Tender For Provn Of Qty -03 Precesion Air Conditioner Of 10 Ton Capacity At Dipac Under Ge (U) P&M Delhi Cantt-10.
Tender Value
68.31 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
12 days left
EMD
1.27 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Qty -03 Precesion Air Conditioner Of 10 Ton Capacity At Dipac Under Ge (U) P&M Delhi Cantt-10.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation & commissioning and testing including lifting & shifting floor Mounted, Bottom/Frontal discharge, Air Cooled DX type CRAC units for server room application, equiped with most advanced technology, guaranteeing precise control of Data Centres and server room. The units shall be selected on the basis of following parameters:i) 33 kW of minimum nominal Cooling Capacity @ 10000 CMHii) 28 Deg C / 36% RH of return airiii) Supply air in between 15 - 18 Deg Civ) 45 Deg C of Design Ambient temperaturev) Specific Power consumption shall be low as per site design conditions including compressor, evaporator fans and condensers.The Indoor unit shall comprise of Digital Scroll Compressor, Fibreglass corrossion resistant EC fans, Evaporator DX Cooling Coil with hydrophilic coating, Microprocessor controllers, TXV, Driers, G4 Filter, Suction and Discharge piping, Internal power and Control wiring, Crankcase heaters, Infrared Humidifier, Heaters, HP/LP Cutouts, Power and Control contactors, water leak detectors and Other Electrical accessories. The Outdoor Condenser unit shall comprise of Condenser fans & motor, Condenser cooling coil (Copper coil with aluminium fins), Fan speed controller, Isolater switch.vi) The system should be engineered for continuous 24/7/365 operation with high energy efficiency and tight tolerance limit. |
| 2 | vii) Control accuracy: Temp control within +1⁰C and relative humidity control within +5% RH.NOTES:- The unit shall be suitable for operation on 415 Volts, 50 Hz, 3 Phase, 4 Wire AC supply. Each unit should be having individual display panel, which shall display date, time, actual & set values, operating conditions, signal faults, collective faults, limiting values and PAC wellness alarm / service alarm to reduce the down time and unit memory shall hold the 400 most recent events with ID number, time and date stamp for each event The dimensions of the unit shall not be more than 900 mm x 900mm x 1970mm (L x D x H). Team Mode feature for PAC units controller for synchronising the Multiple No. of units to work as single system for all above units.Load sharing mode featureCascading EffectSequencing of above Units |
| 3 | Supply and fixing of Indoor Unit stand duly painted with anti-corrosive paint along with vibration pads, fittings and accessories complete all as specified and as directed |
| 4 | Suppy and fixing Outdoor Unit Stand - Choki type duly painted with anti-corrosive paint along with vibration pads, fittings and accessories complete all as specified and as directed |
| 5 | Material and Labour for Initial charge of R-410a refrigerant gas & oil complete all as specified and as directed |
| 6 | Supply and fixing of Interconnecting Copper piping for hot gas line between indoor & outdoor unit with all fittings and accessories.@20 RMT per machine complete all as specified and as directed |
| 7 | -Ditto- all as per Ser Item No 5 here-in-before but for liquid line |
| 8 | Supply & fixing of Interconnecting copper cabling of size 3Core x 2.5 sqmm between indoor & outdoor unit along with cable tray complete all as specified and as directed |
| 9 | Supply & fixing of Incoming copper cabling of size 4C x 10 sqmm from Incoming isolator to CRAC Unit (@5RM/Unit) complete all as specified and directed. |
| 10 | Supply & Fixing of condensate drain piping with CPVC pipes (@5RM/Unit) complete all as specified and directed. |
| 11 | Supply & Fixing of humidifier water piping with CPVC pipes (@5RM/Unit) complete all as specified and directed. |
| 12 | Extention piping kit complete all as specified and directed. |
| 13 | Material and labour for misc civil work including foundation for outdoor unit (03 Nos), cutting of tiles and adjustment as per ground requirement complete all as per specified and as directed |
| 14 | S&F ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 100 Amps complete all as specified and directed. |
| 15 | M&L for 1100 Volts grade heavy duty XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and over all PVC sheathed 35 Sqmm 3.5 core nominal cross section stranded conductor complete all as specified and directed. |
| 16 | S&F GI cable tray of size 150 mm x 50mm of thickness 1.6 mm on wall/roof for laying XLPE cable including nuts and bolts with washer complete all as specified and directed. |
| 17 | S&F return air motorized damper as per OEM standard complete all as specified and directed. |
| 18 | Supply, Installation, Testing and Commissioning of BIPOD Maintenance Free Chemical Earthing Based on 3000mm long Copper Bonded Earthing Electrode 200 Microns (Met-Chem) 50mm Outer Dia duly filled with ITPC-EECP15 fixed with Copper Strip 20 x 3mm riveted or fixed with SS nut bolts incl excavation/Earth work in any strata, returning filling, disposal of surplus soil, earth pit size 2.4m x 2.4m x 3.6m deep in PCC 1:3:6 type C-1 using 20mm graded stone aggregate, funnel, with CI Frame and cover (Earth Pit not less than 3.00M deep below ground level). The Electrode is surrounded by Chemical (ITPC-EECP15) a mixture of Sulphate, Silica, Iron Oxide, Nickel Oxide, Magnesium Oxide, Sodium Oxide, Zinc Oxide, Copper Sulphate etc (Earth Enhanced Compound Powder) & Crystallized Copper Material (CCM). Earth can have resistance <1 Ohm by using earth electrode is used as per the site requirements. Chemical Compound Powder to be provided minimum 100Kg per per earthing including taking down old unserviceable one complete all as specified and directed.(Make: ITPC / Model: Met Chem CBEE50 / EECP-15 / KE / Inpocon/ JMU Earthing/ Tirupathi/ Ashlok) Please Enable Macros to View BoQ information |
| 19 | Supply, Installation, Testing and Commissioning of BIPOD Maintenance Free Chemical Earthing Based on 3000mm long Copper Bonded Earthing Electrode 200 Microns (Met-Chem) 50mm Outer Dia duly filled with ITPC-EECP15 fixed with Copper Strip 20 x 3mm riveted or fixed with SS nut bolts incl excavation/Earth work in any strata, returning filling, disposal of surplus soil, earth pit size 2.4m x 2.4m x 3.6m deep in PCC 1:3:6 type C-1 using 20mm graded stone aggregate, funnel, with CI Frame and cover (Earth Pit not less than 3.00M deep below ground level). The Electrode is surrounded by Chemical (ITPC-EECP15) a mixture of Sulphate, Silica, Iron Oxide, Nickel Oxide, Magnesium Oxide, Sodium Oxide, Zinc Oxide, Copper Sulphate etc (Earth Enhanced Compound Powder) & Crystallized Copper Material (CCM). Earth can have resistance <1 Ohm by using earth electrode is used as per the site requirements. Chemical Compound Powder to be provided minimum 100Kg per per earthing including taking down old unserviceable one complete all as specified and directed.(Make: ITPC / Model: Met Chem CBEE50 / EECP-15 / KE / Inpocon/ JMU Earthing/ Tirupathi/ Ashlok) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysDec 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender