Housing Urban and Rular Development Local Bodies Closing in 6 days TDR #58266193

Tender For Supply Installation Testing Commissioning Façade Lighting Work At New Chandi Bridge Haridwar

Issued by Local Bodies · Haridwar, Uttarakhand
Tender Value
80.11 Lakhs
Estimated cost
Bid Submission
16 Nov 2026
6 days left
EMD
1.61 Lakhs
Bank guarantee accepted
Document Fee
4956
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Haridwar → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing Commissioning Façade Lighting Work At New Chandi Bridge Haridwar

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 06-Nov-2026 Date extension Date 16-Nov-2026

BOQ

Name of Work:- SUPPLY INSTALLATION TESTING COMMISSIONING FAÇADE LIGHTING WORK AT NEW CHANDI BRIDGE HARIDWAR
Sl. No. Item Description
1LED Linear Profile (AC) Supplying Installation, Testing and Commissioning LED warm white (as per site requirement) Linear Profile / Wall Washerluminaire for Facade lighting with aluminium extruded/ Die Cast housing with inbuilt driver of followingwattage as given below. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°, having the rotation degrees scale shall be provided. Theluminaire shall be IP66 protection also having silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, under voltage, over voltage protection, driver inbuilt surge protection of 4KV and external surge protection (SPD) of 10 KV common mode/differential mode, Driver Efficiency>85%, EMI/EMC as per CISPR-15. There should be options of beam angles of 10/20/30/40/60, asymmetric degree. Luminaire should have efficacy of minimum for 100 lm/W for mono colour options. . The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement.\ Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of - -10°C to +50°C and shall have impact resistance of IK 07. Lifetime of complete luminaire (LED ,Driver , Electrical & control 98 shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) with dully R Number marked and shall be complete with all necessary accessories required for proper working of fixture including connection/inter connection with weather proof ISI Marked copper conductor of minimum size 1.5sqmm connection cables and accessories , Integral male/female water proof connectors of IP68 etc. as required. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer, Rohs Compliance. Wattage per meter ( 50 Watts)
2Supplying Installation, Testing and Commissioning of Circular/ Rectangular/square LED warm white (as per site requirement) Facade Floodlight/ Projector luminaire for facade lighting with Pressure Die-cast aluminium housing, powder-coated finish, with inbuilt driver of following wattage as given below. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°, the scale shall be provided for rotation degrees. The luminaire shall be IP66 protection also having silicon gasket between optical cover & LED chamber to ensure proper IP66protection and impact resistance of IK 07. CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, undervoltage, over voltage protection, driver inbuilt surge protection of 4KV and external surge protection (SPD)of 10 KV common mode/differential mode, Driver Efficiency>85%, EMI/EMC as per CISPR-15. Thereshould be options of beam angles of 10/15/20/25/30/40/45/60 degree. Luminaire should have efficacy of 100 lm/W for mono colour options.. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of -10°C to +50°C. Lifetime ofcomplete luminaire(LED ,Driver , Electrical & controlcircuitry) shall be at least L70:50000 burning hours at50°C. Luminaire shall be conforming to BIS: (IS10322) with dully R Number marked and shall becomplete with all necessary accessories required forproper working of fixture including connection/interconnecion with weather proof ISI Marked copperconductor of minimum size 1.5sqmm connectioncables and accessories, Integral male/female waterproof connectors IP 68 etc. as required.The successful bidder shall submit the following certifications/reportsfor approval before supply of materials: product datasheets, LM79 report from NABL accredited lab,illuminance diagram, polar curve & LM80 report issuedby LED manufacturer, RoHS Compliance. 200 watts
3Supplying and Fixing of IP65 \\"I\\" power connectors having 3/4 pole cable connector, chuck type strain relief, Current rating 20 A rms continuous, Easy and extremely precise locking system \\"Quick Lock\\" High impact materials - long-lasting and reliable etc complete as required.
4Supply and laying of 4.0 sq. mm x 3 core ISI marked, FRLS PVC insulated, single core copper conductor cable in exising conduits with proper connections, glands, etc
5Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.25 mm
6Supply and Laying of one number 4 core X 25 Sq mm Aluminium Armoured PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground or pipe or trench as required including excavation, sand cushioning, protective covering and refilling the trench etc as required.
7Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
8Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
9Supply Installation Testing Comissioning of factory fabricated and wired metal clad dust and vermin proof floor mounting outdoor panel TPN switch board complete. The instrument chamber shall be saprate and shall comprise of Multifunction meter and current transformer etc. The board shall have suitable cappcity electrolytic aluminium bus bars as per IS:8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC /DMC supports with detchable side covers and shall be suitable for extension on the sides .the switches shall be complete with suitable with cable and boxes ,revers entry boxes in case of pedestal type cable socket compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer Incharge The switch board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm cubical type switch board shall be of Cat A, B & B = II only outdoor type with following incomming and outgoings TTA SEC 61439-1 61439-2 61439-3 61439-4 INCOMING MCCB-125Amp TPN-01 Multifunction meter-01 RYB Indicators-01Set Digital control Servo Voltage Stabalizer of 40KVA oil type with voltage range from 260Volt to 480Volt OUTGOING 63 Amp FP MCB- 03 No, 63 Amp DP MCB- 04 No 15Amp Combined Socket-04No Space for company DMX Splitter and Boosters as per specifications
10Sub Panel or JB for power distribution outdoor type- i/c -63A 4P MCB and o/g- 4No. 40A DP MCB
11Supply and Laying of one number 4 core X 75 Sq mm Aluminium Armoured PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground or pipe or trench as required including excavation, sand cushioning, protective covering and refilling the trench etc as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58266193
AUTHORITY Local Bodies
TENDER VALUE 80.11 Lakhs
LAST DATE 16-11-2026
Authority
Authority Name Haridwar Development Authority
Work Description Tender for Supply Installation Testing Commissioning Façade Lighting Work At New Chandi Bridge Haridwar
Basic Detail
Tender No SITC of Fcade Light Work At New Chandi Ghat Bridge Haridwar
Bidding Type Tender
Location
City Haridwar
State Uttarakhand
Key Dates
Publish Date 06 Nov 2026
Submission Date 16 Nov 2026
Open Date 16 Nov 2026
Finance
Tender Value 80.11 Lakhs
Tender Fee 4956
EMD 1.61 Lakhs
Exemption Not Available
Document List
7275b8ec-7d04-4c6e-8f7d-34034f4ef068.html
BOQ_119884.xls
SITC_chandighat_bridge.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 16, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 6 days
Nov 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

7275b8ec-7d04-4c6e-8f7d-34034f4ef068.html

xls

BOQ_119884.xls

pdf

SITC_chandighat_bridge.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender