Tender For Maintenance Of Different M.I Schemes Under Charilam R.D Block & Bmc Bishalgarh During The Year 2026-27. / Sh: maintenance Of Upvc Distribution Line, Leakage, Gi Hydrant Post, Sluice Valve Etc. And Other Allied Works Under W.R Sub-Division
Tender Overview
Project Description
Tender for Maintenance Of Different M.I Schemes Under Charilam R.D Block & Bmc Bishalgarh During The Year 2026-27. / Sh: maintenance Of Upvc Distribution Line, Leakage, Gi Hydrant Post, Sluice Valve Etc. And Other Allied Works Under W.R Sub-Division Bishalgarh. Dniet No:- 56/Ee/Wrd-Ii /2026-27
BOQ
| Sl. No. | Item Description |
| 1 | Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm (slope-1 in 200)including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - Charge.A. For UPVC pipes in new work.a. In all kinds of soil.i. For pipes not exceeding 90 mm dia |
| 2 | ii. For pipes exceeding 90 mm dia but not exceeding 300 mm dia |
| 3 | Providing and fitting fixing of different dia rigid UPVC unequal Tee (including earth cutting & backfilling all socketted) suitable for pipes as per IS specification of working pressure 4.0 kg/sq.cm confirming to IS: 10124 (part-V) as per CPWD Specification & direction of Engineerin- charge.Unequal Tee315x315x250 mm dia |
| 4 | 315x315x200 mm dia |
| 5 | 315x315x160 mm dia |
| 6 | 315x315x140 mm dia |
| 7 | 315x315x110 mm dia |
| 8 | 315x315x90 mm dia |
| 9 | 250x250x200 mm dia |
| 10 | 250x250x160 mm dia |
| 11 | 250x250x140 mm dia |
| 12 | 250x250x110 mm dia |
| 13 | 250x250x90 mm dia |
| 14 | 200x200x160 mm dia |
| 15 | 200x200x140 mm dia |
| 16 | 200x200x110 mm dia |
| 17 | 200x200x90 mm dia |
| 18 | 160x160x140 mm dia |
| 19 | 160x160x110 mm dia |
| 20 | 160x160x90 mm dia |
| 21 | 140x140x110 mm dia |
| 22 | 140x140x90 mm dia |
| 23 | 110x110x90 mm dia |
| 24 | Providing and fitting fixing of different dia rigid UPVC equal Tee (including earth cutting & backfilling all socketted) suitable for pipes as per IS specification of Working pressure 4.0 kg/sq.cm confirming to IS: 10124 (Part-V) as per CPWD Specification & direction of Engineer-in-charge.Equal Tee315x315x315 mm dia |
| 25 | 250x250x250 mm dia |
| 26 | 200x200x200 mm dia |
| 27 | 160x160x160 mm dia |
| 28 | 140x140x140 mm dia |
| 29 | 110x110x110 mm dia |
| 30 | 90x90x90 mm dia |
| 31 | Providing and fitting fixing rigid UPVC Reducing socket (one size lower at one end, both end socketted) suitable for pipes of Working pressure 4.0 kg/sq.cm. as per CPWD Specification & direction ofEngineer-in-charge.315x250 mm dia |
| 32 | 250x200 mm dia |
| 33 | 200x160 mm dia |
| 34 | 160x140 mm dia |
| 35 | 140x110 mm dia |
| 36 | 110x90 mm dia |
| 37 | Providing & fitting fixing rigid UPVC bend(30 degree,45 degree,60 degree, 90 degree) for UPVC pipes as per IS specification of Working pressure 4.0 kg/sq.cm as per CPWD Specification & direction of Engineer-in-charge.160 mm dia |
| 38 | 140 mm dia |
| 39 | 110 mm dia |
| 40 | 90 mm dia |
| 41 | Dismentalling of existing PVC pipe from underground including necessary earth cutting etc.and dismentalled pipes, couplers, tees, etc properly stacking in safe site as per CPWD Specification & direction of Engineer-in-charge.a) Pipes,cables etcexceeding 75 mm dia but not exceeding 315 mm dia. |
| 42 | Labour charge for laying different dia rigid UPVC pipes of Working Pressure 4.0 kg/ sq.cm. complete with necessary coupler and solvent cement joints.( pipes, coupler and solvent cement will be issued free of cost) as per CPWD Specification & direction of Engineer-in-charge.160 mm dia |
| 43 | 200 mm dia |
| 44 | 250 mm dia |
| 45 | 315 mm dia |
| 46 | Providing and fitting fixing of G.I hydrant suitable for PVC pipes as per standard specification complete as per direction of Engineer-incharge (Rate excluding the cost of NTP control valve).80X50 mm dia |
| 47 | Providing & fitting fixing MS tail piece with MS flange suitable for pipes complete as per CPWD Specification & direction of Engineer-in-charge.80 mm dia PVC Pipe |
| 48 | 100 mm dia PVC Pipe |
| 49 | 125 mm dia PVC Pipe |
| 50 | 150 mm dia PVC Pipe |
| 51 | 200 mm dia PVC Pipe |
| 52 | 250 mm dia PVC Pipe |
| 53 | 300 mm dia PVC Pipe |
| 54 | Providing and laying different dia rigid UPVC pipes of Working Pressure 4.0 kg/ sq.cm. complete with necessary coupler and solvent cement as per CPWD Specification & direction of Engineer-in-charge.90 mm dia |
| 55 | 110 mm dia |
| 56 | 140 mm dia |
| 57 | 160 mm dia |
| 58 | 200 mm dia |
| 59 | 250 mm dia |
| 60 | Providing and fitting fixing of M.S shore manifold made with 3mm thick MS sheet of size one way 315 mm dia & three way 125 mm dia made with suitable flange(all end) including coating with steel primer(tailpiece if required will be paid separately) including proper alignment with pipe line & earth cutting, backfilling complete as per direction of Engineer-in-charge. |
| 61 | Labour charge for repairing of leakage in existing UPVC distribution system including required earth cutting and fitting fixing of necessary coupler etc. complete and refilling the trench with available excavated earth as per direction of the Engineer-in-charge. (Payment of couplers, tees, reducers etc will be made separately)315 mm dia |
| 62 | 250 mm dia to 110 mm dia. |
| 63 | 90 mm dia. |
| 64 | Dismentaling of G.I pipe including necessary earth cutting etc. & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge.125/150 mm dia |
| 65 | Dismentaling of G.I bend including necessary earth cutting etc. & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge.125/150 mm dia |
| 66 | Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge.A. External work.x. 125 mm dia. nominal bore |
| 67 | xi. 150 mm dia. nominal bore |
| 68 | Providing & fitting fixing of MS flange ( 8 mm wall thickness) by welding with G.I. / MS pipe and placing position as per specification and the direction of the Engineer-in-charge.i. 150 mm dia |
| 69 | ii. 125 mm dia |
| 70 | Providing & fitting fixing Rubber flange washer 6 mm thick at site of work of approved quality.i. 150 mm dia |
| 71 | ii. 125 mm dia |
| 72 | Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.iv. 100 mm dia.A. PN - 1.6 |
| 73 | v. 125 mm dia.A. PN - 1.6 |
| 74 | vi. 150 mm dia.A. PN - 1.6 |
| 75 | Providing and fixing MS bolts including nuts and washers complete as per standard design:- Above 300mm length. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender