Public Administrative Department Government Departments Closing in 8 days TDR #58283146

Tender For Construction Of Block Level Stadium In Deogaon Block (With Indoor Hall) In Balangir District.

Issued by Government Departments · Balangir, Odisha
Tender Value
11.60 Crore
Estimated cost
Bid Submission
16 Nov 2026
8 days left
EMD
11.61 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Balangir → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Block Level Stadium In Deogaon Block (With Indoor Hall) In Balangir District.

BOQ

Name of Work:- Construction of Block Level Stadium in Deogaon Block (with Indoor Hall) in Balangir District.
Sl. No. Item Description
1CIVIL WORKEarth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and gravel mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge. (a)Upto 1.5mtr DepthFACILITY BUILDING
2INDOOR HALL
3NATURAL FOOTBALL FIELD
4NATURAL FOOTBALL FIELD DRAINAGE SYSTEM
5UNDER GROUND TANK
6COMPOUND WALL
7RCC DRAIN
8MAIN GATE
9(b)From 1.5mtr to 3.0mtr DepthFACILITY BUILDING
10INDOOR HALL
11UNDER GROUND TANK
12MAIN GATE
13Excavation in all kinds of soil with hydraulic excavator (1 cum capacity) including cutting and loading in tippers, trimming bottom and side slopes ,in accordance with requirements of lines,grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000mATHELATIC TRACK
14KHO-KHO
15KABADI
16VOLLEY BALL COURT
17Filling the Foundation and Plinth, Sides of Foundation, etc. with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge.(a)Ground FloorFACILITY BUILDING
18INDOOR HALL
19NATURAL FOOTBALL FIELD DRAINAGE SYSTEM
20UNDER GROUND TANK
21COMPOUND WALL
22RCC DRAIN
23MAIN GATE
24Disposal of surplus/ excavated materials by mechanical means within 5km. Lead away from the site including cost of all labour , T&P complete as per the direction of the Engineer-in-charge.(a)Ground Floor FACILITY BUILDING
25INDOOR HALL
26Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.(make-premise-BAYER,Paxton-FMC,ozie-KALYANI). FACILITY BUILDING
27INDOOR HALL
28UNDER GROUND TANK
29Providing and injecting chemical emulsion for pre - constructional anti- termite treatment as per IS specification and creating a chemical barrier in bottom and sides of foundation trenches, top- surface of plinth filing junction of walls and floors along with external perimeter of the building expansion joints surrounding the pipes and cables etc. complete using approved quality of chemical emulsion of requisite quantity prescribed by the manufacturer as directed by the Engineer-in-charge including cost o all materials and labour taxes etc. complete. (indemnity bond for warranty for 7 years to be furnished)NATURAL FOOTBALL FIELD
30Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge. (a)Ground FloorFACILITY BUILDING
31INDOOR HALL
32ATHELATIC TRACK
33PAVED PATHWAY
34UNDER GROUND TANK
35COMPOUND WALL
36MAIN GATE
37Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge.(a)From 1.5mtr to 4.5Mtr DepthFACILITY BUILDING
38INDOOR HALL
39UNDER GROUND TANK
40MAIN GATE
41(b)Ground FloorFACILITY BUILDING
42INDOOR HALL
43NATURAL FOOTBALL FIELD DRAINAGE SYSTEM
44COMPOUND WALL
45RCC DRAIN
46MAIN GATE
47Providing and lying Plain Cement Concrete of proportion (1:4:8) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, taxes, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge.ATHELATIC TRACK
48PAVED PATHWAY
49Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.(a)For Beyond 1.5 M to 4.5M DepthFACILITY BUILDING
50INDOOR HALL
51UNDER GROUND TANK
52MAIN GATE
53(b)Ground FloorCOMPOUND WALL
54R.C.C. Plinth Beam(a)Ground FloorFACILITY BUILDING
55INDOOR HALL
56COMPOUND WALL
57MAIN GATE
58R.C.C. Beams, columns, grider and bressmer etc.(a)Ground FloorFACILITY BUILDING
59INDOOR HALL
60COMPOUND WALL
61MAIN GATE
62(b)First FloorFACILITY BUILDING
63INDOOR HALL
64MAIN GATE
65R.C.C. Floor and Roof slab, landing, balconies,Projecting sun shades and chajjas up to 4.3Mtr. Height.(a)Ground FloorFACILITY BUILDING
66INDOOR HALL
67UNDER GROUND TANK
68(b)First FloorFACILITY BUILDING
69INDOOR HALL
70MAIN GATE
71R.C.C. Lintel(a)Ground FloorFACILITY BUILDING
72INDOOR HALL
73(b)First FloorINDOOR HALL
74RCC Staircase(a)Ground FloorINDOOR HALL
75R.C.C. walls and fins including attached pillasters.(a)Ground FloorUNDER GROUND TANK
76(b)First FloorMAIN GATE
77R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc.NATURAL FOOTBALL FIELD DRAINAGE SYSTEM
78RCC DRAIN
79R.C.C. Pre Cast Perforated Cover SlabNATURAL FOOTBALL FIELD DRAINAGE SYSTEM
80RCC DRAIN
81R.C.C. WallNATURAL FOOTBALL FIELD DRAINAGE SYSTEM
82RCC DRAIN
83Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.(a)Ground FloorFACILITY BUILDING
84INDOOR HALL
85NATURAL FOOTBALL FIELD DRAINAGE SYSTEM
86UNDER GROUND TANK
87COMPOUND WALL
88RCC DRAIN
89MAIN GATE
90(b)First Floor FACILITY BUILDING
91INDOOR HALL
92MAIN GATE
93Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. (a)Ground FloorFACILITY BUILDING
94INDOOR HALL
95Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge(a)Ground FloorFACILITY BUILDING
96INDOOR HALL
97Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. (a)Ground FloorFACILITY BUILDING
98INDOOR HALL
99COMPOUND WALL
100MAIN GATE
101(b)First FloorFACILITY BUILDING
102INDOOR HALL
103MAIN GATE
104Providing 6 mm thick Cement Plaster in Cement Mortar of (1:4) to Ceilings of Roof Slabs, Stairs, Landings, Chajja, Shelves, Columns, Beams and Lofts etc. including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing , sundries, T&P etc. complete as per direction of the Engineer-in-charge. (a)Ground FloorFACILITY BUILDING
105INDOOR HALL
106(b)First FloorFACILITY BUILDING
107INDOOR HALL
108MAIN GATE
109Providing 12mm thick cement plaster in cement mortar (1:4) to the surface of half brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge.(a)Ground Floor FACILITY BUILDING
110INDOOR HALL
111Providing 12mm thick Cement Plaster to the Surface of Brick Masonry Wall in Cement Mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge. (Inside Surface)(a)Ground FloorFACILITY BUILDING
112INDOOR HALL
113COMPOUND WALL
114(b)First FloorFACILITY BUILDING
115INDOOR HALL
116Providing 18mm thick cement plaster on external surfaces of brick surfaces in two coats consisting of under layer 12mm thick in CM 1:6 (1 cement : 6 coarse sand) and top layer of 6mm thick cement plaster 1:4 ( 1 cement : 4 coarse sand) mixed with integral water proofing material of including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge.(Outside Surface) (a)Ground FloorFACILITY BUILDING
117INDOOR HALL
118COMPOUND WALL
119MAIN GATE
120(b)First FloorFACILITY BUILDING
121INDOOR HALL
122MAIN GATE
123PLINTH PROTECTIONProviding, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-20 in cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge.(a)Ground FloorFACILITY BUILDING
124INDOOR HALL
125Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.(b)First FloorFACILITY BUILDING
126INDOOR HALL
127MAIN GATE
128Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. (Inside)(a)Ground FloorFACILITY BUILDING
129INDOOR HALL
130(b)First FloorFACILITY BUILDING
131INDOOR HALL
132Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. (Out Side)(a)Ground Floor FACILITY BUILDING
133INDOOR HALL
134(b)First FloorFACILITY BUILDING
135INDOOR HALL
136Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).(a)Ground FloorFACILITY BUILDING
137INDOOR HALL
138(b)First FloorFACILITY BUILDING
139INDOOR HALL
140Providing & Painting two or more coats with Premium Acrylic Smooth Exterior Paint with Silicon Additives of required shade after preparation of surfaces including brushing the suface to make free from foreign materials, sand papering, Priming, etc. including the cost, conveyance, taxes of all materials, cost of all materials, T&P, etc, all complete as per the direction of Engineer-in-Charge. (Make:Dulux/Nerolac/Berger/Asian Paint) (a)Ground FloorFACILITY BUILDING
141INDOOR HALL
142COMPOUND WALL
143MAIN GATE
144(b)First FloorFACILITY BUILDING
145INDOOR HALL
146MAIN GATE
147Supplying, fitting and fixing vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous) of approved make (JOHNSON /RAK / SOMANY/ KAJARIA) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tile including cost of all materials, labour, labour cess, T&P etc. required for the work complete in all respect as directed by the Engineer in charge(a)Ground FloorFACILITY BUILDING
148INDOOR HALL
149(b)First FloorINDOOR HALL
150Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous) of approved make (JOHNSON / RAK / SOMANY/ KAJARIA) as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects as directed by the Engineer in charge.(a)Ground Floor FACILITY BUILDING
151INDOOR HALL
152(b)First FloorINDOOR HALL
153Providing & laying granite stone flooring using 19-20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 in Stair Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade including cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge.(a)Ground FloorFACILITY BUILDING
154INDOOR HALL
155Providing & laying granite stone flooring in Floors and landing using 19-20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (a)Ground FloorFACILITY BUILDING
156INDOOR HALL
157(b)First FloorINDOOR HALL
158Providing & laying granite stone tiles in dado/skirting using 10mm thick granite stone slab of approved quality, colour and size upto 0.4 Sqm as per IS 14223 to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to IS IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(a)Ground FloorFACILITY BUILDING
159INDOOR HALL
160(b)First FloorINDOOR HALL
161Providing & Fixing factory made 100% Solid WPC ( Wood Polymer Composite ) - Door Frame mm x 65 mm Single Rebated, made from Wood Polymer Composite ( Single Extruded Process) material comparising of virgin PVC polymer of K Value 57-60 (Suspension Grade ), Calcium Carbonate and Natural Fibers (Wood Powder/ Rice Husk/ Wheat Husk) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/ cbm & an ISO 9001 - 2015Certified Company, having good screw holding capacity ( Screw Withdrawal strength of (Min. 990 N),Minimum Compressive Strength of 58 N/mm, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof, water / Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners / Hold Fast of reuired dia and lenght,, all as per specifications drawings as directed by the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company.(Make-Green Land / Century/ Alstone)(a)Ground FloorFACILITY BUILDING
162INDOOR HALL
163Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge.(a)Ground FloorFACILITY BUILDING
164INDOOR HALL
165Supplying,Installation of pressed Steel Doors of the specified dimensions and accessories such as hinges,door stopper,tower bolt, door handle ,door closer,dead lock,consedaled flush bolt,Shaft lock,martise lock and vision panel etc. complete as mentioned along with warranty covverage and after sales service etc.inclusive of all costs,taxes,GST,cost of delivery charges ,fixing,fittings and any other invidential charges etc.complete.8 Nos Hinges,2No Door Stoppers,2 No Tower Bolt,1 No martise lock and vision panel (Door Size 2000x2400)(a)Ground FloorINDOOR HALL
1668 Nos Hinges,2No Door Stoppers,2 No Tower Bolt,1 No martise lock(Door Size 1500x2400)(b)First FloorINDOOR HALL
1674 Nos Hinges,12No Door Stoppers,1 No Tower Bolt,1 No martise lock (Door Size 1200x2400)(b)First FloorINDOOR HALL
168Providing and fixing of 12mm thick Clear Toughened Glass Frameless Door With Fittings. (9111198) Unilite Package BTS 75,UL PT 10 with Cover,UL PT 20 with Cover,UL US 10 Luck with Cover and PT 24,Dorma Premium (9137121) H Type Handle 450mm,12mm Clear Toughened Glass with Cutout and Hole, including the cost of all materials, hardware fittings, cost of all labour, conveyance, loading, unloading, T&P, etc, complete as per the direction of Engineer-in-Charge.(a)In all FloorINDOOR HALL
169Supplying and installing Aluminium System - Fixed windows made out of frame dimension of 39mm x 42mm for with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3).Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside Supplying and installing Aluminium System - Openable windows made out of frame dimension of 39mm x 62.9mm & Sash dimension of 46mm x 92mm for with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. orSupplying and installing Aluminium System - Sliding windows made out of frame dimension of 88mm x 40 & Sash dimension of 31mm x 61.5mm for with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. (a)Ground FloorFACILITY BUILDING
170INDOOR HALL
171(b)First FloorINDOOR HALL
172Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge.(a)Ground FloorFACILITY BUILDING
173INDOOR HALL
174MAIN GATE
175Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).(a)Ground FloorFACILITY BUILDING
176INDOOR HALL
177MAIN GATE
178Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces as per section 800 of MoRTH specifications for Road & Bridge works (5th revision) and instruction of Engineer in chargeATHELATIC TRACK
179PAVED PATHWAY
180Finishing with Epoxy paint (Two or more coats) on steel work at all locations prepared and applied as per manufacturer's ecifications including appropriate priming coat(Red Oxide Zinc Chromate) , preparation of surface, etc. complete as per Direction of E.I.C.(a)Ground FloorINDOOR HALL
181Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat & painting Two Coats of Synthetic Enamel Paint of approved steel primer & painting.(a)Ground FloorFACILITY BUILDING
182Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL ).(a)Ground FloorFACILITY BUILDING
183INDOOR HALL
184UNDER GROUND TANK
185(b)First FloorINDOOR HALL
186WATERPROOFING WORKProviding and installing two component acrylic modified cementitious waterproofing coating with Masterseal 551 /Equivalent over roof slab after carrying out pond test on roof slab, filling all defects, saturating the surface, mixing the products and then application in 2.0 mm thickness (1.8 Kg / sqm coverage rate for 1.0 mm thickness) in suitable layers complete in all respect, all materials, tools, plant & labour complete in all respect.Density 1850kg/m³ , Mix ratio (Powder to liquid) 3:1 by weight ,Water penetration Din 1048 1.5 Bar no leakage Potlife @ 25°C 2 hours & @ 40°C 30 minutes,Recoatable: 8-12 hours Elongation >42% (air) & >31% (under water),Tensile strength >20 kg/cm2 ,VOC content (HK prod code P10-17) 0.5 g/L.(b)First Floor FACILITY BUILDING
187INDOOR HALL
188MAIN GATE
189Providing Cleaning the rooftop/sunken surface by using1. Water Proof Coating- Cold applied water based modified polyurethane hybrid elastomeric waterproof membrane at minimum 0.8mm dft in one coat having solids by volume:620/o, Tensile Strength ASTMD412:1.75MPa, elongation ASTMD412>350%, Tear Strength ASTMD624:13N/mm, Adheshion to substrate;1.9MPa concrete, Crack Bridging static/dynamic:2mm ASTM C836, Resistance to water: 10m pressure & SRI ValuelOG for white to be used on the roof including parapet wall surface as per manufacturer direction.2. Coving at right angle- All right angle junctions between floor and wall shall be provided with coving of size 75mmx75mm minimum 15mm thickness in cement mortar 1:4 admixed with FOSROC/SIKA/equivalent chemicals @ 2 litres per 50kg of cement after saturating the surface with water and applying a slurry primer coat.3. Protective Coating- Providing and applying PU Coating FOSROC/SIKA/equivalent on the applied waterproofing surface as per manufacturer direction.(Make:MYK / Fosroc / Sika )UNDER GROUND TANK
190Providing and fixing Glass Reinforced Concrete (G.R.C) Screens in approved size, pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 – 4 Kg per Sq. Ft. and color of M/S UniStone/Samudyam make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens should be made from ‘53 grade’ White Portland Cement manufactured by ‘JK Cement’ or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber, Super Plasticizers manufactured Polymers manufactured and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The material casting should take place in FRP Molds. The fixing of Screens should be ‘Dry fixing’ i.e. to be done with M.S Galvanized Clamps, fixtures and fasteners of Hilti / Fischer.(a)Ground FloorFACILITY BUILDING
191INDOOR HALL
192(b)First FloorFACILITY BUILDING
193INDOOR HALL
194Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.INDOOR HALL
195Gutters -supply and fixing of gutters as per detailed drawings consisting of and aluminum gutter of 2mm in mill finish thickness, fabricated as per the sizes required. Supply and fixing of single skin 2 mm Aluminum gutter, GRADE AA 1100/AA1200 ALLOY with EPDM Expansion joints for every 6.0mtr length, Down take spout of 100- 250 mm at every 10mtr gutter length, & other accessories and welding at joints. The Girth of gutter shall be minimum 1200mm / as advice by the MEP consultant. Feasibility shall be confirmed based on site conditions. INDOOR HALL
196Supply and fixing of “SELF SUPPORTED” SECRET FIX STANDING ROOFING SYSTEM IN 0.9mm THICK AA 3004 ALUMINIUM ALLOY. The general roof-construction shall comprise from bottom to top: Top layer Straight/ curved profile sheeting manufactured from aluminum self-supported standing seam roof system from aluminium alloy AA 3004 H46 (AlMn1Mg1) as specified in BS EN 1396: 2015 material thickness of 0.9mm and in finish of Pvdf consisting of anticorrosive primer of 5 microns, topcoat of PVDF in 20 +/-2 microns with the Total coating thickness as 25 Microns. The coil for the top panel shall have 75 microns transparent protective guard film with the roofing manufacture name printed, This Guard film prevents scratches during roll forming & handling. The standing seam sheet panel of approved make shall be fixed on to the purlin using aluminum ST clips. The head of clips shall be fixed accurately to ensure the roof sheeting expands and contracts freely during thermal movement. The material properties shall be as follows: Ultimate tensile strength minimum 200N/mm2, 0.2% Proof Stress: min 185 N/mm2, Sheets are to be laid to meet the requirements of the building geometry and fixed on aluminum clips. Clip to be fixed with SS 304 screws only. Second Layer -Insulation– One layer of Rockwool India / Roxul insulation of 50mm thickness minimum 60 kg/m³ density. Third Layer –Vapour Control Layer– Double Sided aluminum foil Fourth Layer –Sub Girt- Top Hat and top hat bracket as required in 1.6 mm thick and 2mm thick Galvanised steel hat section to be fixed on trapezoidal Liner sheets Fifth Layer – Trapezoidal Sheets Solid 30-35 /200 Galvalume steel liner 550 MPa, 0.5mm TCT 1000 mm total cover width 30-35mm deep ribs. Purlin Spacing shall be advised by the roofing manufacturer and advised at 1200 mm. The panel shall be manufactured out of Hi tensile pre‐painted Zincalume/Galvalume steel‐AZ150 (min. 150 gms/sq.mt total on both sides) having minimum yield strength of 550 MPa. The finish to the exposed surface of the liner will be polyester coating with film thickness of 15 to 20µm +/- 2 µm. The roofing system manufacturer shall submit the below valid. 1- British Board of Agreement Certificate 2- The Institute of Bautechnic Zulassungbeschield N R -14.1 .181.3- Factory Mutual certificate in India.4. Warranty for 7 years.The rate shall include all accessories for the expansion joint , nut bolts & panels. (The erection / fixing /installation shall be done by specialized / authorized agency as per approved list. The installation team shall be fully trained and approved by the manufacturer. The roofing shall be installed only by approved installers recommended by the roofing manufacturer. Appropriate accessories for Verge, Eave, Ridge shall be used to ensure the weather & water tightness at this point.Vendors - Kingspan Jindal/ Kalzip/ Equivalent as per approval of EICINDOOR HALL
197Aluminum Flashing- Flashings manufactured from aluminum alloy AA 3004 (AlMn1Mg1) as specified in BS EN 1396: 2015 minimum material thickness of 0.9 mm & same finish as panel. Flashing girth to be maximum up to 578mm.INDOOR HALL
198Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).INDOOR HALL
199Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(b) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminiumgrid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board forTesting and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/ IEC 17025.INDOOR HALL
200Providing openable side / top hung vision glass panels (IGUs) in structural glazing including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.INDOOR HALL
201Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick hard coated low emmissivity glass, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and Firstary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“ (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.INDOOR HALL
202Supply & Installation of BADMINTON WORLD FEDERATION (BWF) approved Wooden Sports flooring system \\"AIRFLEX SMASH®\\" that should be compliance with the Area elastic with total thickness of 75 mm comprising of 20mm Top Solid Wood followed by 45mm solid wood runner and 10mm Power Rubber Pad. Product top finish to have square Edge & UV Prefinished with Back Side Coating (Polished used of Klumpps from Germany which is sweat and saliva resistance according to DIN 53160- 1/2) to have higher polish life. The wooden flooring should have Eco-friendly manufacturing process with 100% sustainable and manageable plantation resource with raw material.' The product should have been produced through Kilned and dried technology to maintain suitable moisture content. The top wood should necessarily be sourced from 100% sustainable resource and should have with prefinished including sanding & polishing. Structure of system should be 10mm thick rubber pad, 45mm thick pine runner with the width of 70mm, followed by the 20mm top flooring. Top wood plank sizes should be 20mm Thick, 130mm Wide and 1830mm length. Runners to be placed at a distance of 305mm C/C. Entire system should follow norms with the EN 14904(06/2006) and technical parameters for the product should have friction of 95 according to EN 13036-4, Shock absorption of 45% according to EN 14808, Vertical deformation should be 1.8mm according to EN 14809 and Vertical ball rebound should be 99% according to EN 12235”INDOOR HALL
203Providing and installation of Impact sports 65 Vinyl Sheet Flooring manufactured by Tarkett with a nominal thickness of 6.5 mm as per EN ISO 24346 and width of 2m as per EN ISO 24341. Impact sports 65 shall conform to EN 14001. The wear surface shall haveTop Clean XP™ treatment. Impact sports 65 shall have Resistance to wear as ≤1g as per EN ISO 5470-1, Resistance to impacts as per EN 1517 with no degradation, Tested for rolling loads as per EN 1569 and found compliant, Reaction to Fire as per Class Cfl-S1 as per EN 13501-1, tested for Resistance to Indentation and found compliant as per EN 1516 norms, Vertical Deformation value of P1 as per EN 14809, Shock absorption value of P1 as per EN 14808, Friction compliant as per EN 13036-4. The product should provide acoustical improvement of less than or equal to 65 dB - Class A as per EN 16205. The product does not contain Pthalate based plasticizer and emission rate of VOC is very low, measured after 28 days. TVOC and formaldehyde emissions are below 10µg/m3. It is 100% Recyclable with 23% recycled content and 100% REACH compliant.INDOOR HALL
204Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.ATHELATIC TRACK
205KHO-KHO
206KABADI
207VOLLEY BALL COURT
208PAVED PATHWAY
209NATURAL FOOTBALL FIELD
210Construction of granular sub-base by providing Close graded Granular sub base Grading-III material as per table 400-1, spreading inuniformlayers with motor grader on prepared surface,mixing by mix in place method with rotavatorat OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&HSpecifications for Road& Bridge works (4th Revision)ATHELATIC TRACK
211KHO-KHO
212KABADI
213VOLLEY BALL COURT
214Construction of granular sub-base by providing Grading VI close graded Material, spreading in uniform layers with motor grader on prepared surface, mixing by place in method rotavator at OMC, and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 PAVED PATHWAY
215Supplying, stacking and spreading of good earth at site within initial lead including royalty and carriage transporting to site, spreading, grading to required slope and compacting to meet requirement.ATHELATIC TRACK
216KHO-KHO
217KABADI
218VOLLEY BALL COURT
219Supplying, stacking, laying and compaction of a consolidated layer, 50 mm thick, of graded material of 4.75 mm to 2.36 mm mixed with cohesive material for stability and grip, etc., as per the direction of the engineer-in-charge.ATHELATIC TRACK
220KHO-KHO
221KABADI
222VOLLEY BALL COURT
223Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in base course on well prepared surface and compacting with vibratory roller to achieve the desired density.PAVED PATHWAY
224Supplying and fixing of 60mm thick cement concrete interlocking paver block of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018 as per the direction of the engineer-in-charge.PAVED PATHWAY
225Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect confirming to IS 5758:1984 as per the direction of the engineer-in-charge.ATHELATIC TRACK
226PAVED PATHWAY
227Kho Kho Court Pole. Supply & Installation of Kho Kho Pole,Two rigid poles of 1.20 m height from ground level, Heavy Duty 4 inch Dia Smooth & Round Steel Uprights, No sharp edges to prevent injury.
228VOLLEYBALL POLE Supply of adjustable, internal winding poles with net including sleeves and cover for Volleyball court make Freewill / SPORTTECH/ uphos
229Providing and Laying & Compacting 4-9mm stone aggregate Spreading in uniform layersNATURAL FOOTBALL FIELD
230Supplying and stacking of root zone sand as per USGA standard at site including royalty and carriageNATURAL FOOTBALL FIELD
231Supplying and stacking at site Organic matter (turf booster/equ.) from approved source.NATURAL FOOTBALL FIELD
232Supply and Mixing basal fertilizer in the required proportion specified or directed by the Officer-in-charge.NATURAL FOOTBALL FIELD
233Providing and dibbling of good quality lawn of the specified species in lawn area, with clods broken completely, and removal of debris and unwanted materials and final saping to achieve desired levalBermuda TIFWAY419 /Improved seeded VarietyNATURAL FOOTBALL FIELD
234Providing and laying in trenches Upvc pipes conforming to IS 4984 1995 and specials of following outside diameter and class-1 to class-3 and jointing including testing as per specification complete. (Earth work in trenches to be measured and paid fo separately)10Omm Upvc corrugated perforated pipeNATURAL FOOTBALL FIELD
235160mmUPC Plain pipeNATURAL FOOTBALL FIELD
236Supplyingand laying of Geotextile (For Trenchs) 150 GSMNATURAL FOOTBALL FIELD
237Providing and laying 450 mm dia. R.C.C. pipe non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:3 (1 cement : 3 fine sand) including testing of joints etc. complete :NATURAL FOOTBALL FIELD
238Design, Supply, Installation, Testing and Commissioning of Fully Automatic Underground Pop-up Sprinkler Irrigation System complete for the Football-cum-Cricket Field, as per the approved drawings, manufacturer's specifications, site conditions and the directions of the Engineer-in-Charge. The scope shall include preparation of hydraulic design and shop drawings; supply, installation, testing and commissioning of the complete irrigation system including uPVC pipelines, pop-up sprinklers with swing joints, automatic controller,solenoid valves, manual valves, valve boxes, disc filter, pumps (1 Working + 1 Standby, minimum 7.5 HP each), control panels, cables with conduits, fittings, clamps, NRVs, supports, excavation, backfilling, thrust blocks, flushing, trial run and all other accessories, consumables, labour, tools, testing and incidental works required for satisfactory and trouble-free operation of the irrigation system, complete in all respects. Approved Makes: -uPVC Pipes: Supreme / Finolex / Astral Pop-up Sprinklers, Controller, Solenoid Valves,Rain Sensor & Irrigation Accessories: Toro (USA) / Rain Bird (USA) / Eqv. Swing Joints: Toro / Rain Bird / Eqv. PP/PVC Service Saddles & Ball Valves: Supreme (Italy) / SAB / Plasson / Eqv. Air Release Valve, QCV & Brass Fittings: Harit / Jain / Eqv. Valve Boxes: Pimtas / Eqv. Pumps: Grundfos / Xylem / Eqv. Disc Filter: Amaid / Azud / Eqv. Control Cables: Macrotherm / Paige / Eqv. Waterproof Wire Connectors: 3M / Toro / Eqv. NATURAL FOOTBALL FIELD
239Supplying all materials, labour, T&Pand providing, fittingand fixing submersible pump with squirrel cage induction type submersible type submer sibleele ctricmotor torunon3phase/ 1phaselinevoltagerangingfrom320volt to450voltconformingto IS: 8034/89 with following specifications with suitable control panel, jointingwithGI/PVC/HDPEpipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxesetcall completeasper specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make)1H.P.Singlephase/ threephase3stage headrengeof20to35mtrwithdischargecapasity145to110L.P.MWithoutletdia25mm (keeping 100 standby) UNDER GROUND TANK
240DOL control panelUNDER GROUND TANK
2412.50sqmm flat cableUNDER GROUND TANK
242Football Goal Post (All As per FIFA Requirement for premier Tournament) Supply and installtion of Uprights & Crossbars made from 102mm x 112mm reinforced aluminium with double recess for flush fitting fixings. Reinforced welded aluminium corner joints for improved aesthetics and superior strength, with laser cut internal fixing for exceptionally accurate joints. Injection moulded toughened nylon net clips that won't deteriorate over time. Lock-in T-bar to allow for easy storage of the bottom net bar against upright for pitch maintenance. Reinforced net support system prevents bowing under intense tension. New, heavy duty ratchet winch and webbing strap allows for high-class net shape with the inclusion of a failsafe wire providing 100% security during matches. Lock-in bottom net bar 38mm diameter aluminium bar with ground secure key lock mechanism complete with 4 sockets and whitePolyester powder coated of size 7.32m x 2.44m Set = 2 Goals with 4 x 460mm deep sockets, and net etc. all complete as per FIFA Specification. MAke :- Freewill/ harrod/ shelde NATURAL FOOTBALL FIELD
243Supply and Installation of Corner Flag (1 set=4Nos)NATURAL FOOTBALL FIELD
244Supply of Players dugout structure fabricated from MS tube having minimum dimension of 50 x 50 mm Square Tube detachable framework with matt finish. The height of the dugout will be 2.05 meter at front side, 0.4 Mtr Radius curved roof and 4.9mtr length The seating capacity will be of 10 players. The structure will be covered with 3mm thick transparent or colored polycarbonate sheet on top and two sides.The Structure is Provide with HDPE Blow Molded Seat FI1002 Double-wall hollow blow mold bucket type seat having minimum dimensions as 500 mm side length x 440 mm front width x 420 mm rear height in one piece of HDPE having minimum shell thickness of 3 mm on each wall. Minimum seat density of 0.95 gram/cm3, weight of plastic chair should not be less than 2.65 kg. Chair should withstand in high temperature not less than 50°C with ultraviolet stabilizer and color fastness, having ergonomic design, the chair should be fixed with Metal Inserts moulded inside seat to connect seat with Galvanized pipes 32mm OD tube and 2 mm thickness running under the chairs. The pipes are resting above the structure. Water should not accumulate on chair. Chair should have a warranty of 2 years against significant colour fading and 3 years against breakage due to manufacturing defects. Chair Plastic Part should have been tested with xenon –Arc exposure Test as per ISO 4892-2:2013, Cycle-1.The Grey Sale Rating should be (GSR): > 4, Delta Δ E: < 3 NATURAL FOOTBALL FIELD
245Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metreCOMPOUND WALL
246Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.COMPOUND WALL
247Providing and fixing Neelgiri/Mexican grass turf with earthy 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light, watering with sprinkler and maintenance for 30 days or more till the grass establish properly as per direction of officer incharge.LANDSCAPING
248Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).
249Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment).
250Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) .Screened through sieve of I.S. designation 20 mm
251Screened through sieve of I.S. designation 16 mm
252Screened through sieve of I.S. designation 4.75 mm
253Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
254Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.
255Providing and stacking of Magnolia grandiflora of height 150-165 cm. in poly bag of size 25 cm as per direction of the officer-in-charge.
256Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge.
257Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in poly bag of size 25 cm as per direction of the officer-in-charge.
258Providing and stacking of Dalbergia sissoo (Seasam) of height 120-135 cm. in poly bag of size 25 cm as per direction of the officer-in-charge.
259Providing and stacking of Alstonia scholaris of height 150-165 cm. in bag of size 25 cm as per direction of the officer-in-charge.
260Providing and Stacking of Anjeer of height 75 cm to 90 cm in poly bag of size 25 cm as per direction of the officer-in-charge.
261Providing and stacking Iresine herbstii, of height 25 cm to 30 cm., full of branches well developed in 15 cm size of Earthen Pot / Plastic Pot and as per direction of the officer-in-charge.
262Providing and stacking Duranta Golden, having ht. 15 cm to 20 cm bushy shape with fresh and healthy leaves in 15 cm size of Earthen Pot/ Plastic Pot and as per direction of the officer-in-charge.
263Providing and stacking of Murraya exotica of height 45-60 cm. in poly bag of size 15 cm as per direction of the officer-in-charge.
264Providing and stacking of Tecoma gaudichaudi of height 90-105 cm.,bushy in big size HDPE bag as per direction of the officer-incharge.
265Providing and stacking of Cestrum nocturnum (Raat ki Rani) of height 60-75 cm.with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge.
266Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts(cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 90 cm dia, and 90 cm deep
267Holes 45 cm dia, and 45 cm deep.
268Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, edge, flower beds, foliages, creepers etc. including hoeing,weeding pruning replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter, removal of garden waste, applying insecticide, pesticide & fertilizers(whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide, Pesticide, lawn mover and brush cutter with fuel & other T & P material/ articles shall be provided by the department.)
269Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. completeMAIN GATE
270Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) PProviding, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade CLASS B1 mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.MAIN GATE
271E.I. WORKCOMMON FACILITY CENTERRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG /BEC /Precision/ Norpak/ Anchor/ Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/ legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make of Modular GI box - Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)NB:All the electrical,Fire fighting,HVAC,ELV drawings,LUX Level design of the arena lighting, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. GROUP-A
272GROUP-B
273GROUP-C
274Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
275Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION)
276Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
277Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
278Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
279Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
280Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
281Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5)
282Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB) (4X6+2X4)
283Supply, delivery, installation & testing of Modular G.I. box 18 SWG Sheet ISI marked with Modular base & cover for 2 moudle tv socket outlet.Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)
284Wiring to Telephone Socket Outlet from Junction Box with 0.5 mm2 Four Pair Copper Conductor Telephone Wire run inside prelaid PVC Conduit complete including termination, testing etc complete as required and as per Direction of Engineer-In-Charge.
285Supply, delivery, installation and testing of TV Antenna Wires RG6 in PVC Pipe and making good the damages caused complete as required and as per Direction of Engineer-In-Charge.
286Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
287Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . In case, the distance between ODU and IDU exceeds 3 mtr, then only the item of copper pipe shall be executed without any joint and equivalent mtr shall be deducted from the copper pipe item.1.5 TR with 5 Star BEE Rating (LG-AS-Q20JWZE/ O General-ASGG18CGWA-B/ Daikin-FTKU50XV16)
288Supply,installation of hard/soft ISI marked copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job.
289Supply,installation & fabrication of MS base frame for outdoor unit and other nesessary material to complete the job.
290Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV)20 MM
29125 MM
292Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
293Supply, Installation, Testing and Commissioning of Duct mounted Single skinned Circular Inline Centrifugal Fan for Toilet Ventilation with direct driven Backward-curved impellers.The Fan has external rotor motor suitable for 1~, 230V, 50 Hz power supply. MAKE - SYSTEMAIR/ GREENHECK/ ELTA/Airflow1500 CFM @ 15mm MMWG static pressure
294Supply & Fixing of Air Distribution Duting fabricated with Class VI GI Sheet(180 GSM) Complete With Supports, dampers, guiding vanes, access doors, MS Angle, Fire inhibiting gaskets, Nuts, bolts and all oyher accessories in accordance with approved drawing and the Specification. (Make:- Jindal/ Sail/ Tata)22 gauge (0.80 mm thickness)
29524 gauge (0.63 mm thickness)
296Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire
297Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(fan Regulator compatible) .
298S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)
299SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
300SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)
301Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
302Supply, Installation, Testing & Commissioning of of IP65 (10-12)w Bollard Fixture with Body made of Extruded Aluminium /Mild steel Pole & PDC Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized Injection Moulded Diffuser for Soft and even light distribution. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 4kV Internal and 10kV External SPD of IP67) THD<10%. CRI>70, PF>.95. CCT - 5700/4000/3000K.Impact Resistance IK05.Operating Voltage Between (100-275)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved.Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge. Make-K-LITE/Philips/LT/PANASONIC/Havells/Bajaj/Crompton/Wipro
303Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 /ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
304Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years
305Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year.
306Supplying and fixing 63 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year.
307Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year
308Supply ,installation ,testing & commissioning of 5KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer of 1ph in put to 1 ph output,230V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 26AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) , as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. for services building
309Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (with charcoal and salt) as required and as per direction of Engineer-in-charge.
310Providing and fixing 6 swg GI wire on surface or in recess for loop earthing as required and as per direction of Engineer-in-charge..
311Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
312S/I/T&Commissioning of LT indoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA..In commer--01 number of 125 Amps MCCB 25 KA TMR based, Ics=100%Icu , 01 number of 125 Amps 4P onload type Changeover with both source ON/OFF indication (Make-Siemens/Schneider/ABB/LEGRAND)Busbar- 04 numbers of 200A Aluinuium busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (ii) 03 nos 63A 4P MCB 10kA,C series , 03 nos 63A DP MCB 10kA,C series, 02 nos 32A DP MCB 10kA,C series LIGHT BDB AC IDU BDB/LIGHT BDB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Instrument- (i) 3 numbers phase indicating lamp for R,Y,B inndication for both the source with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)..(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB/Legrand).(iii)01 set of 3 ph digital type Ammeter(0-200)A(Make-Siemens/Schneider/ABB/Legrand) with CTs 200/5A 3 nos class 1 type(Make-Siemens/Schneider/ABB/Legrand)
313Supplying and fixing 32amps rating,double pole mcb type changeover 240 volts, C series,10KA breaking capacity, of Make-LEGRAND/ Siemens/ Schneider/ABB the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. for UPS Outgoing )
314Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 50 sq mm
315Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x50 sq mm
316Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
317Supply installation of high-voltage insulating mat has a thickness of 3.0 mm, rated for maximum use voltage of 33 kV. It withstands an AC proof voltage of 36 kV and an AC dielectric strength of 65 kV, with maximum leakage current limited to 10 mA. Minimum insulation resistance (5000V megger) is 1,00,000 MΩ. Tensile strength is minimum 15 N/mm², with 250% minimum elongation. After 168 hrs aging at 70±1°C, retention is minimum 75% (tensile & elongation); after 48 hrs immersion in acid/alkali/diesel/oil, retention is minimum 80%. The mat offers low-temperature resistance and flame retardance, made of synthetic elastomer, conforming to IS 15652. complete as per direction of Eng-in-charge.(Size-10mx1m) make : mandelia insulation and transmission co./Duratuf/Raychem/Vardhman
318Supply and fixing of Danger Board.
319Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room.
320Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/Supremex/ Ceasefire/Flameklog/Kalpex .4.5 kg capacity
321Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/Supremex/ Ceasefire/Flameklog/Kalpex.6 kg capacity
322SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit.
323SITC of Cat6 I/O with single Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
324SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit
325SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length)
326SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(2 mtr length)
327SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit
328SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit
329SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit
330SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear
331SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 380W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP, Netgear
332SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand
333SITC of 5MP IP Bullet/Dome Camera with inbuilt microphone, equipped with 1/2.7\\" Progressive Scan CMOS image sensor and 3.6/2.8(for dome) mm fixed lens, supporting a resolution of 2592 × 1944 or higher. The camera shall provide IR illumination up to 30 meters and an approximate field of view of 79° (H)/97(for dome), 56°/70(for dome) (V), and 106°/128( for dome) (Diagonal). Minimum illumination shall be 0.003 lux @ F1.6 (AGC ON) with support for WDR (120 dB). The camera shall support video compression formats such as H.265+, H.265, H.264+, H.264 and MJPEG, with multiple streaming capability including main stream up to 5MP @ 30 fps, sub-stream up to 1080p @ 30 fps, and additional third stream. The camera shall support intelligent analytics such as human and vehicle detection, perimeter intrusion detection, line crossing detection, object detection, heat map, crowd density detection, queue length detection, and rare sound detection. The device shall support motion detection with multiple configurable zones and network protocols including TCP/IP, HTTP, DHCP, RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS and SFTP, and shall be ONVIF compliant (Profile S/G/T). The camera shall include micro SD card slot up to 256 GB/512 GB( for dome), privacy masking, ICR auto day/night switching, and support 12V DC or PoE power supply. The housing shall be metal body with IP67 weatherproof protection, suitable for outdoor installation. The product shall comply with NDAA requirements and shall be certified with STQC, BIS, CE, FCC and RoHS. Make-Honeywell Value series/Pelco/Axis/Bosch
334SITC of 5MP IP Varifocal Bullet/Dome Camera with 1/2.7\\" Progressive Scan CMOS image sensor and motorized varifocal lens (2.8–12 mm), supporting a resolution of 2880 × 1620 or higher. The camera shall provide IR illumination up to 50/30( for dome) meters and a variable field of view approximately 107°–34° (H), 55°–19° (V), and 134°–38° (Diagonal). Minimum illumination shall be 0.004 lux with advanced imaging features including Starlight technology and WDR (120 dB) for improved low-light performance. The camera shall support multiple video compression formats such as H.265+, H.265, H.264+, H.264 and MJPEG, with multi-stream capability including main stream up to 5MP @ 30 fps, sub-stream up to 720p @ 30 fps, and an additional third stream. The camera shall support motion detection with configurable zones and event triggers including motion detection, video tampering, scene change, network disconnection, and IP conflict. The device shall support intelligent video analytics such as face recognition, human and vehicle detection, perimeter intrusion detection, line crossing detection, object detection, heat map, crowd density detection, queue length detection, and rare sound detection. It shall support network protocols including TCP/IP, HTTP, DHCP, , RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS and SFTP, and shall be ONVIF compliant (Profile S/G/T). The camera shall include micro SD card slot up to 256 GB/512 gb( for dome), alarm I/O (1/1), audio I/O (1/1), privacy masking, and ICR auto day/night switching. The camera shall support 12V DC or PoE power supply and be housed in a metal weatherproof enclosure with IP67 protection, suitable for outdoor installation. The product shall comply with NDAA requirements and be certified with STQC, BIS, CE, FCC and RoHS or equivalent. Make-Honeywell Value series/Pelco/Axis/Bosch
335SITC of 64CH project series Network Video Recorder, Should support Resolution:- greater than equal to 12 MP IP Camera, Network Bandwidth incoming 640 Mbps and outgoing 640 Mbps for access, support for H.265+/H.265/H.264 encoding format streaming access and decoding output, Recording play back quality: 16 ch play back simultaneously, Recording resolution up to 12MP, Recording mode: support manual, Auto, Motion detection, Alarm, trigger record mode, Operation way: Mouse, local Login: Username and password, Recording storage: Local HDD, network, Video output: HDMI/VGA/TV, Support min. 8 SATA HDDs , Each port supports min. 18TB HDD(Enterprise class),support-RAID0, RAID1, RAID5, RAID6, RAID10,Support dual Gigabit Ethernet ports,Supports 4 HDMI outputs,Alarm Input/out:16 in /4 out ,Audio:1 in / 1 out ,Supports intelligent analytics such as Licence plate detection,Face Recognition,Human&Vehicle Detection,Perimeter Intrusion Detection,Line Crossing Detection, Cross Counting,Stationary Object Detection,Heat Map,Crowd Density Detection,Queue Length Detection, Rare Sound Detection, product must comply with NDAA complaince, Certification: BIS,CE,FCC,ROHS. Make-Honeywell value series /Pelco/Axis/Bosch
336Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba
337SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony
338INDOOR HALLRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make of Modular GI box - Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)NB:All the electrical,Fire fighting,HVAC,ELV drawings,LUX Level design of the arena lighting, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. Group-A
339Group B
340Group C
341Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
342Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
343Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION)
344Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.(Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION)
345Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
346Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
347Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
348Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
349Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB) (4X6+2X4)
350Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
351Supplying and fixing 63 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABBSB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year.
352Supplying and fixing 25 Amps rating,C series,10KA breaking capacity, DP, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The MCB should be Replacement Warranty will be 1 year.
353Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year.
354Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
355SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)
356Supply, Installation, Testing & Commissioning of of IP65 (10-12)w Bollard Fixture with Body made of Extruded Aluminium /Mild steel Pole & PDC Aluminium Housing for Optimal thermal Conductivity. With UV Stabilized Injection Moulded Diffuser for Soft and even light distribution. High Efficiency Driver with necessary safety Protection against Short Circuit, Miswiring,Over Voltage and Surge Protection of upto 10kV ( 4kV Internal and 10kV External SPD of IP67) THD<10%. CRI>70, PF>.95. CCT - 5700/4000/3000K.Impact Resistance IK05.Operating Voltage Between (100-275)V. Avg life of 50,000 Burning [email protected] the light fixture and the Driver Should be BIS Approved.Before final procurement, the final design shall be approved by the concerned client and Engineer-in-charge. Make-K-LITE/Philips/LT/PANASONIC/Havells/Bajaj/Crompton/Wipro
357SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
358Supplying an fixing of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/ LT/ Havells / Philips/ Wipro/ Crompton/ Bajaj) . The luminaire must be Replacement Warranty will be 5 years.
359Supplying, installation, of 100W WALL Mounted industrial metallic fan of 450 mm sweep 1440 rpm, 150 cum/min. aluminium blade , 100% copper winding, 3 speed control (Make- Havells/Crompton/Usha/Bajaj /Orient) of wall fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
360Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Bajaj/Orient ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
361Supply, Installation, Testing and Commissioning of Duct mounted Single skinned Circular Inline Centrifugal Fan for Toilet Ventilation with direct driven Backward-curved impellers.The Fan has external rotor motor suitable for 1~, 230V, 50 Hz power supply. MAKE - SYSTEMAIR/ GREENHECK/ ELTA/Airflow1500 CFM @ 15mm MMWG static pressure
362Supply & Fixing of Air Distribution Duting fabricated with Class VI GI Sheet(180 GSM) Complete With Supports, dampers, guiding vanes, access doors, MS Angle, Fire inhibiting gaskets, Nuts, bolts and all oyher accessories in accordance with approved drawing and the Specification. (Make:- Jindal/ Sail/ Tata)22 gauge (0.80 mm thickness)
36324 gauge (0.63 mm thickness)
364Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire
365Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(fan Regulator compatible) .
366S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)
367Supply, Installation, Testing and Commissioning of Linear LED SPorts light with Max system power of 80W , CCT 5700K +/-355K as per ANSI , CRI>80, SDCM<3 , with Minimum delivered lumen of >11,500 lumens . The fixture housing must be Made of extruded Aluminium housingfor better thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have minimum Ingress protection of IP66 and Impact Resistance of IK08. The fixture should be equiped with stabilized Injection moulded special PC diffused optics ensuring low glare & best in class uniformity( Glass cover not allowed) . Luminaire housing should carry OEM's logo embossed / engraved (no stickering is allowed). the Length of Luminaire should be between 900mm-1000mm or as per approved design . The luminaire must have Integral high efficiency electronic thermally isolated constant current IP66 driver with operating voltage range of 90-305V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of : DM 4kV, CM 6kV and upgraded with integrated External IP67 protected SPD of 20KV/10KA surge protection .Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers. All supporting documents like Technical data sheet of Luminaire & Driver, LM79 test reports including test reports photometry , TTC, IP, IK, Vibration and salt spray test from third party NABL accredited Laboratory. LM80 from LED OEM .BIS of the Luminaire should carry the Own factory address of OEM, vendor facilities are not acceptable.(5 years warranty)All arena light shall be supplied from UPS DB. Make- Philips/ Lighting Technologies/ Schréder
368SITC of high-quality integrated LED Flood Light with a minimum system lumen of 26K Lm or higher and nominal efficacy of 130 lumen/watt or higher. CCT of 5700K with SDCM of < 5 and CRI >=80. The housing should be of pressure die-cast aluminum (ADC12) to with stand extreme environments. The luminaire should come with with PF > 0.95, THD<10%, Lifetime of 50K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have internal surge protection of 4kv and 10 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2.The luminaire should be of Class B Serviceability. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The High power LED used in the luminaire shall be SMD type. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The fixture shall have warranty of 5 years. LM79,LM80,Type test report, BIS certificate of driver and luminaire, TDS of luminaire and driver,LUX level design to be done as per following specifications: average lighting level shall be >=500 LUX ,min to average shall be >=0.7, min to max shall be >=0.5 and shall be approved by SEEC(R&B) and CE,Bdgs,O,BBSR before final procurement.(4 Nos. for each pole) Only sport series flood light will be accepted.Make- Philips/ Lighting Technologies/ Schréder
369Supply of 9 mtr long hot dip galvanized Octagonal pole with channel bracket (for mounting at least 6nos. or more of flood light as per final lux level design) manufactured from HT steel having base dia if 210 mm & top dia 90 mm or more and sheet thickness of 4 mm or more and 4 Nos. M30X850mm EN8 Grade foundation bolt. The octagonal pole shall be suitable to withstand 200 KM/HR or more wind speed by considering the weight & wind expose area . All accessories included like anchor plate, foundation nuts & bolts including required size of control cable from starter panel to each light . Make:- Bajaj/RR Ispat/Utkarsh /Valmont /Vakrangee
370Excavation in all types of soil for foundation pit size 1.4m×1.4m×1.8m depth includingshoring/strutting if required, stacking excavated material and disposal within 50m lead Plain Cement Concrete M10 (1:3:6) for PCC bed below footing, 100 mm thick, includingmixing, placing and curing (Size: 1.5m×1.5m),Reinforced Cement Concrete M25 (fck=25 N/mm², Fe500 TMT rebar) for RCC footing 1400×1400×600 mm, including formwork, placing, vibrating and curing ,Reinforced Cement Concrete M25 for RCC pedestal 650×650×1200 mm height,including formwork, placing, vibrating and curingFe500 TMT reinforcement bars for footing and pedestal (T12 @ 150 c/c both ways bottom mat, 8T12 vertical pedestal bars, T8 @ 150 stirrups) including cutting, bending, binding and placing Backfilling around foundation with excavated/selected earth in 150 mm layers, watered and compacted to 95% MDD using plate compactor Cement mortar (1:3) grouting under base plate after pole erection, finishedneat and flush with pedestal top.The foundation design should be approved from concerned SE/CCE(Civil wing) before execution of the work.
371Supply ,installation ,testing & commissioning of 10 KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 1 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 42AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) , as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. for INDOOR HALL building
372Main panel :S/I/T&Commissioning of LT OUTdoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 50X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 50 kA/pole 3P+N type 1+2 SPD with 600A HRC backup fuse.All feeders shall have ON/OFF/TRIP indication.Mandatory provision of Cable alley is to be given.In commer- 01 no 400 A 4P MCCB 36kA LSIG Microprocessor release ,Icu=100%Ics ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) Busbar- 04 numbers of 500 Amps aluminium busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 04 nos 125 A 4P TMR MCCB 25kA with Ics=100%Icu01 nos 250 A 4P MCCB 25kA TMR MCCB 25kA with Ics=100%Icu Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 , Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of 0-400Amps Ammeter with CTS.(DIGITAL)(Make-Legrand/ABB/schneider/Siemens)(iii) 01 set of 0-500 voltmeter .(DIGITAL)(Make-Legrand/ABB/schneider/Siemens)Make of SPD-Legrand/ABB/schneider/Siemens/obo/dehn
373CONTROL PANEL:S/I/T&Commissioning of LT OUTdoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA.All feeders shall have ON/OFF/TRIP indication.Mandatory provision of Cable alley is to be given.In commer1- 01 no 125A 4P MCCB 25 kA tmr ,Icu=100%Ics ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) with125A 4P Manual changeover In commer2- 01 no 125A 4P MCCB 25 kA tmr ,Icu=100%Ics ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) with125A 4P Manual changeover Busbar- 04 numbers of 300 Amps Aluminium busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 12 nos 100-63 A 4P MCCB 16kA TMR with Ics=100%Icu ,02 nos 63/40 A 4P MCB 10KA C series, 02 nos 63/40 A DP MCB 10KA C seriesInstrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 02 set of 0-300Amps Ammeter with CTS.(DIGITAL)(Make-Legrand/ABB/schneider/Siemens)(iii) 02 set of 0-500 voltmeter .(DIGITAL)(Make-Legrand/ABB/schneider/Siemens)Make of SPD-Legrand/ABB/schneider/Siemens/obo/dehn(iv) 02 sets of 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA
374INDOOR LIGHT PANEL FOR ARENA :S/I/T&Commissioning of LT OUTdoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed..All the incomers shall have 20kA 1P+N type 2 SPD with 63 A 2P MCB, C series, 10 kA.All feeders shall have ON/OFF/TRIP indication.Mandatory provision of Cable alley is to be given. Incomer: 32 A DP MCB (10 KA) , C series Bus bar: 2 numbers of 100Amps copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. VMR with microprocessor based overvoltage,over current protector OUTGOING : 26 NOS 6 A DP MCB 10KA , C series Instruments: Instrument- (i) 01 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication(Make-Legrand/ABB/schneider/Siemens) below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge..MAKE OF MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FormulaMake of MCBs- LEGRAND-DPX3/Siemens-Betaguard-Schneider-Acti-9/ABB SB200
375EXTERNAL CABLING PANELSSUB PANEL:S/I/T&Commissioning of LT outdoor floor mounted doubledoor CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA.All feeders shall have ON/OFF/TRIP indication.Mandatory provision of Cable alley is to be given. Incomer:63 A 4P MCCB (16 KA) with adjustable thermal setting Ics = 100% of Icu Bus bar: 4 nos. 100A aluminum busbar duly sleeved Instruments: 1 set.LED type phase indicating lamps with control fuses Outgoing :12 Nos 6A DP MCB. (10 KA), C series complete as per the direction of Engineer-in-chargeMAKE OF MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FormulaMake of MCBs- LEGRAND-DPX3/Siemens-Betaguard-Schneider-Acti-9/ABB SB200
376Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV)20 MM
37725 MM
378Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.3.5 core x 240 sq mm Aluminium armoured Cable.(FOR control /MAIN PANEL)
3793.5 core x 70 sq mm Aluminium armoured Cable.(FOR dg)
3803.5 core x 50 sq mm Aluminium armoured Cable.(FOR OUTDOOR LIGHT PANEL)
3813.5 core x 25 sq mm Aluminium armoured Cable.(for INDOOR & SUB OUTDOOR light)
382Supply and laying of 4 core x 10 sq mm Aluminium armoured Cable.(for VENTALLATION )
383Supply and laying of3 core 2.5 sqmm Flexiable copper cable (for Hall light and flood light)
384Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.3.5 core x 240 sq mm brass double compression gland and aluminium lugs
3853.5 core x 70 sq mm brass double compression gland and aluminium lugs
3863.5 core x 50 sq mm brass double compression gland and aluminium lugs
3873.5 core x 25 sq mm brass double compression gland and aluminium lugs
388Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
389Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
390Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
391Supplying,installation,testing & commissioning Of Earthing with copper earth plate 600 mm x 600mm x 3.18 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge.
392Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
393Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required including the cost of material ,labor T & P as required as EIC.
394Supplying,fixing of hot dip galvanized powder coated GI perforated cable trays with cover having horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
395Supplying,fixing of perforated cable trays with horizontal & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
396Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
397Supply installation, testing and commissioning of single piece long casing (motor should completely be accommodated inside the fan casing, multi piece casing are not acceptable) Tube Axial Fan in MS with powder coated / GSS, Al impeller with adjustable blade angles (Manually Adjustable at Site), bird screen ,gravity louvers, fire retardent flexible connection, necessary nut bolts and directly coupled TEFC Sq.cage induction motor (IE3) F Class insulation for pressurization suitable for 415V±10%, 50 Hz. 3 phase electric supply complete with required hardware etc. All offered fans pitch angle shall be AMCA Certified & Listed on AMCA website (Interpolation of pitch angle shall not be acceptable) and Fan Efficiency Grade ( Min FEG 71, lesser is not acceptable).Thickness of the casing shall not be less than: For Dia (300 to 650) mm – 2mm, Dia (700 to 1140) mm – 3 mm, Dia (1200 to 1400) mm – 4mm & Dia 1600 – 5 mm. All fans after assembly shall be dynamically trim-balanced to ISO1940 and AMCA 204/3 - G2.5 quality grade.Fans for emergency application Tube axial are to be used. Sound level for emergency operation it should not exceed 818 Db(A)@ 3 meter (Room condition).Incase of not achieving sound , attenutor has to be added. Outlet velocity of the fans should not exceed 16 m/s for emergency application. (For Exhaust) Make-Krugger/Nikotra/Greenheck/ELTA/Airflow4500 cfm, st pressure 30mm for HALL AREA
398SITC of two-stage Indirect-Direct Evaporative Cooling (IDEC) unit with Air Flow Capacity: 12,700 CMH (7,500 CFM), External Static Pressure (ESP): 300 Pa, Cooling Type: Indirect + Direct Evaporative, Supply Air Fan Motor: 5.5 kW, Working / Secondary Air Fan Motor: 1.1 kW, Water Pump: 0.25 kW x 2 Nos, Power Supply: 415 V / 3 Phase / 50 Hz designed to supply 100% fresh, cooled outdoor air.The fan should have Double skin casing with thermal insulation,Outer skin: PPGI,Inner skin & wet section: SS 304, High efficiency polymer air-to-air heat exchanger, High efficiency antibacterial cellulose cooling pads,Stainless steel water tank with corrosion resistant coatingThe first stage uses an air-to-air indirect evaporative heat exchanger, followed by a second stage of direct evaporative cooling using high-efficiency cellulose pads. Make-DRI/OXYCOM/FLAKTGROUP
399Supply, Manufacturing, fixing,testing and commisioning of Factory Made Flat Oval Spiral Duct with 10 mm open cell antimicrobial 180kg/cum class 'O' ACOUSTIC AND THERMAL insulation .The cost of Insulation shall be included in the ducting Cost with adhasive and all necessary accessores. The Thickness of the Duct shall be of 22 G only shall be as per Ducting SMACNA standards of Flat Ovel Duct . The Cost of Hanging arrangemnet shall be included as per OEM standards and also the GI Hook or GI angle, support clamp shall be used . all nut Bolt shall be of Hot Dipped Galvanized GI nut with washer shall be Used . The Cost of Threaded Rod and Necessary fastner shall be included in the Cost of Ducting Its Self .The Duct Shall be Joint with the POP up rivit or Self Fasting GI screw with Sealent . the Length of Duct Shall be either 4 , 10 or 12 Feet . Branch Peices can be as per the Site Design Requirment . The Duct Collar Can be of Single layer with Insulation to acomodate the Air Distribution Product MakeTATA/SAIL/JINDAL22 GAUGE (0.80 mm thickness)
400Supply, Manufacturing, fixing,testing and commisioning of GI ducting (180 gsm)complete with supports,dampers etc.as per specifications. MakeTATA/SAIL/JINDAL22 GAUGE (0.80 mm thickness)
401Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire
402Supplying, Fixing, testing and commissioning of fire dampers of minimum 90 minutes fire rated in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal and, in confirmation to IS and as per specifications complete etc. as required..Smoke & Fire Dampers. (Make: Air Flow/ Systemair/ Dynacraft)
403Actuators and control panel. (Make:- Belimo/ Siemens/ Danfoss)
404Design, manufacture, supply, installation, testing and commissioning of the following OUTDOOR TYPE cubicle type, wall mounted control panels including anchoring into the wall, wiring and earthing terminating into MPCB in each panel shall be provided by the electrical contractor. All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operation through BAS. All starters shall be provided with potential free Contact for Connections to Building Automation System, single phase preventer (Electronics type) as per the ratings given below. Terminal block for power distribution, Power Contactor.Phase indicating lights and indicating light for ON/OFF/TRIP status phase sequence relay shall also be provided.96 mm x 96 mm digital voltmeter and ammeter with selector switches. Suitable rating starter required as a bypass arrangement in case of VFD failure.Time delay relay for delayed automatic restart of air handling unit motor.(0-180 Sec).Make of switchgear-Legrand/ABB/Siemens/Schneider Make of VFD-HVAC Series of Siemens/Schneider/ABB/DANFOSSWiring for microswitch for starting / stopping the fan when fire damper closes / Power supply for fire damper control panel.For on/off/remote and local operation, 3 pole single throw switch shall be provided in each ventilation fan panel to facilitate override of the automatic operation.All starters shall be provided with suitable potential free contract for connections to the Building Automation System.The number of AHU control panels shall be as follows.63 TPN MPCB with 7.5 HP Three phase Motor with Star Delta Starter. Each of these compartment shall contain indicating lamp with ON/ OFF/ TRIP status of the motors. (Cost of VFD is part of Panel)
405LIGHTENING PROTECTION SYSTEM & SAFETY EQUIPEMENTLightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB
406Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Make-OBO/Dehn/ABB
407Supply of Roof conductor holder for parapet-Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB
408Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB
409Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB
410Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
411Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn/ABB
412Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OOBO/Dehn/ABB
413Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB
414Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB
415Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB
416Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB
417Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
418Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB
419Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB
420Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB
421Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB
422Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB
423Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB
424Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
425Supply installation of high-voltage insulating mat has a thickness of 3.0 mm, rated for maximum use voltage of 33 kV. It withstands an AC proof voltage of 36 kV and an AC dielectric strength of 65 kV, with maximum leakage current limited to 10 mA. Minimum insulation resistance (5000V megger) is 1,00,000 MΩ. Tensile strength is minimum 15 N/mm², with 250% minimum elongation. After 168 hrs aging at 70±1°C, retention is minimum 75% (tensile & elongation); after 48 hrs immersion in acid/alkali/diesel/oil, retention is minimum 80%. The mat offers low-temperature resistance and flame retardance, made of synthetic elastomer, conforming to IS 15652. complete as per direction of Eng-in-charge.(Size-10mx1m) make : mandelia insulation and transmission co./Duratuf/Raychem/Vardhman
426Danger Board.
427Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room.
428Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room..
429SIGNAGES: SITC flexyl of Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages.Make-Prolite/Bajaj
430SITC of 5MP IP Bullet/Dome Camera with inbuilt microphone, equipped with 1/2.7\\" Progressive Scan CMOS image sensor and 3.6/2.8(for dome) mm fixed lens, supporting a resolution of 2592 × 1944 or higher. The camera shall provide IR illumination up to 30 meters and an approximate field of view of 79° (H)/97(for dome), 56°/70(for dome) (V), and 106°/128( for dome) (Diagonal). Minimum illumination shall be 0.003 lux @ F1.6 (AGC ON) with support for WDR (120 dB). The camera shall support video compression formats such as H.265+, H.265, H.264+, H.264 and MJPEG, with multiple streaming capability including main stream up to 5MP @ 30 fps, sub-stream up to 1080p @ 30 fps, and additional third stream. The camera shall support intelligent analytics such as human and vehicle detection, perimeter intrusion detection, line crossing detection, object detection, heat map, crowd density detection, queue length detection, and rare sound detection. The device shall support motion detection with multiple configurable zones and network protocols including TCP/IP, HTTP, DHCP, RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS and SFTP, and shall be ONVIF compliant (Profile S/G/T). The camera shall include micro SD card slot up to 256 GB/512 GB( for dome), privacy masking, ICR auto day/night switching, and support 12V DC or PoE power supply. The housing shall be metal body with IP67 weatherproof protection, suitable for outdoor installation. The product shall comply with NDAA requirements and shall be certified with STQC, BIS, CE, FCC and RoHS. Make-Honeywell Value series/Pelco/Axis/Bosch
431SITC of 5MP IP Varifocal Bullet/Dome Camera with 1/2.7\\" Progressive Scan CMOS image sensor and motorized varifocal lens (2.8–12 mm), supporting a resolution of 2880 × 1620 or higher. The camera shall provide IR illumination up to 50/30( for dome) meters and a variable field of view approximately 107°–34° (H), 55°–19° (V), and 134°–38° (Diagonal). Minimum illumination shall be 0.004 lux with advanced imaging features including Starlight technology and WDR (120 dB) for improved low-light performance. The camera shall support multiple video compression formats such as H.265+, H.265, H.264+, H.264 and MJPEG, with multi-stream capability including main stream up to 5MP @ 30 fps, sub-stream up to 720p @ 30 fps, and an additional third stream. The camera shall support motion detection with configurable zones and event triggers including motion detection, video tampering, scene change, network disconnection, and IP conflict. The device shall support intelligent video analytics such as face recognition, human and vehicle detection, perimeter intrusion detection, line crossing detection, object detection, heat map, crowd density detection, queue length detection, and rare sound detection. It shall support network protocols including TCP/IP, HTTP, DHCP, , RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS and SFTP, and shall be ONVIF compliant (Profile S/G/T). The camera shall include micro SD card slot up to 256 GB/512 gb( for dome), alarm I/O (1/1), audio I/O (1/1), privacy masking, and ICR auto day/night switching. The camera shall support 12V DC or PoE power supply and be housed in a metal weatherproof enclosure with IP67 protection, suitable for outdoor installation. The product shall comply with NDAA requirements and be certified with STQC, BIS, CE, FCC and RoHS or equivalent. Make-Honeywell Value series/Pelco/Axis/Bosch
432SITC of 64CH project series Network Video Recorder, Should support Resolution:- greater than equal to 12 MP IP Camera, Network Bandwidth incoming 640 Mbps and outgoing 640 Mbps for access, support for H.265+/H.265/H.264 encoding format streaming access and decoding output, Recording play back quality: 16 ch play back simultaneously, Recording resolution up to 12MP, Recording mode: support manual, Auto, Motion detection, Alarm, trigger record mode, Operation way: Mouse, local Login: Username and password, Recording storage: Local HDD, network, Video output: HDMI/VGA/TV, Support min. 8 SATA HDDs , Each port supports min. 18TB HDD(Enterprise class),support-RAID0, RAID1, RAID5, RAID6, RAID10,Support dual Gigabit Ethernet ports,Supports 4 HDMI outputs,Alarm Input/out:16 in /4 out ,Audio:1 in / 1 out ,Supports intelligent analytics such as Licence plate detection,Face Recognition,Human&Vehicle Detection,Perimeter Intrusion Detection,Line Crossing Detection, Cross Counting,Stationary Object Detection,Heat Map,Crowd Density Detection,Queue Length Detection, Rare Sound Detection, product must comply with NDAA complaince, Certification: BIS,CE,FCC,ROHS. Make-Honeywell value series /Pelco/Axis/Bosch
433Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba
434SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony
435SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit.
436SITC of Cat6 I/O with Single Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
437SITC of Cat 6, 24-port loaded, 1U Modular patch Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit
438SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length)
439SITC of Cat6 UTP 23 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(2 mtr length)
440SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit
441SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit
442SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit
443SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear
444SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP,Netgear
445SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand
446FIRE FIGHTING ALLSupplying, installation, testing and commissioning of Electric Motor Driven Pressurization Terrace Pump having discharge of 450 LPM at 35 Mtr head complete with Pump Set, Electric Motor suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base Frame.Make-Wilo/KSB/Kirloskar/Grundfoss
447Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of One (1)- 63 Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable for 7.5 HP motor. ON/OFF indication lamps, Auto manual switch and ON/OFF push button.as per direction of engineer in charge Control panel for fire pumps for auto action.make-Legrand/schneider/Siemens/ABB
448Supply & Laying ofAl armoured XLPE power cable of 1.1 KV grade of following size on Cable3C X 16 sqmm xlpe Armoued cable
449End Termination 3C X 16 sqmm
450Supplying, installation testing and commissioning of the following-: ‘C’ class MS Pipe as per IS1239 for underground/over ground pipes with welded / flanged connection with saddles, supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches. The work includes excavation in all types of soils and back filling, dewatering, etc., making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the client and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overheads pipes and providing and fixing pyp kote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping for underground piping (wrapping should have overlap of 15 to 20 mm) etc.Complete as per ASTM standards/IS: 10221 for corrosion protection of pipes for the underground installation.Note: The piping installation has to be put to hydraulic test to1.5 times the working pressure & as per latest applicable codes & standard before applying paint or pipe coating or wrapping etc. complete. Make-TATA/JINDAL/SAIL100mm NB
45180mm NB
45225mm NB
453Providing, fixing, testing and commissioning of following size manually operated hand lever type cast iron double flanged slim seal wafer type Butterfly valves with EPDM iron disc as per IS-13095 having pressure ratting PN -1.60 including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of E.I.C.Make-Zoloto/AUDCO/Leader100mm NB
454Providing, fitting & fixing of following size cast iron double flanged type dual plate Non return Valve as per IS- 5312 (Part 1): 2004 with ISI mark of pressure ratting PN-1.60 including fixing the same with supply of required jointing materials like flanges, rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of Engineer-in-charge. Make-Zoloto/AUDCO/Leader100mm NB
455Supply,Installation,Testing & Commissioning of orifice plate made of 6mm thick stainless steel with orifice of required size in between flane and landing valve of external and internal hydrant to reduce pressure to working pressure of 3.5 Kg/ sq cm complete as required.
456Supply,Installation,Testing & Commissioning of Pressure gauge of 0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable size with all accessories as per direction of Engineer-in-charge.MAKE: H.GURU/G.GURU
457Supply,Installation,Testing & Commissioning of Pressure Switch with cut-off bronze ball valves with integral strainer & flare nut (mixed ends) of suitable size with all accessories as per direction of Engineer-in-charge.MAKE: DANFOSS/INDFOSS make
458Supply,Installation,Testing & Commissioning of 100 MM stainless steel strainer fabricated out of 1.6 mm thick stainless steel sheet Y Stainer with 3 mm dia hloes with stainless steel flange as required. Make-Zoloto/AUDCO/Leader
459Supply,Installation,Testing & Commissioning of Air vessel made of 250mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint as required.
460Supply,Installation,Testing & Commissioning of Stainless steel Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique type, as per IS :5290/93 and as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex
461Supply,Installation,Testing & Commissioning of SS short branch pipe with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 and as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex
462Supply,Installation,Testing & Commissioning of 63 mm NB and 15meter long RRL Fire Hose fitted with 63mm intstantaneous stainless steel male & female SS coupling, complete by GI wire binding for Internal Hydrant as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex
463Providing supply & fixing of MS Hose Box for of suitable size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30 mtr long fire hose and a branch pipe, wall mounted type as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex
464Supply,Installation,Testing & Commissioning of Swinging pattern wall fixing first aid hose reel made from MS sheet and waterways and moving parts with rubber hose of 20 mm dia. and 30 mtrs. long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585 Type-I., complete with all accessories as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex
465Providing, fitting and fixing of C.I. 25 MM single air relief valve with stop cock confirming to IS:14845/2000 with ISI mark for water works purpose including fixing the same with hydrant riser including testing & commissioning the system etc. all complete as per approved specification & direction of Engineer-in-charge.
466Providing, fitting & fixing of 2-Way GM fire brigade connection consisting of 63 mm dia instantaneous type male couplings with built-in check valves, 100mm dia flanged outlet complete with bolts, nuts and rubber insertions confirming to IS:904 with ISI mark including testing & commissioning the system etc. all complete as per apporoved specification & direction of EIC. Make-Minimax/Newage/Fireshield/Safex
467Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire/Flameklog/Kalpex .4.5 kg capacity
468Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire/Flameklog/Kalpex.6 kg capacity
469Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized stseel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter \\"FIRE\\" in black and gold. Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets.
470Supplying, installing, testing and commissioning of photo electric adressable multi sense smoke detector with inbuilt isolator module/isolator base ,base, junction box and other accessories.Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider
471SITC of Response Indicator..Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider
472Supplying, installation, testing and commissioning of Intelligent Reflective Beam Detector with 4 pieces Reflectors, Capable used as Conventional detector, Fire and Fault signal relays available, 24VDC required, Detection Range 8-100 Meters (Certified by LPCB): GREEN / AMBER / RED Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider
473Supply, installing, testing and commissioning of of 2 Loop Network Panel Micro processor based 2 wire fault tolerant loop,with inbuilt network port (each loop accessing 99 or more detectors and 99 or more modules ) fire alarm/detection control panel. The Panel shall have 10000 or more event log history . Panel shall be capable of having 1600 or more configurable zones .The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFFrespective control module when ever any alarm is triggered. The panel shall have 7 Inch Touch Screen unit to indicate Fire/Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects.The Panel Shallbe Sheet Steel Painted, selaed to IP30. The Panel Shall have provision for 40 or more Zones with Individual LED Indicators expdable upto 200 Zones or higher. The panel shall have a built in power supply and battery charger along with maintenance free 7 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 48 hours with battery charger complete as required.and as per specifications. conforming to BS5839 Standards and Duly Approved by EN54 The panel shall support detection logics like coincidence & verification detections for the false alarm management. The Panel shall adjust the sensitivity between day and night to maintain the better detection/reponse time. The Panel shall be capabale of programming through PC ; Touch Screen of USB .This panel having facility of MODBUS protocol over TCP/IP for BMS integration.The panel should have provision for inbuilt RJ45 connection terminal for connecting to the LAN with inbuilt BACNET Protocol. Make- Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider
474Supplying, installation, testing & commissioning of Addressable Single Output Module,Single Output Module, provides dry contact (Loop powered) or active output (24VDC required, cable monitored) (Certified by LPCB)) indicates system status: GREEN / AMBER / RED.Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider
475Supplying, installing, testing and commissioning of Addressable Manual Call Point with back box.Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider
476Supplying, installing, testing and commissioning of Analogue Addressable Loop powered Sounder with strobe light.MakeHoneywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider Please Enable Macros to View BoQ information
477Supplying, installing, testing and commissioning of Analogue Addressable Loop powered Sounder with strobe light.MakeHoneywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58283146
AUTHORITY Government Departments
TENDER VALUE 11.60 Crore
LAST DATE 16-11-2026
Authority
Authority Name Civil Division
Work Description Tender for Construction Of Block Level Stadium In Deogaon Block (With Indoor Hall) In Balangir District.
Basic Detail
Tender No CE-Bldg-II-40/2026-27
Bidding Type Tender
Location
City Balangir
State Odisha
Key Dates
Publish Date 30 Oct 2026
Submission Date 16 Nov 2026
Open Date 17 Nov 2026
Finance
Tender Value 11.60 Crore
Tender Fee 10000
EMD 11.61 Lakhs
Exemption Available
Document List
BOQ_616573.xls
f14d2afd-54c3-4dfe-828c-a3aec42d6fde.html
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Nov 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_616573.xls

html

f14d2afd-54c3-4dfe-828c-a3aec42d6fde.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender