Housing Urban and Rular Development Government Departments Closing in 3 days TDR #58268429

Tender For Work Of Installation Of Solar Rooftop Panels On Government Buildings Under Public Works Department In Muzaffarnagar District.

Issued by Government Departments · Muzaffarnagar, Uttar Pradesh
Tender Value
10.54 Lakhs
Estimated cost
Bid Submission
07 Nov 2026
3 days left
EMD
1.06 Lakhs
Bank guarantee accepted
Document Fee
766
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Muzaffarnagar → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Work Of Installation Of Solar Rooftop Panels On Government Buildings Under Public Works Department In Muzaffarnagar District.

BOQ

Name of Work:- Janpad Muzaffarnagar me Lok Nirman Vibhag ke antargat shaaskiya bhavno par Solar Roofatop Panel ke sthapna ka karya.
Sl. No. Item Description
1Lok Nirman Vibhag ke antargat shaaskiya bhavno (karyalay adhishasi abhiyanta prantiya khand Janpad Muzaffarnagar) par Solar Roofatop Panel ke sthapna ka karya.
2SITC of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required. High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, Complete in all respect. All Specifications as per CPWD DSR E&M 2025 item 17.1. And including Cleaning, Operation & Maintenance of Solar Roof Top Panel System for five years after one year DLP (Total for six years).
3Lok Nirman Vibhag ke antargat shaaskiya bhavno (Nireekshan Bhavan Jaansath Janpad Muzaffarnagar) par Solar Roofatop Panel ke sthapna ka karya.
4SITC of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required. High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, Complete in all respect. All Specifications as per CPWD DSR E&M 2025 item 17.1. And including Cleaning, Operation & Maintenance of Solar Roof Top Panel System for five years after one year DLP (Total for six years).
5Lok Nirman Vibhag ke antargat shaaskiya bhavno (Navnirmit Nireekshan Bhavan Janpad Muzaffarnagar) par Solar Roofatop Panel ke sthapna ka karya.
6SITC of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required. High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, Complete in all respect. All Specifications as per CPWD DSR E&M 2025 item 17.1. And including Cleaning, Operation & Maintenance of Solar Roof Top Panel System for five years after one year DLP (Total for six years).
7Lok Nirman Vibhag ke antargat shaaskiya bhavno (Nireekshan Bhavan Budhaana Janpad Muzaffarnagar) par Solar Roofatop Panel ke sthapna ka karya.
8SITC of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required. High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, Complete in all respect. All Specifications as per CPWD DSR E&M 2025 item 17.1. And including Cleaning, Operation & Maintenance of Solar Roof Top Panel System for five years after one year DLP (Total for six years). Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58268429
AUTHORITY Government Departments
TENDER VALUE 10.54 Lakhs
LAST DATE 07-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Work Of Installation Of Solar Rooftop Panels On Government Buildings Under Public Works Department In Muzaffarnagar District.
Basic Detail
Tender No 1405/3WE(SRE)-47/2026 Dt-16/10/2026
Bidding Type Tender
Location
City Muzaffarnagar
State Uttar Pradesh
Key Dates
Publish Date 29 Oct 2026
Submission Date 07 Nov 2026
Open Date 07 Nov 2026
Finance
Tender Value 10.54 Lakhs
Tender Fee 766
EMD 1.06 Lakhs
Exemption Not Available
Document List
85b3dc44-5402-419e-adec-55e47af7207d.html
BOQ_2276307.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Nov 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

85b3dc44-5402-419e-adec-55e47af7207d.html

xls

BOQ_2276307.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender