Tender For Provn Of Guard Room At Bsnl Area At Aizawl Mil Stn Under Ge Silchar
Tender Overview
Project Description
Tender for Provn Of Guard Room At Bsnl Area At Aizawl Mil Stn Under Ge Silchar
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-Nov-2026 | Other Corrigendum | Other | 03-Dec-2026 |
| 2 | 17-Nov-2026 | BOQ corrigendum | BOQ | 03-Dec-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | NOTE (Applicable for all parts/items):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 2 | SCHEDULE \\"A\\" Part - I (BUILDING / STRUCTURES WORK ) Details of pre priced schedule is given in tender documents. |
| 3 | SCHEDULE \\"A\\" PART-II (SITE CLEARANCE, EARTH WORK AND SITE DEVELOPMENT) Details of prepriced Schedule is given in tender documents |
| 4 | SCHEDULE \\"A\\" PART-III (ROAD/PATH/CULVERT) Details of prepriced Schedule is given in tender documents |
| 5 | SCHEDULE \\"A\\" PART-IV (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents |
| 6 | SCHEDULE \\"A\\" PART-V (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents |
| 7 | SCHEDULE \\"A\\" PART-VI (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents |
| 8 | SCHEDULE \\"A\\" PART-VII (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents |
| 9 | SCHEDULE \\"A\\" PART-VIII (FENCING & GATE ) Details of prepriced Schedule is given in tender documents |
| 10 | SCHEDULE \\"A\\" PART-IX (RETAINING WALL ) Details of prepriced Schedule is given in tender documents |
| 11 | SCHEDULE \\"A\\" PART -X (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col.' 5 ' signifies this fact only. |
| 12 | Supply and fixing Two way Bib Tap with wall flange and areator, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type, screwed down for iron pipe and fixed etc complete all as specified and as directed. |
| 13 | Material and labour for Soakage Well of size 1.80m dia and 3.0m effective depth including excavation in any type of soil, Foundation in PCC 1:3:6, type C2 with Honeycombed Masonry Walls with top ring in M-30 Grade Design Mix Concrete including Intercepting Chamber and Screen Chamber made of Brick Masonry in Cement Mortar 1:6, RCC Cover Slab in M25 Grade Design Mix Concrete / SFRC Cover interconnecting pipes of RCC/DWC complete filled with brick bats with all ancillaries, fittings, fixtures complete all as specified and as shown on drawings and as directed. |
| 14 | Material and labour septic tanks, exc in any type of soil, foundation in PCC 1:2:4 brick work in CM 1:4 RCC Slab covers including RCC precast manhole cover having 6mm plate embedded all around/fiber reinforced cover with angle iron frame vent shaft and sludge chamber etc, complete for 10 users complete all as specified and as shown on drawings and as directed. |
| 15 | Supply, erection and fixing of 5 Meter high Hot Dip Galvanised (HDG) Octagonal Pole with Top Dia 70mm and bottom Dia 130 mm with pole shaft thickness of 3mm, base plate 200mmx200mmx12mm, hole dimention 24x32mm, with single arm bracket of length 1500mm with 4 number foundation bolts EN8 grade of size M20 x 600 mm long J type as per OEM's directions etc, complete all as specified and as directed. |
| 16 | Supply and fixing 3 core flexible copper conductor 1.5 sqmm from cable junction box to street light fitting including ERW steel conduit pipe of 20mm dia complete all as specified and as directed. |
| 17 | M & L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machinery including HDPE Pipe, 150mm bore, 0.4 Mpa working pressure complete all specified and as directed.Note: The horizontal directional drilling machine boring shall be minimum shot length of 100m horizontal length in a single span and depth shall not be less than 1.20m. The unit rate quoted is deemed to be inclusive for earth work as required at site for boring at starting and termination ends complete all as directed. |
| 18 | Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof LT Panel board, Compartmentalised, Outdoor type, fabricated with 3.15mm thick CRCA Sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of aluminium bus bars of high conductivity of suitable size and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, including instrumentation such as Ampere Meter, Volt Meter, Phase Indicating LED Lamps [RYB], Selector Switches etc with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts Grade, 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and to withstand short circuit fault level of not less than 100KA and degree of protection shall be IP 65.The panel shall be fixed with angle iron frame made of angles of size 40X 40 X 4mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and comprising the following :[a] MCCB, 63 Amps, FP, 16 KA, 415 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 No. [Incoming][d] Aluminium bus bar 400 Amps of suitable size and length duly insulated with colour code-04 Nos.[h] Digital type Ammeter of Range 0 – 500 Amps with CTs & Selector Switch – 4 Nos [1 Set].[j] Digital type Voltmeter of Range 0 – 500 V with Selector Switch – 1 Nos.[k] Colour Coded LED Phase Indicating Lamps for each Phase – 1 Set. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 11 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 11 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender