Tender For Certain B/R Repair Works In Otms Airmen/Dsc Accn, Airmen Mess, Fire Section, Mes Office Bldg (Zone-Ii) And E&M Installation In Domestic Area Under Age B/R-1 At Bhisiana Under Ge (Af) Bhisiana
Tender Value
40 Lakhs
Estimated cost
Bid Submission
10 Nov 2026
10 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bathinda → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Certain B/R Repair Works In Otms Airmen/Dsc Accn, Airmen Mess, Fire Section, Mes Office Bldg (Zone-Ii) And E&M Installation In Domestic Area Under Age B/R-1 At Bhisiana Under Ge (Af) Bhisiana
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles in any description and removing/disposal off from the site to outside MOD land complete all as specified and as directed. |
| 2 | Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge. |
| 3 | Material and labour for brick work in half brick thick wall straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge. |
| 4 | Taking down cement plaster/rough cast plaster from brick walls/soffits of roof projections & chajjas /ceilings etc. including racking out joints, hacking for key & scrubbing down with water etc including disposal of rubbish material to any distance out side MOD land complete all as specified and as directed. |
| 5 | Material and labour for 15mm thick cement plastering/ rendering in cement mortar (1:4) on any face of Brick walls or concrete surfaces, finished even and fair complete all as specified and as directed. |
| 6 | Material and labour for rendering/plastering 15 mm thick in CM (1:6) on any face of Brick walls or concrete surfaces, finished even and fair complete all as specified and as directed. |
| 7 | Material and labour for rendering/plastering 5 mm thick in CM (1:3) on concrete surfaces of ceiling, finished fair and even complete all as specified and as directed. |
| 8 | Material and labour for rough cast plaster on exterior walls in two layers, under layer not less than 10mm cement plaster (1:3) (1 cement: 3 coarse sand ) furrowing the under layer with scratching tool, and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (which is generally of size between 6 to 12 mm depending on the texture required) mixed with coarse sand and cement in the ratio of (1: 1: 1) shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger aggregates are thoroughly covered, complete in all respects and as specified and directed by the Engineer-in-Charge. |
| 9 | Material and labour for preparation of old treated surfaces (plastered / unplastered) of ceiling by remove / scraping down all loose treatment etc with using broom, wire brush or by any other mean and after preparing the surfaces applying one coat of white wash by using paint brush complete all as specified and as directed. |
| 10 | Material and labour for preparation of old treated surfaces (plastered / unplastered) of walls/pillars /cornices by remove / scraping down all loose treatment etc with using broom, wire brush or by any other mean and after preparing the surfaces applying one coat of white wash by using paint brush complete all as specified and as directed. |
| 11 | Material and labour for preparation of new plastered surfaces of ceiling by brooming down or by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash by using paint brush complete all as specified and as directed. |
| 12 | Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down or by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash by using paint brush complete all as specified and as directed. |
| 13 | Material and labour for preparation of existing treated surface of walls/pillars /cornices etc. by removing/scraping all loose paint, treatment, dust, dirt and other foreign matter using broom, paint brush, sand paper, wall sander or any other suitable means as required. The item includes filling of nail holes, pin holes and hairline cracks with approved putty wherever required and prepared to obtain a smooth and even finish. Thereafter, applying one coat of Oil Bound Distemper (OBD) of approved make and shade as per surface condition matching the existing, applying by using paint brush or roller brush complete all as specified and as directed. |
| 14 | Material and labour for preparing the surface and applying two coats of Oil Bound Distemper (OBD) of approved make and shade to walls/pillars /cornices surfaces (over any type of surface new or old prepared after complete removal etc.) over one coat of cement primer suitable for OBD, paint and primer applying by using paint brush or roller brush complete all as specified and as directed. |
| 15 | Material and labour for preparation of plastered surfaces of walls/pillars /cornices (on new surface or old prepared surface after complete removal) by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint as per approved tint/colour with using paint brush complete all as specified and as directed. |
| 16 | Material and labour for preparation of existing treated surface of walls/pillars /cornices etc. by removing/scraping all loose paint, treatment, dust, dirt and other foreign matter using broom, paint brush, sand paper, wall sander or any other suitable means as required, washing down with water and applying one coats of cement base paint as per existing tint/colour with using paint brush complete all as specified and as directed. |
| 17 | Material and labour for complete removal of existing treatment of any type/description (any layer) from external/internal wall/ceiling surfaces, soffits/chajja/roof projection surfaces etc., by scraping steel patti and Mechanical sander/grinder machine having suction vaccum Bag (Smart periodical methodology), complete all as specified and as directed. |
| 18 | Material and labour for providing and applying approved texture mortar finish to walls, 5 mm thick in two layers, in cement mortar 1:2 comprising one part white cement and two parts Dholpur clear quartz powder of 1 to 2 mm grading, finished to a plain stone-masonry pattern as required to achieve the approved texture and finish, including surface preparation, application of two coats of approved exterior grade elastomeric paint over one coat of approved exterior grade wall primer, complete all as specified and as directed by the Engineer-in-Charge. |
| 19 | Material and labour for preparation of interior surfaces of walls/ceiling/soffits etc (over any type of surface new or old prepared after complete removal etc), applying acrylic putty is a water-based, Smooth, creamy paste (ready-to-use), white or off-white color (thickness from 1.0 to 1.5 mm as required for desired smoothness and levelling of surfaces in two layers), including sanding with wall sander after filling the putty in first coat/second coat to make surface smooth and ready for receiving further painting work complete all as specified and as directed.Notes : (i) The prepared surface after putty, the contractor will inform to the Engineer-in-Charge/GE for site inspection before applying further finishes. Further finishes work will start only after approval of the prepared surface from the Engineer-in-Charge through site order. |
| 20 | Material and labour for preparing the surface and applying 02 coats of exterior acrylic emulsion paint of approved tint/shade (Company Depot Tinted) to external surface of walls /pillar, Soffits of Chajjas / Roof Projections / Cantilevers / Balcony etc. (over any type of surface new or old prepared after complete removal etc) over and including a coat of exterior alkali resistant water-based primer (primer shall be same make as acrylic emulsion paint), paint and primer applying by using paint roller/brush or airless spray gun complete all as specified and as directed.Brand and Make of exterior acrylic emulsion paint: - Apex Ultima of Asian / Weather Coat antidust of Berger / Weather shield Protect of Dulux / Excel Mica Marble of NerolacBrand and Make of primer for external : - Seal O Primer of Berger / Smart Care Primero of Asian / Excel Alkali Prime of Nerolac / Weather Shield Alkali Bloc of Dulux |
| 21 | Material and labour for Writing letters or figures with synthetic enamel paint (Block. Roman, Italic or Indian) not exceeding 30 cm high etc complete all as specified and as directed. |
| 22 | Material and labour for preparation of new steel and iron surfaces of any description, not otherwise described, exceeding 10 cm in width or girth, including cleaning the surface free from dust, dirt, grease, oil and other foreign matter and surface imperfections by rubbing down with emery paper/sand paper or by other approved means to obtain a clean, smooth and even surface and further applying one coat of red oxide zinc chromate primer and two coats of first-quality synthetic enamel paint of approved brand, shade and tint, each coat applied by brush only after proper preparation and complete drying of the preceding coat, to produce a smooth, uniform, durable and aesthetically acceptable finish, complete in all respects as specified and directed by the Engineer-in-Charge. |
| 23 | Material and labour for preparation of new wooden or wood-based surfaces of any description, not otherwise described, exceeding 10 cm in width or girth, including cleaning the surface free from dust, dirt and other foreign matter, rubbing down with sand paper to obtain a smooth and even surface, filling nail holes, minor cracks, joints and hairline defects with approved wood filler or a mixture of synthetic adhesive (Fevicol or equivalent) and commercial wood powder, and rubbing down the filled surfaces smooth after drying, and further applying one coat of pink wood primer and two coats of synthetic enamel paint of approved brand and shade, each coat applied by brush only after proper preparation and complete drying of the preceding coat, to produce a smooth, uniform, durable and aesthetically acceptable finish, complete in all respects as specified and directed by the Engineer-in-Charge. |
| 24 | Material and labour for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour as per existing with using paint brush complete all as specified and as directed. |
| 25 | Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using sanded paper, clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish with using paint brush complete all as specified and as directed. |
| 26 | Material and labour for carrying out post-construction anti-termite treatment of voids in masonry by drilling holes at an angle of approximately 45 degrees at intervals of 300 mm centre-to-centre and injecting approved chemical emulsion at the rate of 1.00 litre per hole, including subsequently plugging and sealing the holes with cement mortar (1:2) (1 part cement : 2 parts coarse sand) to match the existing floor finish/surface, complete all as specified and as directed by the Engineer-in-Charge. |
| 27 | Material and labour for mild steel TMT bars, grade Fe 500D/550D, 6 to 8 mm dia cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.(NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.) |
| 28 | Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position and including disposal of rubbish material to any distance out side MOD land complete all as specified and as directed. |
| 29 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided including removing debries/rubbish material from site to outside MOD land complete all as specified and as directed. |
| 30 | Dismantling of interlocking tile/paver block/brick/chequered tile etc including kerb stone (laid flat or on edge etc) laid dry or pointed complete all as specified and as directed. |
| 31 | Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement complete all as specified and as directed |
| 32 | Material and labour for PCC (1:2:4), type B-0 using 12.5 mm graded stone aggregate as in coping at roof, roof kerb (golla) or mud stops along parapet wall, side of roof sheet along parapet wall, adjoining to roof in concave shape & similar work etc at any height, rounded or chamfered on edges including necessary form work etc complete all as specified and directed by Engineer-in-Charge. |
| 33 | Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in surface channels, benching/coping of manholes/drains, coping, mud stops, packing sides/around of interlocking tiles, kerbs, bed block, cills, thrust block, for embedded posts & similar work etc at ground and normal height including weatherings, slightly rounded or chamfered angles and including necessary form work as required etc. complete all as specified and as directed. |
| 34 | Material and labour for 100mm thick cement concrete (1:2:4), Type-B-1 , using 20 mm graded stone aggregates as in floors, pavement, hardstanding and finishing the surface of concrete topping even and smooth (without using extra cement) complete all as specified and as directed. |
| 35 | Material and labour for 75mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed. |
| 36 | Material and labour for 15 mm thick bedding layer in cement mortar (1:6) in grey cement, and finish the surface even and fair/rough to receive the tile complete all as specified and as directed. |
| 37 | Material and labour for providing and laying coloured chequered cement concrete tiles of size exceeding 0.04 sqm but not exceeding 0.11 sqm, 25mm thick, manufactured by the table vibratory method using PU/rubber moulds, made from cement, graded aggregates, pre-polished white cement and pigments, having approved pattern and texture, laid as in floors, footpaths, walkways and similar locations. The tiles shall be laid true to line, level and required slope, set and jointed in neat grey cement slurry at the rate of 3.00 kg per square metre, over the prepared bed/sub base (sub base bed measured and paid separately), filling joints with white cement mixed with matching pigment, complete in all respects, as specified and directed by the Engineer-in-Charge. |
| 38 | Supply and laying/fixing 60mm thick factory-made chamfered edge cement concrete paver block/ interlocking tile of M-35 grade, conforming to IS 15658:2021, grey cement with pigment, with approved design/size/ shape made by table vibratory method using PU mould, laid as in footpath, parks, lawns, drive ways or light traffic parking etc., over and including 30mm thick compacted bed of fine sand and filling the joints with sand, compacting through vibratory compaction by using plate vibrator, finishing and sweeping extra sand complete all as specified and as directed. |
| 39 | Material and labour for Dismantling/taking out old paver block/ interlocking tile of any description and in any position, making surface leveled as per site requirement and refixing/laying the same over and including 30mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand, finishing and sweeping extra sand complete all as specified and as directed. |
| 40 | Dismantling of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from building and thrown in low lying empty area at any distance as direccted from the site complete all as specified and as directed |
| 41 | M&L for providing Non-skid tiles (approved shade), area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm (square/rectangular), as per IS 15622: 2017 and IS 13712: 2019, group B1b, having thickness not less than 7mm, premium quality having water absorption should be between 3% to 6%, straight edge/rectified, stain free, laid as in Flooring, set and jointed in Neat grey Cement Slurry and pointed in White/Coloured Cement, laid over and including 15mm thick Screed Bed in Cement Mortar (1:4), complete all as specified and as directed. |
| 42 | M&L for providing Non-skid tiles (approved shade), area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm (square/rectangular), as per IS 15622: 2017 and IS 13712: 2019, group B1b, having thickness not less than 7mm, premium quality having water absorption should be between 3% to 6%, straight edge/rectified, stain free, laid as in Flooring and connected skirting where required, set and jointed in Neat grey Cement Slurry and pointed in White/Coloured Cement, laid over and including Screed Bed 15mm thick for floor and 10mm for skirting in Cement Mortar (1:4), complete all as specified and as directed. |
| 43 | M&L for providing Non-skid tiles (approved shade), area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm (square/rectangular), as per IS 15622: 2017 and IS 13712: 2019, group B1b, having thickness not less than 7mm, premium quality having water absorption should be between 3% to 6%, straight edge/rectified, stain free, laid as in Flooring and connected skirting where required, set and jointed in Neat grey Cement Slurry and pointed in White/Coloured Cement, laid over and including Screed Bed 15mm thick for floor and 10mm for skirting in Cement Mortar (1:4), complete all as specified and as directed. |
| 44 | M&L for providing glazed ceramic coloured tiles (any shade in any pattern of light & dark, with or without highlighters etc as approved), as per IS 15622: 2017 and IS 13712: 2019, group B IIa, having thickness not less than 7mm, Premium quality having water absorption should be between 3% to 6%, straight edge/rectified, stain free, size of tile 350x250mm/ 450x300mm or any size between area of each tile exceeding 0.06 Sqm and not exceeding 0.18Sqm thick as direcetd as in Vertical Surface/Dado etc., set and jointed in Neat grey Cement Slurry and pointed in White or Colour Cement to match the Tiles, laid over and including 10mm thick Screed Bed in Cement Mortar (1:4), complete all as specified and as directed. |
| 45 | Dismantling of stone slab/tiling including cement mortar bedding ( but not backing) and including removing rubbish material from building and thrown in low lying empty area at any distance as direccted from the site complete all as specified and as directed by Engineer-in-Charge. |
| 46 | Material and labour 16-18mm thick Granite stone slab (thappi) in approved shade (like dark black, mahroom etc), machine cut, duly factory grinding and polishing (table rubbed and polished), as in table tops, steps, treads, risers, jambs, pillars, window cills, cooking platforms, for counter sunk wash basin, Reception Counter and like or similar locations where directed, set & jointed in and including neat cement slurry, laid over and including 15mm thick cement mortar (1:4) screed bed, and pointing in white cement mixing with pigment to match with shade of slab, including cutting, dressing, edge finishing, rounding of exposed edges where required, including cleaning and extra polishing if required complete all as specified and as directed.Note : (i) Single piece should be used in steps/jambs/shelves, equal to width of slab (ii) The rate shall be deemed to include for accommodating holes/openings for gas pipes in kitchen cooking platforms and cutting for countertop/table top/under-counter wash basins, wherever required to suit the dimensions of the item being fixed. No extra payment shall be admissible on this account. |
| 47 | Material and labour for providing and fixing machine-cut, selected quality marble stone, of approved shade and pattern (Makrana White, Doongri, Udaipur Green or approved equivalent), 12–14 mm thick, as in table tops, steps, treads, risers, jambs, pillars, window cills, cooking platforms, for counter sunk wash basin and like and connected skirting, or similar locations where directed, set & jointed in and including neat cement slurry, laid over and including 15mm thick cement mortar (1:4) screed bed for horizonal and 10mm for skirting in Cement Mortar (1:4), including cutting, dressing, edge finishing, rounding of exposed edges where required, and pointing joints with white cement mortar (1:2) mixed with marble dust and matching pigment to suit the colour and shade of the marble, including rubbing /grinding and polishing by machine/hand machine, complete in all respects as specified and directed by the Engineer-in-Charge.Note : (i) Single piece should be used in steps/jambs/shelves, equal to width of slab (ii) The rate shall be deemed to include for accommodating holes/openings for gas pipes in kitchen cooking platforms and cutting for countertop/table top opening for under-counter wash basins, wherever required to suit the dimensions of the item being fixed. No extra payment shall be admissible on this account. |
| 48 | Material and labour for providing and fixing machine-cut Kota stone slabs, 16–18mm thick (minimum), of approved quality, colour and shade, Kota stone size of slab not less than 550x500mm, as in flooring, cut to the required size and shape, dressed true, set and jointed in position over and including a 15mm thick cement mortar (1:4) screed bed, laid to the required line, level and slope, with neat cement slurry. The work shall include cutting, dressing, trimming, machine finishing, forming mitred joints where required, pointing joints with white cement mixed with suitable matching pigment to match the colour and shade of the stone, rubbing, grinding and final polishing by machine/hand-held polishing machine to produce a smooth, even and lustrous finish, complete in all respects, as specified and directed by the Engineer-in-Charge. |
| 49 | Material and labour for providing and fixing machine-cut Kota stone slabs, 16–18mm thick (minimum), of approved quality, colour and shade, in stair treads, risers, landings, skirting, dado, pillar cladding and other similar locations, cut to the required size and shape, dressed true, set and jointed in position over and including a 10mm thick cement mortar (1:3) screed bed, laid to the required line, level and slope, with neat cement slurry. The work shall include cutting, dressing, trimming, machine finishing, forming mitred joints where required, rounding or chamfering exposed edges, pointing joints with white cement mixed with suitable matching pigment to match the colour and shade of the stone, rubbing, grinding and final polishing by machine/hand-held polishing machine to produce a smooth, even and lustrous finish, complete in all respects, as specified and directed by the Engineer-in-Charge. |
| 50 | Supply and fixing in replacement along wall or laying in trench 110mm nominal outside diameter PVC-U SWR (Soil, Waste and Rainwater) single socketed pipes, Type 'B', conforming to IS 13592, in any required length, laid truly to line and gradient with rubber ring joints using approved pipe joint lubricant as recommended by the manufacturer. The work shall include supplying and fixing all necessary fittings such as bends, tees, single and double Y-junctions, double tees, couplers/sockets, reducers, offsets, access fittings, vent cowls, end caps, plugs and other fittings of any angle or radius, with or without access doors, as required for completing the pipeline system. The item shall also include cutting the pipes to the required length, jointing, making necessary connections to the existing or new SWR system, providing proper alignment, testing the completed pipeline for leakage and satisfactory flow, and all labour, tools, plant and incidental works necessary to complete the work in all respects, as specified and directed by the Engineer-in-Charge.Notes:(i) Brackets, clamps, slotted channels, nuts, bolts, anchor fasteners, supporting arrangements and other fixing accessories shall be measured and paid for separately under the relevant BOQ items.(ii) Measurement for payment shall be made for the actual centre-line length of pipe laid, measured along the pipeline alignment between the centre lines of successive fittings, irrespective of the number of joints. No separate payment shall be made for the socket portion of the pipe, insertion length within sockets/joints, or for fittings such as bends, tees, reducers, junctions, couplers, vent cowls and similar fittings, the cost of which shall be deemed to be included in the quoted unit rate. |
| 51 | Supply and fixing in replacement along wall or laying in trench 75mm nominal outside diameter PVC-U SWR (Soil, Waste and Rainwater) single socketed pipes, Type 'B', conforming to IS 13592, in any required length, laid truly to line and gradient with rubber ring joints using approved pipe joint lubricant as recommended by the manufacturer. The work shall include supplying and fixing all necessary fittings such as bends, tees, single and double Y-junctions, double tees, couplers/sockets, reducers, offsets, access fittings, vent cowls, end caps, plugs and other fittings of any angle or radius, with or without access doors, as required for completing the pipeline system. The item shall also include cutting the pipes to the required length, jointing, making necessary connections to the existing or new SWR system, providing proper alignment, testing the completed pipeline for leakage and satisfactory flow, and all labour, tools, plant and incidental works necessary to complete the work in all respects, as specified and directed by the Engineer-in-Charge.Notes:(i) Brackets, clamps, slotted channels, nuts, bolts, anchor fasteners, supporting arrangements and other fixing accessories shall be measured and paid for separately under the relevant BOQ items.(ii) Measurement for payment shall be made for the actual centre-line length of pipe laid, measured along the pipeline alignment between the centre lines of successive fittings, irrespective of the number of joints. No separate payment shall be made for the socket portion of the pipe, insertion length within sockets/joints, or for fittings such as bends, tees, reducers, junctions, couplers, vent cowls and similar fittings, the cost of which shall be deemed to be included in the quoted unit rate. |
| 52 | Supply and fixing in replacement 75mm bore cast iron soil waste and vent pipe (sand cast pipe) in any length with or without ears, fixed to wall, filling the joints with cement complete all as specified and as directed by Engineer-in-charge. |
| 53 | Supply and fixing in replacement 100mm bore cast iron soil waste and vent pipe (sand cast pipe) in any length with or without ears, fixed to wall, filling the joints with cement complete all as specified and as directed by Engineer-in-charge. |
| 54 | Supply & fixing in replacement 75mm bore CI branch pieces single (equal or unequal), ordinary or inverted (Spigot or socket type) filling the joints with cement complete all as specified and as directed by Engineer-in-charge. |
| 55 | Supply & fixing in replacement 75mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified and as directed by Engineer-in- charge. |
| 56 | Supply & fixing in replacement 100mm bore CI branch pieces single (equal or unequal), ordinary or inverted (Spigot or socket type) filling the joints with cement complete all as specified and as directed by Engineer-in-charge. |
| 57 | Supply & fixing in replacement 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified and as directed by Engineer-in- charge. |
| 58 | Demolition of cement concrete and digging out (unreinforced) including existing floor tiles and sub base, and filling as in sunken floor of any description and in any position and including removing rubbish material from building and thrown in low lying empty area at any distance as directed from the site complete all as specified and as directed by Engineer-in-Charge. |
| 59 | Material and labour for water proofing treatment to RCC sunken slab and adjoining vertical surfaces as specified as under and as directed by Engineer-in-Charge:-(a) Providing 10 mm thick cement plaster/rendering in cement mortar (1:3), finished even and smooth without using extra cement including mixed with liquid waterproofing compound (WPC) on complete vertical and horizontal surfaces of sunken portions(b) Creating fillet covering of 50x50 mm with polymer modified mortar on the junction of slab and walls.(c) Apply first coat of two component modified polymer coating on the horizontal and vertical surface.(d) Provision of glass fiber mesh of 2x2 mm immediately on above coating.(e) Apply second coat of two component modified polymer coating after 72 hrs of above coating.(f) Joining the sanitary pipes with the waterproofing tape having bridging ability of more than 1.5mm (h) Filling the gap between the wall opening and sanitary pipe with non-shrink cementitious grout |
| 60 | Material & Labour for PCC (1:5:10) type E-2 using 40mm graded stone aggregate as in filling of sunken and mass concrete complete all as specified and as directed. |
| 61 | Taking up or down Steel Tubing 15mm bore (dia) with Fittings/ Connections, complete all as specified and as directed.Note :- (i) If a concealed pipe is fixed/laid at the same location from where the old pipe is being removed, the cost for cutting chases in the wall and making it suitable for fixing the new pipe, as required, shall be deemed to be included in the quoted unit rate. Nothing extra shall be paid on this account.(ii) Where concealed pipe laying is carried out at a new location (other than the location of the removed old pipe), cutting chases in the wall shall be measured and paid for separately under the relevant item of the BOQ. |
| 62 | Taking up or down Steel Tubing 20mm bore (dia) with Fittings/ Connections, complete all as specified and as directed.Note :- (i) If a concealed pipe is fixed/laid at the same location from where the old pipe is being removed, the cost for cutting chases in the wall and making it suitable for fixing the new pipe, as required, shall be deemed to be included in the quoted unit rate. Nothing extra shall be paid on this account.(ii) Where concealed pipe laying is carried out at a new location (other than the location of the removed old pipe), cutting chases in the wall shall be measured and paid for separately under the relevant item of the BOQ. |
| 63 | Re-fixing old serviceable 15mm bore galvanised steel water tubing (GI pipe) but new fittings like elbow, tee, union, socket, reducer etc. in new or old portion/position to walls, ceiling, floor etc complete all as specified and as directed.Note :- (i) Old serviceable pipe obtained from taking up or down (here-in-before) item of this BOQ shall be reused after necessary cleaning internally and rerunning the old screw threads as required. |
| 64 | Re-fixing old serviceable 20mm bore galvanised steel water tubing (GI pipe) but new fittings like elbow, tee, union, socket, reducer etc. in new or old portion/position to walls, ceiling, floor etc complete all as specified and as directed.Note :- (i) Old serviceable pipe obtained from taking up or down (here-in-before) item of this BOQ shall be reused after necessary cleaning internally and rerunning the old screw threads as required. |
| 65 | Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling or laid in floor including cutting and threading of pipe complete all as specified and as directed. |
| 66 | Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling or laid in floor including cutting and threading of pipe complete all as specified and as directed. |
| 67 | Material and labour for supplying, hoisting and fixing rotational moulded, double-layer, vertical cylindrical polyethylene (PE) water storage tank with closed top, conforming to IS 12701:1996 (with latest amendments), UV stabilised and suitable for potable water storage, having white inner layer and black outer layer (outer layer minimum of 50% of the total wall thickness), of 500 litres capacity, complete with threaded inlet, outlet, overflow and drain connections with necessary adaptors, tank lid with locking arrangement or threaded type as per manufacturers, and all necessary fittings, supports, nuts, bolts, washers and jointing materials, testing for watertightness, including dismantling/taking down old water storage tanks of any description and capacity with float valve complete all as specified and as directed. |
| 68 | Material and labour for supplying, hoisting and fixing rotational moulded, double-layer, vertical cylindrical polyethylene (PE) water storage tank with closed top, conforming to IS 12701:1996 (with latest amendments), UV stabilised and suitable for potable water storage, having white inner layer and black outer layer (outer layer minimum of 50% of the total wall thickness), of 1000 litres capacity, complete with threaded inlet, outlet, overflow and drain connections with necessary adaptors, tank lid with locking arrangement or threaded type as per manufacturers, and all necessary fittings, supports, nuts, bolts, washers and jointing materials, testing for watertightness, including dismantling/taking down old water storage tanks of any description and capacity with float valve complete all as specified and as directed. |
| 69 | Supply and fixing ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed. |
| 70 | Supply and fixing in replacement ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed Please Enable Macros to View BoQ information |
| 71 | Supply and fixing in replacement ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender