Tender For special Repair To Roof Treatment And Plinth Protection Basement Work Around The Building To Block No 290 Under Ge Golconda
Tender Overview
Project Description
Tender for special Repair To Roof Treatment And Plinth Protection Basement Work Around The Building To Block No 290 Under Ge Golconda
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) File No 8186/E8 Tender Inviting Authority: GARRISON ENGINEER GOLCONDA Name of Work: SPL REPAIR TO ROOF TREATMENT AND PLINTH PROTECTION BASEMENT WORK AROUND THE BUILDING TO BLOCK NO 290 UNDER GE GOLCONDA Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make No or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder including all TaxesRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | M&L for APP based polymeric membrane minimum weighing 3Kg/sqm and minimum 3 mm thick reinforced with polyester non wove fabric (weight not less than 150 gms/sqm laid over primed surface including bituminous primer conforming to IS -3384 applied @ 0.3 ltrs/sqm by forced application over finished with one coat of aluminum paint @ 100 ml/Sqm, 10 cm overlap fused uniformly by LPG torch flame, including rendering 10mm thick in cm 1:4 on concrete surfaces of roofs, parapet etc. finishing to surfaces even and smooth without using extra cement and providing necessary slope with using approved water proofing liquid @ 200 ml per 50 kg bag of cement complete all as specified and directed. including taking down existing roof treatment and cement plaster of any description, roughing, preparing the surface by cleaning the surface with wire brushing scrubbing down with water to receive new treatment all as specified and directed. (NOTE : Supply of WPC will be paid under the respective Item) |
| 3 | M&L for APP based polymeric membrane minimum weighing 3Kg/sqm and minimum 3 mm thick reinforced with polyester non wove fabric (weight not less than 150 gms/sqm laid over primed surface including bituminous primer conforming to IS -3384 applied @ 0.3 ltrs/sqm by forced application over finished with one coat of aluminium paint @ 100 ml/Sqm, 10 cm overlap fused uniformly by LPG torch flame, including taking down existing roof treatment on parapet walls, preparing the surface by cleaning with wire brushing, scrubbing down with water to receive new treatment complete all as specified and as directed. |
| 4 | Demolition of cement concrete on roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work etc complete all as specified and as directed. |
| 5 | M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in roof padding finished even and smooth using extra cement with WPC complete all as specified and directed. (NOTE : Supply of WPC will be paid under the respective Item) |
| 6 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 7 | M & L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 (for water proofing). complete all as specified and as directed. |
| 8 | S&F for 110 mm PVC (SWR) pipes as in spout /rain water pipes single socketed in any length with rubber ring joints fixed to wall including taking down existing pipe complete all as specified and as directed. |
| 9 | S&F in repair PVC (SWR) bends any radius 110 mm dia complete all as specified and directed. |
| 10 | S & F in repair PVC (SWR) junction single, (Single T) equal or unequal any radius, 110 mm dia, complete all as specified and directed. |
| 11 | S & F in repair PVC (SWR) branch piece, single (single Y) equal or unequal any radius, 110 mm dia, complete all as specified and directed. |
| 12 | S&F in repair 1000 liters Rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed. |
| 13 | M&L for 75mm thick Cement concrete type C-2, 1:3:6 (Mix with 40, 20mm graded aggregate and fine aggregate Natural river sand) as in plinth protection finishing cement concrete surface even and smooth Without using extra cement and Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green etc complete all as specified and directed |
| 14 | M&L for Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface etc complete all as specified and as directed. |
| 15 | M&L for PCC 1:4:8 Type D2 using 40mm graded stone aggregate Cement concrete in foundations, filling and mass concrete as in sub base complete all as specified and as directed. |
| 16 | M&L for brick work with old size fly ash bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 including demolition of existing complete all as specified and as directed. |
| 17 | M&L for rendering 15mm thick in CM 1:4 with WPC on fair faces of brick surfaces of walls finished the surfaces even & smooth without using extra cement. (NOTE : - WPC will be measured and paid separately) |
| 18 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out Soft/loose soil. , etc complete all as specified and directed. |
| 19 | M&L for chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick with grey cement and pigment, machine pressed, set jointed and pointed in neat cement slurry in floors id over 15 mm thick screed bedding layer in CM 1:6 complete, including dismantling chequered floor tiling including cement mortar bedding complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender