Tender For Special Repair To Bldg No P-216 In Zone H At Agartala Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Taking out complete existing roof treatment from roof surfaces and roughening of surfaces of old concrete roofby picking, sweeping clean and washing down with water to remove dust by air blower and removing rubbish to a distance exceeding 50m as per direction of Engineer-in-Charge complete all as specified and as directed at site. |
| 2 | M&L for making the grooves to 'V' section in existing parapet wall/ column over RCC roofs cleaning out and tacked and insertion of polymeric membrane into the grooves and sealed solidly with a hot mixture of bitumen and clean dry sand in the ratio of 1:1 by weight etc complete all as specified and directed at site. |
| 3 | Material and labour for 10 mm thick screed bed or bedding layer in CM 1:4 in order to maintain proper slope over existing roof surface for applying single component acrylic polymer modified, finished even and fair without using extra cement complete all as specified and as directed t site.(Note: Polymeric membrane shall be measured and paid seprately under relevent item of this Schedule 'A') |
| 4 | Material and labour for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in roof kerb, slightly rounded or chamfered on edges, mixed with water proofing compound in top layer as per manufacturer instruction surface finished even and smooth on exposed concrete surface without using extra cement all complete all as specified and as directed at site.(Note: Liquid WPC shall be measured and paid separately) |
| 5 | M & L for cleaning newly plastered surfaces of roof to receive the water proofing membrane, applying a coat of bitumenous primer @ 0.40 ltrs per sqm and applying a layers of APP based polymeric membrane, 3mm thick (minimum) weight 3.50 Kg/sqm reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) shall be applied over Bitumenious primer (Application of polymeric memberane shall be by torch sealed application, over laps shall be minimum 100mm on the transverse direction & 75 mm on the longtudinal direction) polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by membrane flashing, coved fillet in PCC (1:2:4) type B-0 of radius 75 mm shall be provided at the junction of roof & other vertical surfaces & surfaces shall be painted with applying one coat of aluminium paint over the APP modified membrane @ 0.11 kg/sqm complete all as specified and as directed at site. |
| 6 | Material and labour in repair light shade vitrified cerimic coloured tile 10mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.18 Sqm but not exc 0.38 Sqm in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match the tile including applying screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:6 complete all as specified and as directed at site. Note: The colour / shade / design of tiles shall be as approved by AGE(I). |
| 7 | Material and labour in repair light shade vitrified coloured tile 10mm thick of premium quality, area of each tile not exceeding 0.36 sqm on skiriting/dado, set & jointed in neat cement slurry & pointed with white/coloured to match over and including screed bed of 10mm thick in Cement Mortar 1:4 complete all as specified and as directed t site. Note: The colour / shade / design of tiles shall be as approved by AGE(I). |
| 8 | Material and labour in repair for brick work with sub class `B` bricks, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and as directed at site. |
| 9 | Taking down cement plaster on brick, concrete surfaces including racking out joints hacking for key, scrubbing down with, water etc complete all as specified and as directed at site. |
| 10 | Material and labour for 15mm thick rendering in CM (1:4) on brick work /concrete surfaces mixed with liquid water proofing compound @ 200ml per bag of cement/ as per manufacturer's instructions and finish the surface even and fair complete all as specified and as directed at site.(Note:Water proofing compound shall be measured & paid separately) |
| 11 | Materials and labour for 10 mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:6) and finish the surface even and smooth without using extra cement complete all as specified and as directed at site. |
| 12 | Material and labour for 5 mm thick rendering in CM (1:3) on fair face of concrete surfaces as in ceiling etc finished the surface even and smooth without using extra cement complete all as specified and as directed t site. |
| 13 | M&L for complete removal of existing treatment on wall surface and finishing wall with two coat of Acrylic Smooth exterior emulsion paint of required shade over a coat of exterior emulsion primer before applying BIRLA/JK wall care putty of 1 mm thick over plaster surface even and smooth, complete all as specified and directed at site. |
| 14 | Material and labour for preparation of newly plastered surface of wall and applying two coat of Acrylic Smooth exterior emulsion paint (APEX) of required shade ,two coats applied @ 1.67 ltr/10 Sqm in two coats over and including priming coat of white cement exterior primer applied @ 2.20 kg/10 sqm on wall surfaces complete all as specified and as directed at site. |
| 15 | Material and labour for preparing newly plastered Wall surfaces and applying two coats of Oil Bound Distemper over a coat of white cement primer over a coat of 1 mm thick Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the Wall surfaces complete all as specified and as directed at site. |
| 16 | Material and labour for Complete removal of existing treatment of any description on wall surfaces and applying 1mm thick Cement based Wall Care Putty on walls including scraping / rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Oil Bound Distemper over one coat of white cement primer on wall surfaces complete all as specified and as directed at site. |
| 17 | Material and labour for preparing newly plastered surface of ceiling, chajjas surfaces and applying three coats of white washing complete all as specified and as directed at site. |
| 18 | Material and labour for washing , rubbing down and stopping of distempered and painted surface of internal ceiling by scraping down and applying two coats of white wash including preparation over old plastered ceiling/ chajjas surface , complete all as specified and directed at site. |
| 19 | Material and labour for Writing letters or figures [Block, Roman, Italic or Indian] not exceeding 30 cm high with thick paint to stand out boldly and solidly without showing signs of brush marks complete all as specified and as directed at site. |
| 20 | Supply only liquid water proofing compound ISI Marked complete all as specified and as directed at site. |
| 21 | Taking down Chowkats or frame with shutters [without taking off shutter from the frame] exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed at site. |
| 22 | Supply and fixing 125x60mm size pressed steel, frames 1.6 mm wall thick for door with one or more rebates including necessary fixing lugs, hinges,lock strike plate, etc, complete all as specified and as directed at site. |
| 23 | Supply and fixing 105x60mm size pressed steel, frames 1.6 mm wall thick for door with one or more rebates including necessary fixing lugs, hinges,lock strike plate, etc, complete all as specified and as directed at site. |
| 24 | Material and labour Plain cement concrete in bed block and filling of door frame type B-0 1:2:4 (12.5 mm graded stone aggregate) complete all as specified . |
| 25 | Supply and fixing for 35mm thick factory made flush door shutters solid core construction with block board core and ply wood face panels commercial type on both faces complete all as specified and as directed at site. |
| 26 | Material and labour for preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed at site.. |
| 27 | Material and labour for preparation of new wooden surface exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed at site. |
| 28 | M&L for cutting holes in brick walls in cement mortar for inserting holdfast and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as requered in Exc. Half brick but n .exc full brick ,complete all as specified and directed at site. |
| 29 | M&L in repair Prelaminated Particle Board exterior grade borded with phenol formed dehyde resin of 25 mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancig white lamination, fixed with screw to timber frame work for cupboard partition, complete all as specified and as directed at site. |
| 30 | M&L in repair Prelaminated Particle Board 18/19 mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancig white lamination, fixed with screw to timber frame work for cupboard partition, complete all as specified and as directed at site. |
| 31 | M&L for extra over rates of block board or veneered partical board for external teak wood lipping, 6mm thick fixed with nails, complete all as specified and directed at site. |
| 32 | Taking down chowkat with shutter without taking off shutter from the frame n.exc 1.50 Sqm each complete all as specified and as directed at site. |
| 33 | Supply and fixing factory made Solid PVC door frame of size 50mmX47mm made out of 5mm woodgrain printed PVC sheet reinforced with MS square tube in opening complete all as specified and as directed at site. |
| 34 | Supply and fixing Factory Made Solid PVC Moulded Door Shutter, with Particle Board Core, 28 to 30mm thick [Stiles], with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm plain colour PVC sheet on back face, termite proof, water proof and fire resistant, supplying & fixing in frame at site as per specification & drawing shown on Serial Page No. 181 of MES Schedule Part - II complete all as specified and as directed at site. |
| 35 | S&F in repair continious (Paino) hinges, mild steel, brigh finish or electro galvanised of 30mm width (when open) , complete all as specified and diretcted at site. |
| 36 | S&F in repair 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed at site. |
| 37 | Supply and fixing 150mm size extruded aluminium alloy handles, fabricated type anodizedcomplete all as specified and as directed at site. |
| 38 | Supply and fixing 125mm size extruded aluminium anodized alloy handles, fabricated type complete all as specified and as directed at site. |
| 39 | Supply and fixing 150mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and as directed at site. |
| 40 | Supply and fixing 200mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and as directed at site. |
| 41 | Supply and fixing Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed at site. |
| 42 | Supply and fixing Butt hinges, stainless steel of 100mm size, complete all as specified and as directed at site. |
| 43 | Material and labour for preparation of old wooden surface exc 10 cm width or girth and applying one coats of synthetic enamel paint , complete all as specified and as directed at site. |
| 44 | S&F in repair 25mm dia stainless steel curtain rods with fixing both side brackets end knobs and fixed with PVC rawl plugs & steel screws etc complete all as specified and directed at site. |
| 45 | S & F in repair Aluminium Powder Coated Three Track (2 glazed & one gauze shutter) Sliding Window Frame (aluminium sections weighing not less than 1.67kg/m for frame) and Shutters (aluminium sections weighing not less than 0.55kg/m for shutter) including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Powder Coated Aluminium Snap Beading, Screws, Powder Coated Aluminium Fittings such as Locking Arrangement [4 Nos], including glazing with 5.5 mm thick Tinted Glass and aluminium Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium beading and making good the surface complete all as specified and as directed at site.Note: (a)The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I.[b] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as locks, 5.5mm thick tinted glass and wire cloth etc. |
| 46 | Supply and fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.00mm and fixed with stainless steel wire staples complete all as specified and as directed at site. |
| 47 | M&L in epair for fabrication and fixing of anodised Powder Coated aluminimum door shutter fixed with rubber gasket, stopper, cleats, handles etc complete for aluminimum frame of size 101.6mm x 44.45mm x2mm and section of bottom and top rail of section 114mmx44.45mmx2mm thick and lock rail shutter frame of 83mm x 44.45mm x2mm with and including panels of 5.0 mm thick plain/froated glass , and with anodised aluminimum snap beading of size 18.2mm x16.66mm scred for fixing fully including all necessary fittings and EPDM rubber packing each shutter shall be provided with two decorative type aluminimum disc handle of 150mm dia per shutter , 1 no heavy duty door closer, 1 no 200 mm long aluminimum tower bolt and 3Nos 125mm long Stainless stell But hinges per shutter ,complete all as specified and directed at site. |
| 48 | Supply and fixing in repair Powder coated aluminium louvered ventilators of size 600X600mm with glass louvers, without sash bars of aluminium sections weighing not less than 0.605kg/m for frame of size 40x20x2mm including necessary jointing cleats, glazing cleats, rubber packing , anodised aluminium snap beading,screws, anodised aluminium fittings and 5.5mm thick frosted tinted glass fixed in panels with suitable locking arrangements and making good the surface complete all as specified and as directed at site.Note: (a)The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I.[b] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as locks, 5.5mm thick tinted glass etc. |
| 49 | Supply and fixing in repairs Vitreous China squatting pan of ‘Orissa pattern’, size 580 mm x 440mm (white) with ‘P’ or ‘S’ trap, front or back inlet and integral foot rests, any pattern complete including provision of PCC bedding and connection to trap, flushing pipe, antisyphonage pipe, etc. including making good the disturbed floor (excluding flushing cistern ) complete all as specified and as directed at site. |
| 50 | Supply and fixing in repairs 10 litre capacity low level PVC flushing cistern (any colour), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete all as specified and as directed at site. |
| 51 | Supply and fixing in repairs vitreous china WHB of size 450x300mm including brackets ,waste fittings, brass, chromium plated with long screwed shanks and flynuts, flange end bedded in red lead cement and other end fixed etc complete all as specified and as directed at site. |
| 52 | Supply and fixing in repair low density polythene (LDPE) pipes of pressure rating 6 Kg/Sq cm bore of tube 32 mm for waste pipe of WHB or sinks etc complete all as specified and as directed at site. |
| 53 | Supply and fix in repair PVC connection 15mm size with PTMT nuts of length 600mm ccomplete all as specified and as directed at site. |
| 54 | Supply and fix as in repair 15 mm bore pillar tap fancy type , cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without letter Hot or Cold with long screwed shanuls and fly nuts, screwed for iron pipe complete all as specified. |
| 55 | Supply and fixing in repairs looking mirror of size 600mm x 450mm x 5mm thick bevelled edge of selected quality glass, decorative type mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers with glass self assembly consisting of 5.5 mm thick sheet glass self 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and as directed at site. |
| 56 | Supply and fixing in repairs 15mm bore angular stop valve fancy type,chromium plated , screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed at site. |
| 57 | Supply and fixing in repairs Brass Chromium Plated Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges complete all as specified and as directed at site. |
| 58 | Supply and fix, as in repair, 15 mm bore bib taps fancy type ,chromium plated, cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed at site. |
| 59 | Supply and fix, as in repair, 15 mm bore chromium plated wall mixer for mixing hot & cold water screwed down for iron pipe and fixed , complete all as specified and directed at site. |
| 60 | Supply and fix in repair 125mm dia CP brass shower rose with swivel joints, any colour including shower arm 15mm dia, 195mm long with bend of 45 degree with flange of CP brass approved complete all as specified and directed at site. |
| 61 | Supply and fixing in repairs Soap dish, vitreous China white of approximate size 160 x 160 x 90 mmcomplete all as specified and as directed at site. |
| 62 | Supply & Fixed in repairs PVC (SWR) floor trap 75 mm outlet diameter, plain with grating including jointing with solvent cement complete all as specified and directed at site. |
| 63 | Supply and fixing in repairs 50mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or innfloors etccomplete all as specified and as directed at site. |
| 64 | S & F in repair UPVC Pipe of 20 mm bore, of pressure rating 10 KGf / Sq.cm including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, sockets etc and fixed to walls, ceiling, and laid on floors including testing complete all as specified and as directed at site. |
| 65 | S & F in repair UPVC Pipe of 15 mm bore, of pressure rating 10 KGf / Sq.cm including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, sockets etc and fixed to walls, ceiling, and laid on floors including testing complete all as specified and as directed at site. |
| 66 | Cutting chases, pinning in, making good to facings where required and pointing in CM(1:3) to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth in brick wall ccomplete all as specified and as directed at site. Note: Cutting of walls will be carried out by using mechanical means like Groove cutter/ wall chaser. |
| 67 | Supply and fixing in repair 500 ltrs capacity rotational moulded polythene three layer water storage tanks (Cylindrical vertical with closed top) hoisted & fixed in position complete all as specified and as directed at site. |
| 68 | Supply and fixing 20 mm bore Ball Valves, high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe [Minimum Weight 20mm - 210 Grams] etc. complete all as specified and as directed at site. |
| 69 | Supply & fixing in repairs gun metal globe or gate valve 20mm dia with iron wheel head screwed both ends for iron pipecomplete all as specified and as directed at site. |
| 70 | Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc including removing from site for taking credit and making good to disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed at site. |
| 71 | M&L for point wiring (concealed type) with PVC insulated 1100 volts grade FRLS unsheathed single core multi-stranded copper conductors 1.5 sqmm (nominal area) for phase, netural and 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable for earth continuty conductor drawn through and including PVC conduit (medium grade) of adequate size with fitting and acessories as required at site including suitable size of GI boxes of thickness not less than 0.8 mm thick and : earth continuty conductor shall be connected to common earth and earth dolly for one light/ fan point controlled by one way switch, complete all as specified and directed at site.NOTE:- For Item No 1 & 2 (i) Cost of cutting of wall , if any for housing of GI box, cealing rose, etc and also making good the disturbed surface are deemed to be included in unit rate.(ii) Cost of GI box suitable size shall be deemed to be included in the qouted rate.(iii) Cost of chase cutting for conduit wiring shall be included in the qouted rate. |
| 72 | All as per item above but for one 3/5 pin 6 Amps socket outlet on the same board with other switches cable 2.5 Sqmm, complete all as specified and directed at site. |
| 73 | All as per item above but for one 3/5 pin 6 Amps socket outlet on the independent board cable 2.5 Sqmm, complete all as specified and directed at site. |
| 74 | M&L for point wiring (concealed type) with PVC insulated 1100 volts grade FRLS unsheathed single core multi-stranded copper conductors 1.5 sqmm (nominal area) for phase, netural and 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable for earth continuty conductor drawn through and including PVC conduit (medium grade) of adequate size with fitting and acessories as required at site including suitable size of GI boxes of thickness not less than 0.8 mm thick and : earth continuty conductor shall be connected to common earth and earth dolly for 3/5 pin 16 Amps socket point on independent board, complete all as specified and directed at site. |
| 75 | M&L for switch socket combination multi purpose 2 in 1 , 5 Pin, 5 and 16 Amps, modular type ISI marked complete all as specified and as directed at site. |
| 76 | M&L for switch modular button 5/6 Amps single pole, 1 way 240 V ISI marked complete all as specified and directed at site. |
| 77 | M&L for switch socket combination 5 pin, 6 Amps modular type ISI marked complete all as specified and as directed at site. |
| 78 | M&L for socket outlet 5 Pin, 6 Amps modular type complete all as specified and directed at site. |
| 79 | S&F ceiling rose surface bakelite with three terminals complete all as specified and directed at site |
| 80 | M&L in repair for electronic fan regulator (modular type 120 W 2 module), AC 240 volt complete all as specified and directed at site. |
| 81 | S&F in repair MCB DB(Double Door) SPN , 12 way sheet steel with bus bar, din rail, netural link and earth bar with fitting & fixtures Complete all as specified and directed at site. |
| 82 | S&F in repair sheet metal enclosure / TPN DBs (Double Door) 4 way with 200 amps rated busbar suitable for MCB complete all as specified and directed at site |
| 83 | S&F in repair MCB triple pole & neutral 63 amps, 240 volts, 10 KA 'C' series with all incoming / out going connection suitable for 4 way type TPN DB in double door with proper size of aluminimum lugs complet all as specified and dircted at site. |
| 84 | Supply and fixing in repair MCB 6 - 32 Amps, SP, 240 Volt \\"B\\" series, breaking capacity 10 KA all incomming/ outgoing connection with proper size of lugs complete all as specified and as directed at site. |
| 85 | Supply and fixing in repair MCB 6 - 32 Amps, SP and neutral, 240 Volt \\"C\\" series, breaking capacity 10 KA all incomming/ outgoing connection with proper size of lugs complete all as specified and as directed at site. |
| 86 | Supply and fixing in repairs LED street light fitting 35 Watt 230 V AC with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver, including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed at site. Note: Light fitting shall be of PF>0.95 |
| 87 | Materials and labour in repair for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing setcomplete all as specified and as directed at site.Notes:-(i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department. |
| 88 | S&F in repair LED light fitting 1x20W, 220V, AC decorative box type with driver ,holder including LED tube light connecting up with three core flexible ciopper conductor cable of suitable size from ceiling rose complete all as specified and directed at site. |
| 89 | S&F inrepair LED light fitting, 1x10/12w bulk head luminaries, with LED lamp, etc. complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size, including taking down the old unserviceable fitting complete all as specified and directed at site. |
| 90 | Material & Labour in repair for sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC Casing/ Caping with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly and including taking down old unserviceable sub main wiring of any description, making good to disturbed surfacescomplete all as specified and as directed at site.Note : (i) 3 Runs of 4.0 Sqmm cable and one run of PVC Casing/ Caping shall be measured as one unit length |
| 91 | Taking down ceiling fan carefully of any size from its original position, kept in safe custody and refixing the fan in same position or at new place including cleaning and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm after repair work completed complete all as specified and as directed at site. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 24 daysDec 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 31 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender