Tender For Repairing Work Of Annexe Building Roof(West Side Part) And False Ceiling Repairing Work At Assessment Dept Under Howrah Municipal Corporation
Tender Value
8.59 Lakhs
Estimated cost
Bid Submission
10 Nov 2026
10 days left
EMD
17186
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Howrah → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairing Work Of Annexe Building Roof(West Side Part) And False Ceiling Repairing Work At Assessment Dept Under Howrah Municipal Corporation
BOQ
| Sl. No. | Item Description |
| 1 | Stripping off worn out plaster and raking outjoints of walls, celings etc. upto any height and inany floor including removing rubbish within alead of 75m as directed.P-11 Item10 |
| 2 | Taking out carefully Ranigunge pattern tiles fromroof stacking seviceable tiles at site and removingrubbish as directed within a lead of 75m.P-11 Item-7 |
| 3 | Cutting chase upto 125 x 150 mm. and subsequentmending of damages(a) in brick wall [Cement-3.6 Kg/Mtr]P-12 Item11(a) |
| 4 | Repairs to roof cracks with cement and sand mortar (1:4) including cutting grooves and cleaning cracks and grouting the cracks with neat cement before repairs. (Cement 0.63 Kg/Mtr. )P-94 Item-3 |
| 5 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortar(b) 15 mm thick plasterP-189 Item-1(II)(B) 3rd corrd |
| 6 | a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with waterin proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]P-45 Item-8/a |
| 7 | Chipping of concrete surface P-45 Item-8/a |
| 8 | Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge.P-45 Item-5 |
| 9 | Removal of rubbish,earth etc. from the workingsite and disposal of the same beyond thecompound, in conformity with the Municipal /Corporation Rules for such disposal, loading intotruck and cleaning the site in all respect as perdirection of Engineer in chargeP-12 Item-13 |
| 10 | Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as permanufacturers specification. (0.4 Kg / m² of concrete surface).P-45 Item-7 |
| 11 | Square or hexagonal mesh netting made with 18 B.W.G. galvanised wire, fitted and fixed complete as per design (excluding the supporting framework butincluding local sal wood battens of size 37.5mmx25mm). In ground floorP-138 Item-10/a |
| 12 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.Pakur varietyP-41 Item-33+3rd corrd |
| 13 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.P-192 no-15 |
| 14 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterioremulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.(b) Two CoatsP-196 no-8(b) |
| 15 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction ofEngineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidentalcharges but excluding the cost of primer.a) Normal Acrylic EmulsionP-197 no-17(a) |
| 16 | Daily Labour needs for removing and lifting the rubbish from 6th floor to ground floorP-303 no-3 |
| 17 | Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades.P-45 no-9 |
| 18 | M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I. intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mmx0.55 mm thick fixed to the ceilingwith G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50 mmx26mm fixed to the intermediate channels with the help of connecting clip and in the direction of perpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section asabove by machine screws. The boards are to be joined and finished with jointingcompound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes,cost of accessories, fittings and fixtures, scaffolding and labour charges etc.complete)In ground floorP-165 no-17 |
| 19 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)P-198 no-5 |
| 20 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparingthe surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)(b) Two CoatsP-195 no-4/II |
| 21 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty(to be done under specific instruction of Superintending Engineer) :(Two coats)ii) Luxury QualityP-201 no-4/II |
| 22 | G.S.T. @18% |
| 23 | l.W.cess @1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer