Tender For Special Repair Works At Jnv: Biswanath (Assam)
Tender Value
Ref. Documents
Estimated cost
Bid Submission
19 Nov 2026
1 days left
EMD
4.73 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Biswanath → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair Works At Jnv: Biswanath (Assam)
BOQ
| Sl. No. | Item Description |
| 1 | External WaterDistribution workCPVC Pipe |
| 2 | (i) 100mm dia |
| 3 | (ii) 80mm dia |
| 4 | (iii) 50mm dia |
| 5 | (iv) 40mm dia |
| 6 | (v) 25mm dia |
| 7 | Brick Masonry Chamber (600mm x600mm x 750mm) |
| 8 | PTMT Ball Cock 25mm nominal box |
| 9 | External Sewerage line works.Brick masonry Chamber of size455mm x 610mm x 450mm |
| 10 | Septic Tanks – 200 users |
| 11 | Septic Tanks – 100 users |
| 12 | Providing & laying UPVC pipe & ISI make with necessary fittings |
| 13 | (i) 100 mm dia |
| 14 | (ii) 125 mm dia |
| 15 | (iii) 140 mm dia |
| 16 | Sub-Head-l (MCCB, MCB & DB'S) |
| 17 | Wiring for light point/fan point /exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.xisting surface including dismantling as required. Group C |
| 18 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned 1 copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 19 | a) 4 way (4 + 12), Double door |
| 20 | b) 8 way (4 + 24), Double door |
| 21 | Supplying and fixing following way, horizontal type three pole and 2 a 3 neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth |bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door |
| 22 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/1solator) |
| 23 | 6 way, Double door |
| 24 | 16 way, Double door |
| 25 | Supplying and fixing following rating, 240/415 volts, \\"C\\" curve, MCB suitable for inductive load of following poles in the existing DB complete with connections, testing and commissioning etc. as required. 5-32A SP MCB |
| 26 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 27 | 250 Amp, 36 KA,FPMCCB |
| 28 | 100 Amp, 30KA, FPMCCB |
| 29 | SH-1I (Earthing & Lightning Conductor) |
| 30 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangemnent and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 31 | Providing and fixing 25 mm X 5 mm G.l. strip in 40 mm dia GJ. pipe 8 from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 32 | Providing and fixing 25 mm X S mm G.I. strip on surface or in recess |for connections etc, as required. |
| 33 | Providing and fixing of lightning conductor finial, made of 25 mm dia 10 |300 mm long. Gl. tube, having single prong at top, with 85 mm dia 6 mm thick G.J. base plate including holes etc. complete as required. |
| 34 | Jointing copper / GI. tape (with another copper/ GI tape, base of the 11 |finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc. as required. |
| 35 | Providing and fixing G.l. tape 20 mm X 3 mm thick on parapet or on 12 surface of wall for lightning conductor complete as required.(For horizontal run) |
| 36 | Providing and fixing GJ. tape 20 mm X 3 mm thick on parapet or on 13 surface of wall for lightning conductor complete as required. (For vertical run) |
| 37 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. 14 strip, 125 mm long, with 4 Nos. of G.J. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 38 | Providing and laying G.l. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 39 | Providing and fixing 6 SWG dia GI. wire on surface or in recess for |loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 40 | SH-III( Service Connection & Panel) |
| 41 | Supplying and making end termination with brass compression gland land aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 42 | 4 X 25 sq. mm (28mm) |
| 43 | 4 X 35 sq. mm (32mm) |
| 44 | 4 X 50 sq. mm (35mm) |
| 45 | 3½ X 120 sq. mm (45mm) |
| 46 | 3½ X 185 sq. mm (57mm) |
| 47 | 3½ X 300 sq. mm (70mm) |
| 48 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming |to IS 14930, Part Il complete with fitting and cutting, jointing 22 etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 49 | 63 mm dia (0D-63 mm & ID-51 mnm nominal) |
| 50 | 90 mm dia (0D-90 mm & ID-76 mm nominal) |
| 51 | Supplying and fixing cable route marker with 10 cm X 10 cm X5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 52 | LED Flood Lights with G.I. Poles |
| 53 | Erection metalic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and reffiling and secured with holding clamps, bolts, nuts,etc. as required. Above 8.00 metre and upto 10.0 metre |
| 54 | Supplying Installation, Testing and Commissioning of Circular/ Rectangular/square LED RGB/ RGBWW/RGBNW/RGBA/RGBW (as per site requirement)Facade Floodlight/ Projector luminaire for facade lighting with Pressure Die-cast aluminium housing,powder-coated finish, with inbuilt driver of following wattage as given below. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°, the scale shall be provided for rotation degrees. The luminaire shall be IP66 protection also having silicon gasket between optical cover & LED chamber to ensure proper IP66 protection and impact resistance of IK 07. CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, under voltage, over voltage protection, driver inbuilt surge protection of 4KV and external surge protection (SPD)of 10 KV common mode/differential mode, Driver Efficiency>85%, EMI/EMC as per CISPR-15. There should be options of beam angles of 5/10/15/20/25/30/40/45/60 degree. Luminaire should have efficacy of minimum 35 lm/W for RGB/RGBNW/RGBWW/TNW and 65 lm/W for mono colour options. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor >0.9. Fixture shall be suitable to operate at an ambient temperature range of -10°C to +50°C. Lifetime of complete luminaire(LED ,Driver , Electrical & control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS: (IS 10322) with dully R Number marked and shall be complete with all necessary accessories required for proper working of fixture including connection/inter connection with weather proof ISI Marked copperconductor of minimum size 1.5sqmm connectioncables and accessories, Integral male/female waterproof connectors IP 68 etc. as required.The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer, RoHS Compliance. |
| 55 | 25 watt |
| 56 | 50 watt |
| 57 | Switches and Panel Boards |
| 58 | 2.Fabrication,supply,installation,testing and commissioning of cubicle type compartmentalized pedestal/floor mounted Power supply panel board of approved size and 450mm deep made out 2mm thick CRCA sheet steel with suitable size compartments,AL. bus bars,switchgears,voltmeters, ammeters with selector switches etc including powder coating painting with accessories, hardwares etc required for completeness and as per attached specification,direction of Engineer, PWD standards and Electrical Inspectorate standards |
| 59 | (a) The panel board shall house: 1 No 4 pole 200A MCCB,20kA as Normal Supply Incomer, 4 pole 200A Al. busbar; 3 Nos Current transformer of 200/5A; 1 No Ammeter with selector switch; 1 No 0-500V Voltmeter with selector switch; 3 Nos LEDs: 4 Nos 4 pole,63A MCB,25kA as outgoing feeders; 4 Nos DP,40A MCB as outgoing feeders |
| 60 | (c) The panel board shall house: 1 No 4 pole 200A MCCB,45kA as Normal Supply Incomer, 4 pole 200A Al. busbar; 3 Nos Current transformer of 200/5A; 1 No Ammeter with selector switch; 1 No 0-500V Voltmeter with selector switch; 3 Nos LEDs; 6Nos 4 pole,63A MCB,25kA as outgoing feeders; 4Nos DP, 40A MCB,KA as outgoing feeders |
| 61 | (f) The panel board shall house: 1 No 4 pole 200A MCCB,65kA as Normal Supply Incomer, 4 pole 200A Al. busbar; 3 Nos Current transformer of 200/5A; 1 No Ammeter with selector switch; 1 No 0-500V Voltmeter with selector switch; 3 Nos LEDs; 7Nos 4 pole,63A MCB,25kA as outgoing feeders; 9Nos DP, 40A MCB,KA as outgoing feeders |
| 62 | 3. Sypplying & fixing of Load Kontaket Miniature Circuit Breakers (RX3 MCB's) |
| 63 | B. Double pole (b) 40 Amp |
| 64 | C. Triple pole |
| 65 | (b) 40 Amp |
| 66 | (c) 50-63 Amp |
| 67 | D. Four pole(c) 50-63 Amp |
| 68 | 57. Supplying fitting and fixing of Moulded case circuit Breaker (MCCBs) of the following Amp Capacity |
| 69 | A.(ii) Three pole(a) 16-63 Amp |
| 70 | F.(ii) Three pole(a) 300 Amp |
| 71 | UG Cables |
| 72 | 1. Providing laying connection testing & commissioning testing & commissioning of the following sizes of 1100V PVC/XLPE armoured Cables with Aluminium Conductor as per ISI Code in bracket,trenches,M.S. cable rods and including the cost of digging of trenches,sand cushioning with laying etc and refilling the same in layers or by supporting them in walls and all other accessories as required |
| 73 | (l) With 4 core 25sqmm |
| 74 | (m) With 4 core 35sqmm |
| 75 | (n) With 4 core 50sqmm |
| 76 | (f) With 3.5 core 120sqmm |
| 77 | (h) With 3.5 core 185sqmm |
| 78 | (i) With 3.5 core 185sqmm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayNov 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender