Tender for Wiring Work For Installation Of Concrete 3D Printer And Disc Pelletizer To Be Procured Through Dst Shri Project
BOQ
| Sl. No. | Item Description |
| 1 | WIRING |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 3 | Group C |
| 4 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 5 | 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 6 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 7 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 8 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 9 | 3 x 1.5 sq. mm |
| 10 | 3 x 2.5 sq. mm |
| 11 | 6 x 2.5 sq. mm |
| 12 | 2 x 6 sq. mm |
| 13 | 4 x 6 sq. mm |
| 14 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 15 | 20 mm |
| 16 | 25 mm |
| 17 | 32 mm |
| 18 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 19 | 5/6 A switch |
| 20 | 15/16 A switch |
| 21 | 3 pin 5/6 A socket outlet |
| 22 | Supplying and fixing of 15/16A modular socket, Three module including connection, etc., as required. on existing modular cover plate. Make:Legrand Myrius Equivalent |
| 23 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 24 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 25 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 26 | 1 or 2 Module (75mmX75mm) |
| 27 | 3 Module (100mmX75mm) |
| 28 | 4 Module (125mmX75mm) |
| 29 | 6 Module (200mmX75mm) |
| 30 | 8 Module (125mmX125mm) |
| 31 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) including making of cable incomer/outgoing with permanent paint as per KEI Standard.Submission of electrical schematic drawing in CAD file & Hard copywith load addittion details with class B contractor sign as required for the KEI standard for energization and load addittion requirement. |
| 32 | 8 way , Double door |
| 33 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 34 | Single pole |
| 35 | Double pole |
| 36 | Triple pole |
| 37 | Triple pole and neutral |
| 38 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 39 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 40 | Supplying and fixing 3 phase 8 way (8+24) double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB) including making of cable incomer/outgoing with permanent paint as per KEI Standard.Submission of electrical schematic drawing in CAD file & Hard copywith load addittion details with class B contractor sign as required for the KEI standard for energization and load addittion requirement. |
| 41 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 42 | Supplying and fixing 32 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 32 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 43 | Supplying and fixing DP/TP/FP Enclosure complete with connections, testing and commissioning etc. as required. |
| 44 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. (but without charcoal/ coke and salt ) as required. |
| 45 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt(10mm dia), spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 46 | Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 °C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. (Atomberg efficio or equivalent). |
| 47 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 235 CM/Min (Minimum) |
| 48 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 49 | Upto 35 sq. mm |
| 50 | Above 35 sq. mm and upto 95 sq. mm |
| 51 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 52 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 53 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 54 | 2 X 10 sq. mm (19mm) |
| 55 | 4 X 50 sq. mm (35mm) |
| 56 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 57 | 2x16 sq. mm/2x10 sq. mm |
| 58 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 59 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 60 | Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench 40mm or nearest size |
| 61 | Supplying and fixing 125A, 16kA, 4 pole (Three pole and Neutral), 415 V, Moulded casing circuit breaker (MCCB) with Thermal magnetic and Electronic earth leakage module, including spreader link in the existing MCCB Distribution Board , complete with connections, testing and commissioning etc, as required.Legrand or equivalent etc. |
| 62 | Supply and fixing of box type tube fittings (Batten ) compatible for fixing 2 T8 LED tube light, complete with side holders etc, as required.(Batten- CIS-341-40-65--SL-NWH 2XT8 or compatible) |
| 63 | Supply and fixing of 18/20 watt 4 feet T8 LED tube with efficacy 100lm/W. (T8 LED-Crompton LGT8-20-865-2 or compatible) |
| 64 | Supply of 2x10 Sq.mm PVC/ XLPE Aluminium Armoured Cable, 650/1100V. Grade confirming to IS:7098 (Pt-1)1988 |
| 65 | Supply and laying one number of the 12 SWG good quality bare copper wire along the cable with connections etc. as required. |
| 66 | Supply and laying one number of the 8 SWG good quality bare copper wire along the cable with connections etc. as required. |
| 67 | Supply of suitable amount (60kg) of earthing compound (EXCEL compound or equivalent) etc. as required. |
| 68 | Supply of 4X50 Sq.mm PVC/ XLPE Aluminium Armoured Cable, 650/1100V. Grade confirming to IS:7098 (Pt-1)198 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysNov 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender