Housing Urban and Rular Development Government Departments Closing in 1 days TDR #58269171

Tender For Special Repair Works At Jnv: Biswanath (Assam)

Issued by Government Departments · Biswanath, Assam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
19 Nov 2026
1 days left
EMD
4.73 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Biswanath → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Special Repair Works At Jnv: Biswanath (Assam)

BOQ

Name of Work:- Special Repair works at JNV: Biswanath (Assam)
Sl. No. Item Description
1External WaterDistribution workCPVC Pipe
2(i) 100mm dia
3(ii) 80mm dia
4(iii) 50mm dia
5(iv) 40mm dia
6(v) 25mm dia
7Brick Masonry Chamber (600mm x600mm x 750mm)
8PTMT Ball Cock 25mm nominal box
9External Sewerage line works.Brick masonry Chamber of size455mm x 610mm x 450mm
10Septic Tanks – 200 users
11Septic Tanks – 100 users
12Providing & laying UPVC pipe & ISI make with necessary fittings
13(i) 100 mm dia
14(ii) 125 mm dia
15(iii) 140 mm dia
16Sub-Head-l (MCCB, MCB & DB'S)
17Wiring for light point/fan point /exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.xisting surface including dismantling as required. Group C
18Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned 1 copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
19a) 4 way (4 + 12), Double door
20b) 8 way (4 + 24), Double door
21Supplying and fixing following way, horizontal type three pole and 2 a 3 neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth |bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
22Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/1solator)
236 way, Double door
2416 way, Double door
25Supplying and fixing following rating, 240/415 volts, \\"C\\" curve, MCB suitable for inductive load of following poles in the existing DB complete with connections, testing and commissioning etc. as required. 5-32A SP MCB
26Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
27250 Amp, 36 KA,FPMCCB
28100 Amp, 30KA, FPMCCB
29SH-1I (Earthing & Lightning Conductor)
30Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangemnent and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
31Providing and fixing 25 mm X 5 mm G.l. strip in 40 mm dia GJ. pipe 8 from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
32Providing and fixing 25 mm X S mm G.I. strip on surface or in recess |for connections etc, as required.
33Providing and fixing of lightning conductor finial, made of 25 mm dia 10 |300 mm long. Gl. tube, having single prong at top, with 85 mm dia 6 mm thick G.J. base plate including holes etc. complete as required.
34Jointing copper / GI. tape (with another copper/ GI tape, base of the 11 |finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc. as required.
35Providing and fixing G.l. tape 20 mm X 3 mm thick on parapet or on 12 surface of wall for lightning conductor complete as required.(For horizontal run)
36Providing and fixing GJ. tape 20 mm X 3 mm thick on parapet or on 13 surface of wall for lightning conductor complete as required. (For vertical run)
37Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. 14 strip, 125 mm long, with 4 Nos. of G.J. bolts, nuts, chuck nuts and spring washers etc. complete as required.
38Providing and laying G.l. tape 32 mm X 6 mm from earth electrode directly in ground as required.
39Providing and fixing 6 SWG dia GI. wire on surface or in recess for |loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
40SH-III( Service Connection & Panel)
41Supplying and making end termination with brass compression gland land aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
424 X 25 sq. mm (28mm)
434 X 35 sq. mm (32mm)
444 X 50 sq. mm (35mm)
453½ X 120 sq. mm (45mm)
463½ X 185 sq. mm (57mm)
473½ X 300 sq. mm (70mm)
48Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming |to IS 14930, Part Il complete with fitting and cutting, jointing 22 etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
4963 mm dia (0D-63 mm & ID-51 mnm nominal)
5090 mm dia (0D-90 mm & ID-76 mm nominal)
51Supplying and fixing cable route marker with 10 cm X 10 cm X5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X6 mm angle iron, 60 cm long and fixing the same in ground as required.
52LED Flood Lights with G.I. Poles
53Erection metalic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and reffiling and secured with holding clamps, bolts, nuts,etc. as required. Above 8.00 metre and upto 10.0 metre
54Supplying Installation, Testing and Commissioning of Circular/ Rectangular/square LED RGB/ RGBWW/RGBNW/RGBA/RGBW (as per site requirement)Facade Floodlight/ Projector luminaire for facade lighting with Pressure Die-cast aluminium housing,powder-coated finish, with inbuilt driver of following wattage as given below. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°, the scale shall be provided for rotation degrees. The luminaire shall be IP66 protection also having silicon gasket between optical cover & LED chamber to ensure proper IP66 protection and impact resistance of IK 07. CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, under voltage, over voltage protection, driver inbuilt surge protection of 4KV and external surge protection (SPD)of 10 KV common mode/differential mode, Driver Efficiency>85%, EMI/EMC as per CISPR-15. There should be options of beam angles of 5/10/15/20/25/30/40/45/60 degree. Luminaire should have efficacy of minimum 35 lm/W for RGB/RGBNW/RGBWW/TNW and 65 lm/W for mono colour options. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor >0.9. Fixture shall be suitable to operate at an ambient temperature range of -10°C to +50°C. Lifetime of complete luminaire(LED ,Driver , Electrical & control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS: (IS 10322) with dully R Number marked and shall be complete with all necessary accessories required for proper working of fixture including connection/inter connection with weather proof ISI Marked copperconductor of minimum size 1.5sqmm connectioncables and accessories, Integral male/female waterproof connectors IP 68 etc. as required.The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer, RoHS Compliance.
5525 watt
5650 watt
57Switches and Panel Boards
582.Fabrication,supply,installation,testing and commissioning of cubicle type compartmentalized pedestal/floor mounted Power supply panel board of approved size and 450mm deep made out 2mm thick CRCA sheet steel with suitable size compartments,AL. bus bars,switchgears,voltmeters, ammeters with selector switches etc including powder coating painting with accessories, hardwares etc required for completeness and as per attached specification,direction of Engineer, PWD standards and Electrical Inspectorate standards
59(a) The panel board shall house: 1 No 4 pole 200A MCCB,20kA as Normal Supply Incomer, 4 pole 200A Al. busbar; 3 Nos Current transformer of 200/5A; 1 No Ammeter with selector switch; 1 No 0-500V Voltmeter with selector switch; 3 Nos LEDs: 4 Nos 4 pole,63A MCB,25kA as outgoing feeders; 4 Nos DP,40A MCB as outgoing feeders
60(c) The panel board shall house: 1 No 4 pole 200A MCCB,45kA as Normal Supply Incomer, 4 pole 200A Al. busbar; 3 Nos Current transformer of 200/5A; 1 No Ammeter with selector switch; 1 No 0-500V Voltmeter with selector switch; 3 Nos LEDs; 6Nos 4 pole,63A MCB,25kA as outgoing feeders; 4Nos DP, 40A MCB,KA as outgoing feeders
61(f) The panel board shall house: 1 No 4 pole 200A MCCB,65kA as Normal Supply Incomer, 4 pole 200A Al. busbar; 3 Nos Current transformer of 200/5A; 1 No Ammeter with selector switch; 1 No 0-500V Voltmeter with selector switch; 3 Nos LEDs; 7Nos 4 pole,63A MCB,25kA as outgoing feeders; 9Nos DP, 40A MCB,KA as outgoing feeders
623. Sypplying & fixing of Load Kontaket Miniature Circuit Breakers (RX3 MCB's)
63B. Double pole (b) 40 Amp
64C. Triple pole
65(b) 40 Amp
66(c) 50-63 Amp
67D. Four pole(c) 50-63 Amp
6857. Supplying fitting and fixing of Moulded case circuit Breaker (MCCBs) of the following Amp Capacity
69A.(ii) Three pole(a) 16-63 Amp
70F.(ii) Three pole(a) 300 Amp
71UG Cables
721. Providing laying connection testing & commissioning testing & commissioning of the following sizes of 1100V PVC/XLPE armoured Cables with Aluminium Conductor as per ISI Code in bracket,trenches,M.S. cable rods and including the cost of digging of trenches,sand cushioning with laying etc and refilling the same in layers or by supporting them in walls and all other accessories as required
73(l) With 4 core 25sqmm
74(m) With 4 core 35sqmm
75(n) With 4 core 50sqmm
76(f) With 3.5 core 120sqmm
77(h) With 3.5 core 185sqmm
78(i) With 3.5 core 185sqmm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58269171
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 19-11-2026
Authority
Authority Name Meghalaya Government Construction Corporation Limited
Work Description Tender For Special Repair Works At Jnv: Biswanath (Assam)
Basic Detail
Tender No 48 of 27-10-2026
Bidding Type Tender
Location
City Biswanath
State Assam
Key Dates
Publish Date 29 Oct 2026
Submission Date 19 Nov 2026
Open Date 19 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee 10000
EMD 4.73 Lakhs
Exemption Not Available
Document List
b39a9525-a11b-4dbb-8c26-40f8cd2f5f87.html
BOQ_2260.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Nov 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

b39a9525-a11b-4dbb-8c26-40f8cd2f5f87.html

xls

BOQ_2260.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender