Public Administrative Department Government Departments Closing in 11 days TDR #58265648

Bids Are invited for Iti Measuring Instruments

Issued by Government Departments · Tapi, Gujarat
Tender Value
Ref. Documents
Estimated cost
Bid Submission
13 Nov 2026
11 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tapi → Gujarat
EMD Exemption
Available
Quantity
12

Project Description

Bids Are invited for Wheatstone Bridge Trainer Kit For Iti Electrical Practical Lab - Self-Contained Laboratory Setup For Medium Resistance Measurement 1 Ohm To 1 Megohm. Features 7-Step Ratio Arm P/Q, 4 Or 5-Decade Standard Resistance Arm S, Center-Zero Null Galvanometer 30-0-30 Microampere, Integrated Dc Power Supply 2-9 Volt, Housed In An Insulated Abs Or Wooden Cabinet With 4 Millimeter Safety Terminals. Compliant With Ncvt And Dgt Syllabus. , Analog Moving Coil Dc Voltmeter Range 0-300 Volts - Analog Moving Coil Pmmc Dc Voltmeter, Range 0 To 300 Volt Dc, Class 1.5 Or 1.0 Accuracy. Portable Desktop Inclined Abs Or Bakelite Casing With Knife-Edge Pointer, Mirror Scale, Zero-Adjustment Screw, And 4 Millimeter Safety Banana Binding Posts. Compliant With Ncvt And Dgt Iti Practical Standards. , Analog Moving Coil Multirange Dc Voltmeter 0-15V 0-30V 0-50V 0-75V - Multi-Range Analog Dc Moving Coil Voltmeter Covering 0 To 15 Volt, 0 To 30 Volt, 0 To 50 Volt, And 0 To 75 Volt Dc. Features Multi-Terminal Or Rotary Selection, Class 1.5 Or 1.0 Accuracy, Anti-Parallax Mirror Scale, And Portable Desktop Casing. Compliant With Ncvt And Dgt Syllabus. , Dual Ac Dc Moving Iron Ammeter Range 0-500 Ma - Dual Ac Dc Moving Iron M.I. Milliammeter, Range 0 To 500 Milliampere, Class 1.5 Or 1.0 Accuracy, Operating Frequency 45 To 65 Hertz. Desktop Portable Abs Housing With Zero-Adjust Screw, Knife-Edge Pointer, And Insulated Terminals. Compliant With Ncvt And Dgt Syllabus. , Solid State Single Phase Solar Bidirectional Energy Net Meter 5-30A 240V - Single-Phase 2-Wire Net Metering Static Energy Meter, Ratings 5 To 30 Ampere, 240 Volt Ac, 50 Hertz, Class 1.0 Accuracy. Measures Import Export Net Kilowatt-Hour, Volt, Ampere, Power Factor, Maximum Demand With Multi-Function Lcd Display, Optical Rs-485 Dlms Port, And Anti-Tamper Polycarbonate Enclosure. Compliant With Is 13779 And Is 15959. , Analog Dc Moving Coil Ammeter 0-1 Panel Board Flush Mount Type - Analog Moving Coil Dc Ammeter, Range 0 To 1 Ampere Dc, Class 1.5 Or 1.0 Accuracy. Panel Flush Mounting Type Standard 96X96 Millimeter Or 72X72 Millimeter With Abs Housing, Rear Brass Stud Terminals, Linear Scale, Knife-Edge Pointer, And Zero-Adjust Screw. Compliant With Is 1248 And Ncvt Dgt Syllabus. , Thermal Expansion Hot Wire Ammeter Range 0-15 Amps Ac Dc True Rms - Thermal Expansion Hot Wire Ammeter For True Rms Ac Dc Measurement, Range 0 To 15 Ampere, Class 1.5 Or 2.0 Accuracy. Features Eddy Current Damping, Non-Linear Thermal Scale, Frequency-Independent Operation, And Zero-Setting Adjustment In A Desktop Panel Casing. , Moving Coil Dc Ammeter Range 300A And 60A With External 75Mv Shunt - Moving Coil Dc Ammeter Paired With External Precision Manganin Shunts 75 Millivolt Output Drop. Dual Range 0 To 60 Ampere And 0 To 300 Ampere Dc, Class 1.0 Meter And Class 0.5 Shunt Accuracy. Includes Meter Unit, External Shunts, And 75 Millivolt Potential Leads In Desktop Panel Casing.

BOQ

Sl. No. Item TitleItem Description
1Wheatstone Bridge Trainer Kit for ITI Electrical Practical LabSelf-contained laboratory setup for medium resistance measurement 1 Ohm to 1 Megohm. Features 7-step ratio arm P/Q, 4 or 5-decade standard resistance arm S, center-zero null galvanometer 30-0-30 microampere, integrated DC power supply 2-9 Volt, housed in an insulated ABS or wooden cabinet with 4 millimeter safety terminals. Compliant with NCVT and DGT syllabus.
2Analog Moving Coil DC Voltmeter Range 0-300 VoltsAnalog Moving Coil PMMC DC Voltmeter, Range 0 to 300 Volt DC, Class 1.5 or 1.0 accuracy. Portable desktop inclined ABS or Bakelite casing with knife-edge pointer, mirror scale, zero-adjustment screw, and 4 millimeter safety banana binding posts. Compliant with NCVT and DGT ITI practical standards.
3Analog Moving Coil Multirange DC Voltmeter 0-15V 0-30V 0-50V 0-75VMulti-range Analog DC Moving Coil Voltmeter covering 0 to 15 Volt, 0 to 30 Volt, 0 to 50 Volt, and 0 to 75 Volt DC. Features multi-terminal or rotary selection, Class 1.5 or 1.0 accuracy, anti-parallax mirror scale, and portable desktop casing. Compliant with NCVT and DGT syllabus.
4Dual AC DC Moving Iron Ammeter Range 0-500 mADual AC DC Moving Iron M.I. Milliammeter, Range 0 to 500 milliampere, Class 1.5 or 1.0 accuracy, operating frequency 45 to 65 Hertz. Desktop portable ABS housing with zero-adjust screw, knife-edge pointer, and insulated terminals. Compliant with NCVT and DGT syllabus.
5Solid State Single Phase Solar Bidirectional Energy Net Meter 5-30A 240VSingle-Phase 2-Wire Net Metering Static Energy Meter, Ratings 5 to 30 Ampere, 240 Volt AC, 50 Hertz, Class 1.0 accuracy. Measures Import Export Net kilowatt-hour, Volt, Ampere, Power Factor, Maximum Demand with multi-function LCD display, optical RS-485 DLMS port, and anti-tamper polycarbonate enclosure. Compliant with IS 13779 and IS 15959.
6Analog DC Moving Coil Ammeter 0-1 Amp Panel Board Flush Mount TypeAnalog Moving Coil DC Ammeter, Range 0 to 1 Ampere DC, Class 1.5 or 1.0 accuracy. Panel flush mounting type standard 96x96 millimeter or 72x72 millimeter with ABS housing, rear brass stud terminals, linear scale, knife-edge pointer, and zero-adjust screw. Compliant with IS 1248 and NCVT DGT syllabus.
7Thermal Expansion Hot Wire Ammeter Range 0-15 Amps AC DC True RMSThermal Expansion Hot Wire Ammeter for True RMS AC DC measurement, Range 0 to 15 Ampere, Class 1.5 or 2.0 accuracy. Features eddy current damping, non-linear thermal scale, frequency-independent operation, and zero-setting adjustment in a desktop panel casing.
8Moving Coil DC Ammeter Range 300A and 60A with External 75mV ShuntMoving Coil DC Ammeter paired with External Precision Manganin Shunts 75 millivolt output drop. Dual range 0 to 60 Ampere and 0 to 300 Ampere DC, Class 1.0 meter and Class 0.5 shunt accuracy. Includes meter unit, external shunts, and 75 millivolt potential leads in desktop panel casing.

AI Tender Summary

OUR REF NO 58265648
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 13-11-2026
Authority
Authority Name Department Of Employment And Training
Work Description Bids Are invited for Wheatstone Bridge Trainer Kit For Iti Electrical Practical Lab - Self-Contained Laboratory Setup For Medium Resistance Measurement 1 Ohm To 1 Megohm. Features 7-Step Ratio Arm P/Q, 4 Or 5-Decade Standard Resistance Arm S, Center-Zero Null Galvanometer 30-0-30 Microampere, Integrated Dc Power Supply 2-9 Volt, Housed In An Insulated Abs Or Wooden Cabinet With 4 Millimeter Safety Terminals. Compliant With Ncvt And Dgt Syllabus. , Analog Moving Coil Dc Voltmeter Range 0-300 Volts - Analog Moving Coil Pmmc Dc Voltmeter, Range 0 To 300 Volt Dc, Class 1.5 Or 1.0 Accuracy. Portable Desktop Inclined Abs Or Bakelite Casing With Knife-Edge Pointer, Mirror Scale, Zero-Adjustment Screw, And 4 Millimeter Safety Banana Binding Posts. Compliant With Ncvt And Dgt Iti Practical Standards. , Analog Moving Coil Multirange Dc Voltmeter 0-15V 0-30V 0-50V 0-75V - Multi-Range Analog Dc Moving Coil Voltmeter Covering 0 To 15 Volt, 0 To 30 Volt, 0 To 50 Volt, And 0 To 75 Volt Dc. Features Multi-Terminal Or Rotary Selection, Class 1.5 Or 1.0 Accuracy, Anti-Parallax Mirror Scale, And Portable Desktop Casing. Compliant With Ncvt And Dgt Syllabus. , Dual Ac Dc Moving Iron Ammeter Range 0-500 Ma - Dual Ac Dc Moving Iron M.I. Milliammeter, Range 0 To 500 Milliampere, Class 1.5 Or 1.0 Accuracy, Operating Frequency 45 To 65 Hertz. Desktop Portable Abs Housing With Zero-Adjust Screw, Knife-Edge Pointer, And Insulated Terminals. Compliant With Ncvt And Dgt Syllabus. , Solid State Single Phase Solar Bidirectional Energy Net Meter 5-30A 240V - Single-Phase 2-Wire Net Metering Static Energy Meter, Ratings 5 To 30 Ampere, 240 Volt Ac, 50 Hertz, Class 1.0 Accuracy. Measures Import Export Net Kilowatt-Hour, Volt, Ampere, Power Factor, Maximum Demand With Multi-Function Lcd Display, Optical Rs-485 Dlms Port, And Anti-Tamper Polycarbonate Enclosure. Compliant With Is 13779 And Is 15959. , Analog Dc Moving Coil Ammeter 0-1 Panel Board Flush Mount Type - Analog Moving Coil Dc Ammeter, Range 0 To 1 Ampere Dc, Class 1.5 Or 1.0 Accuracy. Panel Flush Mounting Type Standard 96X96 Millimeter Or 72X72 Millimeter With Abs Housing, Rear Brass Stud Terminals, Linear Scale, Knife-Edge Pointer, And Zero-Adjust Screw. Compliant With Is 1248 And Ncvt Dgt Syllabus. , Thermal Expansion Hot Wire Ammeter Range 0-15 Amps Ac Dc True Rms - Thermal Expansion Hot Wire Ammeter For True Rms Ac Dc Measurement, Range 0 To 15 Ampere, Class 1.5 Or 2.0 Accuracy. Features Eddy Current Damping, Non-Linear Thermal Scale, Frequency-Independent Operation, And Zero-Setting Adjustment In A Desktop Panel Casing. , Moving Coil Dc Ammeter Range 300A And 60A With External 75Mv Shunt - Moving Coil Dc Ammeter Paired With External Precision Manganin Shunts 75 Millivolt Output Drop. Dual Range 0 To 60 Ampere And 0 To 300 Ampere Dc, Class 1.0 Meter And Class 0.5 Shunt Accuracy. Includes Meter Unit, External Shunts, And 75 Millivolt Potential Leads In Desktop Panel Casing.
Basic Detail
Tender No GEM/2026/B/8154908
Bidding Type Tender
Location
City Tapi
State Gujarat
Key Dates
Publish Date 29 Oct 2026
Submission Date 13 Nov 2026
Open Date 14 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Available
Document List
750d34d0-747a-4054-9395-31912190e9fb.pdf
item_specification_document_meter_boq_2026-10-13-15-25-15_3c81cf8cf028d11cdf4295ed27ad87eb.pdf
10028541_Boq_1.xlsx

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Nov 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
pdf

750d34d0-747a-4054-9395-31912190e9fb.pdf

pdf

item_specification_document_meter_boq_2026-10-13-15-25-15_3c81cf8cf028d11cdf4295ed27ad87eb.pdf

xlsx

10028541_Boq_1.xlsx

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender