Tender For Provision Of Elevated 04 Ane Post At Bhandrakut Under Age (I) Bhalra
Tender Value
19.47 Lakhs
Estimated cost
Bid Submission
19 Nov 2026
19 days left
EMD
39000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Doda → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Elevated 04 Ane Post At Bhandrakut Under Age (I) Bhalra
BOQ
| Sl. No. | Item Description |
| 1 | BUILDING WORK |
| 2 | Excavation over area not exc 1.50m deep and getting out in any type of soil by mechanical means including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, complete all as specified and directed. |
| 3 | Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed. |
| 4 | Cement concrete 1:3:6 type C-2, using 40 mm graded crushed stone aggregates in foundation filling and mass concrete complete all as specified and directed. |
| 5 | RCC M-25 Design mix as in foundations including raft footing, foundation beam and plinth beam, bases of column complete all as specified and directed. |
| 6 | RCC M-25 Design mix as in column, pillar, piers, post and struts etc., complete all as specified and directed. |
| 7 | RCC M-25 design mix using 20 mm graded crushed stone aggregate as in beam, lintel beam etc., complete all as specified and directed. |
| 8 | RCC M-25 Design mix in slab supported on wall, beam and column in floor, roof, landing, balcony, canopies, deck slab and in slaves and like complete all as specified and directed. |
| 9 | Formwork to sides of concrete foundation ,footing, base of column and raft beam sides and soffit of plinth beam complete all as specified and directed. |
| 10 | Formwork to sides of pillar, post, struts, piers, column square, rectangular or polygonal rough finished surface of concrete complete all as specified and directed. |
| 11 | Formwork to sides and soffit of floor or roof beam launchings, girder, bressumers etc., complete all as specified and directed. |
| 12 | Formwork to soffits of suspended slab such as roof slab, floor slab landing and similar work complete all as specified and directed. |
| 13 | Formwork to edges of concrete flat, treads window cills etc., complete all as specified and directed. |
| 14 | TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 15 | TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 16 | Brick work with old size bricks, straight or curved on plan exceeding 6m mean radius with old size bricks built in cement mortar 1:6 complete all as specified and directed. |
| 17 | 10 mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 and finished even and fair without using extra cement, complete all as specified and directed. |
| 18 | 15 mm thick rendering on other than fair faces of brick surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and directed. |
| 19 | 5mm thick plastering on ceilling concrete surfaces in CM 1:3 even and smooth without using extra cement complete all as specified and directed. |
| 20 | Preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed. |
| 21 | All as per srl item No-1.19 here-in-before but for ceiling complete all as specified and directed. |
| 22 | Preparation of newly plastered surfaces of walls or concrete surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 23 | Hardcore of broken bricks of gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 24 | 100 mm thick PCC 1:4:8 type D-2, using 40mm graded crushed stone aggregates for sub base in flooring complete all as specified and directed. |
| 25 | 50 mm thick PCC 1:2:4 type B-1, using 20mm graded crushed stone aggregates for flooring complete all as specified and directed. |
| 26 | 50 mm thick PCC 1:3:6 type B-1 using 20mm graded crushed stone aggregates as in plinth protection complete all as specified and directed. |
| 27 | 25 mm thicK PCC M-15 (nominal Mix) cement concrete 1:2:4 type B-0 using 12.50mm graded crushed stone aggregates as in sub base of floor complete all as specified and directed. |
| 28 | Machine cut kota stone slab flooring 20mm-25mm thick over and including cement screed base 15mm thick in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 29 | All as per srl item No-1.27 here-in-before but but on vertical surface such as riser, skirting over and including backing layer 15mm thick in CM 1:3 complete all as specified and directed. |
| 30 | Mild steel, plain black sheet in steel gates/ doors cut to size, holes punched, including round headed screw, clout nails or rivets and fixed to steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles etc, as required complete all as specified and directed. |
| 31 | Framed work (Fe 410-W (Grade E-250 quality A) in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging, also fastening and fixing complete all as specified and directed. |
| 32 | Stairs (framed) (Fe 410-W (Grade E-250 quality A) including stringers, treades, landing, balausters, hand rails etc., including cleats, brackets, etc. complete all as specified and directed. |
| 33 | Two coat of synthetic enamel paint tint over primer as red oxide, zinc crome after preparation of new surfaces of steel of any description, not exc 10cm in width or girth when unconnected with other painting or when painted in a different tint complete all as specified and directed. |
| 34 | INTERNAL ELECTRIC SUPPLY |
| 35 | Point wiring with and including 1.5 Sqmm (nominal area) PVC insulated multistranded copper conductor FRLS in and including PVC casing and caping not less then 20 mm dia with all accessories as required at site including with its fittings and fixture such as ties, bends, elbows and juction boxes etc with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing and common earth terminal, One light point controlled by one way switch complete all as specified and directed. |
| 36 | All as per item srl No-2.01 here-in-before but one 3/5 pin socket outlet, 5 amps, on independent board, with cables 1.5 Sqmm size with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing complete all as specified and directed. |
| 37 | All as per item srl No-2.01 here-in-before but one 5 pin socket out let, 15 Amps, on independent board, with cables 2.5 Sq mm size with 2.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing complete all as specified and directed. |
| 38 | LED tube light fittings 1 x 20 watts with LED tube complete, fixing on recess/surfaces etc., complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible cable of 0.75 Sqmm 3 core copper conductor from ceiling rose to light fittings complete all as specified and as directed. |
| 39 | Switch piano type 5 Amp flush button single pole one way, fixed in repairs complete all as specified and directed. |
| 40 | Switch socket combination 2 in 1, 5 pin, 5 Amp flush type universal, fixed in repairs complete all as specified and directed. |
| 41 | Switch socket combination 5 in 1, 3 pin, 5 and 15 Amp flush type universal, fixed in repairs complete all as specified and directed. |
| 42 | Ceiling rose, 3 phase/PVC/Polycarbonate, isolated body, fixed in repairs complete all as specified and directed. |
| 43 | MCB 6 Amps to 32 Amps SP 'C' series 240 V, 50 Hz, breaking capacity 10 KA suitable for lighting and other domestic loads, fixed in repairs complete all as specified and directed. |
| 44 | MCB 32 Amps SPN 'C' series 240 V, 50 Hz, breaking capacity 10 KA, fixed in repairs complete all as specified and directed. |
| 45 | Sheet metal enclosure for DBs double door when MCBs to be used Single pole and neutral with 200 Amps rated bus bar 240 V, 4 Way, fixed in repairs complete all as specified and directed. |
| 46 | Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete with all accessories internally pre-wired and including plug for connecting up with 5 Amp socket complete all as specified and directed. |
| 47 | Earthing complete with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC chamber of size 300mm x 300mm x 300mm (inside dimension) in 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia light grade for watering complete, all excavation and earth work in any type of soil and connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete all as specified and directed. |
| 48 | PATHWAY |
| 49 | Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed. |
| 50 | Hardcore of broken stone or boulders gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 51 | 100 mm thick cement concrete 1:4:8 type D-2, using 40 mm graded crushed stone aggregates in pavments complete all as specified and directed. |
| 52 | Fine dry river sand filling under floors, watering, leveling and consolidating complete all as specified and as directed.Note: Only consolidated thickness of sand shall be considered for measurement purposes. |
| 53 | Machine pressed precast concrete interlocking paverblock any shape and size conforming to IS 15658-2006 of 80 mm thickness M-40 grade with grey cement and pigment complete all as specified and directed. |
| 54 | Removing of excavated material not exc 50m and depositng where directed at a level not exc 1.5 m above the starting point in any type of soil, complete all as specified and directed. |
| 55 | EXTERNAL ELECTRIC SUPPLY |
| 56 | 400W LED search Light with automatic 360° rotation and manual control alongwith panel, extendable stainless steel tripod, motor and all other accessories required for smooth functioning of system complete all as specified and directed. |
| 57 | Supply Laying, jointing with suitable thimble and cable gland, testing and commissioning or fixing in wall or passing through pipe, 1100 Volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor cable of size 16 Sqmm 4 core, 1100 Volts, grade complete all as specified and directed. |
| 58 | 1100 volts grade heavy duty cable with PVC insulated aluminiuum stranded conductor served with an inner sheating of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1.0 mtr apart including 4mm suspention wire one twin core 16 Sqmm solid conductor complete all as specified and directed. |
| 59 | Bus bar Panel, size: 0.8m x 0.4m x 0.4m, Kiosk outdoor type, CPRI approved, LT 440 Volts, 50 Hz , 3 phase 4 wire supply, floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.15 mm thick MS Sheet CRCA on angle iron 30mm x 30mm x 4mm frame of size suitable to incorporate following accessories with front opening doors, locking arrangement, MCB TPN 32 Amp-01 No as incomer and MCB SPN 32 Amp-02 Nos as outgoing, powder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 type C-2, using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engineer-in-charge including earth work complete comprising of Bus bar chamber comprising 4 Nos Aluminium strip bus bars PVC insulated made of aluminium strip of size suitable for 200A current. PVC sheathed with colour coding complete all as specified and directed. |
| 60 | Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr but n.exc 3.0 mtr in depth and getting out in any type of soil for taking up or laying of cable, foundation of poles, stay etc complete all as specified and directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material and labour is deemed to be included in the cost of excavation. |
| 61 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layers complete all as specified and directed. |
| 62 | Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 63 | Sand cushioning to under ground cable laid in trenches for laying of HT/LT underground cables 8 cm wide before laying the cable and 15 cm after laying and punned down to a depth of 10 cm as per MES SSR Part-I (2009) complete all as specified and directed.Note: Punned thickness shall be measured and paid to the contractor. |
| 64 | Sub class ‘B' brick, for cable protection cover, laid dry, flat, transversally along the length of cable with width equal to the length of the brick, complete all as specified and directed. |
| 65 | Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth strip 25mm x 4mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate with fair finish, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 3 of MES SSR Part-I (2020) as specified including provision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete, all excavation and earth work and connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysNov 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender