Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity 63 A FP MCB. Cat.III |
| 495 | Providing & erecting approved make street light / wall mounting junction box compression moulded from SMC (thermoset plastic) vertical sliding cover having locking with square head stud loop in / loop out in built terminal suitable for four core cable, waterproof of I.P. 54 protected with clamp or bolt nut & earth bolt of following size.(A) 200mm x 127mm x 83 mm |
| 496 | Supplying & erecting 20 Amp 10 KA ‘C Curve’ single pole MCB with 20 Amp. Plug socket, company fabricated powder coated sheet steel enclosure erected as directed with connection. [A] Metal Clad Socket with metal clad topCat.III |
| 497 | Cable TrenchMaking trench in soft soil of suitable width of 90 cm deep for laying cable or locating the fault all over the run and back filling the same and making the surface as normal ground. |
| 498 | Covering of cable with second class bricks or cement tiles laid cover the cable crosswise & also on both sides with covering of 7. 5 Cm. layer of sand above & below cable (16 bricks per meter) |
| 499 | Construction of brick masonry pulling chamber 450 mm x 450 mm inside clear size and depth up to 0.6 meter with 350 mm thick masonry in cement mortar proportion 1:5,cement finish cement plaster in CM proportion of 15 mm thickness from inside with 150 mm thick PCC at bottom with top slab minimum 200 mm thickness in M20 grade with reinforcement. The rate shall be inclusive of providing and fixing frame and 450 mm dia cover of FRC for the Heavy Duty. Rate also inclusive of excavation and back filling & clearing the site by removing debris & Shifting of the debris & making site good As per the Instruction of the Engineer In charge complete in all respect. |
| 500 | Construction of brick masonry pulling chamber 600 mm x 600 mm inside clear size and depth up to 0.60 meter with 350 mm thick masonry in cement mortar proportion 1:5,cement finish cement plaster in CM proportion of 15 mm thickness from inside with 150 mm thick PCC at bottom with top slab minimum 200 mm thickness in M20 grade with reinforcement. The rate shall be inclusive of providing and fixing frame and 600 mm dia cover of FRC for the Heavy Duty. Rate also inclusive of excavation and back filling & clearing the site by removing debris & Shifting of the debris & making site good As per the Instruction of the Engineer In charge complete in all respect. |
| 501 | Construction of brick masonry pulling chamber 750 mm x 750 mm inside clear size and depth up to 0.75 meter with 350 mm thick masonry in cement mortar proportion 1:5,cement finish cement plaster in CM proportion of 15 mm thickness from inside with 150 mm thick PCC at bottom with top slab minimum 200 mm thickness in M20 grade with reinforcement. The rate shall be inclusive of providing and fixing frame and 750 mm dia cover of FRC for the Heavy Duty. Rate also inclusive of excavation and back filling & clearing the site by removing debris & Shifting of the debris & making site good As per the Instruction of the Engineer In charge complete in all respect. |
| 502 | Construction of brick masonry pulling chamber 1000 mm x 1000 mm inside clear size and depth up to 1.0 meter with 350 mm thick masonry in cement mortar proportion 1:5,cement finish cement plaster in CM proportion of 15 mm thickness from inside with 150 mm thick PCC at bottom with top slab minimum 200 mm thickness in M20 grade with reinforcement. The rate shall be inclusive of providing and fixing frame and 900 mm dia cover of FRC for the Heavy Duty. Rate also inclusive of excavation and back filling & clearing the site by removing debris & Shifting of the debris & making site good As per the Instruction of the Engineer In charge complete in all respect. |
| 503 | Cable TrayProviding and fixing approved make Ladder type cable tray. Made from M.S sheet. The cable tray should be bended as per IS 2062/1079 shall be fabricated of double bended channel section longitudinal members with single bended Channel section. Rungs of members welded to the base of the longitudinal members at 250 mm c/c spacing . as per IS and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge..(16) 900 X 100 X 2.0 mm Thick |
| 504 | Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The cable tray should be bended as per IS 2062/1079 shall be fabricated of double bended channel section longitudinal members with single bended Channel section. Rungs of members welded to the base of the longitudinal members at 250 mm c/c spacing . as per IS and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge..600 X 100 X 2 mm Thick |
| 505 | Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The cable tray should be bended as per IS 2062/1079 shall be fabricated of double bended channel section longitudinal members with single bended Channel section. Rungs of members welded to the base of the longitudinal members at 250 mm c/c spacing . as per IS and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge..400 X 100 X 2 mm Thick |
| 506 | Providing and fixing approved make Perforated C type cable tray. Made from sheet steel. The cable tray should be single or double bended as per required and as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erection with necessary support( included) as per Specification and as per instruction of engineer in charge..(2) 100 X 50 X 1.6 mm Thick |
| 507 | Providing and fixing approved make Perforated C type cable tray. Made from sheet steel. The cable tray should be single or double bended as per required and as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erection with necessary support( included) as per Specification and as per instruction of engineer in charge..(5) 300 X 50 X 2.0 mm Thick |
| 508 | Providing and fixing approved make Perforated C type cable tray. Made from sheet steel. The cable tray should be single or double bended as per required and as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erection with necessary support( included) as per Specification and as per instruction of engineer in charge..(6) 450 X 50 X 2.0 mm Thick |
| 509 | Providing and fixing approved make Perforated C type cable tray. Made from sheet steel. The cable tray should be single or double bended as per required and as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erection with necessary support( included) as per Specification and as per instruction of engineer in charge..(7) 600 X 50 X 2.0 mm Thick |
| 510 | FabricationProviding , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles,square,round, flats, bars, channels, sections complete with cutting, welding, grinding & finishing duly painted with one coat of red oxide with erection on site as per direction of engineer in charge with necessary grouting, cementing, plastering & finishing complete. |
| 511 | CablesProviding and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 300 sq.mm x 3.5c Al. XLPE Arm. Cable |
| 512 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 185 sq.mm x 3.5c Al. XLPE Arm. Cable |
| 513 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 150 sq.mm x 3.5c Al. XLPE Arm. Cable |
| 514 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 120 sq.mm x 3.5c Al. XLPE Arm. Cable |
| 515 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 70 sq.mm x 3.5c Al. XLPE Arm. Cable |
| 516 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 50 sq.mm x 3.5c Al. XLPE Arm. Cable |
| 517 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 25 sq.mm x 4 c Al. XLPE Arm. Cable |
| 518 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 16 sq.mm x 4 c Al. XLPE Arm. Cable |
| 519 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables 10 sq.mm x 4 c Al. XLPE Arm. Cable |
| 520 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.16 sq.mm x 4 c Cu. XLPE Arm. Cable |
| 521 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.10 sq.mm x 4 c Cu. XLPE Arm. Cable |
| 522 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.6 sq.mm x 4 c Cu. XLPE Arm. Cable |
| 523 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.4 sq.mm x 4 c Cu. XLPE Arm. Cable |
| 524 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.6 sq.mm x 3 c Cu. XLPE Arm. Cable |
| 525 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cable.4 sq.mm x 3 c cu. XLPE Arm. Cable |
| 526 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(A) 3 core 2.5 Sq. mm |
| 527 | Cable GlandsProviding and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(I) 3 & 1/2 core 300 Sq. mm |
| 528 | Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(G) 3 & 1/2 core 185 Sq. mm |
| 529 | Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(F) 3 & 1/2 core 150 Sq. mm |
| 530 | Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(E) 3 & 1/2 core 120 Sq. mm |
| 531 | Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(C) 3 & 1/2 core 70 Sq. mm |
| 532 | Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(B) 3 & 1/2 core 35/50 Sq. mm |
| 533 | Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(E) 2 to 4 core 25 Sq. mm |
| 534 | Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(D) 2 to 4 core 16 Sq. mm |
| 535 | Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(C) 2 to 4 core 10 Sq. mm |
| 536 | Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(B) 2 to 4 core 6 Sq. mm |
| 537 | Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(A) 2 to 4 core 2.5 / 4 Sq. mm |
| 538 | Cable Aluminium lugsSolder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (K) 300 Sq.mm. |
| 539 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. ( I ) 185 Sq.mm. |
| 540 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (H) 150 Sq.mm. |
| 541 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (G) 120 Sq.mm. |
| 542 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (F) 95 Sq.mm. |
| 543 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (E) 70 Sq.mm. |
| 544 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (D) 35/50 Sq.mm. |
| 545 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (C) 16/25 Sq.mm. |
| 546 | Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (B) 10 Sq.mm |
| 547 | Cable Copper lugsSolder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (C) 16 Sq.mm. |
| 548 | Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (B) 10 Sq.mm |
| 549 | Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 1.5/2.5 to 6 Sq.mm |
| 550 | MV Switchgear & Power Panels (TTA as per IEC 61439)Supply, Unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning main L.T. panel board, fabricated from M.S. sheet & folded channel totally enclosed cubical type compartmentalized. Scope Covers Unloading at Site, Store in Weather Proof Condition, Shift to the Location Basement / GF / FF, Grouting, Installation, Testing & Commissioning complete in all respect & As per the instruction of Architect / Consultant / Engineer Incharge. Scope also covers Co ordination with Panel Manufacturer. Design, fabrication, assembling, supply, installation , testing of Panels for 415 V, 3 phase, 50 Hz, 4 wire power supply system.Panels shall be fabricated out of 2 mm thick CRCA sheet steel in cubical formation, compartmentalized in Form 4b Construction, floor mounted, free standing and shall be dust and vermin proof. 3 mm thick cable gland plate, shall be provided both at the top and the bottom of the panel. All large panels shall be provided with lifting hooks. Distribution panels shall be fabricated in accordance with the specifications.Note : Panel vendor has to provide Surge Protection at every stage of the Distribution.1) Supporting rigid steel framework.2) Cubicle type, 14 gauge CRCA sheet steel enclosed.3) Complete with interconnections and distribution bus bars.4) Proper bonding to earth.5) Painting/lettering on Breakers and distribution boards, the location they serve, providing on each panel its circuit diagram.6) Providing cable clamps / supports within distribution boards cable alley.7) TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequate size of neutral link.8) All MCB’s shall be of minimum 10 KA breaking capacity.9) The breaking capacity of MCCB’s are mentioned panel wise. 10) All motor feeders MCCBs shall be of motor duty.11) Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5.12) Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993.a) IP 52 for indoor panels.b) IP 54 for Service area panels.c) IP 65 for outdoor panels.13) All MCCB’s shall be provided with operating mechanism for door interlock & with the roraty handle.14) Current density of aluminium shall be 1 sq mm for 0.8 amps for rated current of bus bars and current density of copper shall be 1 sq.mm for 1 amps for rated current of bus bars.15) Tinned copper earth bus as specified in the BOQ / SLD shall be provided through out the length of each board.16) All measuring instruments (Meters) shall be of digital electronic with LED of approved make and compatible with BAS.17) All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.18) All panels shall have provision of the following:a) IP 55 for outdoor panels.b) Pad locking of MCCB’s handles in “OFF” Position.19) Additional set of C.T.s, potential free contacts, connectors, contactors with wiring etc are to be provided for BAS including space required for various transducers in Main Switch Board sections. Only transducers shall be supplied by BAS contractor.20) All the C.T.s should be auto short link type.21) All the MCCB's should be with rotary handle.22) All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. 23) All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation.24) All PTs / control transformer shall be provided with centre tap earth secondary.25) If Any descripancy found in SLD & BOQ, it should be brought in the notice of the Client / Consultant, Client / Consultant's decision will be final in case of any descripancy.26) All outdoor panles should be provided with minimum 600mm height fabrication stand with all side 2mm thick M.S. powder coated sheet.26) G.A. Drawing should be checked & Finalised by consultant before fabrication.MV Switchgear & Power Panels (TTA as per IEC 61439)Supply, Unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning main L.T. panel board, fabricated from M.S. sheet & folded channel totally enclosed cubical type compartmentalized. Scope Covers Unloading at Site, Store in Weather Proof Condition, Shift to the Location Basement / GF / FF, Grouting, Installation, Testing & Commissioning complete in all respect & As per the instruction of Architect / Consultant / Engineer Incharge. Scope also covers Co ordination with Panel Manufacturer. Design, fabrication, assembling, supply, installation , testing of Panels for 415 V, 3 phase, 50 Hz, 4 wire power supply system.Panels shall be fabricated out of 2 mm thick CRCA sheet steel in cubical formation, compartmentalized in Form 4b Construction, floor mounted, free standing and shall be dust and vermin proof. 3 mm thick cable gland plate, shall be provided both at the top and the bottom of the panel. All large panels shall be provided with lifting hooks. Distribution panels shall be fabricated in accordance with the specifications.Note : Panel vendor has to provide Surge Protection at every stage of the Distribution.1) Supporting rigid steel framework.2) Cubicle type, 14 gauge CRCA sheet steel enclosed.3) Complete with interconnections and distribution bus bars.4) Proper bonding to earth.5) Painting/lettering on Breakers and distribution boards, the location they serve, providing on each panel its circuit diagram.6) Providing cable clamps / supports within distribution boards cable alley.7) TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequate size of neutral link.8) All MCB’s shall be of minimum 10 KA breaking capacity.9) The breaking capacity of MCCB’s are mentioned panel wise. 10) All motor feeders MCCBs shall be of motor duty.11) Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5.12) Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993.a) IP 52 for indoor panels.b) IP 54 for Service area panels.c) IP 65 for outdoor panels.13) All MCCB’s shall be provided with operating mechanism for door interlock & with the roraty handle.14) Current density of aluminium shall be 1 sq mm for 0.8 amps for rated current of bus bars and current density of copper shall be 1 sq.mm for 1 amps for rated current of bus bars.15) Tinned copper earth bus as specified in the BOQ / SLD shall be provided through out the length of each board.16) All measuring instruments (Meters) shall be of digital electronic with LED of approved make and compatible with BAS.17) All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.18) All panels shall have provision of the following:a) IP 55 for outdoor panels.b) Pad locking of MCCB’s handles in “OFF” Position.19) Additional set of C.T.s, potential free contacts, connectors, contactors with wiring etc are to be provided for BAS including space required for various transducers in Main Switch Board sections. Only transducers shall be supplied by BAS contractor.20) All the C.T.s should be auto short link type.21) All the MCCB's should be with rotary handle.22) All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. 23) All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation.24) All PTs / control transformer shall be provided with centre tap earth secondary.25) If Any descripancy found in SLD & BOQ, it should be brought in the notice of the Client / Consultant, Client / Consultant's decision will be final in case of any descripancy.26) All outdoor panles should be provided with minimum 600mm height fabrication stand with all side 2mm thick M.S. powder coated sheet.26) G.A. Drawing should be checked & Finalised by consultant before fabrication.SITC of Main LT Panel - Meter - CIncoming : From CSS630 amps FP MCCB (50 KA) with following accessories: 1 Setsi. LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP MCB's. - 5 nos.ii. 3 Nos. of Digital type 0-630 / 5 amps CTR digital ammeter with 3 nos 630 / 5 amps, 15 VA Class I CT’s.iii. Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall be protected by 2 amp TP MCB’s - 1 no.iv) Load Manager of Schneider make PM 5110 with RS 485 connectivity with 3 nos. of Class 1, 630 / 5 Amp. CT of 15 VAIncoming : From DG Set250 amps FP MCCB (36 KA) with following accessories: 1 Setsi. LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP MCB's. - 5 nos.ii. 3 Nos. of Digital type 0-250 / 5 amps CTR digital ammeter with 3 nos 250 / 5 amps, 15 VA Class I CT’s.iii. Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall be protected by 2 amp TP MCB’s - 1 no.iv) Load Manager of Schneider make PM 5110 with RS 485 connectivity with 3 nos. of Class 1, 250 / 5 Amp. CT of 15 VABus Bars630 amps FP Al. bus bars with colored heat shrinkable insulated sleeve.Surge Arresters - Type 1+ 2, Iimp up to 25kA & Imax upto 40kAATS630 amps with following accessories: 1 Setsi. LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP MCB's. - 5 nos.Outgoing :250 amps 4 pole MCCB ( 36 KA) : 1 Nos.125 amps 4 pole MCCB ( 25 KA) : 1 Nos.100 amps 4 pole MCCB ( 25 KA) : 1 Nos.63 amps 4 pole MCB (10KA) : 2 Nos.40 amps 4 pole MCB (10KA) : 2 Nos.32 amps 4 pole MCB (10KA) : 9 Nos.6 to 32 amps 2 pole MCB ( 10 KA) : 8 Nos.Panel should be as per SLD & Specifications |
| 551 | SITC of Main UPS Panel - Meter - CIncoming : From Main LT Panel100 amps FP MCCB (25 KA) with following accessories: 1 Setsi. LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP MCB's. - 5 nos.ii. Multifunction meter with RS 485 connectivity with 3 nos. of Class 1, 100 / 5 Amp. CT of 15 VABus Bars100 Amps FP Cu. bus bars with colored heat shrinkable insulated sleeve.Surge Arresters - Type 1+ 2, Iimp up to 25kA & Imax upto 40kAOutgoing :32 amps 4 pole MCB (10KA) : 4 Nos.6 to 32 amps 2 pole MCB ( 10 KA) : 6 Nos.Panel should be as per SLD & Specifications |
| 552 | Meter- CDesign, Supplying, installing, testing of factory fabricated ready made Three phase APFC Panel Cubical Panel fabrication should be type tested as per IEC 61921, 61439:1&2 Capacitor Duty Contactor for switching as per following Steps Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection,Copper tinned insulated Busbar,Cubical panel should be indoor type with IP 43 and IK 10,Metalized polypropylene film tye3-phase 550Volt Capacitor,De tuning Reactor for each capacitor,Panel having Short Circuit and Overload protection,Each step Capacitor having suitable MCB with Sc, OL, internal earth fault relay,Each stage having Stage Contactor (Capacitor load rating),PF regulator master controller having suitable steps with LCD display, Rs 485 Communication port, Indication LED Lamps for main incomer and ON-OFF for each capacitor bank,MS Chanel for Floor mounting, Cable entry as per site situation,Cooling fans for panel(E)150KVAR |
| 553 | SITC of Main LT Panel - Meter - DIncoming : From CSS400 amps FP MCCB (36 KA) with following accessories: 1 Setsi. LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP MCB's. - 5 nos.ii. 3 Nos. of Digital type 0-400 / 5 amps CTR digital ammeter with 3 nos 400 / 5 amps, 15 VA Class I CT’s.iii. Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall be protected by 2 amp TP MCB’s - 1 no.iv) Load Manager of Schneider make PM 5110 with RS 485 connectivity with 3 nos. of Class 1, 400 / 5 Amp. CT of 15 VAIncoming : From DG Set160 amps FP MCCB (36 KA) with following accessories: 1 Setsi. LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP MCB's. - 5 nos.ii. 3 Nos. of Digital type 0-160 / 5 amps CTR digital ammeter with 3 nos 160 / 5 amps, 15 VA Class I CT’s.iii. Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall be protected by 2 amp TP MCB’s - 1 no.iv) Load Manager of Schneider make PM 5110 with RS 485 connectivity with 3 nos. of Class 1, 160 / 5 Amp. CT of 15 VABus Bars400 amps FP Al. bus bars with colored heat shrinkable insulated sleeve.Surge Arresters - Type 1+ 2, Iimp up to 25kA & Imax upto 40kA |
| 554 | SITC of Main UPS Panel - Meter - DIncoming : From Main LT Panel40 amps FP MCB (10 KA) with following accessories: 1 Setsi. LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP MCB's. - 5 nos.Bus Bars40 Amps FP Cu. bus bars with colored heat shrinkable insulated sleeve.Outgoing :32 amps 4 pole MCB (10KA) : 5 Nos.6 to 32 amps 2 pole MCB ( 10 KA) : 6 Nos.Panel should be as per SLD & Specifications |
| 555 | Meter- DDesign, Supplying, installing, testing of factory fabricated ready made Three phase APFC Panel Cubical Panel fabrication should be type tested as per IEC 61921, 61439:1&2 Capacitor Duty Contactor for switching as per following Steps Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection,Copper tinned insulated Busbar,Cubical panel should be indoor type with IP 43 and IK 10,Metalized polypropylene film tye3-phase 550Volt Capacitor,De tuning Reactor for each capacitor,Panel having Short Circuit and Overload protection,Each step Capacitor having suitable MCB with Sc, OL, internal earth fault relay,Each stage having Stage Contactor (Capacitor load rating),PF regulator master controller having suitable steps with LCD display, Rs 485 Communication port, Indication LED Lamps for main incomer and ON-OFF for each capacitor bank,MS Chanel for Floor mounting, Cable entry as per site situation,Cooling fans for panel(C)100KVAR |
| 556 | SITC of IP 65 External Area lighting Panel Incoming :63 amps FP MCB (16 KA) with following accessories: 1 SetsLED type Phase indicating & ON, OFF light shall be protected by 2 amps SP MCB's.3 Nos. of Digital type 0-63 / 5 amps CTR digital ammeter with 3 nos 63 / 5 amps, 15 VA Class I CT’s.Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall be protected by 2 amp TP MCB’s Bus Bars63 amps FP Tinned copper bus bars with coloured heat shrinkable insulated sleeve.Surge Arresters - Type 2, Iimp up to 20kA Outgoing40 to 63 amps 4 pole MCB ( 10 KA ) : 6 No.6 to 32 amps FP 4 pole MCB : 2 no.40 to FP Contactor : 6 no.Dual channel Timer : 3 nos.Panel should be as per SLD |
| 557 | Light FixtureSITC of Any kind of Light Fixture with Basic Rate of Rs. 1000 |
| 558 | SITC of Any kind of Light Fixture with Basic Rate of Rs. 1500 |
| 559 | SITC of Any kind of Light Fixture with Basic Rate of Rs. 2000 |
| 560 | SITC of Any kind of Light Fixture with Basic Rate of Rs. 4000 |
| 561 | SITC of Any kind of Light Fixture with Basic Rate of Rs. 10000 |
| 562 | SITC of Any kind of Light Fixture with Basic Rate of Rs. 25000 |
| 563 | SITC of Any kind of Light Fixture with Basic Rate of Rs. 30000 |
| 564 | SITC of Any kind of DMX Controller including all accessories and programming with Basic Rate of Rs. 60000 |
| 565 | SITC of Lead Cable as per specification Lead 5P DC/DMX cable. The cable should be with IP67 Connector. |
| 566 | SITC of DC/DMX//RDM Jumper cable as per specification Jump 5P DC/DMX cable. The cable should be with IP67 Connector. |
| 567 | SITC of Y - connector kit of Y-connect kit 5P DC/DMX . The cable Kit should be with IP67 Connector. |
| 568 | SITC of DMX connector as per specification of Jump 5P DMX connector . The connector should be IP67. |
| 569 | SITC of IP67 Male / Female endcap Connector of endcap male connector. |
| 570 | SITC of LED Rope Light with Connector, IP 65 Water-Proof Strip Light with 400 lumens/ Meter with LED driver and all kind of accessories etc.. |
| 571 | Exhaust Fans :Supplying & erecting approved make low noise decorative exhaust fan having square frame ABS body with inbuilt lowers & square frame.200mm with 1350RPM Cat.II |
| 572 | Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM[A] 305 mm dia 900 RPM. Cat.II |
| 573 | Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm sweep complete having 3blades with aluminium blades with , canopy & 30 cm. down rod erected with earthing.(Make shall be approved by Engineer in charge)) |
| 574 | Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with proper insulation without leakage and earthing. |
| 575 | Street Light PoleSupplying and erecting approved make Conical Pole (Medium Duty ) Made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/2633/4759, with required base plate and integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for cable terminations as erected on suitable foundation (included) with necessary GI nut-bolts/J-Bolts. as per details given by manufacturer considering site requirement. The length of poles are as below.(B) 4 Mtr. Long 70 mm Top X 130 mm bottom dia, 3 mm thickness(iii) Add Extra for PU base primer and PU Paint on pole. |
| 576 | Supplying and erecting approved make Conical Pole (Medium Duty ) Made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/2633/4759, with required base plate and integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for cable terminations as erected on suitable foundation (included) with necessary GI nut-bolts/J-Bolts. as per details given by manufacturer considering site requirement. The length of poles are as below.(D) 6 Mtr. Long 70 mm Top X 160 mm bottom dia, 3 mm thickness(iii) Add Extra for PU base primer and PU Paint on pole. |
| 577 | Supplying and erecting approved make Conical Pole (Medium Duty ) Made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/2633/4759, with required base plate and integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for cable terminations as erected on suitable foundation (included) with necessary GI nut-bolts/J-Bolts. as per details given by manufacturer considering site requirement. The length of poles are as below.(F) 8 Mtr. Long 70 mm Top X 190 mm bottom dia, 3 mm thickness(iii) Add Extra for PU base primer and PU Paint on pole. |
| 578 | Providing and erecting street light pole bracket comprising main B Class GI pipe of 4.2 cm/require outside dia. complete with suitable B Class G.I sleeve tubing of approx. 45cms.length and suitable for 76.5 mm / 80mm. / require size pole top having sufficient fasteners for fixing the brackets and having spread of 1 mtr. length with suitable rise as per site condition & suitable welded stiffener reducer and nipple with check nut complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with following nos of arms.[A] Single Arm Bracket 1.0 Mtr |
| 579 | Providing and erecting street light pole bracket comprising main B Class GI pipe of 4.2 cm/require outside dia. complete with suitable B Class G.I sleeve tubing of approx. 45cms.length and suitable for 76.5 mm / 80mm. / require size pole top having sufficient fasteners for fixing the brackets and having spread of 1 mtr. length with suitable rise as per site condition & suitable welded stiffener reducer and nipple with check nut complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with following nos of arms.[B] Double Arm Bracket 1.0 Mtr |
| 580 | FabricationProviding , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles,square,round, flats, bars, channels, sections complete with cutting, welding, grinding & finishing duly painted with one coat of red oxide with erection on site as per direction of engineer in charge with necessary grouting, cementing, plastering & finishing complete. |
| 581 | Street Light Pole & High MastSupply, Installation, Testing & Commissioning of 25 Mtr ( Height up to top of the head frame) Fixed type Stadium High Mast with Head frame and platform to support minimum 30 Nos of 1.2 to 1.25 KW Fixtures not more than 40Kgs with driver. The high Mast shall be made of continuously tapered polygonal sections of lengths to arrive at the specific height. The high mast shall be structurally designed in accordance with technical report no 7 published by institution for lighting engineer U.K. and to withstand the wind speed of 158 km/hr. as per IS 875 Part III. The mast section should be manufactured with special steel grade S 355 in compliance with BSEN 10025. Each section of the mast shall be hot dip galvanized through single dip process as per EN- ISO-1461:1999 and IS 11759-1985. Average thickness of galvanizing shall not be less than 85 micron. All welding shall be undertaken and performed as per BS 5135. The head frame shall be made of suitable steel grade duly galvanized and equipped with suitable provision for mounting of floodlights. Provision should be in the high mast for man rider unit to access the light fixtures. All MS part including hardware shall be hot dip galvanized as per BS729/BSENISO 1461 standard. Base section of the high mast shall be provided with weather proof service door having vandal resistance lock. Dimensional tolerance shall be as per BSEN 40. with lightning arrestor, The specification High Mast , thickness of section ( Bottom – 6mm , Middle -5 mm , Top -5mm ) with Minimum Dia Top-350mm , Bottom -880 mm , PCD-1000 mm , Base Plate-1120mm x 35 mm , with Bolt 16 Nos M39x850mm (GA drawing of the high mast should be approved by independent structure consultant and certificate for the same should be provided) with suitable earthing, Lightning arrestor and Aviation light. - Minor variation in High mast Diameter can be accepted. |
| 582 | SITC of external man rider + unit for accessing the head frame. The unit shall be suitable for safe load carrying capacity of 300 Kg. with climb speed not exceeding 9m x /min. |
| 583 | SITC foundation of 25mtr height Stadium high mast including Design, Approval Excavation, Back filling, RCC, TMT, Foudation bolt complete in all respect. |
| 584 | Providing & erecting Steel Flexible Conduit with required nos. of coupling, steel bushes, Check-nuts etc. complete of following sizes.25 mm |
| 585 | Providing & erecting Steel Flexible Conduit with required nos. of coupling, steel bushes, Check-nuts etc. complete of following sizes.32 mm |
| 586 | Providing & erecting Steel Flexible Conduit with required nos. of coupling, steel bushes, Check-nuts etc. complete of following sizes.50 mm |
| 587 | UPSSupplying and erecting approved make online Un-interruptible Power Supply system comprising flat cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance free SMF batteries. The charger having operating capacity for input 160-270V AC & inverter having output 230V,50 Hz Ac with 0.8 load power factor with battery, over/under voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with following power backup.with MS painted batteries stand, 10% Overload capacity for momentary load.(J) 20 KVA 3 - phase with 1Hr Backup |
| 588 | UPSSupplying and erecting approved make online Un-interruptible Power Supply system comprising flat cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance free SMF batteries. The charger having operating capacity for input 160-270V AC & inverter having output 230V,50 Hz Ac with 0.8 load power factor with battery, over/under voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with following power backup.with MS painted batteries stand, 10% Overload capacity for momentary load.[M]60 kVA 3 - phase with 1Hr Backup |
| 589 | EarthingSupplying & erecting funnel type earthing having earth plate of following size burred in specifically prepared earth pit 3 mtr. below ground with 40 kg. charcoal and salt with alternate layers of charcoal & salt, 20mm.dia. G.I. pipe with Funnel with a wire mesh for watering & bricks masonry block, C.I. Cover complete as per para 7.3 of IS 3043 with necessary length of double Galvanised Iron / copper earth wire No 6 SWG bolted with lug to the plate and covered in 12 mm dia. G.I. pipe 2.5 mtr long complete connected to the nearest switch gear with end socket as per direction & duly tested by earth tester confirming to IS (As per drawing) with following specification (C) with 60 x 60x 0.315 cms. Copper earth Plate |
| 590 | Supplying & erecting in earthpit of minimum bore dia. 225mm size approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection terminal dia of 14 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover (A)(approved make OEM has to submit test certificate including value of earth resistance of installation duly stamped and signed by agency and officer Incharge has to ensure the value of earthing resistane mentioned in test Certificate) & having back filling compound of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing compound should be capable to retain moisture for long time Necessary test report must be submitted by Agency.[C] For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant & Sensitive Computer System(like Automation, SCADA)i.e. independent Earthing located in other than normal soil i.e. Soft Rock, Marshy Soil etc..-Length of Pipe : 3 Mtrs. -Back filling Compound :2 nos Bags of 25 Kg. |
| 591 | Providing and erecting Pipe type earthing with 40 mm dia 2.5 mtr long 'B' grade G.I. pipe with necessary coupling buch buried in specially prepared earth pit & G.I. earth wire of 8 SWG erected & connected as directed (For panel) |
| 592 | Earth wire/strips :Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG. |
| 593 | Providing and erecting Annealed bare Copper wire 8 to 16 SWG. |
| 594 | Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp. |
| 595 | Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/ Transformer, LT panel board, Motors etc. using copper clamp. |
| 596 | providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required.(e) One wire 6.00 sq. mm |
| 597 | Providing & erecting approved make street light / wall mounting junction box compression moulded from SMC (thermoset plastic) vertical sliding cover having locking with square head stud loop in / loop out in built terminal suitable for four core cable, waterproof of I.P. 54 protected with clamp or bolt nut & earth bolt of following size.(A) 200mm x 127mm x 83 mm |
| 598 | Telephone DistributionProviding & erecting main Distribution (MDF) indoor type, back mounted frame as per DoT standard approved with krone strips(a) Suitable for 10 pair |
| 599 | Telephone Point WiringSupplying & erecting approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos.of pairs. With necessary connections.[A] Conductor Size 0.5 mm (a) Unarmoured(5) Ten Pairs |
| 600 | Telephone Outlet PointProviding following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with necessary connections as per site situation directed by Engineer In charge.(3) Two Pin/RJ-11 Telephone Socket[A] For One Gang. Cat.III |
| 601 | Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with necessary connections as per site situation directed by Engineer In charge.(8) Computer RJ-45 socket Cat.III |
| 602 | SITC of 24 x 10/100/1000BASE-T ports4 x Gigabit RJ45/SFP Combo portsAdvanced L2 switching and security featuresL2+ Static RoutingOptional “standard mode” or “surveillance mode” management user interface [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] |
| 603 | SITC of 48 x 10/100/1000BASE-T ports4 x Gigabit GbE/SFP combo portsAdvanced L2 switching and security featuresL2+ Static RoutingOptional “standard mode” or “surveillance mode” management user interface [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] |
| 604 | CCTVSupplying Installation Testing and Commissioning of 2MP IP IR Dome Camera having following specifications, type of lens and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB, Camera should display Camera title, Date & Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1 .4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711 Mu, G.726, AAC, G.7234) Wide Dynamic Range:-WDR (120db or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming ,configurable (Main stream: 2MP (1920 1080)@25/30 fps,Sub streams minimum:720P@25/30 fps).7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot.9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.10) Recording Management: Format SD, overwrite, storage management, video to NAS device11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast13) System Capability: ONVIF, Camera shall support open source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.16) Power Input: The camera should support simultaneous dual power input-12 VDC (via power adapter) and PoE (802.3af)-to ensure continuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VAC/PoE (802 .3af)/ePoE18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body19) Operating Condition:- Ambient Temperature:- (• )05°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS -8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS2MP (@ 25/30fps@1080P (19201080)) IP IR DomeCamera with 2.8/ 3.6mm fixed lens |
| 605 | Supplying Installation Testing and Commissioning of 2MP Fixed Lens IP IR Outdoor Bullet Camera having following specifications and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live & recorded video 2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1 .4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt Smart IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711 U/A, G.711 Mu, G.726, AAC, G.7234) Wide Dynamic Range:-WDR (120db or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming, configurable(Main stream: 2MP (1920 1080)@25/30 fps Sub streams minimum:720P@25/30 fps).7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot.9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.10) Recording Management: Format SD, overwrite, storage management, video to NAS device,11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP- TCP/IP, PPPoE,NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,unicast,13) System Capability: ONVIF, Camera shall support open source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.16) Power Input: The camera should support simultaneous dual power input-12 VDC (via power adapter) and PoE (802.3af)-to ensure continuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body19) Operating Condition:- Ambient Temperature:- (•)05°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS -8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS2MP @ 25/30fps@1080P (19201080) Outdoor Bullet Camera with 2.8/ 3.6mm fixed lens |
| 606 | Supplying Installation Testing and Commissioning of PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc :-PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc:-1) IP IR PTZ Camera: Motorized PAN TILT ZOOM with IR2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS3)Signal System: PAL/NTSC4) Minimum Illumination: 0.008 Lux@ F1 .6, AGC ON,,0 lux with IR, or better5) Imaging: 1/1 s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Image Rotation, Multi zone Privacy Masking (Upto 24 Area), HLC, Defog, Region Of Interest and EIS features.6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both.7) Signal to Noise Ratio: > 50 dB8) Event Notification: Through Relays, E-Mails or FTP9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source• Inbuilt IR LED's with effective distance. The camera should have IR LED's and cover distance up to 300 meter or above10) Auto Tracking: The camera should be equipped with Deep-learning-based auto tracking function using simultaneously all of the panning, tilting and zooming should be available. When a motion is detected in a registered monitoring area, the camera should track the motion (object) and capture it.11) Pre/Post Event Buffering: The camera should support atleast of 5 seconds of pre & post event buffering.12) Presets: 300 Presets13) Video Compression (Minimum): H.265 or better, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.72314) Wide Dynamic Range: WDR (120dB or more), HLC & BLC15) Digital Noise Reduction: DNR (2D+3D) On/Off16) Image Setting: Rotate Mode, ROI ,EIS, Defog, saturation, brightness, contrast, sharpness adjustable through client software or web browser17) Profile Management: User configuration import, export18) Cyber Security: Configuration encryption, AES256-bit Encryption, Digest, account lockout, video encryption, IP/MAC filtering, trusted boot, trusted upgrade, trusted execution19) Onboard Storage: Camera should support built in Micro SD/SDHC/SDXC Card slot upto 512 GB .It should be supplied with minimum 128GB Memory.20) Recording Management: Format SD, overwrite, storage management, video to NAS device, remote archive access via FTP login21) Edge based Video Analytics & Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection, Tripwire,Intrusion,Detection Object Abandon/Missing, SMD, Face22) Network Protocol: SFTP, IPv6, IPv4, DNS,NTP,HTTP, HTTPS, SNMP, TCP/IP, PPPoE, NFS, ICMP, DHCP, SMTP, RTSPS.23) System Capability: ONVIF Profile S, G & T. CCTV Camera OEM should be fulltime member of ONVIF and quoted models should be listed on ONVIF official website (All the certifications & Credentials should be valid on the date of technical evaluation).24) VMS: Camera shall support open source VMS25) Connectivity: 1x LAN RJ-45 (10/100Base-T)26) Audio Support: Audio Interface : The camera should have 1/1 Audio In/Out to connect External Mic and Speaker Audio Compression : PCM, G.711 U/A, G.711MU, G.726, MPEG2-Layer2, G.722.127) Alarm In/Out: Alarm In/out- 7/2 Ch In/Out28) Power Input: The camera should support simultaneous dual power input-DC/ AC (via power adapter) and PoE (802.3af)-to ensure continuous operation in the event of a failure in one power source.29) Power Requirement: 24 voe, 2.5 A (± 25%), PoE+ (802.3at)30) Enclosure & Weather Proof Standard: IP67 weather proof and IK10, TVS 8000V lightning proof, surge protection, voltage transient protection31) Operating Condition:- Ambient Temperature:- (•)05°C to 50°C, humidity 95% (max) (non-condensing)32) IR life: 40000 hours or higher33) Video Bit rate: 32 KBPS -8 MBPS or better34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS2 MP IP IR motorized PTZ @ 25/30fps or better camera, Triple streaming , configurable on resolution Main stream: 1080p@25/30 fps Sub streams :1080p@25/30 fps & D1@25/30 fps or better, varifocal lens 4.3-137 mm or better with Automatic & manual Focus Adjustment provisions, 32x Optical zoom and 12x Digital zoom with angle of view ST-2.4 °, PAN Travel: Pan: 0° - 360° endless, Manual Pan: 260° /s, Preset : 300° /s, Tilt, Travel: Tilt: -20° 90°, auto flip 180°, Manual TiIt: 120° /s, Preset: 200°/s |
| 607 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below :1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or more and must be ONVIF with minimum support of 384 Mbps incoming Bandwidth.2) NVR should support video compressions : H.265 or better, H.264, MJPEG.3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711 U/A, G.711 u, PCM, G726 audio compressions.4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10.6) Connectivity Interface :2 Nos.x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)8) Video Output Ports: 2x HDMI and 2 VGA9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HOD failure, vandalism, tempring, network disconnection and panic11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing.12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP, DONS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SOK and OEM Cloud for remote monitoring without any public IP need.13) Standards: CE, FCC, RoHS, BIS Certified14) Power Supply : Should support AC100-240V, 50/60Hz Power supply.15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing)16) The VMS application shall support all the features & functionalities of the offered cameras.17) VMS should consist Licenses for all channels to record Cameras with General, motion detection, intelligent, alarm and POS recording modes. VMS should be provided with Camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality.18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage.19) The OEM must provide its own DONS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF22) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page23) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm24) It should have Web and GUI interface.25) Built-In Artificial Intelligence: NVR should have built-in Al - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to add Name, gender, birthday, address, credential type, credential No., countries & regions and state to each face image.27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella.28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes.29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.31) General Al Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection,Violence Detection.32) Smart playback function: Should support smart Search for the selected area in the video and smart playback to improve the playback efficiency 33) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics 34) Analytics by NVR: Perimeter protection and face recognation 64 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/36/64, 2nd screen: 1/4/8/9/16 |
| 608 | 32 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/32(36), 2nd screen: 1/4/8/9/16 |
| 609 | Hard Disk DriveSupplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.10T8 (T erabytes) |
| 610 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.9U Rack |
| 611 | Supplying and fixing 24U Rack with 4 inch Castor wheels and front brake Floor Standing Rack with Main Frame Pillar of 1.25mm Powder Coated CRCA Sheet with removable side panels, L- Shape Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-down condition (CKD) Shape, fitted with 4 number cooling fans, minimum 5nos two line cable entry/exit provision at top and bottom with rubber protection, Front door 5mm Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or perforated door, Powder coated Color- RAL- 7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 612 | SITC of 24 x 10/100/1000BASE-T PoE ports, 4 x Gigabit RJ45/SFP Combo ports, Advanced L2 switching and security features, L2+ Static Routing Optional “standard mode” or “surveillance mode” management user interface 193 W PoE budget, [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] |
| 613 | SITC of Patch Panel Cat 6 UTP Keystone Type- 24 Port-Fully Loaded [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] |
| 614 | SITC of CAT6 UTP 24AWG PATCH CORD:1M,Plug 30U' Snag less [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] |
| 615 | Supply, Installation Testing & Commissioning 10 Mtr. HDMI Interface Cable as per the detailed Specifications supports transmission of 4K Signals as per the detailed Specifications |
| 616 | Supply, Installation Testing & Commissioning 15 Mtr. HDMI Interface Cable as per the detailed Specifications supports transmission of 4K Signals as per the detailed Specifications |
| 617 | Supplying & erecting approved make LAN cable of following size in existing pipe as per direction[C] CAT - 6 |
| 618 | Providing & Erecting 6 core fibre optic SM 9/125um double sheath, CSTA, Unitube, Outdoor cable (per m) |
| 619 | Fire Detection SystemSupplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shall be compatible for ISMS system with open protocol BACnet/ Modbus over IP complete as per specificationsTen Loop Panel. |
| 620 | Supplying, installation, testing & commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. |
| 621 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 622 | Supplying, installation, testing & commissioning of heat detector operating at 54C/57C with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. |
| 623 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 624 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required |
| 625 | Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required. |
| 626 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 627 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 628 | Supplying & laying of 2x1 .5 sqmm fire alarm armoured cable, 600/1 000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. |
| 629 | Supply & laying of 4 Core X 1.5 sq.mm. FRLS Armoured PVC Insulated copper cable |
| 630 | PA SystemSupplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP4 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. |
| 631 | Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. |
| 632 | Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. |
| 633 | Supply installation testing and commissioning of power amplifier 480 W power amplifier in a 3U high 19” housing, 70 V / 100 V and 8 Ohm outputs, 100 V input for slave operation on 100 V speaker line.Bosch LBD1938/00 |
| 634 | Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. |
| 635 | Supply installation testing and commissioning of Wall mount volume controller . |
| 636 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Single pair, 2-core, 1.5 sqmm |
| 637 | Lightning ArrestorSITC of Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol |
| 638 | Supply of 8 mm dia solid Aluminium Conductor tested as per IEC 62561-2 conducted in the Govt. aggregated thirty party laboratory to meet the requirement of IS/ IEC 62305 |
| 639 | Supply of Al. Straight Splicers for 8mm and 10 mm Conductor to meet the requirement of IS IEC 62305 tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol |
| 640 | Supply of Expansion Piece without connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations to be provided on conductors length over 20 meters to connect Solid Round Al. Conductor at both ends to meet the requirements of IS/IEC 62305. |
| 641 | Supply of Cross splicer should be ttested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 0f IEC 62561-1 2017 protocol |
| 642 | Supply of 8 mm dia solid Aluminium Conductor tested as per IEC 62561-2 conducted in the Govt. aggregated thirty party laboratory to meet the requirement of IS/ IEC 62305 |
| 643 | Su ply of 25 X 6 mm GI strip from AL Conductor to the earth pit station and further the same strip shall be used for interconnecting all the earth pits below ground leve Zinc coating: 500 g/m square (Approx :70 micron coating) Should betested and use exclusively for lightning protection ,earthing system and ringequipotential bonding |
| 644 | Holder -GI for fixing 25 x 6 mm GI Strip |
| 645 | Each down-conductor should be provided with a test link in order to disconnect the earth termination system for enabling measurements. SS Test Link To connect Round to Flat conductor. |
| 646 | Supply of Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for co nditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protoco l MAST 34mm dia 3 mtr long- Cold Galvanised for Side Mounting without Base Plate |
| 647 | Holder -GI-C-type for fixing 34mm Dia mast on masonarv W all-side mounting |
| 648 | Polyamide Holder for fixing 8mm dia Conductor |
| 649 | Jet Earth Electrode Cu Bonded Steel Rod 14.2mm dia x 3000mm-(250Microns)Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit Chamber with following dimensions :254 mm dia (top), 330 mm dia (bottom) & 260 mm (height). 14.2 / OD SS Clamp Both Side Jet Eco Safe carbon based backfill compound - 50 Pounds |
| 650 | Supply of co ncrete block for fixing/Mounting Vertical Air Termination/ Mast on RCC Floor with special co ncrete co mpound Quick and easy mounting of interception rod using anchor. |
| 651 | Concrete block for Conductor fixing- 100x100x50mm thick |
| 652 | MiscellaneousSupplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete.[A] For 4.5 Kg Capacity |
| 653 | Supplying rubber matting of following thickness as per IS:15652/IEC 61111 (c)12mm |
| 654 | Providing and erecting metallic vitrified danger notice board as per language suggested by engineer incharge for MEDIUM VOLTAGE installation to be erected as per IS-2551. |
| 655 | Providing and fixing printed instruction chart both in English and Gujarati and duly framed with front glasses, for treatment of person suffering from Electric shock with minimum 50\\" diagonally size. |
| 656 | Providing, supplying, installing, testing and commissioning of 2400 mm (8 ft) dia High Volume Low Speed (HVLS) fan, complete with high-efficiency gearless/BLDC motor, aerodynamic airfoil blades, central hub, suspension/mounting arrangement, safety cables, variable speed controller/VFD and all necessary accessories. Fan shall have minimum air delivery of 30,000 CFM (approx. 850 CMM), variable operating speed of approximately 50–250 RPM, motor capacity minimum 0.75 kW or adequate to meet specified performance, maximum power consumption 1.0 kW, noise level not exceeding 60 dB(A), suitable for 415 V, 3-phase, 50 Hz supply. The item shall include all mounting hardware, suspension rods, safety arrangements, electrical connections, transportation, erection, alignment, testing and commissioning, complete in all respects as per manufacturer's recommendations and as approved by the Engineer-in-Charge. Minimum 2 years comprehensive warranty shall be provided. |
| 657 | Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground / road surface for enclosing cable (A)50 mm outer dia |
| 658 | Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground / road surface for enclosing cable (C)90 mm dia |
| 659 | Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground / road surface for enclosing cable (D)120 mm dia |
| 660 | Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground / road surface for enclosing cable200 mm dia |
| 661 | Supplying and stacking of good earth at site. Good earth shall consist of a free draining organic soil from horizons less that 300mm from the original surface, of a workable crumbly and lump free loamy character and shall contain no grass or weed growth of any kind or other foreign material or stones exceeding 25mm in diameter. Sample will be approved by landscape architect. Item includes all royalty, equipment, labour, loading, unloading, and carriage upto any lead & lift required for supply and stacking of good earth. |
| 662 | Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 05 k.m. lead complete (Cattle manure measured in stacks will reduced by 8% for Payment). |
| 663 | Preparation of beds for hedging and shrubbery by excavating 60 cmdeep and trenching the excavated base to a further depth of 30 cm,refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) |
| 664 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Holes 1.2 m dia and 1.2 m deep |
| 665 | Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure) |
| 666 | Grassing with selection No. 1 Doob grass including watering andmaintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately). With grass Tur |
| 667 | Supply of Shrubs and ground cover - well developed, well branched - 3-4 branches each having 4-5 leaves, preferably in bloom, in polybag of 8 * 10mm size, disease free and development. Supply shall include labour & equipment cost of loading, unloading, transport to site, storage & stacking within site in area protected from dust using temporary agronet, watering & maintenance at stacking area until planted as directed by landscape architectAdhatoda vasica, Bushy, dense from bottom,healthy, Min Ht(mm) 400, O.C.(mm) 200 , Bag size(inch) 7*8 |
| 668 | Acalypha wilkesiana green, Bushy, dense from bottom,healthy, Min Ht(mm) 400, O.C.(mm) 200 , Bag size(inch) 7*8 |
| 669 | Alocasia macrorrhizos, Bushy, dense from bottom,healthy, Min Ht(mm) 4000, O.C.(mm) 300 , Bag size(inch) 8*10 |
| 670 | Alpinia nutans, Bushy, dense from bottom,healthy, Min Ht(mm) 4000, O.C.(mm) 300 , Bag size(inch) 8*10 |
| 671 | Alpinia zerumbet variegated, Bushy, dense from bottom,healthy, Min Ht(mm) 600, O.C.(mm) 300 , Bag size(inch) 8*10 |
| 672 | Angelonia angustifolia, Bushy, dense from bottom, healthy, Min Ht(mm) 300, O.C.(mm) 250 , Bag size(inch) 7*8 |
| 673 | Angelonia angustifolia pink, Bushy, dense from bottom, healthy, Min Ht(mm) 300, O.C.(mm) 250 , Bag size(inch) 7*8 |
| 674 | Asystasia gangetica,Bushy, dense from bottom, healthy, Min Ht(mm) 300, O.C.(mm) 250 , Bag size(inch) 5*6 |
| 675 | Caesalpinia pulcherrimaBushy, dense from bottom,healthy, Min Ht(mm) 600, O.C.(mm) 300 , Bag size(inch) 7*8 |
| 676 | Cestrum nocturnum, Bushy, dense from bottom,healthy, Min Ht(mm) 600, O.C.(mm) 300 , Bag size(inch) 7*8 |
| 677 | Costus woodsonii, Bushy, dense from bottom,healthy, Min Ht(mm) 600, O.C.(mm) 300 , Bag size(inch) 8*10 |
| 678 | Heliconia psittacorum, Bushy, dense from bottom,healthy, Min Ht(mm) 800, O.C.(mm) 300 , Bag size(inch) 8*10 |
| 679 | Heliconia psittacorum variegated, Bushy, dense from bottom,healthy, Min Ht(mm) 800, O.C.(mm) 300 , Bag size(inch) 8*10 |
| 680 | Hibiscus tiliaceus, Bushy, dense from bottom,healthy, Min Ht(mm) 800, O.C.(mm) 300 , Bag size(inch) 7*8 |
| 681 | Hymenocallis littoralis, Bushy, dense from bottom,healthy, Min Ht(mm) 400, O.C.(mm) 300 , Bag size(inch) 7*8 |
| 682 | Hymenocallis littoralis variegata, Bushy, dense from bottom,healthy, Min Ht(mm) 400, O.C.(mm) 300 , Bag size(inch) 8*10 |
| 683 | Jasminum auriculatum, Bushy, dense from bottom,healthy, Min Ht(mm) 600, O.C.(mm) 300 , Bag size(inch) 10*10 |
| 684 | Jasminum sambac, Bushy, dense from bottom,healthy, Min Ht(mm) 600, O.C.(mm) 300 , Bag size(inch) 8*10 |
| 685 | Jasminum sambac but mogra, Bushy, dense from bottom,healthy, Min Ht(mm) 600, O.C.(mm) 300 , Bag size(inch) 7*8 |
| 686 | Lawsonia inermis, Bushy, dense from bottom,healthy, Min Ht(mm) 600, O.C.(mm) 200 , Bag size(inch) 7*8 |
| 687 | Murraya paniculata, Bushy, dense from bottom,healthy, Min Ht(mm) 800, O.C.(mm) 300 , Bag size(inch) 8*10 |
| 688 | Ocimum gratissimum, Bushy, dense from bottom,healthy, Min Ht(mm) 300, O.C.(mm) 200 , Bag size(inch) 7*8 |
| 689 | Ocimum tenuiflorum, Bushy, dense from bottom,healthy, Min Ht(mm )300, O.C.(mm) 200 , Bag size(inch) 7*8 |
| 690 | Plumbago auriculata, Bushy, dense from bottom,healthy, Min Ht(mm) 400, O.C.(mm) 300 , Bag size(inch) 8*10 |
| 691 | Pseuderanthemum reticulatum, Bushy, dense from bottom,healthy, Min Ht(mm) 400, O.C.(mm) 300 , Bag size(inch) 7*8 |
| 692 | Quisqualis indica dwarf, Bushy, dense from bottom,healthy, Min Ht(mm) 600, O.C.(mm) 300 , Bag size(inch) 8*10 |
| 693 | Tecoma alalta, Bushy, Bushy, dense from bottom,healthy, Min Ht(mm) 600, O.C.(mm) 300 , Bag size(inch) 8*10 |
| 694 | Tecoma gaudichaudi, Bushy, dense from bottom,healthy, Min Ht(mm) 800, O.C.(mm) 300 , Bag size(inch) 7*8 |
| 695 | Thunbergia erecta, Bushy, Bushy, dense from bottom,healthy, Min Ht(mm) 600, O.C.(mm) 300 , Bag size(inch) 7*8 |
| 696 | Vitex negundo, Bushy, dense from bottom,healthy, Min Ht(mm) 800, O.C.(mm) 300 , Bag size(inch) 7*8 |
| 697 | Supply of Trees - well developed, well branched crown - 4-6 branches each having 4-5 leaves, well developed (Poly bag size - 25\\"x 25\\", min. stem diameter 50mm and height as specified) Trees shall be large size nursery grown trees pruned during growth to produce a tight well rounded head and a straight stem clear of leaves or twigs. Trees shall be at least two years old, as certified by the nursery. The head shall be well balanced and rounded and contain at least four main branches with a well-developed secondary branch system and a defined central leader that has not been pruned.Bahunia purepurea, Straight,healthy,dense, 75 mm calliper, flowering(in season), Min Ht(mt) 2.5, O.C.(mm) 1, Bag size(inch) 21*21 |
| 698 | Bombax ceiba, Straight,healthy,dense, 75 mm calliper, flowering(in season), Min Ht(mt) 2.5, O.C.(mm) 1, Bag size(inch) 21*21 |
| 699 | Cassia javanica, Straight,healthy,dense, 75 mm calliper, flowering(in season), Min Ht(mt) 2, O.C.(mm) 1, Bag size(inch) 15*16 |
| 700 | Cassia renigera, Straight,healthy,dense, 75 mm calliper, flowering(in season), Min Ht(mt) 2.5, O.C.(mm) 1, Bag size(inch) 15*16 |
| 701 | Ficus benghalensis variegated, Straight,healthy,dense, 75 mm calliper, flowering(in season), Min Ht(mt) 2.5, O.C.(mm) 1, Bag size(inch) 21*21 |
| 702 | Jacaranda mimosifolia, Straight,healthy,dense, 75 mm calliper, flowering(in season), Min Ht(mt) 2.5, O.C.(mm) 1, Bag size(inch) 21*21 |
| 703 | Michelia champaca, Straight,healthy,dense, 75 mm calliper, flowering(in season), Min Ht(mt) 2.5, O.C.(mm) 1, Bag size(inch) 21*21 |
| 704 | Millettia peguensis, Straight,healthy,dense, 75 mm calliper, flowering(in season), Min Ht(mt) 2.5, O.C.(mm) 1, Bag size(inch) 21*21 |
| 705 | Millingtonia hortensis, Straight,healthy,dense, 75 mm calliper, flowering(in season), Min Ht(mt) 2.5, O.C.(mm) 1, Bag size(inch) 21*21 |
| 706 | Neolamarckia cadamba, Straight,healthy,dense, 75 mm calliper, flowering(in season), Min Ht(mt) 2.5, O.C.(mm) 1, Bag size(inch) 21*21 |
| 707 | Tabebuia aurea, Straight,healthy,dense, 75 mm calliper, flowering(in season), Min Ht(mt) 2.5, O.C.(mm) 1, Bag size(inch) 21*21 |
| 708 | Tabebuia rosea, Straight,healthy,dense, 75 mm calliper, flowering(in season), Min Ht(mt) 2.5, O.C.(mm) 1, Bag size(inch) 21*21 |
| 709 | Terminalia mantaly variegated, Straight,healthy,dense, 75 mm calliper, flowering(in season), Min Ht(mt) 2.5, O.C.(mm) 1, Bag size(inch) 21*21 |
| 710 | Supply of Ground cover - well developed, min. 0.15m high, in polybag of 8\\"x8\\" size, disease free. All groundcover species shall be evenly balanced to allow equal growth in all directions. Plants shall have fully developed roots and leaves. Rooted cuttings will not be accepted. All plants to be container grown. Supply shall include labour & equipment cost of loading, unloading, transport to site, storage & stacking within site in area protected from dust using temporary agronet, watering & maintenance at stacking area until planted as directed by landscape architect. Dianella caerulea, Bushy,dense from bottom, Min Ht(mm) 250, O.C.(mm) 200 , Bag size(inch) 7*8 |
| 711 | Supply of ornamnetal grass - well developed, min. 0.4m high, in polybag of 8\\"x8\\" size, disease free. All ornamnetal grass species shall be evenly balanced to allow equal growth in all directions. Plants shall have fully developed roots and leaves. single or two stem will not be accepted. All plants to be polybag grown. Supply shall include labour & equipment cost of loading, unloading, transport to site, storage & stacking within site in area protected from dust using temporary agronet, watering & maintenance at stacking area until planted as directed by landscape architectPennisetum rubrum, Bushy,dense from bottom, healthy, Min Ht(mm) 600, O.C.(mm) 300 , Bag size(inch) 7*8 |
| 712 | Pennisetum setaceum, Bushy,dense from bottom, healthy, Min Ht(mm) 600, O.C.(mm) 300 , Bag size(inch)7*8 |
| 713 | Cymbopogon citratus, Bushy,dense from bottom, healthy, Min Ht(mm) 600, O.C.(mm) 300 , Bag size(inch)7*8 |
| 714 | Bambusa guangxiensis,Bushy,dense from bottom, healthy, Min Ht(mm) 1000, O.C.(mm) 200 , Bag size(inch)13*13 |
| 715 | Anti termite treatment by digging holes 300mm deep and 40 mm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge. |
| 716 | Anti termite treatment of lawn area through Chloropyriphose 20% E.C., 5 liter diluted in 995 liters water and applying solution @ 1.00 litre solution per sqm each application in lawn / bed area (two application) i/c cost of chemical) and as per direction of officer-in-charge. |
| 717 | Plantation of Shrub at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cost of plant & water) Item includes all royalty, equipment, labour, loading, unloading, and carriage upto any lead & lift required as directed by landscape architect - Shrubs |
| 718 | Plantation of trees at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cost of plant & water) Item includes all royalty, equipment, labour, loading, unloading, and carriage - Trees |
| 719 | Plantation of groundcover at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cost of plant & water) Item includes all royalty, equipment, labour, loading, unloading, and carriage - Groundccover |
| 720 | Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs,herbs, edge, flower beds, foliages & creepers etc. including hoeing, weeding, pruning, replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter, removal of garden waste, applying insecticide, pesticide & fertilizers (whenever required), top dressing of lawn with good earth and manure and maintenance of other garden related works and operation of MEP with required manpower as directed by officer-in-charge Play grounds. (2.00 Acres=One Mali) As per yard stick. |
| 721 | Transplantation of trees with in a distance of 2 km including excavation around existing tree, pruning of branches, lifting, loading and transportation of existing tree, digging pits for placing tree at new place, adding manure, sand, fertilizer, hormones and bio fertilizer to it. Levelled and neatly dressed and disposal of surplus materials from old existing and new sites to designated place. Each tree should be firmly secured to the stake so as to prevent excessive movement, flooding with water, treatment of roots, rope and gunny bags as per direction of the officer incharge. T&P and all required materials shall be arranged by the contractor and nothing extra shall be paid on this account. Girth of trees beyond 150 cm. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysNov 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender