Housing Urban and Rular Development Government Departments Closing in 16 days TDR #58268770

Tender For Construction Of Canopy For B Site Ro/Fuel Station, Spinning Mill At Iie Kashipur, (U.S.Nagar) Uttarakhand

Issued by Government Departments · Udam Singh Nagar, Uttarakhand
Tender Value
26.33 Lakhs
Estimated cost
Bid Submission
17 Nov 2026
16 days left
EMD
52700
Bank guarantee accepted
Document Fee
2360
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udam Singh Nagar → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Canopy For B Site Ro/Fuel Station, Spinning Mill At Iie Kashipur, (U.S.Nagar) Uttarakhand

BOQ

Name of Work:- Construction of Canopy for B site RO/Fuel Station, Spinning Mill at IIE Kashipur, (U.S.Nagar) Uttarakhand
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
2Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials All kinds of soil
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
4Centering and shuttering including strutting, propping etc. and removal of form for
5Foundations, footings, bases of columns, etc. for mass concrete
6Columns, Pillars, Piers, Abutments, Posts and Struts
7Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
81:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
9Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
10Thermo-Mechanically Treated bars of grade Fe-500D or more.
11Providind and Fixing Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of Cold rolled steel confirming to IS:513-2008 of base metal thickness 0.50mm, having Yield stress of Min 275 Mpa. Steel Surface shall have hot dip metallic coating of Al-Zinc alloy comprising 55% Aluminium, 43.5 Zinc and 1.5% Silicon as per the ASTM-A792M, with total mass of coating on both sides shall be 150gms/sqm. The steel shall have organic coating wiht silicon Modified Polyester (SMP) Super Durable Polyester (SDP) paint on continous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns SMP/SDP paint over epoxy primer and back side 8-10Microns SMP/SDP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.58MM. Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transporation and should be supplied in single length up to 6m or as desired by Engineer-in-Charge.
12PROFILE Sheet for roofing
13plain Ridges plain (500 - 600mm)
14Flashings/ Aprons.( Upto 600 mm)
15P/F 700mm wide rain water gutter fabricated out of 1200mm wide roll of 18 gauge aluminium sheet
16Providing and fixing 150F/200F flush panel. (pre-coated steel) False Ceiling made of Cold rolled sheet conforming to IS 513 having minimum yield stress and tensile stress as 240Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shal be 0.45mm and 0.5mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as pr IS277 with total mass of coating on both sides shall be 120gms/sqm. The steel shall have organic coating wih Regular Modified Polyester (RMP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-0 Microns RMP paint over epoxy primer. Total coated Thickness (TCT) shall be 0.50 MM for Ceiling Paneland 0.60MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-Charge. The ceiling panel shall be clipped into carriers which are suspended from steel.
17Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
18In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
19Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
20110 mm diameter
21Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
22Bend 87.5° 110 mm bend
23Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
24New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution
25Cabling and allied work 3corex1.5 sq.m copper cable FRLS outer sheathed of 1.1 KV grade of upto 35 sqmm size direct in existing RCC/Hume pipe
26Cable Termination gland Non- FLP heavy duty double compression gland, end termination, crimpng type lugs & allied jointing material etc. 3 corex 1.5sq.m
27S/f of SP MCB upto 32 Amp
2810S.W.G. Cu. Wire
29Supply & Fixing of flame proof junction box(4 way)
30SITC of recess mounted linear LED lights 80 watt Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58268770
AUTHORITY Government Departments
TENDER VALUE 26.33 Lakhs
LAST DATE 17-11-2026
Authority
Authority Name State Infrastructure And Industrial Development Corporation Of Uttarakhand Limited
Work Description Tender for Construction Of Canopy For B Site Ro/Fuel Station, Spinning Mill At Iie Kashipur, (U.S.Nagar) Uttarakhand
Basic Detail
Tender No 04/SIIDCUL/I.I.E. Kashipur/2026
Bidding Type Tender
Location
City Udam Singh Nagar
State Uttarakhand
Key Dates
Publish Date 29 Oct 2026
Submission Date 17 Nov 2026
Open Date 17 Nov 2026
Finance
Tender Value 26.33 Lakhs
Tender Fee 2360
EMD 52700
Exemption Not Available
Document List
49324af1-3855-4c0f-8646-187c6a14e21d.html
BOQ_119869.xls
TenderNotice.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Nov 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

49324af1-3855-4c0f-8646-187c6a14e21d.html

xls

BOQ_119869.xls

pdf

TenderNotice.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender