Housing Urban and Rular Development Government Departments Closing in 6 days TDR #58269506

Tender For Supply, Installation, Testing And Commissioning Of Water Fountains At Dabri-Palam Island Under Pwd Emd South West, New Delhi. (Sub Head : Civil & Electrical Works).

Issued by Government Departments · New Delhi, Delhi
Tender Value
54.93 Lakhs
Estimated cost
Bid Submission
05 Nov 2026
6 days left
EMD
1.09 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply, Installation, Testing And Commissioning Of Water Fountains At Dabri-Palam Island Under Pwd Emd South West, New Delhi. (Sub Head : Civil & Electrical Works).

BOQ

Name of Work:- Supply, installation, testing and commissioning of Water Fountains at Dabri-Palam Island under PWD EMD South West, New Delhi. (Sub Head : Civil & Electrical works).
Sl. No. Item Description
1SITC of Foam jet High contrast for producing high contrast/foam effect to extensively wind stable, water level independent moc Brass /SS 316L of following size.
225 mm Dia inlet 32 mm orfice 160 mm long.
3Supply Installation Testing and Commissioning of 100 mm Dia Debris Collection Strainer in Stainless steel 304 gr Complete as reqd. All fixing to be done as per direction instruction and entire satisfaction of Engineer-in-charge.
4Supply Installation Testing and Commissioning of three phase openwell ISI Marked submersible pumpset of 1.5H.P. capacity suitable for operation on 415V(+-10%), 3- phase AC supply compaitable for operations on dynamic variable frequency / speed having IP 68 Protection including providing required no's of heavy duty M.S clamps made of flat iron and suitable size top cover made of suitable thick MS sheet as required.and making of flexible IP68 cable connections etc. complete of suitable head and discharge as aproved by engineeer incharge as reqd.
5Supply Installation Testing and Commissioning of three phase openwell ISI Marked submersible pumpset of 7.5 H.P. capacity suitable for operation on 415V(+-10%), 3- phase AC supply compaitable for operations on dynamic variable frequency / speed having IP 68 Protection including providing required no's of heavy duty M.S clamps made of flat iron and suitable size top cover made of suitable thick MS sheet as required. and making of flexible IP68 cable connections etc complete as reqd.
6Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
725 mm dia
8Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
963 mm dia (OD-63 mm & ID-51 mm nominal)
10Supplying, fixing, Testing and Commissioning of Butterly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with Nuts, bolts, washer, gaskets confirming to IS 13095 of following sizes as required.
11100mm dia.
12Supply Installation Testing and Commissioning of fixing of following dia. Gun metal Horizontal Non Return valve ( screwed type ) on the existing pipeline, including testing & Commissioning etc. As required.
13100 mm dia
1450 mm dia.
15Supply Installation Testing and Commissioning of fixing of following dia. Gun metal gate valve ( Screwed type ) on the existing pipeline, including testing & Commissioning etc. as required.
1650 mm dia.
17Supplying, Installation, Testing and Commissioning of underwater Luminaries surface mounted RGB LED spot light 6 x 3W with IP 68 protection, SS/ aluminium dia casting body with power coated paint, soft rubber gasket along with 2 years free replacement guaranty etc. as required.
18Supplying, Installation, Testing and Commissioning of RGB controller with remote Kit wattage not less than 200 watt i/c connection along with 2 years free replacement guaranty etc. as required.
19Supplying, Installation, Testing and Commissioning of Signal Amplifier of RGB signal as require i/c connection along with 2 years free replacement guaranty etc. as required.
20Supply of Installation Testing and Commissioning of fixing of Power Supply/SMPS for suitable to run LED Lights, Body-Metal input Power-220 V AC/ Output Power-12 V DC, complete as per the Direction & Entire Satisfaction of engineer in charge
21Supplying & fixing PVC insulated PVC sheathed copper conductor submersible flat cable ISI Marked in existing metal/HDPE / PVC/ pipe/ in bore well/ in sump including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes etc. as required.
223 Core 2.5 Sq mm Flat Cable
233 Core 6 Sq mm Flat Cable
24Supply, Installation, Testing and Commissioning adjustable 1 Way stainless steel stand (SS-304) for LED lights 6X3 Watt with all accessories including nuts bolts complete.
25Supplying and Laying of pvc insulated & FRLS multi core round Sheathed Bright Annealed Bare Copper Conductor Heavy Duty Industrial Cables for Voltage Grade upto 1100 Volts as per IS: 694:2010 complete as required.
264 core x 2.50 sq mm size
27Supply, Installation, Testing and Commissioning Making water Proof joint of underwater cables for submersible cable complete as required.
28Supply, Installation, Testing and Commissioning of UPVC pipes of confirming to IS 4985:2000 including all UPVC fitting i/c jointing with good quality solvent of following sizes complete as required.
29110 mm OD Pipe for Delivery Lines
3090 mm OD Pipe for Delivery Lines
3150 mm OD Pipe for Delivery Lines
3240 mm OD Pipe for Delivery Lines
33Supply, Installation, Testing and Commissioning of Fordged Brass Ball Valve complete as required.
3425 mm Dia.
3540 mm Dia.
36Supply, Installation, Testing and Commissioning of out door type control panel suitable for fountain equipment including wiring, cabling, cable tray control wiring etc. The control panel shall be compartalized for individual outgoing and shall be made out of 16 SWG CRC sheet in grey color and shall be floor mounted with following, Size 600(L)x600(B)x300(H). (for 7.5 HP Pump - 1 no.) (for 1.5 HP Drain Pump - 1 no.)
37(a) 4 Pole MCCB 125A 1.00 no.
38(b) 3 Pole MCB 32Amps 4.00 nos.
39(c) DOL Pump Starter 7.5HP / 3 Phase 3.00 nos.
40(d) DOL Pump Starter 1.5HP / 3 Phase 1.00 no.
41(e) DP MCB 20 Amp. 4.00 nos.
42(f) Volt selector switch 1.00 no.
43(g) Voltmeter 0-500 v 1.00 no.
44(h) Digital Time Switch - 2.00 nos.
45(i) Indicators - 1.00 Set
46(j) MS Panel Stand - 1 no.
47Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
48Running, Operation & Maintenance i/c Watch and Ward of Following Water Features 24 hours by deploying skilled operator consisting of repairing of electrical and mechanical faults of pump sets, nozzles, underwater lights, light contollers, electrical control panels, electrical cables, plumbing pipes ,checking of electirical connection, adjustment of nozzles effect heights for the somooth functioning of the existing fountains i/c cleaning the tank etc. complete as required and as per direction of Engineer-In-Charge.One no. in each shift - Round the Clock (6:00AM to 2:00PM, 2PM to 10PM & 10PM to 6:AM)
49Palam Dabri -Foam jet Water Feature:- 03 Operators (each in shift)
50Supplying of Water through Water Tanker Truck of minimum water carrying 5000 ltrs. for the use of filling water in 02 Nos. of fountains at above locations in the item no. 1. The Water Tanker Truck must be provided with the Driver, Helper, Fuel & Water (quality fit for filling fountains water bodies) etc. all charges included. The timing, locations, trips and any other directions as per the entire satisfaction of the Engineer-in-Charge.
51Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.
52All kinds of soil
53Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
541:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
551:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
56Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
57Cement mortar 1:6 (1 cement : 6 coarse sand)
58Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade.
59Red sand stone
60Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
61Granite stone slab of colour black, Cherry/Ruby red
62Area of slab upto 0.50 sqm
6340mm thick fine sand dressed stone in riser of stairs,dedo and pillars wall, laid over 12 mm (average) thick base of cement mortar (1:3) with joint,height is upto 1.00 mtr.
64Fine dressed red sand stone with 40 mm thick.
65Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
66In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
67Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
68Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
69Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
70In cement mortar
71Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
72Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
73Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
7425 mm nominal outer dia .Pipes.
75Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customized design as per direction of Engineer in charge. The glass mosaic tiles shall be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operations, material and required pattern approved by Engineer-in-charge.
76Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
77Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineerin-Charge
78With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
79Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
80Add modified GST correction @ 0.973 on all DSR items
81Add Cost Index 4.03%
82Providing, supplying & installing the hand crafted sand stone fountain using traditional technique and modern tools having the dia of plate = 6 feet, dia of base = 26\\" at bottom and 12\\" at top with 4 feet height. The outer dia of nozzle = 12\\" at bottom & 6\\" at top with height = 6 feet. The complete design & art work as approved by Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58269506
AUTHORITY Government Departments
TENDER VALUE 54.93 Lakhs
LAST DATE 05-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Supply, Installation, Testing And Commissioning Of Water Fountains At Dabri-Palam Island Under Pwd Emd South West, New Delhi. (Sub Head : Civil & Electrical Works).
Basic Detail
Tender No 80/EE (E)/PWD EMD South West/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 29 Oct 2026
Submission Date 05 Nov 2026
Open Date 05 Nov 2026
Finance
Tender Value 54.93 Lakhs
Tender Fee Ref. Documents
EMD 1.09 Lakhs
Exemption Not Available
Document List
628b6d93-fb8d-424b-9880-0458b943962f.html
BOQ_401314.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

628b6d93-fb8d-424b-9880-0458b943962f.html

xls

BOQ_401314.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender