Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #58281119

Tender For Special Repair/Replacement To Transformer Against Ber At Af Stn Gorakhpur

Issued by Statutory Bodies & Commissions/Committees · Gorakhpur, Uttar Pradesh
Tender Value
72.53 Lakhs
Estimated cost
Bid Submission
26 Nov 2026
5 days left
EMD
1.33 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gorakhpur → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair/Replacement To Transformer Against Ber At Af Stn Gorakhpur

BOQ

Name of Work:- SPECIAL REPAIR/REPLACEMENT TO TRANSFORMER AGAINST BER AT AF STN GORAKHPUR
Sl. No. Item Description
1Taking down existing BER Transformer of any type and capacity (50 to 630 KVA) from the existing platform including disconnecting all electric connections, transporting and depositing the Transformer to MES Store Yard including taking down Cable Box and of any size and description including use of necessary T&P and making good disturbed surfaces complete all as specified and as directed.
2Supply, insatllation, testing and commissioning of step down transformer of capacity 630 KVA outdoor type complete with stranded fitting accessories, HT 11 KV, 3 Phase 4 wire, LT 433 Volt, 3 Phase 4 wire with off load changer on primary side to carry secondary voltage + 7.5 % with tappings at every 2.5 % all as per latest IS 1180-2014 level 2, copper wound oil cooling with fins vector Group: DYN 11, including initial oil filling complete all as specified and as directed including the following accessories:-(a) Three numbers of porcelain bushing , 11 KV with brass bushing rods, nuts, bolts and washers etc inside cable and box. (b) one cable box LT side consisting of 4 Nos porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 core LT under ground cables.(c) Oil conservator with filter type drain valve and oil level gauge.(d) Dehydrating breather with first fill of dehydrating agent.(e) Explosion vents.(f) Thremometer pocket on tank cover (g) one number 100 mm dia, dial type thermometer vapour pressure type having range 0 to 120 degree centrigrade.(h) Rating plate and terminal marking plate.(j) Earthing arrangement.(k) Oil drain filter valve.(l) Oil drain valve.(m) Lifting hook.(n) Oil conservator with filling hole cap.(o) Air release valve Plug.(p) Four plate solid cast steel detachable rollers.(r) Extanded bushing LT side disconneting chamber with suitable copper busbar to adpt the multiple cables jointing and Any other misc accessories as per manufacturer's instruction including testing.
3Supply, insatllation, testing and commissioning of step down transformer of capacity 500 KVA outdoor type complete with stranded fitting accessories, HT 11 KV, 3 Phase 4 wire, LT 433 Volt, 3 Phase 4 wire with offload changer on primary side to carry secondary voltage + 7.5 % with tappings at every 2.5 % all as per latest IS 1180-2014 level 2, copper wound oil cooling with fins vector Group: DYN 11, including initial oil filling complete all as specified and as directed including the following accessories:-(a) Three numbers of porcelain bushing, 11 KV with brass bushing rods, nuts, bolts and washers etc inside cable and box. (b) one cable box LT side consisting of 4 Nos porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 core LT under ground cables. (c) Oil conservator with filter type drain valve and oil level gauge.(d) Dehydrating breather with first fill of dehydrating agent.(e) Explosion vents.(f) Thremometer pocket on tank cover (g) one number 100 mm dia, dial type thermometer vapour pressure type having range 0 to 120 degree centrigrade.(h) Rating plate and terminal marking plate.(j) Earthing arrangement.(k) Oil drain filter valve.(l) Oil drain valve.(m) Lifting hook.(n) Oil conservator with filling hole cap.(o) Air release valve Plug.(p) Four plate solid cast steel detachable rollers.(r) Extanded bushing LT side disconneting chamber with suitable copper busbar to adpt the multiple cables jointing and Any other misc accessories as per manufacturer's instruction including testing
4Supply, insatllation , testing and commissioning of step down transformer of capacity 315 KVA outdoor type complete with stranded fitting accessories, HT 11 KV, 3 Phase 4 wire, LT 433 Volt, 3 Phase 4 wire with off load changer on primary side to carry secondary voltage + 7.5 % with tappings at every 2.5 % all as per latest IS 1180-2014 level 2, copper wound oil cooling with fins vector Group: DYN 11, including initial oil filling complete all as specified and as directed including the following accessories:- (a) Three numbers of porcelain bushing , 11 KV with brass bushing rods,nuts, bolts and washers etc inside cable and box. (b) one cable box LT side consisting of 4 Nos porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 core LT under ground cables. (c) Oil conservator with filter type drain valve and oil level gauge. (d) Dehydrating breather with first fill of dehydrating agent.(e) Explosion vents. (f) Thremometer pocket on tank cover (g) one number 100 mm dia, dial type thermometer vapour pressure type having range 0 to 120 degree centrigrade. (h) Rating plate and terminal marking plate. (j) Earthing arrangement.(k) Oil drain filter valve. (l) Oil drain valve. (m) Lifting hook. (n) Oil conservator with filling hole cap. (o) Air release valve Plug.(p) Four plate solid cast steel detachable rollers. (r) Any other misc accessories as per manufacturer's instruction including testing
5Supply, Installation, testing and commissioning of indoor type of oil cooled isotation transformer 200 KVA step-III, IS-2026 Three phase, metalic body unbalanced type, copper wound with standard fitings and accessiones, input voltage of 415 volt , output voltage 415 volt IP-35, vector group Dyn-11, of frequency 50Hz and with following description including first fill of transformer Oil IS 335 ISI marked :-(a) Method of cooling air cooled (b) Rato-1:1 (c) Insulation class-Class E (d) Winding Temperature-Less than 55 C (e) Full load losses Less than 5% (f) No load tosses Less than 0.5% (h) Potential difference between Earth to Neutral voltage- Less than 01 voltNote:- (a) in addItion to the above all standard fittings to be provided as per ISI norms.
6Supply, insatllation, testing and commissioning of step down transformer of capacity 100 KVA outdoor type complete with stranded fitting accessories, HT 11 KV, 3 Phase 4 wire, LT 433 Volt, 3 Phase 4 wire with off load changer on primary side to carry secondary voltage + 7.5 % with tappings at every 2.5 % all as per latest IS 1180-2014 level 2, copper wound oil cooling with fins vector Group: DYN 11, including initial oil filling complete all as specified and as directed including the following accessories:-(a) Three numbers of porcelain bushing , 11 KV with brass bushing rods,nuts, bolts and washers etc inside cable and box.(b) one cable box LT side consisting of 4 Nos porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 core LT under ground cables.(c) Oil conservator with filter type drain valve and oil level gauge.(d) Dehydrating breather with first fill of dehydrating agent.(e) Explosion vents.(f) Thremometer pocket on tank cover (g) one number 100 mm dia, dial type thermometer vapour pressure type having range 0 to 120 degree centrigrade.(h) Rating plate and terminal marking plate.(j) Earthing arrangement.(k) Oil drain filter valve.(l) Oil drain valve.(m) Lifting hook.(n) Oil conservator with filling hole cap.(o) Air release valve Plug.(p) Four plate solid cast steel detachable rollers.(r) Any other misc accessories as per manufacturer's instruction including testing
7S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm 3 Core complete all as specified and directed.
8S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm 3 Core complete all as specified and directed.
9Excavation in trenches in soft/ loose soil not exc. 1.5 metre wide and not exc. 1.50m deep for HT under ground cable/pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed.
10Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft/ loose soil, complete all as specified and directed.
11Removing excavated material in soft/ loose soil n'exc 50 Mtr and depositing where directed at a level not exc 1.5 Mtr above the starting point, complete all as specified and directed.
12M&L for sand cushioning to U/G cable in layers of 23 cm thick ( 8 Cm before laying the cable and 15 Cm thick after laying the cable) in trenches complete all as specified and directed. Note:- Only Punned thickness volume shall be measured.
13Supply and laying un-reinforced precast concrete cable cover, class HV, Type I, flat size 300 mm x 180 mm x 40 mm laid dry for protection of UG cable complete all as specified and directed.
14Dismantling / Taking out unserviceable HT/LT cables for replacement of any size from any position i.e ground / walls / poles / culverts etc complete with protection pipe all as specified and directed.( Note : Earth work shall be measured and paid separately)
15Supply, laying , jointing and testing (in replacement) of HT XLPE cable 95 Sqmm 3 core, 11000 volt screened, PVC 'E' grade insulated bedded, galvanised steel (Heavy duty) strip armoured with aluminium conductor 11 KV pressure earth system confirming to IS-7098(Part-I) 1977 and part-II of 1985 laid in pipe /ducts/trenches, under floor and road or fixed to wall etc complete cross-sectional area of cable 95 sqmm 3 core, all as specified and directed.
16Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 630 Sqmm 3.5 core all as specified and directed.
17Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core all as specified and directed.
18Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 120 Sqmm 3.5 core all as specified and directed.
19Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 95 Sqmm 3.5 core all as specified and directed.
20Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item
21S&F of 80 mm bore GI Tubes, 'light grade', galvanised, with all fitting; laid in trenches complete all as specified.
22M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No. 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable earthing (above GL only) complete all as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58281119
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 72.53 Lakhs
LAST DATE 26-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair/Replacement To Transformer Against Ber At Af Stn Gorakhpur
Basic Detail
Tender No 87653/C/E8
Bidding Type Tender
Location
City Gorakhpur
State Uttar Pradesh
Key Dates
Publish Date 29 Oct 2026
Submission Date 26 Nov 2026
Open Date 03 Dec 2026
Finance
Tender Value 72.53 Lakhs
Tender Fee 1000
EMD 1.33 Lakhs
Exemption Available
Document List
a8a414b6-fd5b-4780-9dcc-330fafc0bbf4.html
BOQ_893227.xls
tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Dec 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

a8a414b6-fd5b-4780-9dcc-330fafc0bbf4.html

xls

BOQ_893227.xls

pdf

tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender