Tender For Development Of Sri Monglishwar Asthapan Complex At Sirnoo Pulwama.
Tender Value
1.55 Crore
Estimated cost
Bid Submission
17 Nov 2026
14 days left
EMD
3.10 Lakhs
Bank guarantee accepted
Document Fee
2600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pulwama → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Development Of Sri Monglishwar Asthapan Complex At Sirnoo Pulwama.
BOQ
| Sl. No. | Item Description |
| 1 | Dharamshala |
| 2 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m² on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 4 | P/L of stone soling incl. ramming, hand packing and all carriages, complete job in geocell, trenches, foundation etc. |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 6 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 7 | Supplying and filling of RBM in plinth incl. spreading, dressing, watering with all carriage etc complete. |
| 8 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 9 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at plinth beam level and DPC level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, pillars, piers, abutments, posts and struts. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. |
| 16 | Edges of slabs and breaks in floors and walls: Under 20 cm wide. |
| 17 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in: Cement mortar 1:4 (1 cement : 4 coarse sand) Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. |
| 18 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Imported KD wood or equivalent. |
| 19 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, complete as per direction of Engineer-in-charge. Imported kail wood 35mm thick. |
| 20 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Imported kail wood. |
| 21 | Providing and fixing glass panes with required beading and glazing clips in doors, windows, clerestory windows, all complete with: 3mm glass panes. |
| 22 | Providing and fixing Wire gauze with required beading and clips in doors, windows, clerestory windows, all complete with: Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia wire and 1.4 mm wire aperture with matching wood beading. |
| 23 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete: 125 mm. |
| 24 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc.: 75mm. |
| 25 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete: 150x10 mm. |
| 26 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete: 100x10 mm. |
| 27 | Providing and fixing ISI marked oxidized M.S. sliding door bolts (Aldrop) with nuts and screws etc. complete: 300x16 mm. |
| 28 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: Single rubber stopper. |
| 29 | Providing and fixing 40x5mm thick iron holdfast 40mm long. |
| 30 | Providing and fixing ISI marked oxidized M.S. air hook with necessary screws equivalent. |
| 31 | 12mm Cement plaster of mix: 1:4 (1 cement : 4 fine sand). |
| 32 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 33 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank: 1000 ltrs. |
| 35 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete: Size of tile 600x600 mm. |
| 36 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers' specifications: Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75 liter/10sqm. |
| 37 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid. |
| 38 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 39 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 40 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: 32 MM DIA. |
| 41 | Providing and fixing jali for water closet or wash basin including P.V.C waste fittings complete. |
| 42 | Providing and fixing PVC pipes class C pipe incl. soil waste and vent pipes: 100mm. |
| 43 | Providing and fixing PVC pipes class C pipe incl. soil waste and vent pipes: 75mm. |
| 44 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. Concealed fixing with clamps at 1.00 m spacing: PN-16 pipe, 16mm OD (SDR-7.4). |
| 45 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. Concealed fixing with clamps at 1.00 m spacing: PN-16 pipe, 25mm OD (SDR-7.4). |
| 46 | P/F PVC Fittings of approved make as per directions of Eic. |
| 47 | PVC Door Tee 100mm size (Prince Make) complete. |
| 48 | PVC Door Tee 75mm size (Prince Make) complete. |
| 49 | PVC collar 100mm (Prince Make) complete. |
| 50 | PVC collar 75mm (Prince Make) complete. |
| 51 | PVC Reducer 100x75mm (Prince Make) complete. |
| 52 | PVC Floor Trap 100 mm size (Prince Make) complete. |
| 53 | PVC Plain Bend 100 mm size (Prince Make) complete. |
| 54 | PVC Plain Bend 75 mm size (Prince Make) complete. |
| 55 | PVC Door bend 100mm (Prince Make) complete. |
| 56 | PVC Door bend 75mm (Prince Make) complete. |
| 57 | Providing & Fixing C.P fittings of standard quality and app make incld all fittings fixtures etc complete as per directions of EIC. |
| 58 | Providing & Fixing C.P fittings: Nipples of different sizes. |
| 59 | Providing & Fixing C.P fittings: Bib cock. |
| 60 | Providing & Fixing C.P fittings: Angle valve. |
| 61 | Providing & Fixing C.P fittings: Ball valve. |
| 62 | Providing & Fixing C.P fittings: Coupling. |
| 63 | Providing & Fixing C.P fittings: Basin Mixer. |
| 64 | Providing & Fixing: PTMT liquid soap container. |
| 65 | Providing & Fixing: CP Gratings. |
| 66 | Providing & Fixing C.P fittings: Wall Mixer. |
| 67 | Construction of 9\\" thick brick masonary manholes in cement mortar (1:4) mix, foundation cement concrete (1:4:8), 12 mm thick inside cement plaster with finishing, making channels in cement concrete (1:2:4) incl. cost of manhole covers PVC ISI mark with frame size (1'-6\\"x1'-6\\"x1'-6\\") inside size. |
| 68 | P/F of Geysers 25-Litre 2000-Watt Storage Water Heater (White) incl. all fittings and fixtures make: venus, jacquar, racold or equivalent. |
| 69 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete (Welded). |
| 70 | P/F Hi rib color coated corrugated galvanized PPGI sheets 1000 to 1020mm cover width 28-35mm high crests at 250 to 255mm TCT high tensile SMP Galvalume steel with silicon modified polyester coating of approved colour of total thickness of 35 micron comprising 20 micron exterior coat of SMP over 5 micron polyester back coat over 5 micron primer coats on both surfaces incld. side and end lap and using 8mm galvalume hex self drilling fastener on each crest of sheet for connection with purlins and seam bolts at 300mm centers on all side and end laps etc. 0.5mm THICK (TATA, JSW OR EQ brand) I/C ALL CARRIAGES/H/LOAD i/c 60cm wide ridges and valleys wherever required incl. all fittings and fixtures in roof sheeting (TILE PROFILE). |
| 71 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete. |
| 72 | Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing, polishing and curing complete: Raj Nagar plain 18mm. |
| 73 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: 510x1040mm bowl depth 250mm. |
| 74 | Supplying and laying medium class PVC conduit pipe for point wiring recessed/surface system, including standard PVC conduit accessories like bends, tees, junction boxes: 20 mm diameter. |
| 75 | Supplying and laying medium class PVC conduit pipe recessed/surface system with all premium PVC accessories: 25 mm diameter (Designed for circuit runs). |
| 76 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-in charge: 1:3:6 or richer mix (i/c equivalent design mix). |
| 77 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In mud mortar. |
| 78 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead: Of sectional area 40 sqcm. and above. |
| 79 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of: G.S. Sheet. |
| 80 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead: Of area of 3 sqm. and below. |
| 81 | Carriages for Different Materials: Crushed Aggregate Avg Lead of 10 kms. |
| 82 | Carriages for Different Materials: Sand Avg Lead of 10 kms. |
| 83 | Carriages for Different Materials: Bricks (Avg Lead 25 km) |
| 84 | Mandir |
| 85 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m² on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil. |
| 86 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 87 | P/L of stone soling incl. ramming, hand packing and all carriages, complete job in geocell, trenches, foundation etc. |
| 88 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) |
| 89 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1.5:3 (1 cement: 1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 90 | Supplying and filling of RBM in plinth incl. spreading, dressing, watering with all carriage etc complete |
| 91 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) |
| 92 | Coursed Rubble Masonry with hard stone in foundation and plinth and curing complete with: Lime mortar 1:1:1 (1 Lime putty: 1 Surkhi: 1 Fine sand) first sort |
| 93 | Coursed rubble masonry with hard stone in superstructure above plinth level and upto floor five level including curing complete with: Lime mortar 1:1:1 (1 Lime putty: 1 Surkhi: 1 Fine sand) ist sort |
| 94 | Providing and fixing 25 mm thick natural Devri stone tiles/slabs for cladding, of approved colour, texture and quality, machine cut and properly dressed, fixed over prepared masonry/RCC surface with 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), including cutting, fitting, plumbing, leveling and alignment, filling and pointing joints with cement slurry/mortar of matching shade, necessary SS/GI mechanical clamps/anchors, scaffolding, curing, rubbing, cleaning and finishing the exposed surface to a smooth honed/matt finish, complete in all respects as directed by the Engineer-in-Charge. |
| 95 | Extra for carving on Devri stones: Providing and executing carving work up to 25 mm depth on Devri stones of approved design, over the basic stone fixing work, including skilled mason labour, tools, dressing, finishing, and all materials required to achieve the approved design, complete in all respects as directed by the Engineer-in-Charge. |
| 96 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1.5:3 (1 cement: 1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 97 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 98 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at plinth beam level and DPC level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 99 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. |
| 100 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 101 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, pillars, piers, abutments, posts and struts. |
| 102 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. |
| 103 | Providing, supplying and fixing decorative temple Shikhar/finial in bronze metal, of approved design, pattern and dimensions, including casting/fabrication in bronze, all ornamental mouldings, decorative motifs, joints, internal supporting framework, base plates, clamps, nuts, bolts, welding/brazing, anchoring and fixing accessories, surface finishing, polishing/patina treatment and all labour, scaffolding and incidental works, complete as per architectural drawings and instructions of Engineer-in-Charge. |
| 104 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): imported KD wood or equivalent. |
| 105 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately). imported kail wood 35mm Thick |
| 106 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. imported kail wood |
| 107 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125 mm |
| 108 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete. 150x10 mm |
| 109 | Providing and fixing ISI marked oxidized M.S. sliding door bolts (Aldrop) with nuts and screws etc. complete: 300x16 mm |
| 110 | Providing and fixing 40x5mm thick iron holdfast 40mm long |
| 111 | Carriages for Different Materials: Crushed Aggregate Avg Lead of 10kms |
| 112 | Carriages for Different Materials: Sand Avg 10kms |
| 113 | \\"Fencing and allied civil works |
| 114 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m² on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil. |
| 115 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 116 | P/L of stone soling incl. ramming, hand packing and all carriages, complete job in geocell, trenches, foundation etc. |
| 117 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) |
| 118 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1.5:3 (1 cement: 1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 119 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with: 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) |
| 120 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1.5:3 (1 cement: 1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 121 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, pillars, piers, abutments, posts and struts. |
| 122 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in: Cement mortar 1:4 (1 cement: 4 coarse sand) Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 123 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at plinth beam level and DPC level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 124 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. |
| 125 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 126 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm |
| 127 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. With G.I. barbed wire |
| 128 | Painting steel work with deluxe multi surface paint of required shade to give an even shade. Two or more coats applied @ 0.90 litre/10sqm over an under coat of primer applied @ 0.80 litre/10sqm of approved brand and manufacture |
| 129 | 12 mm thick 1:4 cement sand plaster |
| 130 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 131 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-in charge: 1:3:6 or richer mix (i/c equivalent design mix) |
| 132 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead |
| 133 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete |
| 134 | Carriages for Different Materials: Crushed Aggregate Avg Lead of 10kms |
| 135 | Carriages for Different Materials: Sand Avg Lead of 10kms |
| 136 | Carriages for Different Materials: Bricks (Avg Lead 25 km) |
| 137 | Electrification |
| 138 | Wiring for lighting points/fan points/ exhaust fan points/call bell points with 1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch , modular plate and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent make ) incl. cost of conduit. Group A |
| 139 | Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing, etc. as required. (Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent ) incl. cost of conduit |
| 140 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider LIvia /Crabtree athena make.) |
| 141 | Supplying and fixing of suitable size GI box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 2 nos , 3 pin 5/6 A modular socket outlet and 2 no. 5/6A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or eq.) |
| 142 | Point wiring for 5A -10A socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires in recessed or surface conduiting system and earthing the point with 1 x 2.5 sq. mm single core copper wire (loop earthing),(Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent) incl. cost of conduit |
| 143 | Supplying and fixing of modular sockets/ indicators/switches on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or eq.) i.3 pin 5A - 10A socket. |
| 144 | 3 pin 5A - 10A socket. |
| 145 | indicator. |
| 146 | Supply installation testing and commissioning of 18 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Havel's /Wipro make / sample to be approved before installation.. |
| 147 | Emergency LED Light Fitting: Supply, installation, testing and commissioning of premium quality self-contained LED emergency light fitting, 3–5 W LED, with integrated maintenance-free rechargeable battery and automatic mains-failure changeover, providing minimum 90 minutes emergency operation, complete with battery charging circuit, charge/healthy status indicator, suitable for 230 V, 50 Hz AC supply, and capable of achieving the required emergency illumination levels at the designated location, complete with mounting arrangement, fixing hardware, wiring terminals and all necessary accessories. |
| 148 | Supply of 2 ft long, 10 W LED mirror luminaire, wall-mounted type, delivering minimum system lumen output of 1000 lumens with minimum system efficacy of 100 lm/W. The luminaire housing shall be made of extruded aluminium and the diffuser shall be of PMMA/PC. The operating CCT shall be 4000K with CRI ≥ 80 and SDCM < 5.The luminaire shall be complete with BIS registered electronic driver suitable for input voltage range of 150 V to 270 V AC, with THD ≤ 10% and power factor ≥ 0.95. LED life shall be minimum 50,000 hours at L70 criteria. The luminaire shall have IP20 protection.The LED driver shall be easily available in India for maintenance and replacement. LEDs shall be of SMD type. The luminaire shall have minimum surge protection of 2.5 kV.The luminaire shall be supported with LM-79 and LM-80 test reports issued by accredited laboratories and shall comply with photobiological safety standards (IEC 62471). |
| 149 | Supply installation testing and commissioning of 12W LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W . The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt. approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures also. (Philips/ Havel's /Wipro make / sample to be approved before installation). |
| 150 | Providing, fixing, testing and commissioning of 9 Watt LED lamp (B22 cap), BEE/ISI approved, 230 V, cool daylight (6500 K), minimum efficacy 100 lm/W, complete with heavy-duty brass batten holder, including all fixing accessories, making electrical connections, testing and commissioning as required at site. (Havells/Wipro/Philips/Crompton/Bajaj or equivalent).Approved makes: Signify (Philips), Wipro Lighting, Havells, Crompton, Jaquar Lighting, Bajaj Electricals, LEDVANCE or equivalent approved make. |
| 151 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, , ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, suitable long down rod, 2 no. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Atomberg/Orient/USHA /Havells /Crompton / OR OEMs/ firms holding ISO 9001 certification (Quality Management System) as directed by engineer incharge. |
| 152 | Supply and fixing of two module stepped electronic fan regulator on the existing modular plate switch box, incl. connections but excluding modular plate etc. as reqd. |
| 153 | Supply, installation, testing and commissioning of 200-250 mm sweep shutter type exhaust fans, incl. cost of ceiling rose and making of space in walls/ windows as per site and necessary connections. (Havells/ Philips/ Crompton). |
| 154 | Supplying and fixing of modular blanking plates on existing modular plate and switch box ,excluding modular plate as required. |
| 155 | Wiring for sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, incl. cost of conduits(Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent). |
| 156 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire ( Lighting submain/ three phase points) |
| 157 | 2 x 1.5 sq.mm + 1x 1.5 sq. mm earth wire |
| 158 | 2 x 2.5 sq.mm + 1x 2.5 sq. mm earth wire |
| 159 | 2 x 4 sq.mm + 1x 4 sq. mm earth wire |
| 160 | Supply and fixing of 16 way Double door surface/ recess mounting , Horizontal type, 240 V, SPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. . |
| 161 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).4 way (4 + 12), Double door |
| 162 | 4 way (4 + 12), Double door |
| 163 | 6 way (4 + 18), Double door |
| 164 | Supply and fixing of 16 way Double door surface/ recess mounting , Horizontal type, 240 V, SPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. . |
| 165 | Supply, installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 166 | Supply, installation, testing and commissioning of 32/40 A DP rating 240V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 167 | Supply, installation, testing and commissioning of 63 A DP rating 240V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 168 | Supply, installation, testing and commissioning of 40-63amp TPN MCB 10 KA Legrand/ Schneider /ABB/L&T sample to be approved before installation.. |
| 169 | Providing of chemical earthing as per IS standards by way of digging 8 feet pit then embedding 2.5 mtr. Long GI earthing electrode, 60 mm dia. Connecting the plate with main control board by 10 SWG Copper wire with 1/2” dia. Full thread brass nut and bolts and washers, refilling the pit with chemical compound. |
| 170 | Supply, laying, testing and commissioning of 1.1 kV grade, 95 sq.mm 3.5 Core Aluminium conductor XLPE insulated, PVC sheathed, armoured cable conforming to IS 7098 (Part-1), with latest amendments, of Havells/Polycab/KEI/Finolex or equivalent approved make, including laying, dressing, routing, testing and commissioning, complete with brass compression glands and suitable copper lugs for end termination, as directed by Engineer-in-Charge. |
| 171 | 70 sq.mm 3.5 Core MAIN CABLE |
| 172 | 50 sq.mm 3.5 Core |
| 173 | Supply and fixing of fan deep made of heavy gauge sheet in RCC slabs. |
| 174 | Supply, Installation, Testing and Commissioning of DOL Starter suitable for 1 HP, 230V, single-phase, 50Hz water pump, comprising powder-coated enclosure, suitably rated MPCB, magnetic contactor, thermal overload protection, ON/OFF push buttons, indication lamps, terminals, internal power/control wiring, cable glands and earthing arrangement. Complete with Manual/Automatic selector and automatic ON/OFF control through float switch/level controller, including all necessary control wiring and accessories. Complete assembly shall be installed, tested and commissioned for satisfactory operation. Make: L&T, Schneider, Siemens, ABB, Havells, Legrand, BCH, C&S, Indo Asian, Polycab or equivalent reputed make. |
| 175 | PANELS AND ALLIED ITEMS |
| 176 | Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement) |
| 177 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. |
| 178 | Normal INCOMING: |
| 179 | a)200 A 4P MCCB 36 KA including spreader links,( Adjustable thermal and magnetic release) Legrand/ Schneider /ABB make/ sample to be approved before installation.. |
| 180 | b) 4 No. of Aluminium Bus Bar of 300 Amp. |
| 181 | c)Digital meters and phase indicators -1 set. |
| 182 | d) on load Change over switch 160 Amp for generator.Front operated. |
| 183 | e) 4 No. of Aluminium Bus Bar of 200 Amp. |
| 184 | 63 A DP RCCB (30 mA) = 1 NO |
| 185 | Type 2, 3P+N, suitable for 415 V system |
| 186 | c)Digital meters and phase indicators -1 set. |
| 187 | OUTGOING: |
| 188 | a)100 amp TPN MCCB 30 KA Legrand/ Schneider /ABB/L&T sample to be approved before installation.. , 1 SPARE |
| 189 | b63 amp TPN MCCB 36 KA Legrand/ Schneider /ABB/L&T sample to be approved before installation.. |
| 190 | Floor Panels (Ground , First & second) : Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement). 3no @12 cft |
| 191 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. |
| 192 | INCOMING |
| 193 | 100 amp FP MCCB 30 KA , including spreader links,( Adjustable thermal and magnetic release) Legrand /Schneider/L&T/ABB make. |
| 194 | 4 No. of Aluminum Bus Bar of 200 Amp. |
| 195 | Digital meters and phase indicators -1 set. |
| 196 | OUTGOING |
| 197 | 63 amp TP MCB 10 KA Legrand /Schneider/L&T/ABB make. 2 spare |
| 198 | 63 amp DP 10KA MCB |
| 199 | b) space for 12 way MCB's Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysNov 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender