Power Government Departments Closing in 0 days TDR #58265670

Tender For Supply Installation Testing and Commissioning of Power Transformer And Balance Works 33/11Kv Recieveing Station Manglamata, Sd Kalakote

Issued by Government Departments · Rajouri, Jammu and Kashmir
Tender Value
2.07 Crore
Estimated cost
Bid Submission
04 Nov 2026
0 days left
EMD
4.15 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rajouri → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Power Transformer And Balance Works 33/11Kv Recieveing Station Manglamata, Sd Kalakote

BOQ

Name of Work:- SITC OF POWER TRANSFORMER AND BALANCE WORKS 33/11kV RECIEVEING STATION MANGLAMATA, SD KALAKOTE
Sl. No. Item Description
133 kV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type)
233 kV Isolator without Earthing Blade (36kV,1250A, Outdoor, 3 poles, 25 kA)
333 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ)
430 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less
533 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps, DLMS Compliant with RS-485 port
633 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m
7PIPE STRUCTURESNonimal Bore 200, 5.9 mm Thick
8Galvanised Steel Structures
9Galvanised Nuts & Bolts
1012 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
116 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
122 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
13Lugs, Ferrules etc.
14ACSR Conductor Panther
15T Clamps
16Erection ant testing commissioning of Power Transformer3.15MVA 33/11kV, ONAN, Copper wound, Out-door Type, conventional Power Transformer, Oil Filled with OLTC and all accessories including HT and LT Terminal connections, Gantary and Tertiary Winding.
1712 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
186 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
192 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
20COST FOR 11 kV INDOOR SWITCHGEAR OF 3.15MVA, 33/11 KV SUBSTATION 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Outdoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (1+3)SET
2111kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets)
2211 kV 3- Core XLPE 185 mm² armoured, FRLS
2311 kV 3-Core XLPE 120 mm² armoured, FRLS
2411 kV Heat Shrinkable Cable Termination Kit for incoming Cable11 kV Indoor Heat Shrinkable Cable Termination Kits
2511 kV Outdoor Heat Shrinkable Cable Termination Kits
2611 kV Heat Shrinkable Cable Termination Kit for Outgoing Cable11 kV Indoor Heat Shrinkable Cable Termination Kits
2711 kV Outdoor Heat Shrinkable Cable Termination Kits
2811 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch.
299 Mtr. Long Pole(ST-410 SP33)
3011kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp
31Galvanised iron of sorts
32100 kVA,11/0.433KV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound)
33120 mm² PVC LT Cable 4 Core, armoured, FRLS
34Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole
35Earthing of 100KVA substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm & 50 mm x 6 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
36Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI strip
37MCCB ‐ 200 Amps
38COMMON MISCELLENOUS WORKS IN 33/11kV SUBSTATIONS Chainlink Fencing of 33 kV Yard of Substation by way of Mass Concrete in Foundations and chainlink fencing of 6 ft height
39Compound walling of identified land by way of Mass Concrete in Foundations and 228 mm Brick Wall of 2 M height with Main Gate of Pipes
40RCC CABLE DUCT (0.5x1)sqm with duct covers and angle supports for XLPE Cable from Power Transformer to Incommer
4133/11 kV Power Transformer Foundation
4233 kV Equipment Foundation & Gantry foundation
43Earthing Mat (GI Flat 50 mm x8 mm)
44Earthing Electrode ( 3m long 40mm dia GI pipe) through GI Strip.
4533 kV Yard Concreting
46Yard Lightening 4no. Led on 9mtr poles complete
47RCC Protection wall 60cubicmeter
48COMMON MISCELLANEOUS EQUIPMENTS 33/11kV SUBSTATIONSa). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer container,flame retardant. b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply .
49Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories
50Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories
51Rubber Mat 1mx2m 19mm thick
523 Sand Bucket Fire Extingiusher
53Helmet
54Rubber Gloves for 33 kV level
55Safety Belt
56Safety Shoes
57Earthing rod (set of 3 rods)
5833KV Line Bay 33 KV Vacuum Circuit Breaker (36 KV, 1250A, 26.2 KA, Outdoor type)
5933 KV Current Transfoormer (33 KV, 1ph, Multi Ration Multi Core, Outdoor) (1 No. per ph)
6033 KV C&R Panel alomngwith O/C, E/F and differential relays (IEC61850), Mimic diagram, voltmeter , Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter-5 Amps, DLMS Compliant with RS-485 port.
6133 KV Post Insulator Polymer 36KV, 235KV Impulse, creepage distance 1224m
6233 KV Isolator with Earthing Blade (36KV, 1250A, Outdoor, 3 Poles, 25 KA)
6334 KV Isolator without Earthing Blade (36KV, 1250A, Outdoor, 3 Poles, 25 KA)
64PIPE STRUCTURESNominal Bore 200, 5.9mm Thick
65Galvanised Steel Structures
66Galvanised Nuts & Bolts
67CONTROL CABLES12 Core 2.5 mm Sq. Control Cable Copper Rmoured, 1.1 KV Grade, ISI, FRLS
686 Core 2.5 mm Sq. Control Cable Copper Rmoured, 1.1 KV Grade, ISI, FRLS
692 Core 2.5 mm Sq. Control Cable Copper Rmoured, 1.1 KV Grade, ISI, FRLS
70Lugs, Ferrules etc.
71CONDUCTOR & HARDWARE200sqmm ACSR Conductor Panther
72T-Clamps
73Single Tension Fitting
74Polymeric Composite Disc Insulator 36kv, Lightening Impulse 170kv Postive and 180kv Negative, creepage distance 900mm, min failing load 70Kn
75Earth Wire 7/4 sqmm
76GI Flat for earthing 50x6mm
77COMMON MISCELLENOUS WORKS IN 33/11kV substation line bay33 kV Equipment Foundation & Gantry foundation
78Earthing Mat (GI Flat 50 mm x8 mm)
79Earthing Electrode ( 3m long 40mm dia GI pipe) through GI Strip.
8033 kV Yard Concreting
81Chainlink Fencing of 33 kV Yard of Substation by way of Mass Concrete in Foundations and chainlink fencing of 6 ft height
8211KV Line for O/G feeders (3km)8 Mtr. Long Pole(PCC WL-200Kg , ST-410 SP15)
83GI V cross-arm with top Bracket including clamp
84GI Channel X-arm including clamps and braces
8550 mm² ACSR Conductor
86PG Clamps for 50 mm² ACSR Conductor
8711kV Polymeric composite Pin Insulator 12kV, 5kN, LightingImpulse 75kV Positive and 80kV Negative, creepage distance 320mm
8811kV Polymeric composite Disc Insulator 12kV,min failing load45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
89Galvanized Nuts and Bolts
90Danger Plates with Clamps
91Anti-Climbing Device with Clamps
92Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
93Red Oxide
94Aluminium Paint
95Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
96Aluminium Jointing Sleeves
97Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn- buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
9811 KV Capacitor bank with VCB Panel with complete arrangement for connection with 11 KV incomer panel, Series Reactor, Isolator, RVT, Surge Arrestor, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with Structure, foundation and accessories. 2.4MVAR Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58265670
AUTHORITY Government Departments
TENDER VALUE 2.07 Crore
LAST DATE 04-11-2026
Authority
Authority Name Jammu And Kashmir Power Development Department
Work Description Tender for Supply Installation Testing and Commissioning of Power Transformer And Balance Works 33/11Kv Recieveing Station Manglamata, Sd Kalakote
Basic Detail
Tender No STD-IV/JPDCL/24 OF 2026-27 DATED 12/10/2026
Bidding Type Tender
Location
City Rajouri
State Jammu and Kashmir
Key Dates
Publish Date 29 Oct 2026
Submission Date 04 Nov 2026
Open Date 05 Nov 2026
Finance
Tender Value 2.07 Crore
Tender Fee 3000
EMD 4.15 Lakhs
Exemption Not Available
Document List
688b90de-5c29-415e-9f4e-853cd3d79995.html
BOQ_1117256.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Nov 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

688b90de-5c29-415e-9f4e-853cd3d79995.html

xls

BOQ_1117256.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender