Housing Urban and Rular Development Government Departments Closing in 6 days TDR #58270137

Tender For General-Servicing And Repairs Of Ug Pump Room Machines-Govt Medical College, Palakkad-General Electrical Work

Issued by Government Departments · Palakkad, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
06 Nov 2026
6 days left
EMD
10571
Bank guarantee accepted
Document Fee
935
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Palakkad → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for General-Servicing And Repairs Of Ug Pump Room Machines-Govt Medical College, Palakkad-General Electrical Work

BOQ

Name of Work:- GENERAL-Servicing and repairs of UG pump room machines-Govt Medical College, Palakkad-General Electrical Work
Sl. No. Item Description
1service and repairs
2OD168601/2026-2027:General servicing & maintenance of induction motor motor driven centrifugal pump 100 HP for fire fighting including lifting the 100 HP motor after disconnecting the wire connection, decoupling the pump, detaching from the base plate, starters, TP switches etc. using chain block, rope, chain etc. and placing them conveniently on the platform. dismantling of pump, motor and starter as required; cleaning and removal of silt, mud, foreign bodies and water deposits due to flooding; drying and cleaning of motor and electrical components; insulation resistance testing by megger, checking winding condition, terminals and cable connections; cleaning, greasing and lubrication; changing of oil wherever required; checking and correction of pump-motor alignment; inspection and servicing of bearings; renewal of gland packing, gasket and rubber packing wherever required; checking pump shaft, sleeves, impeller, casing and coupling; replacement of damaged coupling rubber bush and coupling bolts; overhauling, cleaning and reconditioning of starter including contactors, overload relay, terminals, internal wiring etc.; reconditioning of damaged parts; refitting, testing and commissioning under full-load operating conditions; painting of pump, motor and associated components with suitable primer and two coats of approved enamel paint; including all labour, tools, tackles, consumables, transportation within site Reerecting the 100 hp motor in pump room Refitting motor, starter and other electrical accessories,( Accessories when necessary ) and erecting the motor on the base plate coupling with pump in position giving connections checking correct alignment and trial run on full load and all incidental works complete as directed by the Engineer-in-Charge
3OD168602/2026-2027:General servicing & maintenance of induction motor motor driven centrifugal pump 7.5 for fire fighting including lifting the 7.5 HP motor after disconnecting the wire connection, decoupling the pump, detaching from the base plate, starters, TP switches etc. using chain block, rope, chain etc. and placing them conveniently on the platform. dismantling of pump, motor and starter as required; cleaning and removal of silt, mud, foreign bodies and water deposits due to flooding; drying and cleaning of motor and electrical components; insulation resistance testing by megger, checking winding condition, terminals and cable connections; cleaning, greasing and lubrication; changing of oil wherever required; checking and correction of pump-motor alignment; inspection and servicing of bearings; renewal of gland packing, gasket and rubber packing wherever required; checking pump shaft, sleeves, impeller, casing and coupling; replacement of damaged coupling rubber bush and coupling bolts; overhauling, cleaning and reconditioning of starter including contactors, overload relay, terminals, internal wiring etc.; reconditioning of damaged parts; refitting, testing and commissioning under full-load operating conditions; painting of pump, motor and associated components with suitable primer and two coats of approved enamel paint; including all labour, tools, tackles, consumables, transportation within site Reerecting the 7.5 hp motor in pump room Refitting motor, starter and other electrical accessories,( Accessories when necessary ) and erecting the motor on the base plate coupling with pump in position giving connections checking correct alignment and trial run on full load and all incidental works complete as directed by the Engineer-in-Charge
4OD151723/2026-2027: General servicing, maintenance, checking, overhauling and testing of existing 50 HP diesel engine for fire-fighting pump, including removal of mud, silt, water deposits and foreign bodies due to flooding; cleaning of engine and associated components; checking and replacement of engine lubricating oil, oil filter, fuel filter and air filter wherever required; checking fuel system, fuel lines, fuel pump, injectors, cooling system, radiator, water pump, belts, hoses, battery and battery connections; draining and refilling contaminated oil; checking starting system, electrical connections and charging system; checking engine mounting and alignment with pump; checking coupling and coupling bolts; cleaning, greasing and lubrication of all applicable moving parts; checking engine controls, gauges and safety devices; testing of insulation of associated electrical wiring wherever applicable; checking for abnormal noise, vibration, leakage and overheating; attending minor repairs and adjustments; refilling of oil/coolant and other necessary consumables; starting, trial running and performance testing of the engine under operating conditions, including all labour, tools, tackles, consumables and incidental works complete as directed by the Engineer-in-Charge
5OD136616/2026-2027:Supply of engine oil
6OD137796/2026-2027:Supply of Diesel Engine Oil Filter
7OD136642/2026-2027:Supply of engine coolant
8OD136725/2026-2027:Supply of diesel for testing.
9OD136869/2026-2027:Supply of Exide make 12V, 180Ah heavy-duty automotive battery suitable for diesel engine starting,
10OD137787/2026-2027:Supply of 10A12V Battery charger
11OD136876/2026-2027:General servicing, checking and maintenance of existing fire-fighting pump electrical control panel comprising 630 A, 4-pole incomer isolator, multifunction meter, LED indicating lamps, 2 Nos. 250 A FP SDUs for main fire-fighting pumps, 2 Nos. 63 A FP SDUs for jockey pumps and 1 No. 32 A FP SDU for diesel pump battery charging, including isolation and dismantling of panel components as required, removal of mud, silt, water deposits and foreign bodies due to flooding, cleaning and drying of all electrical components, checking insulation resistance and continuity, checking and tightening of all busbar, cable and control connections, checking operation and condition of isolator, SDUs, meters, indicating lamps and control wiring, rewiring of main control panel including necessary control cables, ferrules, lugs, sleeves and other accessories, replacement of damaged minor wiring and terminals, cleaning and reconditioning of components, testing and commissioning of the complete panel after servicing, including all labour, tools, tackles, consumables and incidental works complete as directed by the Engineer-in-Charge.
12OD137158/2026-2027:Rewiring of Diesel Engine Control system including necessary cables, connectors etc
13OD136905/2026-2027:Supply & repalcing of MNX 135 contactor suitable for Main pump
14OD137765/2026-2027:Supply & repalcing of MNX 110 contactor suitable for Main pump
15OD136910/2026-2027:Supply & repalcing of MNX 32 contactor suitable for jockey pump
16OD137846/2026-2027:Supply and replacement of minor spares
17OD178359/2026-2027:Charges for disconnecting 3.5C 95 sq.mm XLPE incomer cable from the existing panel on both sides attending pettty repairs and transporting the cable to nearest electrical room for safe keeping.
1890.12.7.31:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58270137
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 06-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for General-Servicing And Repairs Of Ug Pump Room Machines-Govt Medical College, Palakkad-General Electrical Work
Basic Detail
Tender No ET-29/ESDPKD/2026-2027
Bidding Type Tender
Location
City Palakkad
State Kerala
Key Dates
Publish Date 29 Oct 2026
Submission Date 06 Nov 2026
Open Date 09 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee 935
EMD 10571
Exemption Not Available
Document List
88e802a7-aa8c-4e3c-80ea-c3a43be24dbd.html
BOQ.xls
NIT.pdf
SBD.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

88e802a7-aa8c-4e3c-80ea-c3a43be24dbd.html

xls

BOQ.xls

pdf

NIT.pdf

pdf

SBD.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender