Housing Urban and Rular Development Local Bodies Closing in 6 days TDR #58267674

Tender For Maintenance Of Completed Works (North Zone). S.H : Running, Maintenance, Operation Of Clear Water Pumps, Submersible Pump, Fire Fighting System, 160 Kva D.G. Set, Rescue Of Lift, Fire Alarm & P.A. System, I.E.I., Compound Lighting Etc. At

Issued by Local Bodies · Delhi, Delhi
Tender Value
58.87 Lakhs
Estimated cost
Bid Submission
05 Nov 2026
6 days left
EMD
1.17 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Maintenance Of Completed Works (North Zone). S.H : Running, Maintenance, Operation Of Clear Water Pumps, Submersible Pump, Fire Fighting System, 160 Kva D.G. Set, Rescue Of Lift, Fire Alarm & P.A. System, I.E.I., Compound Lighting Etc. At 216 Hig (Ms) Flats Near T.V. Tower Complex Pit Ura.

BOQ

Name of Work:- Maintenance of completed works (North Zone). S.H : Running, Maintenance, Operation of clear water pumps, submersible pump, fire fighting system, 160 KVA D.G. Set, rescue of lift, Fire Alarm & P.A. System, I.E.I., compound lighting etc. at 216 HIG (MS) flats near T.V. Tower Complex Pit ura.
Sl. No. Item Description
1Operation of clear water pump sets , Firefighting system, D.G. Set, Fire Alarm & P.A. System, I.E.I., compound lighting etc. at 216 HIG (MS) flats near T.V. Tower Complex Pitampura as per inventory of equipment, terms & conditions enclosed herewith.
2Operation of 12 nos. 08 passsenger lifts i/c the rescue of the stuck passenger in case of power/lift failure by deputing 02 nos. operators in 3 shifts each for round the clock ( i.e. 06 operators) as per terms & conditions attached.
3Supplying and Replacenient (from deputed staff) of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade. internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5%), life time (LED Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K /5700°K /6000°K/6500°K (As per ANSI Bin), CM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade 2.00 mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc, as rquired with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 Im/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) along with buyback of old fittings.CRCA Sheet Body (Thickness ≥ 0.50 mm)
4Servicing and preventive maintenance of 160 KVA D.G. set i/c supply & replacement of mobile oil, coolant, air filter, diesel filter, oil filter i/c testing, commissioning etc. complete as required as per engine manufecturer,for B- check.
5Dismentling rewinding and re-assembling of 30 HP 3 Phase 415 volt induction motor, replacement of connection plate i/c varnishing, tapping connection, testing, cartage to and fro etc. complete as required.
6Dismentling rewinding and re-assembling of 20 HP 3 Phase 415 volt induction motor, replacement of connection plate i/c varnishing, tapping connection, testing cartage to and fro etc. complete as required.
7Repairing of 30 HP Kirlosker make centrifugal Pump set i/c S/R of following worn out parts i.e. gland sleeve, neck ring, ball bearing, nut bolt, poacing and cartage to & fro i/c dismantling & reassembling, commissioning at site etc. as required.
8Repairing of 20 HP booster pumjp i/c replacement of following worn out pars i/e. gland sleeve, neck ring, ball bearing, nut bolt, packing and cartage to & fro i/c dismantling & reassembling, commissioning at site etc. as required.
9Repairing of 12.5 HP p/set Kirloskarmake i/c S/R of worn out parts i.e. Impeller, Impeller Nut, Packingkit, Ball bearig, gland bush and gland plate etc.
10Supply and installation of MU-G40 FASD (with wideband coil), ( HSN code 8356) , relay rang 36-60A with 40 HP pump rating starter i/c rebate for dismentaled material, connection & testing etc. complete as reqd.
11Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. a)100 A,36KA,FPMCCB
12Supply and installation of ML3W type , 2 NO+ 2NC Aux. contacts starter i/c rebate for dismentaled material, connection & testing etc. complete as reqd.
13Lifting out of the existing submersible pump set from the exisiting bore well i/c dismentling the pipe line and pump set & submsersible cable with the help of tri post block etc. as required. (About 30 length in bore well 3 mtr. each in bore well).
14Lowering the submersible pump set after repairing the pump set in the exisiting bore well i/c making of connection of pump set and pipe line providing with rubber packing & nut bolts, making of water proof joint of submersible cable, testing commissioning etc. as required (About 30 length in bore well 3 mtr. each bore well).
15Repairing and rewinding of 3 HP submersible pump set i/c replacement/ repairing of Thurst plate, Thrust Bearing, Bearing Bush, Rotor remetaling, turning & balacing and Coupling Sleeve with key reassembling, replacement of Impeller, Difffuser, upper sleeve/bush, Suction guard, shaft dismantling, turning, balancing and reassembling testing testing i/c cartage to & fro etc. as required.
16Supplying, installation, testing and commissioning of 1 HP (0.75 kW), 415 V, 50 Hz, pump set having discharge range (4280-700) LPH & head range (6-55)mtr. including necessary accessories, fittings, cable connections, and all materials and labour required complete as required, i/c rebate on existing sub. pump set.
17Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/PVC conduit as required.a) 3 x 1.5 sq. mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58267674
AUTHORITY Local Bodies
TENDER VALUE 58.87 Lakhs
LAST DATE 05-11-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for Maintenance Of Completed Works (North Zone). S.H : Running, Maintenance, Operation Of Clear Water Pumps, Submersible Pump, Fire Fighting System, 160 Kva D.G. Set, Rescue Of Lift, Fire Alarm & P.A. System, I.E.I., Compound Lighting Etc. At 216 Hig (Ms) Flats Near T.V. Tower Complex Pit Ura.
Basic Detail
Tender No 36/EE/ELD-8/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 29 Oct 2026
Submission Date 05 Nov 2026
Open Date 06 Nov 2026
Finance
Tender Value 58.87 Lakhs
Tender Fee Ref. Documents
EMD 1.17 Lakhs
Exemption Not Available
Document List
482f6699-59e8-4461-b6df-82c6ade4feab.html
BOQ_979652.xls
TenderDoc36.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

482f6699-59e8-4461-b6df-82c6ade4feab.html

xls

BOQ_979652.xls

pdf

TenderDoc36.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender