Tender For Agro-Enterprise Model On Production Of Qpm Of Fruits, Vegetables And Flowers, At Kvk, Mayurbhanj-I, Samakhunta
Tender Value
10.51 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
8 days left
EMD
10514
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mayurbhanj → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Agro-Enterprise Model On Production Of Qpm Of Fruits, Vegetables And Flowers, At Kvk, Mayurbhanj-I, Samakhunta
BOQ
| Sl. No. | Item Description |
| 1 | LAND DEVELOPMENT |
| 2 | Foundation excavation in hard soil including levelling and dressing the bed and sides depositing muck within initial lead and lift etc. complete as per direction of Engg-in-Charge . |
| 3 | Fine dressing of earth work in hard soil including cutting or filling earth upto 0.15 m depth of surface. |
| 4 | CONSTRUCTION OF FIELD STORE |
| 5 | Earth work in hard soil or gravelly soil within 50m. initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge. |
| 6 | Supplying, filling in foundation and plinth with sand in 22.5 cm (9”) thick layers including watering and ramming with cost, conveyance, royalties and taxes of sand with labour and T&P required for the work etc. complete (Measurement will be taken on finished compacted section only). |
| 7 | Cement concrete of proportion (1:4:8) in foundation and floors using 4cm (1½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming,watering, curing etc. complete including cost, conveyance,royalties and excluding GST of all materials with all labour,cess and T&P required for the work etc. complete in all respect. |
| 8 | 1” thick D.P.C with C.C(1:2:4) using 12mm. Chips etc. cpmplete as per direction of Engg-in-Charge . |
| 9 | R.C.C. work M-20 grade using 20mm and 10mm size black hard crusher broken granite chips including hoisting lowering laying and centring shuttering and finishing the exposed surface smooth providing groves or beds wherever necessary including cost, conveyance, royalties and excluding GST and cost of all materials and labour with T & P required for the work etc. complete in all respect excluding the cost of M.S. Rods or Tor steel and binding wires and labour charge for bending binding and tying grills as directed by the Engineer – in charge in Ground Floor. |
| 10 | Ground floor |
| 11 | (a) Column base |
| 12 | (b) Plinth band |
| 13 | (c) Lintel |
| 14 | (d) Column and beam |
| 15 | (e) Sun shade and Chajja |
| 16 | (f) Roof Slab |
| 17 | Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification including cost, conveyance and excluding GST of all materials with labour, cess and T&P etc. required for the work complete. |
| 18 | Ground floor |
| 19 | Fly Ash brick masonry in cement mortar (1:6) in Plinth & Foundation work using fly ash bricks of 23cm x 11cm x 8cm size having a crushing strength of not less than 75 kg/cm2 with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing including cost, conveyance, royalties and excluding GST of all materials with all labour, cess and T&P required for the work complete in all respect in all floors. |
| 20 | Fly Ash brick masonry in cement mortar (1:6) in Super strucutre work using fly ash bricks of 23cm x 11cm x8cm size having a crushing strength of not less than 75kg/cm2 with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similarsuch type of works with all necessary projections watering and curing including cost, conveyance, royalties and excluding GST of all materials with all labour, cess and T&P required for thework complete in all respect in all floors. |
| 21 | Ground floor |
| 22 | 12 mm (5/8”) thick cement plaster (1:6) finished smooth to inside rough surface of 9”/10” thick brick walls after rakingout the joints including watering and curing with cost withcost, conveyance, royalties and excluding GST of all materialswith all labour, T&P required for the work etc. complete. |
| 23 | Ground floor |
| 24 | 16 mm (½”) thick cement plaster (1:6) finished smooth to outside smooth surface of brick walls after raking out the jointincluding watering and curing with cost, conveyance, royaltiesand excluding GST of all materials with all labour and T&Prequired for the work etc. complete in all respect. |
| 25 | Ground floor |
| 26 | 2.5 cm thick grading concrete [1:2:2 ] on roof slab with 6 mm size chips including rubbing and polishing etc. complete including watering and curing with cost, conveyance, royaltiesand excluding GST of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 27 | Ground floor |
| 28 | Fixing colour Vitrified tiles in floors (Printed Series) of size 600mm x600 mm of approved make conforming IS:13755 laid on 20 mm thick cement mortar (1:1)and filling joints with white cement of approved quality including cost of all materials, labour T&P etc rrequired for the work all completeas per direction of Engineer-in-charge. |
| 29 | Ground floor |
| 30 | Fixing Vitrified tiles in dados (Printed Series) skirting and risers of stepson 12 mm thick cement plaster(1:3) jointed with neat cement slurry mixed with pigments to matche shade of the tiles including rubbing and polishing complete as per direction of Engineer-in-charge. |
| 31 | Ground floor |
| 32 | Wall Priming one coats on new work with wall water bound primer of approved shade as per direction of Engg-in-Charge. |
| 33 | Ground floor |
| 34 | Finishing inside walls with Distemper of approved shade on new work two coats to give an even shade including watering and curing with cost, conveyance, royalties and excluding GST of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 35 | Ground floor |
| 36 | Painting two coats with weather seal coat paint over a coat of primer with water bound cement paint including cost, conveyance, excluding GST of all materials, labour and T&P etc. complete. |
| 37 | Ground floor |
| 38 | Supply fitting and fixing MS grill with Iron work wrought and put up in window grating including drilling holes in choukathas etc. complete as per direction of Engg-in-Charge . |
| 39 | Ground floor |
| 40 | Enamel Painting two coats with enamel paint over one coat of primer of approved quality etc. complete as per direction of Engg-in-Charge . |
| 41 | Ground floor |
| 42 | Recssed wiring to light point & Exhaust fan point with 1.5 sqmm FR PVC Insulated single core multistandard copper conductor of ISI marked with 20mm dia non metalic PVC flexible conduit with 5A ,250V modular type switch of ISI marked & ceiling rose of ISI marked mounted on MS BOX having front back light cover of suitable size, MS box with 1.5 sqmm FR PVC insulated single core multistrand copper conductor and earth wire including all accessories and connection as per direction of Engineer in charge(make of wire=Finollex/L& T/Anchor/Havels/V-guard/Great white)(deducting the cost of S/F of 100mmx100mmx60mm M.S Box with Backlite cover-1no) |
| 43 | Group-A(1.1.1.1-1.24.2) |
| 44 | Ressed wiring to Fan point in Group-B |
| 45 | Supply Installation testing and commissioning of 32A DP Main Switchs(IS 13940 part 3/1993) of following capacity on existing surface/wall mounting & complete with H.R.C fuse links inter connections earthig etc as required as per direction of Engineer Incharge (Make-seimens/HPL/Anchor/L & T Havels/C & S/R.K) |
| 46 | Wiring for circuit/sub main wiring alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked confirming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduct 1.6mm in recessed PVC conduit as required (Make of wire-Finolex/L & T /Anchor/Havels/V-guard) |
| 47 | do- 2x4sqmm +1x1.5sqmm(1.8.2) |
| 48 | do- 2x1.5sqmm +1x1.5sqmm(1.8.2) |
| 49 | S/F of 'B' series SP MCB of 6amp rating 240volt B series MCB for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection testing and commissioning etc as required single pole(SP)(2.6.1) |
| 50 | S/F of batten holder BK angle holder ISI marked including connection etc instead of celling rose(1.29-1.28) |
| 51 | Sinking of Borewell |
| 52 | Labour for drilling a perfectly vertical bore holes in boulder formation areas with down the hole hammer drilling rigs or combination drilling rigs to suit the site condition with deployment of rigs, necessary accessories and consumables for a specified depth below ground level including sopply of necessary cashing shoe, odex tools and plants, jointing materials, extra sockets where required withdrawing of pipes, lowering the M S ( E R W ) pipes and fitting and fixing in perfectly vertical position including cutting and welding for jointing the pipes for simultaneous casing lowering in over burden nboulder formation till encounter of hard rock and to drill 125mm DTH upto the desired depth as may be necessary, clearing the site and washing bore etc; all complete providing sanitary sealing upto 5 mtrs depth below ground level as the direction of Engineer in charge. |
| 53 | 0 mtr to 40mtr |
| 54 | 40 mtr to 100 mtr |
| 55 | Supplying all labour T & P, for Cleaning and developing the Production well with their own comprssor continously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipments and labours as per the direction of Engineer-in-charge. |
| 56 | Supply of 125 mm nominal diameter MS ERW Casing pipe. |
| 57 | Cost of 125 mm dia M S Casing Shoes forged used in the bottom of casing Pipe. |
| 58 | 32 MM PVC Column pipe |
| 59 | 32 MM G. I clamp |
| 60 | Copper wire & thread seal |
| 61 | 3 core cupper submerssible cable (2.5) |
| 62 | Accessories for pump fitting |
| 63 | Service cable |
| 64 | Transportation charge |
| 65 | 32 mm adapter & socket |
| 66 | 33 mm bend and nipple |
| 67 | Delivery pipe 1/14 |
| 68 | Accessories for delivery pipe fitting |
| 69 | Nylon rope |
| 70 | Supply and fitting of 1.5Hp submersible motor and pump set (KSB/Kirloskar/Crompton/CRI and other makes of repute) |
| 71 | 1.5 HP, submersible control pannel Board |
| 72 | Bore Cap 5''-6” CI make s per requirement |
| 73 | Installation of pump set |
| 74 | 25mm dia UPVC pipe |
| 75 | 25mm UPVCunion |
| 76 | 25mm diaUPVC ASTM BALLVALVE |
| 77 | 25mm dia UPVC ASTM Tank Nipple |
| 78 | 25mm dia upvc male threaded adaptor |
| 79 | Foundation excavation in hard soil including levelling and dressing the bed and sides depositing muck within initial lead and lift etc. complete as per the direction of the Engineer-in-charge. |
| 80 | Filling sand in foundation and plinth including watering and ramming etc. complete as per the direction of the Engineer-in-charge. |
| 81 | Cement concrete 1:3:6 using 4cm. size HBG crusher broken metal including cost,conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge . |
| 82 | Cement Concrete (1:2:4) with 12 mm size broken hard granite chips for R.C.C. works including hoisting and laying etc. complete as per direction of Engg-in-Charge . |
| 83 | Brick work with Fly Ash Bricks having crushing strength 75 kg/sq.cm in c.m. 1:6 in F & P including cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge . |
| 84 | 12mm. thick cement plaster in c.m. 1:6 over brick masonry including cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge . |
| 85 | Cement washing two coats with cost of all labour & materials etc. complete as per direction of Engg-in-Charge . |
| 86 | CONSTRUCTION OF PUMP HOUSE |
| 87 | Earth work in hard soil or gravelly soil within 50m. initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge. |
| 88 | Supplying, filling in foundation and plinth with sand in 22.5 cm (9”) thick layers including watering and ramming with cost, conveyance, royalties and taxes of sand with labour and T&P required for the work etc. complete (Measurement will be taken on finished compacted section only). |
| 89 | Cement concrete of proportion (1:4:8) in foundation and floors using 4cm (1½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming,watering, curing etc. complete including cost, conveyance,royalties and excluding GST of all materials with all labour,cess and T&P required for the work etc. complete in all respect. |
| 90 | R.C.C. work M-20 grade using 20mm and 10mm size black hard crusher broken granite chips including hoisting lowering laying and centring shuttering and finishing the exposed surface smooth providing groves or beds wherever necessary including cost, conveyance, royalties and excluding GST and cost of all materials and labour with T & P required for the work etc. complete in all respect excluding the cost of M.S. Rods or Tor steel and binding wires and labour charge for bending binding and tying grills as directed by the Engineer – in charge in Ground Floor. |
| 91 | Ground floor |
| 92 | (a) Column base |
| 93 | (b) Plinth band |
| 94 | (c) Lintel |
| 95 | (d) Column and beam |
| 96 | (e) Sun shade and Chajja |
| 97 | (f) Roof Slab |
| 98 | Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification including cost, conveyance and excluding GST of all materials with labour, cess and T&P etc. required for the work complete. |
| 99 | Ground floor |
| 100 | Fly Ash brick masonry in cement mortar (1:6) in Plinth & Foundation work using fly ash bricks of 23cm x 11cm x 8cm size having a crushing strength of not less than 75 kg/cm2 with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing including cost, conveyance, royalties and excluding GST of all materials with all labour, cess and T&P required for the work complete in all respect in all floors. |
| 101 | Fly Ash brick masonry in cement mortar (1:6) in Super strucutre work using fly ash bricks of 23cm x 11cm x8cm size having a crushing strength of not less than 75kg/cm2 with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similarsuch type of works with all necessary projections watering and curing including cost, conveyance, royalties and excluding GST of all materials with all labour, cess and T&P required for thework complete in all respect in all floors. |
| 102 | Ground floor |
| 103 | 12 mm (5/8”) thick cement plaster (1:6) finished smooth to inside rough surface of 9”/10” thick brick walls after rakingout the joints including watering and curing with cost withcost, conveyance, royalties and excluding GST of all materialswith all labour, T&P required for the work etc. complete. |
| 104 | Ground floor |
| 105 | 16 mm (½”) thick cement plaster (1:6) finished smooth to outside smooth surface of brick walls after raking out the jointincluding watering and curing with cost, conveyance, royaltiesand excluding GST of all materials with all labour and T&Prequired for the work etc. complete in all respect. |
| 106 | Ground floor |
| 107 | 2.5 cm thick grading concrete [1:2:2 ] on roof slab with 6 mm size chips including rubbing and polishing etc. complete including watering and curing with cost, conveyance, royaltiesand excluding GST of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 108 | Ground floor |
| 109 | Supplying,fitting & fixing of stainless steel of 304 grade in Hand Railing using 50mm. Dia of 2mm. thick circular pipe with Balustrade of size 32mm.x32mm.x2mm. @ 0.90m. C/C and stainless square pipe bracing of size 32mm.x32mm.x2mm. In 3 rows in stair case as per approved design and specification,buffing,polishing etc. with cost, conveyance, taxes of all materials labour T & P etc. required for the completion in all respect etc. complete as per direction of Engg-in-Charge . |
| 110 | Ground floor |
| 111 | Wall Priming one coats on new work with wall water bound primer of approved shade as per direction of Engg-in-Charge. |
| 112 | Ground floor |
| 113 | Finishing inside walls with Distemper of approved shade on new work two coats to give an even shade including watering and curing with cost, conveyance, royalties and excluding GST of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 114 | Ground floor |
| 115 | Painting two coats with weather seal coat paint over a coat of primer with water bound cement paint including cost, conveyance, excluding GST of all materials, labour and T&P etc. complete. |
| 116 | Ground floor |
| 117 | Supply fitting and fixing MS grill with Iron work wrought and put up in window grating including drilling holes in choukathas etc. complete as per direction of Engg-in-Charge . |
| 118 | Ground floor |
| 119 | Enamel Painting two coats with enamel paint over one coat of primer of approved quality etc. complete as per direction of Engg-in-Charge . |
| 120 | Ground floor |
| 121 | Recssed wiring to light point & Exhaust fan point with 1.5 sqmm FR PVC Insulated single core multistandard copper conductor of ISI marked with 20mm dia non metalic PVC flexible conduit with 5A ,250V modular type switch of ISI marked & ceiling rose of ISI marked mounted on MS BOX having front back light cover of suitable size, MS box with 1.5 sqmm FR PVC insulated single core multistrand copper conductor and earth wire including all accessories and connection as per direction of Engineer in charge(make of wire=Finollex/L& T/Anchor/Havels/V-guard/Great white)(deducting the cost of S/F of 100mmx100mmx60mm M.S Box with Backlite cover-1no) |
| 122 | Group-A(1.1.1.1-1.24.2) |
| 123 | Ressed wiring to Fan point in Group-B |
| 124 | Supply Installation testing and commissioning of 32A DP Main Switchs(IS 13940 part 3/1993) of following capacity on existing surface/wall mounting & complete with H.R.C fuse links inter connections earthig etc as required as per direction of Engineer Incharge (Make-seimens/HPL/Anchor/L & T Havels/C & S/R.K) |
| 125 | Wiring for circuit/sub main wiring alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked confirming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduct 1.6mm in recessed PVC conduit as required (Make of wire-Finolex/L & T /Anchor/Havels/V-guard) |
| 126 | do- 2x4sqmm +1x1.5sqmm(1.8.2) |
| 127 | do- 2x2.5sqmm +1x1.5sqmm(1.8.2) |
| 128 | S/F of 'B' series SP MCB of 6amp rating 240volt B series MCB for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection testing and commissioning etc as required single pole(SP)(2.6.1) |
| 129 | S/F of batten holder BK angle holder ISI marked including connection etc instead of celling rose(1.29-1.28) |
| 130 | CONSTRUCTION OF OFFICE CUM STORE |
| 131 | Earth work in hard soil or gravelly soil within 50m. initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge. |
| 132 | Supplying, filling in foundation and plinth with sand in 22.5 cm (9”) thick layers including watering and ramming with cost, conveyance, royalties and taxes of sand with labour and T&P required for the work etc. complete (Measurement will be taken on finished compacted section only). |
| 133 | Cement concrete of proportion (1:4:8) in foundation and floors using 4cm (1½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming,watering, curing etc. complete including cost, conveyance,royalties and excluding GST of all materials with all labour,cess and T&P required for the work etc. complete in all respect. |
| 134 | 1” thick D.P.C with C.C(1:2:4) using 12mm. Chips etc. cpmplete as per direction of Engg-in-Charge . |
| 135 | R.C.C. work M-20 grade using 20mm and 10mm size black hard crusher broken granite chips including hoisting lowering laying and centring shuttering and finishing the exposed surface smooth providing groves or beds wherever necessary including cost, conveyance, royalties and excluding GST and cost of all materials and labour with T & P required for the work etc. complete in all respect excluding the cost of M.S. Rods or Tor steel and binding wires and labour charge for bending binding and tying grills as directed by the Engineer – in charge in Ground Floor. |
| 136 | Ground floor |
| 137 | (a) Column base |
| 138 | (b) Plinth band |
| 139 | (c) Lintel |
| 140 | (d) Column and beam |
| 141 | (e) Sun shade and Chajja |
| 142 | (f) Roof Slab |
| 143 | Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification including cost, conveyance and excluding GST of all materials with labour, cess and T&P etc. required for the work complete. |
| 144 | Ground floor |
| 145 | Fly Ash brick masonry in cement mortar (1:6) in Plinth & Foundation work using fly ash bricks of 23cm x 11cm x 8cm size having a crushing strength of not less than 75 kg/cm2 with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing including cost, conveyance, royalties and excluding GST of all materials with all labour, cess and T&P required for the work complete in all respect in all floors. |
| 146 | Fly Ash brick masonry in cement mortar (1:6) in Super strucutre work using fly ash bricks of 23cm x 11cm x8cm size having a crushing strength of not less than 75kg/cm2 with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similarsuch type of works with all necessary projections watering and curing including cost, conveyance, royalties and excluding GST of all materials with all labour, cess and T&P required for thework complete in all respect in all floors. |
| 147 | Ground floor |
| 148 | 12 mm (5/8”) thick cement plaster (1:6) finished smooth to inside rough surface of 9”/10” thick brick walls after rakingout the joints including watering and curing with cost withcost, conveyance, royalties and excluding GST of all materialswith all labour, T&P required for the work etc. complete. |
| 149 | Ground floor |
| 150 | 16 mm (½”) thick cement plaster (1:6) finished smooth to outside smooth surface of brick walls after raking out the jointincluding watering and curing with cost, conveyance, royaltiesand excluding GST of all materials with all labour and T&Prequired for the work etc. complete in all respect. |
| 151 | Ground floor |
| 152 | 2.5 cm thick grading concrete [1:2:2 ] on roof slab with 6 mm size chips including rubbing and polishing etc. complete including watering and curing with cost, conveyance, royaltiesand excluding GST of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 153 | Ground floor |
| 154 | 2.5cm. thick A.S.Flooring with C.C.1:2:4 using 12mm. size HBG crusher broken chips including punning,cost,conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge |
| 155 | Ground floor |
| 156 | Wall Priming one coats on new work with wall water bound primer of approved shade as per direction of Engg-in-Charge. |
| 157 | Ground floor |
| 158 | Finishing inside walls with Distemper of approved shade on new work two coats to give an even shade including watering and curing with cost, conveyance, royalties and excluding GST of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 159 | Ground floor |
| 160 | Painting two coats with weather seal coat paint over a coat of primer with water bound cement paint including cost, conveyance, excluding GST of all materials, labour and T&P etc. complete. |
| 161 | Ground floor |
| 162 | Supply fitting and fixing MS grill with Iron work wrought and put up in window grating including drilling holes in choukathas etc. complete as per direction of Engg-in-Charge . |
| 163 | Ground floor |
| 164 | Enamel Painting two coats with enamel paint over one coat of primer of approved quality etc. complete as per direction of Engg-in-Charge . |
| 165 | Ground floor |
| 166 | Recssed wiring to light point & Exhaust fan point with 1.5 sqmm FR PVC Insulated single core multistandard copper conductor of ISI marked with 20mm dia non metalic PVC flexible conduit with 5A ,250V modular type switch of ISI marked & ceiling rose of ISI marked mounted on MS BOX having front back light cover of suitable size, MS box with 1.5 sqmm FR PVC insulated single core multistrand copper conductor and earth wire including all accessories and connection as per direction of Engineer in charge(make of wire=Finollex/L& T/Anchor/Havels/V-guard/Great white)(deducting the cost of S/F of 100mmx100mmx60mm M.S Box with Backlite cover-1no) |
| 167 | Group-A(1.1.1.1-1.24.2) |
| 168 | Ressed wiring to Fan point in Group-B |
| 169 | Supply Installation testing and commissioning of 32A DP Main Switchs(IS 13940 part 3/1993) of following capacity on existing surface/wall mounting & complete with H.R.C fuse links inter connections earthig etc as required as per direction of Engineer Incharge (Make-seimens/HPL/Anchor/L & T Havels/C & S/R.K) |
| 170 | Wiring for circuit/sub main wiring alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked confirming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduct 1.6mm in recessed PVC conduit as required (Make of wire-Finolex/L & T /Anchor/Havels/V-guard) |
| 171 | do- 2x4sqmm +1x1.5sqmm(1.8.2) |
| 172 | do- 2x1.5sqmm +1x1.5sqmm(1.8.2) |
| 173 | S/F of 'B' series SP MCB of 6amp rating 240volt B series MCB for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection testing and commissioning etc as required single pole(SP)(2.6.1) |
| 174 | S/F of batten holder BK angle holder ISI marked including connection etc instead of celling rose(1.29-1.28) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysNov 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender