Tender For Comprehensive Maintenance Of 10 Mw Capacity Captive Power Plant (Cpp) At Naval Base Karwar
Tender Value
84.78 Lakhs
Estimated cost
Bid Submission
26 Nov 2026
4 days left
EMD
1.52 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Uttara Kannada → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Comprehensive Maintenance Of 10 Mw Capacity Captive Power Plant (Cpp) At Naval Base Karwar
BOQ
| Sl. No. | Item Description |
| 1 | M& L for servicing of Turbocharger comprising of following works & Dynamic balancing of the Rotor Shaft to be carried out by qualified team of engineers from Manufacturers Authorised Repair Workshop:- i) Dismantling the turbocharger from the installed position & removing , loading, transporting the turbocharger cartridge to OEM authorised & approved workshop for dynamic balancing.ii) Mechanical cleaning , assesmment & working condition evaluation of the turbochargeriii) Complete overhaul & servicing of the turbocharger iv) Dismantling of the Cartridge , Mechanical cleaning of the rotor and Assessment of the rotor shaft & condition evaluation |
| 2 | v) Replacement of Standard Overhaul Spare parts as required at site and directed by GE.vi) Dynamic balancing of the rotor shaft & balancing of the rotor completevii) Re Assembling the complete cartridge & transporting back to the siteviii) Re Assembling the complete turbocharger with the cartridge, re- installing & commisioning of turbocharger assembly with the DG sets complete as per OEM Standards ix) Documentation & submission of the service & test reports as per prescribed format. |
| 3 | M & L for Maint/ Servicing of diesel engine of air compressor type DA 16, BHP 16.2 cylinder , removing tappet cover after removing inlet / outlet pipe removing engine head replacing unserviceable valve seat & valve guide inlet & outlet as required replacing engine main gasket sheet cleaning the oil sump, cleaning/ replacement of fuel oil filter complete all as specified and as directed.Note :- Rate quoted includes cost of new items for replacementThe engine oil for filling/topup will be meausued and paid seperately. |
| 4 | M & L for Servicing of Lube Oil Coolers by dismantling, condition evaluation, transporting to workshop, thorough mechanical /ultrasonic mechanical cleaning the copper tube by steel brush, replacement of worn out parts like Synthetic rubber rings, Gaskets, O rings , nuts and bolts etc., assessment of leakages through pressure testing, reinstalling in original position & tetsing as per OEM standards complete all as specified and as directed.Note :- Rate quoted includes cost of new items for replacement. |
| 5 | M & L for Servicing of Starting Air Compressor 12.5 HP by disconnecting electric motor & outlet piping, transporting the air compressor to work shop, dismantling air compressor, replacing worn our parts such as piston Ring, Oil Ring, Gas Ket Set, Bearings, Greasing Oiling & Reinstalling air compressor in original position including replacement of unserviceable soloniod coil, pressure switch etc , testing & comissioning all as specified and directed. Make ELGI, Model HP 12300 max working pressure 30 Bar, RPM 1100 of Air compressor. Note :- Rate quoted includes cost of new items for replacement |
| 6 | M&L for servicing of the safety valve of air receiver capacity 0.50m3 , working pressure 30 kg/cm2, Design pressure 33 kg/cm2 & test pressure 50 kg/cm2 complete all as specifed and as directed. |
| 7 | S & F in replacement of air drain valve max. Working pressure 35 kg/cm2, end can size 0.5 BSP, Max. Working temp. 75degee C. for air receiver complete all as specifed & directed. |
| 8 | M/L for servicing of DG control panel installed in CPP control room involving Calibration of the DE/NDE Sensors (01 set ie 02 nos, Ground protection Relay (01 no). ABB REM 543. 110v AC.Aux,V:24vdc. 7CT,2PT Input (01 no.), Gen. ROTOR Earth fault relay ( 01 nos.), Gen. STATOR Earth fault relay (1 nos.), Triping Relay & Dead Bus Relay (2 nos) complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 9 | M/L for servicing of DG control panel installed in CPP control room involving Calibration of the DE/NDE Sensors (01 set ie 02 nos, Ground protection Relay (01 no). ABB REM 543. 110v AC.Aux,V:24vdc. 7CT,2PT Input (01 no.), Gen. ROTOR Earth fault relay ( 01 nos.), Gen. STATOR Earth fault relay (1 nos.), Triping Relay & Dead Bus Relay (2 nos) complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysNov 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender