Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #58281122

Tender For special Repair To Central Ac Plant And Repair Replacement Of Ber Cooling Appliances At Af Stn Vadsar

Issued by Statutory Bodies & Commissions/Committees · Gandhinagar, Gujarat
Tender Value
42.93 Lakhs
Estimated cost
Bid Submission
26 Nov 2026
5 days left
EMD
85860
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gandhinagar → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Central Ac Plant And Repair Replacement Of Ber Cooling Appliances At Af Stn Vadsar

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 19-Nov-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-Nov-2026

BOQ

Name of Work:- SPL REPAIR TO CENTRAL AC PLANT AND REPAIR REPLACEMENT OF BER COOLING APPLIANCES AT AF STN VADSAR
Sl. No. Item Description
1Supply and fixing in replacement of Compressor (Danfoss) of 22 TR Capacity complete including testing on complete all as specified and directed by Engr-in-Charge.
2Supply and fixing in replacement of Controller and display set including installation of new software and microprocessor based Control card for control system for Screw chiller of Central AC plants (AC Plant Make - voltas) of capacity 85 TR of existing make & model complete all as specified and directed by Engr-in-Charge.
3Supply and fixing in replacement of Expansion Valve as per existing make & model complete all as specified and directed by Engr-in-Charge.
4Supply and fixing in replacement of Low pressure transducer switch (LP Switch) as per existing make & model complete all as specified and directed by Engr-in-Charge.
5Supply and fixing in replacement of High pressure transducer switch (HP Switch) as per existing make & model complete all as specified and directed by Engr-in-Charge.
6Material & Labour for charging of refrigerant gas R-407c including opening and re-assembling of connected acessories of central AC plant of capacity 85 TR, complete all as specified and directed by Engr-in-Charge.
7Supply and fixing in replacement of cooling tower finges as per existing make & model complete all as specified and directed by Engr-in-Charge.
8Material & Labour for descaling of complete condenser units for central AC plants (AC Plant Make- voltas) of capacity 85 TR by means of adding descaling chemical solution (HCL) or equivalent as per requirements and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and re fixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. complete all as specified and directed by Engr-in-Charge.Note:- Descaling shall be carried out in supervision of Engineer from authorised agency of OEM complete all as specified and directed by Engr-in-Charge.
9Supply, fabricate and erect PGI Air duct made out of 22 gauge PGI sheet including necessary support, jointing with suitable size MS Angle/flat iron and 3mm thick rubber packing, drilling and necessary GI nuts, bolts & washers all as specified and directed, from ground level to upto 50ft height complete all as specified and directed by Engr-in-Charge.
10Supply, fabricate and erect PGI Air duct made out of 24 gauge(Duct) PGI sheet including necessary support, jointing with suitable size MS Angle/flat iron and 3mm thick rubber packing, drilling and necessary GI nuts, bolts & washers all as specified and directed, from ground level to upto 50ft height complete all as specified and directed by Engr-in-Charge.
11Supply, fabricated and erect PGI Air duct made out of 20 gauge(For AHU ) PGI sheet including necessary support, jointing with suitable size MS Angle/flat iron and 3mm thick rubber packing, drilling and necessary GI nuts, bolts & washers all as specified and directed, from ground level to upto 50ft height complete all as specified and directed by Engr-in-Charge.
12Material & Labour for insulation to supply air duct with 25 mm thick rockwool/mineral wool slab covered with chicken wiremesh tissue paper and 24/26gauge aluminium sheet cladding work including taking down old unsv insulation complete all as specified and directed by Engr-in-Charge.
13Material & Labour for insulation to supply air duct for OT AHUS with 20 mm thick armafex insulation covered with armaflex insulation using SR 505 fevicol solution complete all as specified and directed by Engr-in-Charge.
14Material & Labour for insulation to 3x85 TR chillar unit with 25 mm thick armafex insulation covered with armaflex insulation using SR 505 fevicol solution complete all as specified and directed by Engr-in-Charge.
15Supply & Fixing in replacement of aluminium powder coated supply air diffuser minimum 22 gauge with volume control damper including taking down old unsv diffuser complete all as specified and directed by Engr-in-Charge.
16Supply & Fixing in replacement of aluminium powder coated return air linear diffuser minium 22 gauge complete all as specified and directed by Engr-in-Charge.
17Supply & Fixing in replacement butter fly valve of dia 100mm suitable for condensing /chiller water line with ISI marked including jointing with proper gasket, nuts, bolts & washer complete all as specified and directed by Engr-in-Charge.
18Supply & Fixing in replacement butter fly valve of dia 150 mm suitable for condensing / chiller water line with ISI marked including jointing with proper gasket, nuts, bolts & washer complete all as specified and directed by Engr-in-Charge.
19Supply & Fixing in replacement NRV of dia 150 mm suitable for condensing /chiller water line with ISI marked including jointing with proper gasket, nuts, bolts & washer complete all as specified and directed by Engr-in-Charge.
20S & F of water pressure gauge 4\\" dial type with cock 0-14 Kg/Sqmtr complete all as specified and directed by Engr-in-Charge.
21S & F of refrigerant pressure gauge 4\\" dial type with cock 30 to 150 PSI complete all as specified and directed by Engr-in-Charge.
22S & F of refrigerant Temp. gauge 4\\" dial type cock 0C to 50 Ccomplete all as specified and directed by Engr-in-Charge.
23Servicing and de-scaling of FRP cooling tower induced draft counter flow of dimension 2855x3100x3850mm of Central AC plants (AC Plant Make - voltas) of capacity 85 TR complete with chemical solution as recommended by manufacturer with rods and wire brushes complete all as specified and directed by Engr-in-Charge.
24Supply, install, testing and commissioning of high wall split type air conditioner unit indoor/outdoor complete with cordless remote control unit and within built air ioniser and plasma filter for better indoor quality and EER 5.2 of cap 1.5 TR 5 star rating including stand and PVC drain pipe of Aprox 10 mtr long complete incl taking down old insv AC complete all as specified and directed by Engr-in-Charge.
25Supply, install, testing and commissioning of high wall split type air conditioner unit indoor/outdoor complete with cordless remote control unit and within built air ioniser and plasma filter for better indoor quality and EER 5.2 of cap 2.0 TR 5 star rating including stand and PVC drain pipe of Aprox 10 mtr long complete incl taking down old insv AC complete all as specified and directed by Engr-in-Charge.
26M & L for concealed sub main wiring complete with PVC insulated FRLSH cable of 2 run of single core 04 Sqmm 1100 volts grade with unseathead multistranded copper coductor (for phase and neutral) drawn through and including PVC med grade conduit with accessories and 1 run of 4 sqmm 1100 volts grade with unseathead multistranded FRLSH copper coductor (for earthing) complete all as specified and directed by Engr-in-Charge. Note :- (a) two run of 4 Sqmm multistranded FRLSH copper conductor and one run of 4 Sqmm multistranded FRLSH copper conductor and one run of 20 mm dia med grade PVC conduit shall be measured adn paid as one run length. Colour coding for wiring shall be followed as per direction of Engr-in-Charge.(b) The rate quoted by contractor shall be included for chess cutting of the existing wall/surface for concealed wiring and making good the disturbed surfaces to match with the existing wall/surfaces
27S & F of single pole and neutral enclosure with a two pin and earth plug socket complete with one single pole MCB of 20 Amp capacity complete all as specified and directed by Engr-in-Charge. Make:- Legrand/L&T/Havells or equivalent as approved by GE. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58281122
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42.93 Lakhs
LAST DATE 26-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Central Ac Plant And Repair Replacement Of Ber Cooling Appliances At Af Stn Vadsar
Basic Detail
Tender No 8517/26-27/E8
Bidding Type Tender
Location
City Gandhinagar
State Gujarat
Key Dates
Publish Date 19 Nov 2026
Submission Date 26 Nov 2026
Open Date 28 Nov 2026
Finance
Tender Value 42.93 Lakhs
Tender Fee 500
EMD 85860
Exemption Available
Document List
9dcbd9d7-48d0-48e2-8fc9-44a01fde27b1.html
BOQ_893101.xls
Tenderdocument8517.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 26, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Nov 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

9dcbd9d7-48d0-48e2-8fc9-44a01fde27b1.html

xls

BOQ_893101.xls

pdf

Tenderdocument8517.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender