Tender For Supply, Installation, Testing & Commissioning Of Auxiliary Warning System (Aws) In Connection With 5Th & 6Th Line Works Between Borivali-Virar Section, Mumbai Division
Tender Value
9.11 Crore
Estimated cost
Bid Submission
30 Nov 2026
12 days left
EMD
18.22 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Installation, Testing & Commissioning Of Auxiliary Warning System (Aws) In Connection With 5Th & 6Th Line Works Between Borivali-Virar Section, Mumbai Division
BOQ
| Sl. No. | Item Description |
| 1 | Supply of AWS Track Magnets 'A1'/'A2'/'B1' type Siemens make. Qty. of each type of Track Magnet to be advised by Engineer-in-charge before making supply. Cat No. S25432-M1-A1-10 |
| 2 | Supply of Opto coupler box & safety cover of FRP for fixing Siemens type opto coupler cards inside box for installation of AWS with mounting clamps as per W. Rly. Drg. & practice. |
| 3 | Supply of Siemens make C. Railway type Hu/Husp/Hsp type Opto Coupler Cards Siemens MAKE. Qty. of each type of card to be advised by Engineer-in-charge before making supply.DrG No RSg/AWS/006H1C,RSG/AWS/006H3C.RSG/AWS/004BIC,RSG/AWS/004B3C. |
| 4 | Supply of PVC flexible wire of size 48/ 0.2 mm annealed copper conductors as per specification IS 694 : 1990 of Finolex make or similar for connecting opto coupler box to signal transformer fixed inside signal unit/ location boxes as per standard practice. ( 30% green, 20% yellow, 20% red, 10% white, 10% blue & 10% black colour wires are to be supplied.) |
| 5 | Supply of GI Reducer of size 40 mm/ 20 mm as per specification IS 1239 (Part 2 ) : 1992 \\" Medium\\" class for installation of AWS. |
| 6 | Supply of Stainless Steel clamps of SS-304 type and size 'B' for fixing Neoprene rubber tube on reducer & six pin coupler of track magnet and PVC Conduit pipe with glands fixed on signal post & opto coupler box. |
| 7 | Supply of copper lugs of various sizes of Dowells make or simlar for terminating cable conductors inside opto coupler boxes, junction boxes and on signal transformers etc. for installation of AWS . |
| 8 | Supply of brass glands having nipple on both side, threaded inside & plain outside for installation of AWS. |
| 9 | Supply of Neoprene Rubber Pipe of suitable size for taking 7 core cable from reducer to six pin coupler of track magnet for installation of AWS. |
| 10 | Supply of PVC flexible Pipe of internal dia of 25 mm for taking cable conductors from signal post to opto coupler box for installation of AWS. The sample shall got be approved before supply. |
| 11 | Supply of screened 7 core PVC insulated copper cable having each core made up of 30 x 0.25 mm tinned stranded copper conductors for AWS generally confirming to IRS :S76/89 - Siemens Spec. RSG/AWS/0035. |
| 12 | Supply of Track magnet Clamps with 6 pin plug for fixing with rail suitable for both 52 Kg & 60 Kg rail for 'A1'/A2/B2 type Track Magnets . 6 Pin Plug Cat No C25334-Z4-C155. |
| 13 | Supply of GI pipes of nominal bore 40 mm with sockets as per specification IS 1239 (Part 1 ) : 1990 \\"Medium\\" class in length of approximately 6 meters. Manufacturer's test certificate is to be submitted by the contractor. |
| 14 | Supply of AWS Tools kit as per ANNEXURE |
| 15 | Fixing of track magnet as per C. Rly.Drg.no. RST-11472/4 with anti-theft clamp. ( Note : Track magnets are to be covered with metal sheet temperoarily till final testing & commissioning. These sheets are to be removed just before commissioning.) |
| 16 | Fixing of opto coupler junction box on signal post and providing cable gland (25mm dia.) on signal post after drilling holes and tapping threads on signal posts. |
| 17 | Laying and fixing of GI pipes of 40mm dia in trenches & along signal post from A1/A2/B2 type track magnet to opto coupler box and connecting it to opto coupler box on the signal post with proper clamps, elbow, bend etc. Clamps for fixing GI pipe on signal post, other fixng materials including GI nut-bolts of suitable sizes are to be supplied by contractor.). This item includes cutting of GI pipe of suitable length and threading of pipe for their proper coupling arrangement before laying. |
| 18 | Laying of 7 core PVC insulated cable through GI pipe and Neoprene rubber pipe between opto coupler box and six pin coupler of A1/A2/B2 type track magnets. Termination of cable conductors on opto coupler card with help of crimpped lugs with proper dressing. PVC numbering sleeve is to be provided on cable conductor on opto coupler box side. 7 core PVC cable on 6 pin coupler is to be soldered & PVC sleeve is to be provided as per standard practices followed by Raliways. After soldering six pin coupler is to be properly sealed by silicon sealant compound. Insulation tape, lugs, GI nuts- bolts etc. will be supplied by the contractor. |
| 19 | Laying flexible wire between Main/Route/Auxillary signal units and opto coupler box through signal post and reinforced PVC flexible conduit pipe and termination at both ends with appropriate size copper lugs. Wires are to laid only after proper lacing and dressing with lacing thread. PVC flexible pipe is to be properly fixed with glands on signal post & opto coupler cards with help of SS clamp as shown in drawing. |
| 20 | Testing of track magnets by test jig and commissioning of complete AWS equipments as per standard practices on Central Railway and instruction of site incharge after installation at site. (Testing report is to be submitted before commissioning). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.