Housing Urban and Rular Development Government Departments Closing in 13 days TDR #58265136

Tender For Construction Of Marathwada Mukti Sangram Smarak And Immersive Technology At Taluka And District Chh.Sambhajinagar

Issued by Government Departments · Aurangabad, Maharashtra
Tender Value
75.88 Crore
Estimated cost
Bid Submission
13 Nov 2026
13 days left
EMD
37.95 Lakhs
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Aurangabad → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Marathwada Mukti Sangram Smarak And Immersive Technology At Taluka And District Chh.Sambhajinagar

BOQ

Name of Work:- CONSTRUCTION OF MARATHWADA MUKTI SANGRAM SMARAK AND IMMERSIVE TECHNOLOGY AT TALUKA AND DISTRICT CHH.SAMBHAJINAGAR
Sl. No. Item Description
1PART A - WORK PORTION
2Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
3Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means
4Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical Means
5Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By MechanicalMeans
6Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
7Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper.
8Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per squaremetre of surface area covering ten years guarantee on bond paper.
9Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
10Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings ofR.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
11Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
12(A)Upto Level 12.00
13(B)From 12.00 to 18.00 m
14( C)From 18.00 to 24.00 m
15(D)From 24.00 to 26.400 m
16(E ) From 26.400 m to 32.400
17(F)From 32.400 m to 38.400 m
18(G)From 38.400 m to 44.400
19(H)From 44.400 m to 50.400
20(I)From 50.400 m to 56.400
21(J)From 56.400 m to 62.400
22(K) Above 62.400 m
23Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap /granite/quartzite/ gneiss metal for R.C.C / Pretensioned concrete. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
24(A)Upto Level 12.00
25(B)From 12.00 to 18.00 m
26( C)From 18.00 to 24.00 m
27(D)From 24.00 to 26.400 m
28(E ) From 26.400 m to 32.400
29(F)From 32.400 m to 38.400 m
30(G)From 38.400 m to 44.400
31(H)From 44.400 m to 50.400
32(I)From 50.400 m to 56.400
33(J)From 56.400 m to 62.400
34(K) Above 62.400 m
35Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/ granite / quartzite/ gneiss metal for R.C.C /pre stressed concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
36(A)Upto Level 12.00
37(B)From 12.00 to 18.00 m
38( C)From 18.00 to 24.00 m
39(D)From 24.00 to 26.400 m
40(E ) From 26.400 m to 32.400
41(F)From 32.400 m to 38.400 m
42(G)From 38.400 m to 44.400
43(H)From 44.400 m to 50.400
44(I)From 50.400 m to 56.400
45(J)From 56.400 m to 62.400
46(K) Above 62.400 m
47Providing and laying Cast in situ/Ready Mixcement concrete M-40 of trap/ granite/ quartzite/ gneiss metal forR.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
48(A)Upto Level 12.00
49(B)From 12.00 to 18.00 m
50( C)From 18.00 to 24.00 m
51(D)From 24.00 to 26.400 m
52(E ) From 26.400 m to 32.400
53(F)From 32.400 m to 38.400 m
54(G)From 38.400 m to 44.400
55(H)From 44.400 m to 50.400
56Providing and laying in situ / ready mix M 40 RCC of trap/ granite/ quartzite/ gneiss metal for RCC work of R.C.C Wall (shear), ballast walls, kerbs and box returns including scaffolding, compaction, formwork finishing and curing etc. complete. (excluding reinforcement, with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer with fine agreegates of required specifications ( VSI sand finely washed etc
57(A)Upto Level 12.00
58(B)From 12.00 to 18.00 m
59( C)From 18.00 to 24.00 m
60(D)From 24.00 to 26.400 m
61(E ) From 26.400 m to 32.400
62(F)From 32.400 m to 38.400 m
63(G)From 38.400 m to 44.400
64(H)From 44.400 m to 50.400
65(I)From 50.400 m to 56.400
66(J)From 56.400 m to 62.400
67Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap /granite / gneiss/ quartzite metal for R.C.C. arches with skew backs as per detailed design and drawings or as directed including steel centering, plywood/steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement, including cover block). Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed) With fine aggregate (Crushed sand VSI Grade)
68(A)Upto Level 12.00
69(K) Above 62.400 m
70Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
71(A)Upto Level 12.00
72(B)From 12.00 to 18.00 m
73( C)From 18.00 to 24.00 m
74(D)From 24.00 to 26.400 m
75(E ) From 26.400 m to 32.400
76(F)From 32.400 m to 38.400 m
77(G)From 38.400 m to 44.400
78(H)From 44.400 m to 50.400
79(I)From 50.400 m to 56.400
80Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade)
81(A)Upto Level 12.00
82(J)From 56.400 m to 62.400
83Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters forR.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
84(A)Upto Level 12.00
85(B)From 12.00 to 18.00 m
86( C)From 18.00 to 24.00 m
87(D)From 24.00 to 26.400 m
88(E ) From 26.400 m to 32.400
89(F)From 32.400 m to 38.400 m
90(G)From 38.400 m to 44.400 m
91(H)From 44.400 m to 50.400 m
92(I)From 50.400 m to 56.400 m
93(J)From 56.400 m to 62.400 m
94(K) Above 62.400 m
95Providing and fixing in position to the exact profile and prestressing the high tensile strands to specified ultimate strength, standard end anchorages, cable ducts, grouting ducts after prestressing and bearing plates with wedges as per detailed drawings including necessary plant and machinery for prestressing etc. complete.
96(A)Upto Level 12.00
97(B)From 12.00 to 18.00 m
98( C)From 18.00 to 24.00 m
99(D)From 24.00 to 26.400 m
100(E ) From 26.400 m to 32.400
101(F)From 32.400 m to 38.400 m
102(G)From 38.400 m to 44.400 m
103(H)From 44.400 m to 50.400 m
104(I)From 50.400 m to 56.400 m
105(J)From 56.400 m to 62.400 m
106(K) Above 62.400 m
107Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layersincluding watering and compacting etc. complete.
108Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc.complete.
109Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thickincluding hand packing and compacting etc. complete.
110Providing,erecting and fixing double extra steel stagging/scaffolding system (Cup lock type/H Frame Type OR Any other Suitable Type) for casting of the Slab and Beams and other actiivity like brick work,plaster all construction activity for covering additional normal Floor Heigth beyond 3.6 m (Floor to Floor) placed and erected as per approved Centering Design horizontal & vertical tubes joint with cup & lock system/Welded etc with M.S. Tubes/Channesl/Joist ,M.S. clamps The scaffolding/Stagging system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in- charge. Note:- The actual erected cubical Area of the Stagging System shall be measured for payment purpose after deducting regular Floor Heigth of 3.6 M . (2) The payment will be made once only for execution of all items for such works.
111(A)Upto Level 12.00
112(B)From 12.00 to 18.00 m
113( C)From 18.00 to 24.00 m
114(E ) From 26.400 m to 32.400
115(F)From 32.400 m to 38.400 m
116(G)From 38.400 m to 44.400 m
117(H)From 44.400 m to 50.400 m
118(I)From 50.400 m to 56.400 m
119(J)From 56.400 m to 62.400 m
120(K) Above 62.400 m
121Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.
122Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering andscaffolding etc. Complete
123(A) Upto Level 12.00 (First Slab)
124(B)From 12.00 -18.00 m (Second Slab)
125(C)Above 18.00 -24.00 m (Third Slab)
126(D)Above 24.00 m to 26.400 (Fourth Slab)
127(E)Above 26.400 m to 32.400 (Fifth Slab)
128(F)Above 32.400 to 38.400 m (Sixth Slab)
129(G)Above 38.40 to 44.40 m (Seventh Slab)
130(H)Above 44.40 to 50.40 m (Eigth Slab)
131(I)Above 50.40 to 56.4 0 m (Nineth Slab)
132(J)From 56.40 to 62.40 m (Tenth Slab)
133Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding,racking out joints and watering etc. complete.
134(B)From 12.00 -18.00 m (Second Slab)
135(C)Above 18.00 -24.00 m (Third Slab)
136(E)Above 26.400 m to 32.400 (Fifth Slab)
137(F)Above 32.400 to 38.400 m (Sixth Slab)
138(G)Above 38.40 to 44.40 m (Seventh Slab)
139(H)Above 44.40 to 50.40 m (Eigth Slab)
140(I)Above 50.40 to 56.4 0 m (Nineth Slab)
141(J)From 56.40 to 62.40 m (Tenth Slab)
142Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/B.B.masonry and or tying by binding wire etc. complete.
143(A) Upto Level 12.00 (First Slab)
144(B)From 12.00 -18.00 m (Second Slab)
145(C)Above 18.00 -24.00 m (Third Slab)
146(D)Above 24.00 m to 26.400 (Fourth Slab)
147(E)Above 26.400 m to 32.400 (Fifth Slab)
148(F)Above 32.400 to 38.400 m (Sixth Slab)
149(G)Above 38.40 to 44.40 m (Seventh Slab)
150(H)Above 44.40 to 50.40 m (Eigth Slab)
151(I)Above 50.40 to 56.4 0 m (Nineth Slab)
152(J)From 56.40 to 62.40 m (Tenth Slab)
153Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
154(D)Above 24.00 m to 26.400 (Fourth Slab)
155Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc.complete.
156(A) Upto Level 12.00 (First Slab)
157(B)From 12.00 -18.00 m (Second Slab)
158(C)Above 18.00 -24.00 m (Third Slab)
159(D)Above 24.00 m to 26.400 (Fourth Slab)
160(E)Above 26.400 m to 32.400 (Fifth Slab)
161(F)Above 32.400 to 38.400 m (Sixth Slab)
162(G)Above 38.40 to 44.40 m (Seventh Slab)
163(H)Above 44.40 to 50.40 m (Eigth Slab)
164(I)Above 50.40 to 56.4 0 m (Nineth Slab)
165(J)From 56.40 to 62.40 m (Tenth Slab)
166Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material) in 7 to 10 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete.
167(A) Upto Level 12.00 (First Slab)
168(B)From 12.00 -18.00 m (Second Slab)
169(C)Above 18.00 -24.00 m (Third Slab)
170(D)Above 24.00 m to 26.400 (Fourth Slab)
171(E)Above 26.400 m to 32.400 (Fifth Slab)
172(F)Above 32.400 to 38.400 m (Sixth Slab)
173(G)Above 38.40 to 44.40 m (Seventh Slab)
174(H)Above 44.40 to 50.40 m (Eigth Slab)
175(I)Above 50.40 to 56.4 0 m (Nineth Slab)
176(J)From 56.40 to 62.40 m (Tenth Slab)
177Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
178(A) Upto Level 12.00 (First Slab)
179(B)From 12.00 -18.00 m (Second Slab)
180(C)Above 18.00 -24.00 m (Third Slab)
181(D)Above 24.00 m to 26.400 (Fourth Slab)
182(E)Above 26.400 m to 32.400 (Fifth Slab)
183(F)Above 32.400 to 38.400 m (Sixth Slab)
184(G)Above 38.40 to 44.40 m (Seventh Slab)
185(H)Above 44.40 to 50.40 m (Eigth Slab)
186(I)Above 50.40 to 56.4 0 m (Nineth Slab)
187(J)From 56.40 to 62.40 m (Tenth Slab)
188(K)Above 62.40 m
189Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete.
190(A) Upto Level 12.00 (First Slab)
191(B)From 12.00 -18.00 m (Second Slab)
192(C)Above 18.00 -24.00 m (Third Slab)
193(D)Above 24.00 m to 26.400 (Fourth Slab)
194(E)Above 26.400 m to 32.400 (Fifth Slab)
195(F)Above 32.400 to 38.400 m (Sixth Slab)
196(G)Above 38.40 to 44.40 m (Seventh Slab)
197(H)Above 44.40 to 50.40 m (Eigth Slab)
198(I)Above 50.40 to 56.4 0 m (Nineth Slab)
199Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface,scaffolding etc. complete.
200(A) Upto Level 12.00 (First Slab)
201(B)From 12.00 -18.00 m (Second Slab)
202(C)Above 18.00 -24.00 m (Third Slab)
203(D)Above 24.00 m to 26.400 (Fourth Slab)
204(E)Above 26.400 m to 32.400 (Fifth Slab)
205(F)Above 32.400 to 38.400 m (Sixth Slab)
206(G)Above 38.40 to 44.40 m (Seventh Slab)
207(H)Above 44.40 to 50.40 m (Eigth Slab)
208(I)Above 50.40 to 56.4 0 m (Nineth Slab)
209(J)From 56.40 to 62.40 m (Tenth Slab)
210Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete.
211(A) Upto Level 12.00 (First Slab)
212(I)Above 50.40 to 56.4 0 m (Nineth Slab)
213(J)From 56.40 to 62.40 m (Tenth Slab)
214Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curingetc. complete.
215(A) Upto Level 12.00 (First Slab)
216(B)From 12.00 -18.00 m (Second Slab)
217(C)Above 18.00 -24.00 m (Third Slab)
218(D)Above 24.00 m to 26.400 (Fourth Slab)
219(E)Above 26.400 m to 32.400 (Fifth Slab)
220(F)Above 32.400 to 38.400 m (Sixth Slab)
221(G)Above 38.40 to 44.40 m (Seventh Slab)
222(H)Above 44.40 to 50.40 m (Eigth Slab)
223(I)Above 50.40 to 56.4 0 m (Nineth Slab)
224Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court feestamp paper of Rs.500/- including ponding test etc. complete.
225(B)From 12.00 -18.00 m (Second Slab)
226(C)Above 18.00 -24.00 m (Third Slab)
227(E)Above 26.400 m to 32.400 (Fifth Slab)
228(F)Above 32.400 to 38.400 m (Sixth Slab)
229(G)Above 38.40 to 44.40 m (Seventh Slab)
230(H)Above 44.40 to 50.40 m (Eigth Slab)
231(I)Above 50.40 to 56.4 0 m (Nineth Slab)
232(J)From 56.40 to 62.40 m (Tenth Slab)
233Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc.complete.
234(B)From 12.00 -18.00 m (Second Slab)
235(C)Above 18.00 -24.00 m (Third Slab)
236(E)Above 26.400 m to 32.400 (Fifth Slab)
237(F)Above 32.400 to 38.400 m (Sixth Slab)
238(G)Above 38.40 to 44.40 m (Seventh Slab)
239(H)Above 44.40 to 50.40 m (Eigth Slab)
240(I)Above 50.40 to 56.4 0 m (Nineth Slab)
241(J)From 56.40 to 62.40 m (Tenth Slab)
242Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.
243(J)From 56.40 to 62.40 m (Tenth Slab)
244(K)Above 62.40 m
245Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) (As directed by Engineer in Charge) At Second Floor Level
246(B)From 12.00 -18.00 m (Second Slab)
247(C)Above 18.00 -24.00 m (Third Slab)
248(E)Above 26.400 m to 32.400 (Fifth Slab)
249(F)Above 32.400 to 38.400 m (Sixth Slab)
250(G)Above 38.40 to 44.40 m (Seventh Slab)
251(H)Above 44.40 to 50.40 m (Eigth Slab)
252(I)Above 50.40 to 56.4 0 m (Nineth Slab)
253(J)From 56.40 to 62.40 m (Tenth Slab)
254Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oilpainting, etc. complete
255(A) Upto Level 12.00 (First Slab)
256Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc,complete) frame size 60 mm x 100 mm . At Second Floor Level
257(K)Above 62.40 m
258Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.
259(A) Upto Level 12.00 (First Slab)
260(B)From 12.00 -18.00 m (Second Slab)
261(C)Above 18.00 -24.00 m (Third Slab)
262(D)Above 24.00 m to 26.400 (Fourth Slab)
263(E)Above 26.400 m to 32.400 (Fifth Slab)
264(F)Above 32.400 to 38.400 m (Sixth Slab)
265(G)Above 38.40 to 44.40 m (Seventh Slab)
266(H)Above 44.40 to 50.40 m (Eigth Slab)
267(I)Above 50.40 to 56.4 0 m (Nineth Slab)
268(J)From 56.40 to 62.40 m (Tenth Slab)
269Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the woodwork with oil painting 3 coats complete
270(A) Upto Level 12.00 (First Slab)
271(B)From 12.00 -18.00 m (Second Slab)
272(C)Above 18.00 -24.00 m (Third Slab)
273(D)Above 24.00 m to 26.400 (Fourth Slab)
274(E)Above 26.400 m to 32.400 (Fifth Slab)
275(F)Above 32.400 to 38.400 m (Sixth Slab)
276(G)Above 38.40 to 44.40 m (Seventh Slab)
277(H)Above 44.40 to 50.40 m (Eigth Slab)
278(I)Above 50.40 to 56.4 0 m (Nineth Slab)
279(J)From 56.40 to 62.40 m (Tenth Slab)
280Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
281(B)From 12.00 -18.00 m (Second Slab)
282(C)Above 18.00 -24.00 m (Third Slab)
283(E)Above 26.400 m to 32.400 (Fifth Slab)
284Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC 'C' channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ; and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gapinsert for the rail and bottom rail. Door to be fixed to frames with 3 nos M.S.powder coated but hinges of
285(B)From 12.00 -18.00 m (Second Slab)
286(C)Above 18.00 -24.00 m (Third Slab)
287(E)Above 26.400 m to 32.400 (Fifth Slab)
288(F)Above 32.400 to 38.400 m (Sixth Slab)
289(G)Above 38.40 to 44.40 m (Seventh Slab)
290(H)Above 44.40 to 50.40 m (Eigth Slab)
291(I)Above 50.40 to 56.4 0 m (Nineth Slab)
292(J)From 56.40 to 62.40 m (Tenth Slab)
293Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAll corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. 3 Track 3 / 6 Sash (Big Series) window frame of size 122 x 54 mm & Sash of size 64 x 47 mm
294(A) Upto Level 12.00 (First Slab)
295(B)From 12.00 -18.00 m (Second Slab)
296(C)Above 18.00 -24.00 m (Third Slab)
297(D)Above 24.00 m to 26.400 (Fourth Slab)
298(E)Above 26.400 m to 32.400 (Fifth Slab)
299(F)Above 32.400 to 38.400 m (Sixth Slab)
300(G)Above 38.40 to 44.40 m (Seventh Slab)
301(H)Above 44.40 to 50.40 m (Eigth Slab)
302(I)Above 50.40 to 56.4 0 m (Nineth Slab)
303(J)From 56.40 to 62.40 m (Tenth Slab)
304Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.
305(B)From 12.00 -18.00 m (Second Slab)
306(C)Above 18.00 -24.00 m (Third Slab)
307(E)Above 26.400 m to 32.400 (Fifth Slab)
308(F)Above 32.400 to 38.400 m (Sixth Slab)
309(G)Above 38.40 to 44.40 m (Seventh Slab)
310(H)Above 44.40 to 50.40 m (Eigth Slab)
311(I)Above 50.40 to 56.4 0 m (Nineth Slab)
312(J)From 56.40 to 62.40 m (Tenth Slab)
313Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and twocoats of oil painting complete.
314(A) Upto Level 12.00 (First Slab)
315(B)From 12.00 -18.00 m (Second Slab)
316(C)Above 18.00 -24.00 m (Third Slab)
317(D)Above 24.00 m to 26.400 (Fourth Slab)
318(E)Above 26.400 m to 32.400 (Fifth Slab)
319(F)Above 32.400 to 38.400 m (Sixth Slab)
320(G)Above 38.40 to 44.40 m (Seventh Slab)
321(H)Above 44.40 to 50.40 m (Eigth Slab)
322(I)Above 50.40 to 56.4 0 m (Nineth Slab)
323(J)From 56.40 to 62.40 m (Tenth Slab)
324Providing and fixing M.S. grill door 24 Kilogram/Square Metre of various size as per detailed drawingswithout hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc
325(J)From 56.40 to 62.40 m (Tenth Slab)
326Providing and fixing mild steel grill railing 20 Kilogram/sq.m with teak wood hand rail of size 75mm x 60 mm.and sill of 75mm.x 25 mm.and newel posts for staircases, including fabricating, fix-tures, erecting, painting the grill work with one coat of anti-corrosive paint and two coats of oil painting with approved colour and polishing the sill, hand rail and the newel post with french polish.
327(A) Upto Level 12.00 (First Slab)
328(B)From 12.00 -18.00 m (Second Slab)
329(C)Above 18.00 -24.00 m (Third Slab)
330(D)Above 24.00 m to 26.400 (Fourth Slab)
331(E)Above 26.400 m to 32.400 (Fifth Slab)
332(F)Above 32.400 to 38.400 m (Sixth Slab)
333(G)Above 38.40 to 44.40 m (Seventh Slab)
334(H)Above 44.40 to 50.40 m (Eigth Slab)
335(I)Above 50.40 to 56.4 0 m (Nineth Slab)
336(J)From 56.40 to 62.40 m (Tenth Slab)
337Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessarybefore use)
338(A) Upto Level 12.00 (First Slab)
339(B)From 12.00 -18.00 m (Second Slab)
340(C)Above 18.00 -24.00 m (Third Slab)
341(D)Above 24.00 m to 26.400 (Fourth Slab)
342(E)Above 26.400 m to 32.400 (Fifth Slab)
343(F)Above 32.400 to 38.400 m (Sixth Slab)
344(G)Above 38.40 to 44.40 m (Seventh Slab)
345(H)Above 44.40 to 50.40 m (Eigth Slab)
346(I)Above 50.40 to 56.4 0 m (Nineth Slab)
347(J)From 56.40 to 62.40 m (Tenth Slab)
348Providing and fixing 40mm diameter and 1.5 mm thick Stainless steel hand railing in S.S.304 Gradeincluding fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete
349(A) Upto Level 12.00 (First Slab)
350(B)From 12.00 -18.00 m (Second Slab)
351(C)Above 18.00 -24.00 m (Third Slab)
352(D)Above 24.00 m to 26.400 (Fourth Slab)
353(E)Above 26.400 m to 32.400 (Fifth Slab)
354(F)Above 32.400 to 38.400 m (Sixth Slab)
355(G)Above 38.40 to 44.40 m (Seventh Slab)
356(H)Above 44.40 to 50.40 m (Eigth Slab)
357(I)Above 50.40 to 56.4 0 m (Nineth Slab)
358(J)From 56.40 to 62.40 m (Tenth Slab)
359Providing and laying handcut polished Kotah Stone flooring 25mm to 30mm thick and 30cm wide in plain/diamond pattern on a bed of 1:6 C.M. including cement float, filling joints with neat cement slurry,curing, polishing and cleaning etc. complete.
360(D)Above 24.00 m to 26.400 (Fourth Slab)
361Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning,washing etc. complete. For Flooring
362(D)Above 24.00 m to 26.400 (Fourth Slab)
363Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
364(A) Upto Level 12.00 (First Slab)
365(B)From 12.00 -18.00 m (Second Slab)
366(C)Above 18.00 -24.00 m (Third Slab)
367(D)Above 24.00 m to 26.400 (Fourth Slab)
368(E)Above 26.400 m to 32.400 (Fifth Slab)
369(F)Above 32.400 to 38.400 m (Sixth Slab)
370(G)Above 38.40 to 44.40 m (Seventh Slab)
371(H)Above 44.40 to 50.40 m (Eigth Slab)
372(I)Above 50.40 to 56.4 0 m (Nineth Slab)
373(J)From 56.40 to 62.40 m (Tenth Slab)
374Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
375(A) Upto Level 12.00 (First Slab)
376(B)From 12.00 -18.00 m (Second Slab)
377(C)Above 18.00 -24.00 m (Third Slab)
378(D)Above 24.00 m to 26.400 (Fourth Slab)
379(E)Above 26.400 m to 32.400 (Fifth Slab)
380(F)Above 32.400 to 38.400 m (Sixth Slab)
381(G)Above 38.40 to 44.40 m (Seventh Slab)
382(H)Above 44.40 to 50.40 m (Eigth Slab)
383(I)Above 50.40 to 56.4 0 m (Nineth Slab)
384(J)From 56.40 to 62.40 m (Tenth Slab)
385Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
386(B)From 12.00 -18.00 m (Second Slab)
387(C)Above 18.00 -24.00 m (Third Slab)
388(E)Above 26.400 m to 32.400 (Fifth Slab)
389(F)Above 32.400 to 38.400 m (Sixth Slab)
390(G)Above 38.40 to 44.40 m (Seventh Slab)
391(H)Above 44.40 to 50.40 m (Eigth Slab)
392(I)Above 50.40 to 56.4 0 m (Nineth Slab)
393(J)From 56.40 to 62.40 m (Tenth Slab)
394Providing and laying ceramic tiles of having size 30 cm. x 30 cm. and confirming to correspondingI.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
395(B)From 12.00 -18.00 m (Second Slab)
396(C)Above 18.00 -24.00 m (Third Slab)
397(E)Above 26.400 m to 32.400 (Fifth Slab)
398(F)Above 32.400 to 38.400 m (Sixth Slab)
399(G)Above 38.40 to 44.40 m (Seventh Slab)
400(H)Above 44.40 to 50.40 m (Eigth Slab)
401(I)Above 50.40 to 56.4 0 m (Nineth Slab)
402(J)From 56.40 to 62.40 m (Tenth Slab)
403Providing and laying Vitrified MATT finish having decorative type of Specified Plan size of 8 to 10 millimeter thicknessof approved make shade and pattern for flooring in in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.(Double Charged)
404(A) Upto Level 12.00 (First Slab)
405(B)From 12.00 -18.00 m (Second Slab)
406(C)Above 18.00 -24.00 m (Third Slab)
407(E)Above 26.400 m to 32.400 (Fifth Slab)
408(F)Above 32.400 to 38.400 m (Sixth Slab)
409(G)Above 38.40 to 44.40 m (Seventh Slab)
410(H)Above 44.40 to 50.40 m (Eigth Slab)
411(I)Above 50.40 to 56.4 0 m (Nineth Slab)
412(J)From 56.40 to 62.40 m (Tenth Slab)
413Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.
414(A) Upto Level 12.00 (First Slab)
415(B)From 12.00 -18.00 m (Second Slab)
416(C)Above 18.00 -24.00 m (Third Slab)
417(E)Above 26.400 m to 32.400 (Fifth Slab)
418(F)Above 32.400 to 38.400 m (Sixth Slab)
419(G)Above 38.40 to 44.40 m (Seventh Slab)
420(H)Above 44.40 to 50.40 m (Eigth Slab)
421(I)Above 50.40 to 56.4 0 m (Nineth Slab)
422(J)From 56.40 to 62.40 m (Tenth Slab)
423Providing and laying vitrified mirror / glossy finish tiles of Specified Plan size of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float,filling joints, curing and clearing etc. complete
424(A) Upto Level 12.00 (First Slab)
425(B)From 12.00 -18.00 m (Second Slab)
426(C)Above 18.00 -24.00 m (Third Slab)
427(D)Above 24.00 m to 26.400 (Fourth Slab)
428(E)Above 26.400 m to 32.400 (Fifth Slab)
429(F)Above 32.400 to 38.400 m (Sixth Slab)
430(G)Above 38.40 to 44.40 m (Seventh Slab)
431(H)Above 44.40 to 50.40 m (Eigth Slab)
432(I)Above 50.40 to 56.4 0 m (Nineth Slab)
433(J)From 56.40 to 62.40 m (Tenth Slab)
434Providing and laying vitrified rustic matt stone finish tiles having specified plan size 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float,filling joints, curing and cleaning etc. complete. (Double Charged)
435(A) Upto Level 12.00 (First Slab)
436(B)From 12.00 -18.00 m (Second Slab)
437(C)Above 18.00 -24.00 m (Third Slab)
438(E)Above 26.400 m to 32.400 (Fifth Slab)
439(F)Above 32.400 to 38.400 m (Sixth Slab)
440(G)Above 38.40 to 44.40 m (Seventh Slab)
441(H)Above 44.40 to 50.40 m (Eigth Slab)
442(I)Above 50.40 to 56.4 0 m (Nineth Slab)
443(J)From 56.40 to 62.40 m (Tenth Slab)
444Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edgesetc. complete . Both side polish
445(A) Upto Level 12.00 (First Slab)
446(B)From 12.00 -18.00 m (Second Slab)
447(C)Above 18.00 -24.00 m (Third Slab)
448(E)Above 26.400 m to 32.400 (Fifth Slab)
449(F)Above 32.400 to 38.400 m (Sixth Slab)
450(G)Above 38.40 to 44.40 m (Seventh Slab)
451(H)Above 44.40 to 50.40 m (Eigth Slab)
452(I)Above 50.40 to 56.4 0 m (Nineth Slab)
453(J)From 56.40 to 62.40 m (Tenth Slab)
454Providing and fixing Modular false ceiling of 600 x 600 mm center to center and 13 mm thick square mineral fiber board to be fixed on frame work of alluminium sections for suspended false ceiling consisting of alluminium T 2‖x1 ½‖ (50 mm x 40 mm) weighing 0.39 Kilogram/m at 60 cms center center and fixed with ½‖ x ½‖ (15 x 15 mm) flanges weighing0.19 Kilogram/m suspended on 6 mm dia mild steel rod weighing 0.22 Kilogram/m, fixed on wall and beams including rounding of the edges with alluinium T of 2‖ x 1 ½‖ (50 mm x 40 mm) weighing 0.39 Kilogram/m etc. (all alluminium sections shall be anodized) including all labour, material, lifts etc. complete.
455(A) Upto Level 12.00 (First Slab)
456(B)From 12.00 -18.00 m (Second Slab)
457(C)Above 18.00 -24.00 m (Third Slab)
458(D)Above 24.00 m to 26.400 (Fourth Slab)
459(E)Above 26.400 m to 32.400 (Fifth Slab)
460(F)Above 32.400 to 38.400 m (Sixth Slab)
461(G)Above 38.40 to 44.40 m (Seventh Slab)
462(H)Above 44.40 to 50.40 m (Eigth Slab)
463(I)Above 50.40 to 56.4 0 m (Nineth Slab)
464(J)From 56.40 to 62.40 m (Tenth Slab)
465Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete.
466(B)From 12.00 -18.00 m (Second Slab)
467(C)Above 18.00 -24.00 m (Third Slab)
468(E)Above 26.400 m to 32.400 (Fifth Slab)
469(F)Above 32.400 to 38.400 m (Sixth Slab)
470(G)Above 38.40 to 44.40 m (Seventh Slab)
471(H)Above 44.40 to 50.40 m (Eigth Slab)
472(I)Above 50.40 to 56.4 0 m (Nineth Slab)
473(J)From 56.40 to 62.40 m (Tenth Slab)
474Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
475(A) Upto Level 12.00 (First Slab)
476(B)From 12.00 -18.00 m (Second Slab)
477(C)Above 18.00 -24.00 m (Third Slab)
478(D)Above 24.00 m to 26.400 (Fourth Slab)
479(E)Above 26.400 m to 32.400 (Fifth Slab)
480(F)Above 32.400 to 38.400 m (Sixth Slab)
481(G)Above 38.40 to 44.40 m (Seventh Slab)
482(H)Above 44.40 to 50.40 m (Eigth Slab)
483(I)Above 50.40 to 56.4 0 m (Nineth Slab)
484(J)From 56.40 to 62.40 m (Tenth Slab)
485Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
486(A) Upto Level 12.00 (First Slab)
487(B)From 12.00 -18.00 m (Second Slab)
488(C)Above 18.00 -24.00 m (Third Slab)
489(D)Above 24.00 m to 26.400 (Fourth Slab)
490(E)Above 26.400 m to 32.400 (Fifth Slab)
491(F)Above 32.400 to 38.400 m (Sixth Slab)
492(G)Above 38.40 to 44.40 m (Seventh Slab)
493(H)Above 44.40 to 50.40 m (Eigth Slab)
494(I)Above 50.40 to 56.4 0 m (Nineth Slab)
495(J)From 56.40 to 62.40 m (Tenth Slab)
496Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
497(A) Upto Level 12.00 (First Slab)
498(B)From 12.00 -18.00 m (Second Slab)
499(C)Above 18.00 -24.00 m (Third Slab)
500(D)Above 24.00 m to 26.400 (Fourth Slab)
501(E)Above 26.400 m to 32.400 (Fifth Slab)
502(F)Above 32.400 to 38.400 m (Sixth Slab)
503(G)Above 38.40 to 44.40 m (Seventh Slab)
504(H)Above 44.40 to 50.40 m (Eigth Slab)
505(I)Above 50.40 to 56.4 0 m (Nineth Slab)
506(J)From 56.40 to 62.40 m (Tenth Slab)
507Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
508(A) Upto Level 12.00 (First Slab)
509(B)From 12.00 -18.00 m (Second Slab)
510(C)Above 18.00 -24.00 m (Third Slab)
511(D)Above 24.00 m to 26.400 (Fourth Slab)
512(E)Above 26.400 m to 32.400 (Fifth Slab)
513(F)Above 32.400 to 38.400 m (Sixth Slab)
514(G)Above 38.40 to 44.40 m (Seventh Slab)
515(H)Above 44.40 to 50.40 m (Eigth Slab)
516(I)Above 50.40 to 56.4 0 m (Nineth Slab)
517(J)From 56.40 to 62.40 m (Tenth Slab)
518Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
519(B)From 12.00 -18.00 m (Second Slab)
520(C)Above 18.00 -24.00 m (Third Slab)
521(D)Above 24.00 m to 26.400 (Fourth Slab)
522(E)Above 26.400 m to 32.400 (Fifth Slab)
523(F)Above 32.400 to 38.400 m (Sixth Slab)
524(G)Above 38.40 to 44.40 m (Seventh Slab)
525(H)Above 44.40 to 50.40 m (Eigth Slab)
526(I)Above 50.40 to 56.4 0 m (Nineth Slab)
527(J)From 56.40 to 62.40 m (Tenth Slab)
528Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
529(A) Upto Level 12.00 (First Slab)
530(J)From 56.40 to 62.40 m (Tenth Slab)
531Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete.
532(A) Upto Level 12.00 (First Slab)
533(B)From 12.00 -18.00 m (Second Slab)
534(C)Above 18.00 -24.00 m (Third Slab)
535(E)Above 26.400 m to 32.400 (Fifth Slab)
536(F)Above 32.400 to 38.400 m (Sixth Slab)
537(G)Above 38.40 to 44.40 m (Seventh Slab)
538(H)Above 44.40 to 50.40 m (Eigth Slab)
539(I)Above 50.40 to 56.4 0 m (Nineth Slab)
540(J)From 56.40 to 62.40 m (Tenth Slab)
541Providing and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete.
542(A) Upto Level 12.00 (First Slab)
543(B)From 12.00 -18.00 m (Second Slab)
544(C)Above 18.00 -24.00 m (Third Slab)
545(E)Above 26.400 m to 32.400 (Fifth Slab)
546(F)Above 32.400 to 38.400 m (Sixth Slab)
547(G)Above 38.40 to 44.40 m (Seventh Slab)
548(H)Above 44.40 to 50.40 m (Eigth Slab)
549(I)Above 50.40 to 56.4 0 m (Nineth Slab)
550(J)From 56.40 to 62.40 m (Tenth Slab)
551Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
552(B)From 12.00 -18.00 m (Second Slab)
553(C)Above 18.00 -24.00 m (Third Slab)
554(E)Above 26.400 m to 32.400 (Fifth Slab)
555(F)Above 32.400 to 38.400 m (Sixth Slab)
556(G)Above 38.40 to 44.40 m (Seventh Slab)
557(H)Above 44.40 to 50.40 m (Eigth Slab)
558(I)Above 50.40 to 56.4 0 m (Nineth Slab)
559(J)From 56.40 to 62.40 m (Tenth Slab)
560Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
561(B)From 12.00 -18.00 m (Second Slab)
562(C)Above 18.00 -24.00 m (Third Slab)
563(E)Above 26.400 m to 32.400 (Fifth Slab)
564(F)Above 32.400 to 38.400 m (Sixth Slab)
565(G)Above 38.40 to 44.40 m (Seventh Slab)
566(H)Above 44.40 to 50.40 m (Eigth Slab)
567(I)Above 50.40 to 56.4 0 m (Nineth Slab)
568(J)From 56.40 to 62.40 m (Tenth Slab)
569Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
570(B)From 12.00 -18.00 m (Second Slab)
571(C)Above 18.00 -24.00 m (Third Slab)
572(E)Above 26.400 m to 32.400 (Fifth Slab)
573(F)Above 32.400 to 38.400 m (Sixth Slab)
574(G)Above 38.40 to 44.40 m (Seventh Slab)
575(H)Above 44.40 to 50.40 m (Eigth Slab)
576(I)Above 50.40 to 56.4 0 m (Nineth Slab)
577(J)From 56.40 to 62.40 m (Tenth Slab)
578Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
579(A) Upto Level 12.00 (First Slab)
580(J)From 56.40 to 62.40 m (Tenth Slab)
581Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete.
582(A) Upto Level 12.00 (First Slab)
583Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete.
584(A) Upto Level 12.00 (First Slab)
585(B)From 12.00 -18.00 m (Second Slab)
586(C)Above 18.00 -24.00 m (Third Slab)
587(E)Above 26.400 m to 32.400 (Fifth Slab)
588(F)Above 32.400 to 38.400 m (Sixth Slab)
589(G)Above 38.40 to 44.40 m (Seventh Slab)
590(H)Above 44.40 to 50.40 m (Eigth Slab)
591(I)Above 50.40 to 56.4 0 m (Nineth Slab)
592(J)From 56.40 to 62.40 m (Tenth Slab)
593Providing and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.
594(A) Upto Level 12.00 (First Slab)
595Providing and fixing 25mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock.[Without chamber].
596(A) Upto Level 12.00 (First Slab)
597Providing and fixing 40mm diameter water meter with non-return valve including strainer,sockets/ union nut and including water meter box making locking arrangements and lock. [Withoutchamber].
598(A) Upto Level 12.00 (First Slab)
599Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete.
600(A) Upto Level 12.00 (First Slab)
601(B)From 12.00 -18.00 m (Second Slab)
602(C)Above 18.00 -24.00 m (Third Slab)
603(E)Above 26.400 m to 32.400 (Fifth Slab)
604(F)Above 32.400 to 38.400 m (Sixth Slab)
605(G)Above 38.40 to 44.40 m (Seventh Slab)
606(H)Above 44.40 to 50.40 m (Eigth Slab)
607(I)Above 50.40 to 56.4 0 m (Nineth Slab)
608(J)From 56.40 to 62.40 m (Tenth Slab)
609Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow of all tanks capacity above 1000 to 20,000 litres
610(C)Above 18.00 -24.00 m (Third Slab)
611Providing , laying and fixing ,jointing Eco- drain 200 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavatedmaterialetc. complete.
612(A) Upto Level 12.00 (First Slab)
613Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete.
614(B)From 12.00 -18.00 m (Second Slab)
615(C)Above 18.00 -24.00 m (Third Slab)
616(E)Above 26.400 m to 32.400 (Fifth Slab)
617(F)Above 32.400 to 38.400 m (Sixth Slab)
618(G)Above 38.40 to 44.40 m (Seventh Slab)
619(H)Above 44.40 to 50.40 m (Eigth Slab)
620(I)Above 50.40 to 56.4 0 m (Nineth Slab)
621(J)From 56.40 to 62.40 m (Tenth Slab)
622Providing and fixing white european type wall-hung, of size 360mm x 360mm x 575mm with flush valve of approved make including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge.
623(B)From 12.00 -18.00 m (Second Slab)
624(C)Above 18.00 -24.00 m (Third Slab)
625(E)Above 26.400 m to 32.400 (Fifth Slab)
626(F)Above 32.400 to 38.400 m (Sixth Slab)
627(G)Above 38.40 to 44.40 m (Seventh Slab)
628(H)Above 44.40 to 50.40 m (Eigth Slab)
629(I)Above 50.40 to 56.4 0 m (Nineth Slab)
630(J)From 56.40 to 62.40 m (Tenth Slab)
631Providing and fixing white glazed urinal of series with Pressmatic auto closing valve of having 32mm diameter P.V.C. flush pipe with fitting and flushing of approved make and arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc.complete as directed byEngineer in charge.
632(A) Upto Level 12.00 (First Slab)
633(B)From 12.00 -18.00 m (Second Slab)
634(C)Above 18.00 -24.00 m (Third Slab)
635(E)Above 26.400 m to 32.400 (Fifth Slab)
636(F)Above 32.400 to 38.400 m (Sixth Slab)
637(G)Above 38.40 to 44.40 m (Seventh Slab)
638(H)Above 44.40 to 50.40 m (Eigth Slab)
639(I)Above 50.40 to 56.4 0 m (Nineth Slab)
640(J)From 56.40 to 62.40 m (Tenth Slab)
641Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer incharge.
642(A) Upto Level 12.00 (First Slab)
643(B)From 12.00 -18.00 m (Second Slab)
644(C)Above 18.00 -24.00 m (Third Slab)
645(E)Above 26.400 m to 32.400 (Fifth Slab)
646(F)Above 32.400 to 38.400 m (Sixth Slab)
647(G)Above 38.40 to 44.40 m (Seventh Slab)
648(H)Above 44.40 to 50.40 m (Eigth Slab)
649(I)Above 50.40 to 56.4 0 m (Nineth Slab)
650(J)From 56.40 to 62.40 m (Tenth Slab)
651Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete.
652(A) Upto Level 12.00 (First Slab)
653(B)From 12.00 -18.00 m (Second Slab)
654(C)Above 18.00 -24.00 m (Third Slab)
655(E)Above 26.400 m to 32.400 (Fifth Slab)
656(F)Above 32.400 to 38.400 m (Sixth Slab)
657(G)Above 38.40 to 44.40 m (Seventh Slab)
658(H)Above 44.40 to 50.40 m (Eigth Slab)
659(I)Above 50.40 to 56.4 0 m (Nineth Slab)
660(J)From 56.40 to 62.40 m (Tenth Slab)
661Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
662(A) Upto Level 12.00 (First Slab)
663(B)From 12.00 -18.00 m (Second Slab)
664(C)Above 18.00 -24.00 m (Third Slab)
665(D)Above 24.00 m to 26.400 (Fourth Slab)
666(E)Above 26.400 m to 32.400 (Fifth Slab)
667(F)Above 32.400 to 38.400 m (Sixth Slab)
668(G)Above 38.40 to 44.40 m (Seventh Slab)
669(H)Above 44.40 to 50.40 m (Eigth Slab)
670(I)Above 50.40 to 56.4 0 m (Nineth Slab)
671(J)From 56.40 to 62.40 m (Tenth Slab)
672Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc.complete.
673(A) Upto Level 12.00 (First Slab)
674(B)From 12.00 -18.00 m (Second Slab)
675(C)Above 18.00 -24.00 m (Third Slab)
676(D)Above 24.00 m to 26.400 (Fourth Slab)
677(E)Above 26.400 m to 32.400 (Fifth Slab)
678(F)Above 32.400 to 38.400 m (Sixth Slab)
679(G)Above 38.40 to 44.40 m (Seventh Slab)
680(H)Above 44.40 to 50.40 m (Eigth Slab)
681(I)Above 50.40 to 56.4 0 m (Nineth Slab)
682(J)From 56.40 to 62.40 m (Tenth Slab)
683Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete
684(J)From 56.40 to 62.40 m (Tenth Slab)
685Providing and applying one coat of seal cement primer of approved manufacture and shed including scaffolding preparing the surface by cleaning dirt and other foreign matters, scrapping if necessaryincluding scaffolding etc. complete.
686(A) Upto Level 12.00 (First Slab)
687(B)From 12.00 -18.00 m (Second Slab)
688(C)Above 18.00 -24.00 m (Third Slab)
689(D)Above 24.00 m to 26.400 (Fourth Slab)
690(E)Above 26.400 m to 32.400 (Fifth Slab)
691(F)Above 32.400 to 38.400 m (Sixth Slab)
692(G)Above 38.40 to 44.40 m (Seventh Slab)
693(H)Above 44.40 to 50.40 m (Eigth Slab)
694(I)Above 50.40 to 56.4 0 m (Nineth Slab)
695(J)From 56.40 to 62.40 m (Tenth Slab)
696(K)Above 62.40 m
697Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etccomplete.
698(A) Upto Level 12.00 (First Slab)
699(B)From 12.00 -18.00 m (Second Slab)
700(C)Above 18.00 -24.00 m (Third Slab)
701(D)Above 24.00 m to 26.400 (Fourth Slab)
702(E)Above 26.400 m to 32.400 (Fifth Slab)
703(F)Above 32.400 to 38.400 m (Sixth Slab)
704(G)Above 38.40 to 44.40 m (Seventh Slab)
705(H)Above 44.40 to 50.40 m (Eigth Slab)
706(I)Above 50.40 to 56.4 0 m (Nineth Slab)
707(J)From 56.40 to 62.40 m (Tenth Slab)
708(K)Above 62.40 m
709Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and otherforeign matter and sand papering as required etc. complete.
710(A) Upto Level 12.00 (First Slab)
711(B)From 12.00 -18.00 m (Second Slab)
712(C)Above 18.00 -24.00 m (Third Slab)
713(D)Above 24.00 m to 26.400 (Fourth Slab)
714(E)Above 26.400 m to 32.400 (Fifth Slab)
715(F)Above 32.400 to 38.400 m (Sixth Slab)
716(G)Above 38.40 to 44.40 m (Seventh Slab)
717(H)Above 44.40 to 50.40 m (Eigth Slab)
718(I)Above 50.40 to 56.4 0 m (Nineth Slab)
719(J)From 56.40 to 62.40 m (Tenth Slab)
720Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc.complete.
721(A) Upto Level 12.00 (First Slab)
722(B)From 12.00 -18.00 m (Second Slab)
723(C)Above 18.00 -24.00 m (Third Slab)
724(D)Above 24.00 m to 26.400 (Fourth Slab)
725(E)Above 26.400 m to 32.400 (Fifth Slab)
726(F)Above 32.400 to 38.400 m (Sixth Slab)
727(G)Above 38.40 to 44.40 m (Seventh Slab)
728(H)Above 44.40 to 50.40 m (Eigth Slab)
729(I)Above 50.40 to 56.4 0 m (Nineth Slab)
730(J)From 56.40 to 62.40 m (Tenth Slab)
731Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (AntiCorossive Paint)
732(J)From 56.40 to 62.40 m (Tenth Slab)
733Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.
734(B)From 12.00 -18.00 m (Second Slab)
735(C)Above 18.00 -24.00 m (Third Slab)
736(E)Above 26.400 m to 32.400 (Fifth Slab)
737(F)Above 32.400 to 38.400 m (Sixth Slab)
738(G)Above 38.40 to 44.40 m (Seventh Slab)
739(H)Above 44.40 to 50.40 m (Eigth Slab)
740(I)Above 50.40 to 56.4 0 m (Nineth Slab)
741(J)From 56.40 to 62.40 m (Tenth Slab)
742Providing and fixing 90 cm x 60 cm Granite plate engraving 10 cm. height letter, figures including painting the lefters/figures with approved colour and shade complete
743Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross bracedM.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge
744Providing and constructing Ductile Iron circular manhole 45 cm dia. At top 90 cm at bottom up to 1.80 meter to 2.70 meter depth including excavation, laying 1:4:8 cement concrete bedding 15 cm thick burnt brick mansonry with 1:1 cement mortar plaster 25 mm thick inside and outside 20 mm (1:3) ductile iron heavy type cover with ring 125Kilogramin weight. High strength. More life and Durability, Good Antiskid Grip, Suitable to heavy theatric loading, Light weight casting after cost benefits for Transportation Refilling etc. as per requirement. with prior approval of concerned Superitending Engineer.
745RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge
746RWH - Recharge PitProviding and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5\\" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10- 25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sandVSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approvedmake. All works complete as per the drawing, technical specification and direction of the Engineer in
747Boring/drilling bore well of 300mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level.
748Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well-casing pipe of 150mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer incharge.
749Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slopeincluding necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
750Providing and fixing C.P. sink cock with raised J\\" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete.\\"
751(A) Upto Level 12.00 (First Slab)
752(B)From 12.00 -18.00 m (Second Slab)
753(C)Above 18.00 -24.00 m (Third Slab)
754(E)Above 26.400 m to 32.400 (Fifth Slab)
755(F)Above 32.400 to 38.400 m (Sixth Slab)
756(G)Above 38.40 to 44.40 m (Seventh Slab)
757(H)Above 44.40 to 50.40 m (Eigth Slab)
758(I)Above 50.40 to 56.4 0 m (Nineth Slab)
759(J)From 56.40 to 62.40 m (Tenth Slab)
760Providing and fixing glass tiles of Mangalore type at required places in Mangalore tile roofincluding scaffolding if necessary etc. complete.
761(A) Upto Level 12.00 (First Slab)
762Door Closure: (For 2 Hr fire Rated EN-3 Door Closure)Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors of different size (e.g size -EN-3 for leaf width upto 900mm) CE certified, marked & conforming to EN - 1154 of approved quality (Internationally reputed brand like Dorma, Geze, Hafele, Assabloy & Magnum etc.) fitted and fixed Complete as per direction & satisfaction of Engineer -in Charge including all taxes & incidental charges.
763(A) Upto Level 12.00 (First Slab)
764Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc. complete
765(A) Upto Level 12.00 (First Slab)
766(B)From 12.00 -18.00 m (Second Slab)
767(C)Above 18.00 -24.00 m (Third Slab)
768(E)Above 26.400 m to 32.400 (Fifth Slab)
769(F)Above 32.400 to 38.400 m (Sixth Slab)
770(G)Above 38.40 to 44.40 m (Seventh Slab)
771(H)Above 44.40 to 50.40 m (Eigth Slab)
772(I)Above 50.40 to 56.4 0 m (Nineth Slab)
773(J)From 56.40 to 62.40 m (Tenth Slab)
774Providing and fixing lioghtening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25mm dia. 1.2 mm thick with multiple points head 1.2 mt. long ( Heavy Duty) welded or clamped to G.I. pipe pole B grade 50 mm diaof requiired length with M.S. round bnase plate 25 Cm diam and 10mm thick at bottom embeded in cement concrete 1:3:6 dfoundation of size 45 cm diam x 45 cm Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 cms with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40Kilogramcharcoal and salt with altemate layers of charcoal and salt and G.I.pipe 40mm dia 2 meter length burried in earthe upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item.
775Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.
776(A) Upto Level 12.00 (First Slab)
777(F)Above 32.400 to 38.400 m (Sixth Slab)
778(K)Above 62.40 m
779Providing and fixing during laying in RCC Slab rectangular 2 mm thick M.S. sheet fan hook box of size 180x100 mm with required depth with holes or notches as required, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws together with 12 mm dia. M.S. bar bent to shape withhooked ends for fan hook and painting to exposed surface
780(A) Upto Level 12.00 (First Slab)
781(B)From 12.00 -18.00 m (Second Slab)
782(C)Above 18.00 -24.00 m (Third Slab)
783(D)Above 24.00 m to 26.400 (Fourth Slab)
784(E)Above 26.400 m to 32.400 (Fifth Slab)
785(F)Above 32.400 to 38.400 m (Sixth Slab)
786(G)Above 38.40 to 44.40 m (Seventh Slab)
787(H)Above 44.40 to 50.40 m (Eigth Slab)
788(I)Above 50.40 to 56.4 0 m (Nineth Slab)
789(J)From 56.40 to 62.40 m (Tenth Slab)
790Providing and laying jointless Polydee-LM, a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, after application of TP- 42 Primer on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee-LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing the same with sprinkling the AG-10 granules on the wet coating. (After finishing covering the treatment with 25mm cement plaster for protection with fibrillated 6mm Plyplast fibre @ 125 gms/Square Metre to be paid in separate item.) covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete.
791(A) Upto Level 12.00 (First Slab)
792(K)Above 62.40 m
793Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap /granite / gneiss/ quartzite metal for R.C.C.Decorative Form Finish Column Capital/Pedestial per detailed Architectural design and drawings or as directed including sepcially desgined steel mould formwork centering, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement, including cover block). Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed) With fine aggregate (Crushed sand VSI Grade)
794(A) Upto Level 12.00 (First Slab)
795(B)From 12.00 -18.00 m (Second Slab)
796(C)Above 18.00 -24.00 m (Third Slab)
797(D)Above 24.00 m to 26.400 (Fourth Slab)
798(E)Above 26.400 m to 32.400 (Fifth Slab)
799(F)Above 32.400 to 38.400 m (Sixth Slab)
800(G)Above 38.40 to 44.40 m (Seventh Slab)
801(H)Above 44.40 to 50.40 m (Eigth Slab)
802(I)Above 50.40 to 56.4 0 m (Nineth Slab)
803Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap /granite / gneiss/ quartzite metal for R.C.C.Decorative Form Finish ARCH per detailed Architectural design and drawings or as directed including sepcially desgined steel mould formwork centering, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement, including cover block). Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed) With fine aggregate (Crushed sand VSI Grade)
804(A) Upto Level 12.00 (First Slab)
805(H)Above 44.40 to 50.40 m (Eigth Slab)
806(I)Above 50.40 to 56.4 0 m (Nineth Slab)
807(J)From 56.40 to 62.40 m (Tenth Slab)
808Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap /granite / gneiss/ quartzite metal for R.C.C.Decorative Form Finish CORNICES/CORBLES 300 x 150 mm thick per detailed Architectural design and drawings or as directed including sepcially desgined steel mould formwork centering, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement, including cover block). Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed) With fine aggregate (Crushed sand VSI Grade)
809(A) Upto Level 12.00 (First Slab)
810(B)From 12.00 -18.00 m (Second Slab)
811(C)Above 18.00 -24.00 m (Third Slab)
812(D)Above 24.00 m to 26.400 (Fourth Slab)
813(E)Above 26.400 m to 32.400 (Fifth Slab)
814(F)Above 32.400 to 38.400 m (Sixth Slab)
815(G)Above 38.40 to 44.40 m (Seventh Slab)
816(H)Above 44.40 to 50.40 m (Eigth Slab)
817(I)Above 50.40 to 56.4 0 m (Nineth Slab)
818Providing and Fixing Cladding in Dholpuri Stone Cladding (Natural Dholpuri Stone) on vertical faces of wall upto specified heigth with 30 mm thick gang saw cut stone with machine cut edges of uniform colour ans size upto 0.3 x 0.15 m fixed to structural steel frame work and / or with help of cramps, pins etc and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer Incharge. including the steel frame work, stainless steel cramps and pins etc complete
819(A) Upto Level 12.00 (First Slab)
820(B)From 12.00 -18.00 m (Second Slab)
821(C)Above 18.00 -24.00 m (Third Slab)
822(D)Above 24.00 m to 26.400 (Fourth Slab)
823(E)Above 26.400 m to 32.400 (Fifth Slab)
824(F)Above 32.400 to 38.400 m (Sixth Slab)
825(G)Above 38.40 to 44.40 m (Seventh Slab)
826(H)Above 44.40 to 50.40 m (Eigth Slab)
827(I)Above 50.40 to 56.4 0 m (Nineth Slab)
828(J)From 56.40 to 62.40 m (Tenth Slab)
829Providing and Fixing Dholpuri StoneJalli decorative and Architecturaly screen created from Natural Dhopuri Stone of specified colour( Beige/Cream/Red/Pink) traditional CNC cut design in the specified pattern including all lead as Directed by Engineer Incharge
830(A) Upto Level 12.00 (First Slab)
831(B)From 12.00 -18.00 m (Second Slab)
832(C)Above 18.00 -24.00 m (Third Slab)
833(D)Above 24.00 m to 26.400 (Fourth Slab)
834(E)Above 26.400 m to 32.400 (Fifth Slab)
835(F)Above 32.400 to 38.400 m (Sixth Slab)
836(G)Above 38.40 to 44.40 m (Seventh Slab)
837(H)Above 44.40 to 50.40 m (Eigth Slab)
838Providing and Fixing in position Structural Glazing for faces of building made out of colour anodised aluminium frame curtain wall of 63 mm x 57 mm , 2.20 mm thick including toughned reflective glass 10 mm thickness of specified shape and panel size with water proofing silicon sialent , G.E Winsil 10/20 G.E Ultra Glaze with aluminim fixtures, S.S screws and nut bolts, scafolding, M.S angle cleats and frame work of 65 mm x 65 mm x 6 mm angle etc complete (Minimum 20 % area of structural glazing shall be of openable panels with Aluminium hings, wind stays and locking arrangement and aluminium angle or Tee section of required size if required) as directed by Engineer Incharge
839(A) Upto Level 12.00 (First Slab)
840(I)Above 50.40 to 56.4 0 m (Nineth Slab)
841(J)From 56.40 to 62.40 m (Tenth Slab)
842Loading transporting and unloading excavated material of all kinds from the excavation site to the designated disposal site with the lead up to 15 km including spreading or stacking as directed etc complete as directed by the engineer in charge.
843ELECTRICAL
844Sub Work A : E.I.Providing Internal Electricalinstallations for Proposed Construction of Marathwada Mukti Sangram Smarak Building At Chhatrapati Sambhajinagar
845Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
846Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
847Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
848Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specificationNo. WG-MA/CC.
849Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON.
850Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
851Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
852Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
853Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places as per specification No: WG-MA/BW
854Supplying & erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
855Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
856Supplying & erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
857Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/Bus bars or any other places.as per specification No: WG-MA/BW
858Supplying & erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking /inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW (LDB Circuit)
859Supplying & erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW (LDB Circuit earth)
860Supplying & erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole /Bus bars or any other places as per specification No: WG-MA/BW (PDB & Main LDB Circuit) (Rs 103 x 2 = 206)
861Supplying & erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (PDB Circuit earth) (Rs 103 /2 = 51.50)
862Supplying & erecting mains with 4x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (Main PDB Circuit)
863Supplying & erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (PDB Circuit earth)
864Supplying and erecting mains with 4x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other placesas per specification No: WG-MA/BW
865Supplying and erecting mains with 1x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
866Supplying and erecting mains with 4x25 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other placesas per specification No: WG-MA/BW
867Supplying and erecting mains with 1x25 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other placesas per specification No: WG-MA/BW
868Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
869Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
870Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
871Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
872Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
873Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
874Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected.
875Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background
876Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
877Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background.
878Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with requiredchiselling and finishing with cement mortar / POP as per required to match the background
879Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected.
8801-w- Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ CW
8812-w- Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ CW
882Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ CW
883Point wiring for independent plug, concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No WG-PW/SW
884Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit/ casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switc
885Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
886Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
887Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
888Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
889Wiring for plug on board with Switch socket surface/ concealed type, copper wiring and earthing and with modular accessories as per specification No: WP W/CW
890Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG6 as per specification No. WG
891Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
892Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
893Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
894Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
895Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
896Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
897Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
898Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
899Supplying and erecting integrated LED street light fitting 18 to 22W IP65 & IK08 class having single piece pressure die-cast aluminium housing, havingsystem lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140- 270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FGODF/FLS2
900Supplying and erecting street light Wall bracket made from 25 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB
901Supplying & erecting 5W-7W,, 230V integral type LED Lamp suitable for B-22 / E-27 base.
902Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
903Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% without IR remote control/ compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
904Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original
905Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab
906Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. (for ceiling Fn)
907Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
908Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
909Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCBB
910Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
911Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
912Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 63A in provided distribution board.
913Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 80/100A in provided distribution board.
914Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
915Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
916Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
917Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as perspecification no. SW-SWR/MCBDB
918Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GIframe as per specification no. SW-SWR/MCBDB
919Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/ MCBDB1
920Providing & erecting 4 Pole MCCB, 415 V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
921Supplying, fixing and commissioning 2 pole, RCBO 25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 100 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
922Supplying, fixing and commissioning 4 pole RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indications per specification no SW-RCCB/RCBO
923Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/ RCBO
924Supplying, fixing and commissioning 4 pole RCBO 63A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
925Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
926Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
927Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP- (1.6x2 + 0.6x1 + 0.4x8 = 7 x 4 Bus = 28 Mtr x 2.7 Kg/ Mtr))
928Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
929Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
930Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs.
931Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
932Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring &connections etc.
933Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
934Supplying, installation & marking of surge arrestor / surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 100 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD
935Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (Shop supply cable)
936Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (Sub Main Lighting DB Cable)
937Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (Sub Main Power DB Cable)
938Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (Pump Room DB Cable)
939Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (Lift Main DB Cable)
940Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (Shop Meter Panel Cable)
941Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (8Way VTPN MCCB - Main Lighting & Power DB Cable)
942Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (Main Cable for HVAC Supply)
943Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (3 Run OF Main Cable for main LT panel Supply)
944Supplying and laying (including excavation of suitable width & depth up to 90 cm) 160 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.e.(From Transformer LT Panel to Main MCCB Panel Cable- Panel Room)
945Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware
946Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 500 mm width & 75 mm height complete with necessary coupler plates & hardware.
947Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI (MLDB-1, MPDB-1, Main Lift DB-1, Pump Room DB-1, Main LT Panel-2, LA-3, Shop-1)
948Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no EA-EP. (for all Earthings)
949Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no EA-EP. (for LA to ground Earthings)
950Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
951Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specificationno. AP-WCR/WC
952Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system..
953Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
954Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
955Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
956Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB
957Providing & erecting 3 Pole MCCB 415V, 630A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in providedenclosure/panel as per specification no. SW-SWR/MCCB
958Supplying, installing, testing and commissioning air circuit breaker manual drawout type, 650V, 1600A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA, (Ics=Icu=Icw for 1s),with standard accessories with ready to close, individual fault trip, alarm and trip indication, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB (1 No- Main LT panel Incomer)
959Supplying and erecting metal work in CRCA (14 SWG) sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
960Supplying and erecting Iron, sheet metal work consisting of CRCA Sheets, Various sections of iron, Plates, Chequered Plates, Rods, Bars, MS pipes, etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority
961Supplying & erecting of required size electrolyte copper bus patti or bar tin plated in bus bar chamber/in panel or any other purpose, suitable for 500 volt with require capacity having thermal conductivity of 400W per meter with composition Pure copper 99.9% Current density 1.8 with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB - (Bus Bar size-160x10mm: 1.6x2 + 0.6x1 + 0.4x8 = 7 x 4 Bus = 28 Mtr x 14.200 Kg/ Mtr))
962SSupplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
963Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/Bus bars or any other places as per specification No: WG-MA/BW
964Supplying & erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/Bus bars or any other places as per specification No: WG-MA/BW
965Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
966Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GIframe as per specification no. SW-SWR/MCBDB
967Supplying, fixing and commissioning 2 pole, RCBO 25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 100 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
968Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALL (for all shops supply)
969Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (Vijay Stambha Supply Cable)
970Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
971Supplying and erecting integrated LED flood light fitting Max. 30W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 3000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. (on booking counter, Food Plaza, on Ticket counter)
972Supplying, erecting, testing and commissioning of 10kW, 3 x 3.3 KW AC Electric Vehicle charger (suitable for 2/3/4 wheeler) having minimum IK08/IP 54 Protection suitable for three phase, 415V AC, 50Hz incoming and 3 nos. output as per IEC 60309 industrial sockets having capacity of output current of 16A 240V AC at each socket with 3.5\\"TFT touch screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, one hour battery backup for communication, emergency push stop button and having short circuit, over & under voltage, overload, over temperature, earth leakage protection and enclosure made of minimum 1.5mm duly RAL7035 Coated M.S, Erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming to IS 17017 Series as per specification
973Supplying, erecting, testing and commissioning of 15 KW DC Electric Vehicle Charger (suitable for 4 wheeler) having minimum IK08 & IP54 protection suitable for three phase 415V AC 50Hz incoming supply and 1 no. output charger interface GB/T with 40-100VDC supply and 15 kW capacity, interlocking arrangement with minimum 5 meter charging cable length , 7\\" LCD touch screen for human interface & LED light for status indication, metering for measurement of consumed energy having metering accuracy +/-1%, One hour battery backup for communication, emergency push stop button. User interface by mobile application/QR Code/RIFD Card/ Password Login with payment options and having short circuit, over & under voltage, surge protection, earth leakage protection and enclosure made of minimum 1.5mm duly RAL7035 coated M.S, erected on iron/GI frame on provided cement concrete foundation completewith one year on site warranty, confirming to IS 17017 Series as per specification
974Providing yearly subscription of payment gateway option for AC/DC EV Charger CMS (Charger management software) system for billing and payment gateway along with mobile application /android/IOS base app to facilitate charging, CMS should have ISO/IEC 27001:2003 certification
975Supply of high quality recessed COB tiltable downlight , 3000K / 4000K / 6000K CCT, Die cast aluminium housing, Customized body colour, with reflector, Beam angle 38 °, ixture should have minimum net efficacy at System level (Not Chip Level) ≥100 lumens/watt, a maximum rating of 20Watts, minimum nominal system lumen of 2000 lumens, Life of fixture 50000 hrs@ L70 Lumen maintenance, CCT 4000K , CRI >80, PF >0.9, IP20 (min.), Input Voltage (V AC): 220-240, 50HZ, Operating temperature: 0 °C – 40 °C, UGR<19, RIPPLE<5%, THD<10%, Internal Surge Protection ≥4KV, and LED driver shall be BIS registered & luminaire manufacture shall provide LM79 report from NABL accredited lab & LM80 report issued by LED manufacturer.
976Supply of high quality recessed COB fixed downlight , 3000K / 4000K / 6000K CCT, Customized body colour with reflector, Beam angle 38 °, Fixture should have minimum net efficacy at System level (Not Chip Level) ≥100 lumens/watt, a maximum rating of 12Watts, minimum nominal system lumen of 1200 lumens, Life of fixture 50000 hrs@ L70 Lumen maintenance, CCT 4000K , CRI >80, PF >0.9, IP20 (min.), Input Voltage (V AC): 220-240, 50HZ, Operating temperature: 0 °C – 40 °C, UGR<19, RIPPLE<5%, THD<10%, Internal Surge Protection ≥4KV, and LED driver shall be BIS registered & luminaire manufacture shall provide LM79 report from NABL accredited lab & LM80 report issued by LED manufacturer.
977Supply of high quality 25W Acrux track light 3000K / 4000K / 6000K CCT, Die cast aluminium housing, Customized body colour, with reflector, Beam angle 38 °, Fixture should have minimum net efficacy at System level (Not Chip Level) ≥100 lumens/watt, a maximum rating of 25Watts, minimum nominal system lumen of 2500 lumens, Life of fixture 50000 hrs@ L70 Lumen maintenance, CRI >80, PF >0.9, IP20 (min.), Input Voltage (V AC): 220-240, 50HZ, Operating temperature: 0 °C – 40 °C, UGR<19, RIPPLE<5%, THD<10%, Internal Surge Protection ≥4KV, and LED driver shall be BIS registered & luminaire manufacture shall provide LM79 report from NABL accredited lab & LM80 report issued by LED manufacturer.With 2 Mtr track bar , live cap , dead end cap, i jointer required for the fittings.
978Supply, installation, testing and commissioning of Full range 2.25-inch or better IP55 rated surface mounted music and PA loudspeaker. The loudspeaker shall meet the following performance criteria: Frequency range (-10dB) of 83Hz to 19kHz or better; Power handling of 64 Watt peak or more; Nominal dispersion of 100°(H) × 80°(V) or better; Sensitivity of 84 dB SPL or more and Max SPL of 103 dB SPL peak or better; Nominal impedance of 16 ohms and Integral multi-tap Transformer with selectable tap settings of 2/4/8/16W@70V & 100V. The loudspeaker system shall be enclosed in engineered-plastics and a powder-coated steel grille. UL-1480 rated and EN54-24 compliant for Life safety/VA applications.
979Supply , installation , testing and commissioning of full range 2.25-inch or better ceiling mounted music and PA loudspeaker. The loudspeaker shall meet the following performance criteria: Usable Frequency range (-10 dB) of 85Hz to 17kHz or better; Power handling of 64 Watt peak or more; Nominal dispersion of >=130° Conical or better; Sensitivity of 84 dB SPL or better and Peak SPL of 102 dB SPL or better; Nominal impedance of 16 ohms and Integral multi-tap Transformer with selectable tap settings of 2/4/7.5/15W@70V & 100V or better. The loudspeaker shall be enclosed in engineered-plastics with integrated steel back can and a powder-coated steel grille. UL-1480 rated and EN54-24 compliant for Life safety/VA applications.
980SITC of Class D configurable amplifier with total 4 x 300W / 2 x 600W output power or better @ 4/8ohms, 70/100 Volt or mixed use operation; Frequency Response : 20Hz - 20kHz for LZ mode ;THD <0.04% at rated output complete with standard accessories as required.
981SITC of Digital Audio Conferencing Processor with at least 12 Mic/Line inputs & 8 analogy outputs, 24 Bit A-D and D-A Convertors; Sampling Rate : 48 kHz; THD : < 0.002 % ; Channel Separation (Crosstalk) : < 108 dB ; Frequency Response 20 Hz - 20 kHz ; Signal-to-Noise Ratio 90 dB ;Dynamic Range > 115 dB; 5 Control Inputs and Outputs; RS-232 and Ethernet Port for third party Control and Monitoring; 32X32 or more Bidirectional DANTE Audio Networking ports, Shall include USB Audio as standard Feature. inbuilt DSP features like Conference room Routers, Input Equalizers, Router, Band Pass filter, Output Equalizer, Delay, Limiters, gates , Source selectors etc. Shall Support at least 15 remote Zone controllers
982Supply, installation, testing & Commissioning of programmable Audio DSP controller with Display and programmable encoder knobs. Multiple programmable settings configurable over Ethernet. Source Selection and Volume Controls ; Supports Up to 256 programmable Functions Shall include any accessory to make the system functional.
983Supply , installation , testing and commissioning of Music Player etc. complete spec & no. as diercted by engg incharge.
984Supply , installation , testing and commissioning of Paging Mic etc. complete spec & no. as diercted by engg incharge.
985SITC of 2 core Twisted, shielded balanced Audio and control cable with 20AWG or better 7 strand annealed bare copper conductors, Semi-Rigid PVC insulation, Riser rated PVC jacket. UL 444, UL 13 CMR rated complete spec & no. as diercted by engg incharge.
986SITC of 2 core Twisted, shielded balanced Audio and control cable with 20AWG or better 7 strand annealed bare copper conductors, Semi-Rigid PVC insulation, Riser rated PVC jacket. UL 444, UL 13 CMR rated complete spec & no. as diercted by engg incharge.
987SITC of 2 core 14 AWG/2.5 Sq. mm, Twisted, unshielded Speaker cable with stranded annealed bare copper conductors, Semi-rigid PVC insulation, NEC CL3R, CEC CMG, RoHS compliant
988SITC of 4 pair shielded/foiled TIA/EIA-568-C Category 6A cable with 23AWG or better Solid annealed bare copper conductors, High-density polyethylene insulation, Flame rated PVC jacket, Overall aluminium/poly foil shield with drain, NEC CMR, CEC CMR FT4, RoHS compliant.
989Supply , installation , testing and commissioning of Connector for interconnectivity etc. complete spec & no. as diercted by engg incharge.
990Supplying and installing cat-6 STP cable suitable for networking complete as per specification. ( CAT 6A)
99124 PORT SWITCH- Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS
992Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch,10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rackcomplete.
993Supplying and fixing 24 port patch panel with tool-less keystone jacks inprovided U Rack complete as per specification no. WG-NAS/PP
994Supplying and fixing tool-less IO (Ethernet) flush/surface type in providedmodular box as per specification no. WG-NAS/IO
995RJ 45 JACK- Supplying, installing and testing UTP connector (RJ-45) as per specification No.WG-NAS/UTPC.
996PATCH CORD : Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
9971 Supplying and erecting PVC box trunking of size 50x50 mm. withaccessories on wall/ceiling as per specification No: WG-MA/BOX.
998SERVER RACK with patch panel - Supplying and fixing 42 U floor mount server rack (Dimension-DxWxH – 800x1000x2070 mm) as per specification No. WG-NAS/RAK
999Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK
1000Supplying and erecting LSZH armoured multimode optical fibre cable with 6fibres, core dia 50/125 µm (OM3), suitable upto 10 GBPS, ethernet distance at850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as perspecification no. WG-COC/OFC LSZH
1001SFP MODULE
1002Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64,Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD
1003Supplying and erecting PVC box trunking of size 50 X 16/20mm with accessories on wall/ceiling as per specification no:WG-MA/BOX
1004Supplying and erecting HMS PVC conduit FRLS grade 32mm dia. With PVC accessories on wall/ceiling as per specification No:WG-MA/CON
1005Supplying and erecting GI flexible Conduit 25mm dia.conforming to I.S with required number of couplings,bushes,check nuts etc. complete
1006Sub Work B : External ElectrificationProviding External Electrical installations, façade lights, street lights etc for Proposed Construction of Marathwada Mukti Sangram Smarak Building At Chhatrapati Sambhajinagar
1007Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
1008Supplying and erecting integrated LED street light fitting 85-90W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 9300 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2..
1009Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 800mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2
1010Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation.
1011Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB (Street Light Pole)
1012Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1013Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1014Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
1015Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB .
1016Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
1017Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
1018Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
1019Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
1020Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no.EA-EP
1021Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
1022Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT (2R X 200)
1023Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. (Except bitumen carpet). (10 mtr of 2 mtr)
1024Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete
1025Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT
1026Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT
1027Supplying, erecting, testing & commissioning 11 kV, 630A, 21kA/3sec, 3 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 2 nos. feeder with 2 LBS and 1 no. feeder with 1 VCB. compliant to IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA
1028Supplying, erecting, testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating/ epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 50/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 11000/ V3 /110/ V3 VA 50, Class 0.2 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation..
1029Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
1030Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP (RMU-2).
1031Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP.
1032Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP
1033Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP (Civil work (foundation) for Meter Cubical)
1034Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz.,1000 kVA, Mineral oil immersed and naturally cooled outdoor type, Copperwound Non-sealed transformer, delta/star connected with additional neutralbrought out on load side, temperature rise should not exceed 45℃ bythermometer in oil and 50℃ by the resistance method in winding at full loadrating, using type A winding insulation (kraft paper), with HV tapping (withon load tap changer) on load +5 to -15 in steps of 2.5%, with standardaccessories complete with test certificate with losses below 2930 Watts at 50%load, 8085 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessarypermissions of Electrical Inspector, as per specification no SS- TR-NSL.
1035Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete
1036Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB
1037Supplying, installing, testing and commissioning air circuit breaker manual drawout type, 650V, 1600A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA, (Ics=Icu=Icw for 1s),with standard accessories with ready to close, individual fault trip, alarm and trip indication, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB (2 No for 2 Nos Transformer incomer supply, 1 No for Bus Coupler)
1038Supplying and erecting metal work in CRCA (14 SWG) sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
1039Supplying and erecting Iron, sheet metal work consisting of CRCA Sheets, Various sections of iron, Plates, Chequered Plates, Rods, Bars, MS pipes, etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority
1040Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP- (1.6x2 + 0.6x1 + 0.4x8 = 7 x 4 Bus = 28 Mtr x 2.7 Kg/ Mtr))
1041Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CCfoundation and painted complete as per specification no SS-AS/FSG (sub station yard 10 mtr x 6 mtr Compound wall 3 sides= 10 + 6 + 10 = 26 mtr/ 1.2 mtr= 21.66 - double leaf hinged door of 1500x2=3000 (less 3 mtr) mm in width= 18.67 )
1042Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.
1043Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD
1044Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete.. (9 mtr X 6 mtr
1045Supplying and erecting triple pole mini feeder pillar with 500V, 300A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation as per specification no. SW-SWR/MFP
1046Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (From Transformer Main LT Panel to Mini feeder PAnel)
1047Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.(From Transformer LT Panel to Main MCCB Panel Cable- Panel Room)
1048SITC of high quality long through Multi colour with RGBW 4in1 LED, DMX-RDM based linear wash light, Protection Rating: IP66, complying to BIS standard \\"IS 10322 (Part 5/Sec 1): 2012\\" and having CE certification against standard \\"Low Voltage Directive & Protective Equipment - EN 60598 (Part 2/Sec 1):2020\\", and \\"Electromagnetic Compatibility Directive - EN 61547:2020\\", Mounting Structure: Adjustable surface mount yoke arrangements in the die cast for fixing. Power consumption: 80W, CCT: RGBW (6000K - 7000K) (as per the design approval), Optics: PMMA/PC Lens with holder, Beam Angle: 25°/45°/60°(as per the design approval), Luminous Efficacy must be Min : 55Lm/W, Body: Die casted/ extruded aluminium with embossed manufacturer logo, Separate compartment for keeping the decoder/driver in the housing which can be easily removable for service without disturbing the LEDs/Optics, Hot spot and light distribution: Optics Designed to minimize hot spots & fringing in colour mixing applications. Luminaire shall be capable of producing dynamic colour-changing light with 16.7million colours and it shall support control via DMX, Ethernet, and Remote Device Management (RDM) for enhanced configuration and management. The luminaire should offer channel options of 8/ 4 channels by using a Programming kit, with these channels providing control for effects and colour transitions like 4 colour 4 channels, Master, Jump/ strobe, Micro function and speed. Additionally, it shall feature auto colour synchronization functionality, allowing seamless operation if there is a loss of DMX signal/ with loop in loop out. Power Input: DC 24V External Group Driver, Surge Protection: Inbuilt surge protection in the driver 2KV-4KV (Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection: IK07 or higher, Painting: Chemical 3/7 tank processed treatment before the powder coat black/Grey/approved colour coat. Fixture will be suitable to operate in a temperature range of -10°C to +60°C, the light fixtures are having IP68 air vent made of stainless steel which helps to desiccate & prevent from forming moisture inside the light fixture at worst environmental condition. LED life should be at least 50,000 burning hours at L70 at 50 degrees centigrade. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. PCB thickness must be 1.6mm, 35-micron Copper, 2W TC with Black or White masking, Copper /OSP finish. LM79, IK07, HV & IP66 Certificates from NABL Accredited laboratory. LED Makes should be CREE, LumilLED, Osram, Seoul, Nichia or equivalent with the engineer or 3rd party testing laboratory approval. Power & DMX Loop In/Out along with moulded connector having the length >300mm. Certifications: CE, RoHS, BIS.
1049SITC of high quality long through multi colour with RGBW 4in1 LED, DMX-RDM based wash light, Protection Rating: IP66, complying to BIS standard \\"IS 10322 (Part 5/Sec 1): 2012\\" and having CE certification against standard \\"Low Voltage Directive & Protective Equipment - EN 60598 (Part 2/Sec 1):2020\\", and \\"Electromagnetic Compatibility Directive - EN 61547:2020\\", Mounting Structure: Adjustable surface mount yoke arrangements for fixing the lights having the rotation degrees embossed in the die cast. Power consumption: 150W, CCT: RGBW (6000K -7000K) (as per the design approval), Optics: PMMA/PC Lens with separate holder, Beam Angle: 25°/45°/60°(as per the design approval), Luminous Efficacy must be Min : 55Lm/W, Body: Die casted/ extruded aluminium with embossed manufacturer logo, Separate compartment for keeping the decoder/driver in the housing which can be easily removable for service without disturbing the LEDs/Optics, Hot spot and light distribution: Optics Designed to minimize hot spots & fringing in colour mixing applications. Luminaire shall be capable of producing dynamic colour-changing light with 16.7million colours and it shall support control via DMX, Ethernet, and Remote Device Management (RDM) for enhanced configuration and management. The luminaire should offer channel options of 8/ 4 channels by using a Programming kit, with these channels providing control for effects and colour transitions like 4 colour 4 channels, Master, Jump, strobe, Macro function and speed in the rest 4 channels as per the requirement. Additionally, it shall feature auto colour synchronization functionality, allowing seamless operation if there is a loss of DMX signal/ with loop in loop out. Power Input: DC 24V External Group Driver, Surge Protection: Inbuilt surge protection in the driver 2KV-4KV (Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection: IK08 or higher, Painting: Chemical 3/7 tank processed treatment before the powder coat black/Grey/approved colour coat. Fixture will be suitable to operate in a temperature range of -10°C to +60°C, the light fixtures are having IP68 air vent made of stainless steel which helps to desiccate & prevent from forming moisture inside the light fixture at worst environmental condition. LED life should be at least 50,000 burning hours at L70 at 50 degrees centigrade LM80 to be provided. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. PCB thickness must be 1.6mm, 35-micron Copper, 2W TC with Black or White masking, Copper /OSP finish. LM79, IK08, HV & IP66 Certificates from NABL Accredited laboratory. LED Makes should be CREE, LumilLED, Osram, Seoul, Nichia or equivalent with LM80 report from as international testing Laboratory. Power & DMX Loop In/Out along with moulded connector having the length >300mm. Certifications: CE, RoHS, BIS.
1050SITC of High quality Decorative Single Arm 50W Post Top Light, Power Input: 3000K, Size : 3000mm Impact resistant polycarbonate/metal housing, 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 76 mm A/F on provided foundation as per specification no. OH-PL/OPL GU24/E26 base, Material: GI Iron, Protection Rating : IP65, Input power : AC 110 - 230V, 50Hz.
1051Supplying and erecting electronic type Driver for Outdoor LED Fittings 151W- 200W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%.
1052SITC of PVC insulated multi core electrical un armoured flexible 3C x 1.5Sq mm power cable having less electrical losses. This PVC insulated and round sheathed wire features a bright multi strands copper conductors and it supports voltage grade up to 1100V. (As per actuals depending upon the site condition)
1053SITC of PVC insulated multi core electrical un armoured flexible 3C x 2.5Sq mm power cable having less electrical losses. This PVC insulated and round sheathed wire features a bright multi strands copper conductors and it supports voltage grade up to 1100V. (As per actuals depending upon the site condition)
1054Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1055SITC of 5 core DMX cable comprises twisted pairs with shield support for carrying of data. DMX512 cable is used for connecting all light consoles that use DMX 512 standard data transmission. (As per actuals depending upon the site condition)
1056SITC of 5 pin XLR Male connectors having 5 pole cable connector, Male/Female connector with improved latch, cage type contacts, \\"solder stop\\" for easy soldering, and additional ground contact for best contact integrity between chassis and cable connector. More durable housing for maximum reliability.
1057SITC of 5 pin XLR Female connectors having 5 pole cable connector, Male/Female connector with improved latch, cage type contacts, \\"solder stop\\" for easy soldering, and additional ground contact for best contact integrity between chassis and cable connector. More durable housing for maximum reliability.
1058SITC of 25 mm medium duty PVC conduit, ISI‑marked, surface‑mounted with clamps, saddles, and galvanized fasteners. Includes bends, junction boxes, couplers, tees, inspection covers, and accessories. Work executed per IE rules, ensuring alignment, durability, neat finish, safe wiring, and complete functional system.
1059Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA
1060SITC of Main Power Distribution Board made up of MS Sheet metal fabricated housing black powder coated and Ivery connectors for the internal terminations and external outgoing connecting points, fibre / brass glands of suitable size fitted MCB control for outgoing circuits. Timer with required contactor for auto switching. Power panel suitable for indoor/outdoor applicable and floor mount / wall mount options.- 2 Nos of 32A TPN MCB Outgoing MCBs. - 1No of 63A TPN Incoming MCB.
1061SITC of Sub Power Distribution Board made up of MS Sheet metal fabricated housing black powder coated and Ivery connectors for the internal terminations and external outgoing connecting points, fibre / brass glands of suitable size fitted MCB control for outgoing circuits. Timer with required contactor for auto switching. Power panel suitable for indoor/outdoor applicable and floor mount / wall mount options.- 12 Nos of 6/10A SP Outgoing MCB's.- 1No of 32A TPN Incoming MCB.
1062SITC of IP driver box made up of PVC / UPVC for the internal terminations and external outgoing connecting points, with required PVC / brass glands, Optional suitable size MCB fitted for control outgoing circuits.
1063SITC of DMX isolator or splitter provides Isolated optical DMX splitter provides 8 outputs from a 1 input and Input voltage: AC 110 to 220 V, 50 Hz, Product features: Group 1 & group 8 DMX signal change.
1064SITC of Din Rail Mount DMX controller can be used to control a wide variety of different DMX systems- from RGB/RGBW to more advanced moving and colour mixing luminaires, DMX audio players and fountains. The controller comes with a variety of features, iPhone/iPad/Android remote control, Wi-Fi facilities, dry contact port triggering and flash memory.USB connection • 1024 DmX channels universe in live mode (computer) • 8 dry contact trigger ports via HE10 connector • stand alone mode with 5 area and 90+ scenes, Mac OSx 10.6/10.7/10.8 - Windows XP/VISTA/SEVEN/8 32/64 bits and USB 2.0, XLR3, mini USB, 1 HE10, Power From 5V to 5.5V DC (AC/DC adapter in option.
1065Supply, installation, testing and commissioning of Full range 4-inch or better IP55 rated surface mounted music loudspeaker. The loudspeaker shall meet the following performance criteria: Frequency range (-10dB) of 70Hz to 19kHz; Power handling of 160 Watt peak; Nominal dispersion of 90°(H) × 80°(V); Sensitivity of 87 dB SPL and Max SPL of 109 dB SPL peak or better; Nominal impedance of 8 ohms and Integral multi-tap Transformer with selectable tap settings of 5/10/20/40W@70V & 100V. The loudspeaker system shall be enclosed in engineered-plastics and a powder-coated steel grille. UL-1480 rated and EN54-24 compliant for Life safety/VA applications.
1066Loudspeaker: Supply, installation, testing and commissioning of IP55 Rated for Indoor and Outdoor installations, Full range drivers (8 or better) in an articulated Array design. Minimum eight 4.5” full-range cone transducers or better. Frequency Range (-10db) of 52 Hz - 15 kHz or better; Continuous power (AES) : 300W & Peak Power (AES) : 1200W @ 8 Ohms or better; Nominal dispersion of 120H X 100V or better; Sensitivity of 91 dB or better; Max SPL Peak of 121 dB or better; Powder coated steel grille.
1067Customise bracket for mounting speaker on site .
1068Supply , installation , testing and commissioning of full range 2.25-inch or better ceiling mounted music and PA loudspeaker. The loudspeaker shall meet the following performance criteria: Usable Frequency range (-10 dB) of 85Hz to 17kHz or better; Power handling of 64 Watt peak or more; Nominal dispersion of >=130° Conical or better; Sensitivity of 84 dB SPL or better and Peak SPL of 102 dB SPL or better; Nominal impedance of 16 ohms and Integral multi-tap Transformer with selectable tap settings of 2/4/7.5/15W@70V & 100V or better. The loudspeaker shall be enclosed in engineered-plastics with integrated steel back can and a powder-coated steel grille. UL-1480 rated and EN54-24 compliant for Life safety/VA applications.
1069Supply , installation , testing and commissioning of In ground Full range (Landscape) Music Loudspeaker: Free field Frequency range (-10dB) of 60Hz to 18kHz; Power handling of 320 Watt peak; Nominal dispersion of 360x50 or better; Free field Sensitivity of 87dB SPL and Max SPL of 106 dB SPL (peak); Integral multi-tap Transformer with tap settings of 20/40/80 W @ 100V. with weather proof green enclosure.
1070SITC of Class D configurable amplifier with total 2 x 1000W output power or better across 2 outputs, 4/8ohms, 70/100 Volt or mixed use operation; Frequency Response : 20Hz - 20kHz for LZ mode ;THD <0.04% at rated output
1071SITC of Class D configurable amplifier with total 4 x 300W / 2 x 600W output power or better @ 4/8ohms, 70/100 Volt or mixed use operation; Frequency Response : 20Hz - 20kHz for LZ mode ;THD <0.04% at rated output complete with standard accessories as required.
1072SITC of Digital Audio Conferencing Processor with at least 12 Mic/Line inputs & 8 analogy outputs, 24 Bit A-D and D-A Convertors; Sampling Rate : 48 kHz; THD : < 0.002 % ; Channel Separation (Crosstalk) : < 108 dB ; Frequency Response 20 Hz - 20 kHz ; Signal-to-Noise Ratio 90 dB ;Dynamic Range > 115 dB; 5 Control Inputs and Outputs; RS-232 and Ethernet Port for third party Control and Monitoring; 32X32 or more Bidirectional DANTE Audio Networking ports, Shall include USB Audio as standard Feature. inbuilt DSP features like Conference room Routers, Input Equalizers, Router, Band Pass filter, Output Equalizer, Delay, Limiters, gates , Source selectors etc. Shall Support at least 15 remote Zone controllers
1073Supply, installation, testing & Commissioning of programmable Audio DSP controller with Display and programmable encoder knobs. Multiple programmable settings configurable over Ethernet. Source Selection and Volume Controls ; Supports Up to 256 programmable Functions Shall include any accessory to make the system functional. etc. complete spec & no. as diercted by engg incharge.
1074Supply , installation , testing and commissioning of Music Player for BGM etc. complete spec & no. as diercted by engg incharge.
1075Supply , installation , testing and commissioning of Paging Mic etc. complete spec & no. as diercted by engg incharge.
1076SITC of 2 core Twisted, shielded balanced Audio and control cable with 20AWG or better 7 strand annealed bare copper conductors, Semi-Rigid PVC insulation, Riser rated PVC jacket. UL 444, UL 13 CMR rated etc. complete spec & no. as diercted by engg incharge.
1077Supply , installation , testing and commissioning of 2.5 Sq.mm. armoured speaker cable etc. complete spec & no. as diercted by engg incharge.
1078Supply , installation , testing and commissioning of CAT6A armoured cable etc. complete spec & no. as diercted by engg incharge.
1079Supply , installation , testing and commissioning of Media player PC, with KM etc. complete spec & no. as diercted by engg incharge.
1080Supply , installation , testing and commissioning of Connector for interconnectivity etc. complete spec & no. as diercted by engg incharge.
1081Supply , installation , testing and commissioning of Conduiting and casing etc. complete spec & no. as diercted by engg incharge.
1082Sub Work C : Fire FightingProviding Fire Fighting System for Proposed Construction of Marathwada Mukti Sangram Smarak Building At Chhatrapati Sambhajinagar
1083Carrying out core cutting of size 3\\" to 5\\" dia x 15\\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. (For quantities more than 30, reduce overall rate by 30%.)
1084Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1085Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1086Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 100 mm height comprising all required standard accessories.
1087\\"Supplying, installation, testing and commissioning of main fire pump (MFP/EP) suitable for water discharge of 2850 LPM at 145 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 112 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal type, single/multi stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/MSC/EP\\"
1088Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 140 to 110 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 15 kW or of suitable kW capacity for manual/automatic operation and consisting of following:(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Suitable kW Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP
1089Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
1090Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by 110 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
1091Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat ofprimer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connectionshaving switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in allrespect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working +1standby) with necessary accessories, wiring &cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications
1092the capacity of electric motor driven pump are as followsa. Main fire pump(MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessaryaccessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitableratings etc.3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating.
10934. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch. 5. TPN SPD 100kA Type 1 +2 tested.6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps. 7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch &alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification.8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications.9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge.10. Danger board as per IS.11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP = (1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECP
1094For addition of capacity of main electric motor driven fire pump MFP (1 working) for hydrant system is more than 22kW, add as follows in the basic cost of Item no 13-5-1 towards increased capacity switchgears and motor starters for main & jockey pumps along with necessary accessories for main & jockey fire pumps MFP= (1working), JP = (1working + 1standby, alternate run per start in auto mode)
1095For main electric motor driven fire hydrant system pump of 112 kW capacity & relevant capacity jockey pump add Rs….
1096For addition of booster pump for fire hydrant/sprinkler, add as follows in the basic cost of item no 13-5-1 towards necessary accessories, indicators etc. with necessary interlocking and updation of control logic, add Rs........ 1) for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) , add Rs
1097For addition of standby main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode) & jockey fire pumps (1working+1standby, alternate run per start in auto mode) , add Rs....... The control for diesel engine comprises of automatic/ manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps.
1098Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP
1099Supplying and erecting G.I. pipe ‘C’ class ERW 32 mm dia with necessary fittings complete as per specification no. FF-PP
1100Supplying and erecting G.I. pipe ‘C’ class ERW 40 mm dia with necessary fittings complete as per specification no. FF-PP
1101Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP
1102Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP
1103Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
1104Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
1105Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
1106Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP
1107Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
1108Supplying and erecting 80 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV (jockey-1)
1109Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV (1 for Diesel and 1 for Main pump)
1110Supplying and erecting 75/80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS (Jockey-1, Booster-1)
1111Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
1112Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV (Sprinkler system)
1113Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV (Sprinkler system)
1114Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
1115Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
1116Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
1117Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
1118Supplying and installing one piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessoriescomplete as per specification no. FF-FFA/PT
1119Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
1120Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specificationno. FF-FFA/RRL
1121Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF
1122Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
1123Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT
1124Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
1125Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
1126Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
1127Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8\\"x6\\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
1128Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU (111=2% for FRLS)
1129Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 8 loop capacity & capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-
1130Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300μA and alarmcondition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/ SD .
1131Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/ less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
1132Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \\"Break Glass\\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP
1133Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
1134Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
1135Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipmentreplacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
1136Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
1137Supplying, installing, testing and commissioning of digital linear heat detection cable addressable through monitor module with temperature ratings such as 60°-70°C, conforming to IS 2189: 2008, EN 54 or UL listed FF-AFAS/LHDC
1138Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½\\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF
1139Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg.capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
1140Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).
1141Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete.. (180x0.5x0.5)
1142Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
1143Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC
1144Supplying, erecting, testing and commissioning stand mounted/ handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC
1145Supplying, erecting, testing and commissioning of 1.00 sq. mm speaker wire complete.
1146Providing and fixing in position high pressure Flexible pipe for fixing the spriklers of required length upro 1.5 m including cutting fixing with necessary fitting like reducers, barrles, T-brackets, metal stud, gasket, isolating ring, nuts and bolts and other fixtures and fastneres ets.
1147Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. (Reference Taken from TS No: T-128/CE, 2025-26 Letter No 248/2026 Dt: 26/02/2026. Providing EI & Fire work to 300 Beded Hospital Building at Talegaon Dist Wardha) (SE Letter No. 433/2026 Dt: 15.02.2026)
1148Supplying & erecting Mechanical Foam fire extinguisher of 9 ltr. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete. (Reference Taken from TS No: T-128/CE, 2025-26 Letter No 248/2026 Dt: 26/02/2026. Providing EI & Fire work to 300 Beded Hospital Building at Talegaon Dist Wardha) (SE Letter No. 433/2026 Dt: 15.02.2026)
1149Supplying, installing, testing and commissioning of Fire Exit Sinages Acralic sheet with autoglow sinages of sizes 300 x 150mm with complete accessories. (Reference Taken from TS No: T-128/CE, 2025-26 Letter No 248/2026 Dt: 26/02/2026. Providing EI & Fire work to 300 Beded Hospital Building at Talegaon Dist Wardha) (SE Letter No. 433/2026 Dt: 15.02.2026)
1150Sub Work D : LiftProviding 13 passanger Lift,(3 Nos) for Proposed Construction of Marathwada Mukti Sangram Smarak Building At Chhatrapati Sambhajinagar
1151Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. (15 mtr for 1 Lift)
1152Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit /trunking /inside pole/Bus bars or any other places as per specification No: WG-MA/BW (for 1 Lift- Lift Room- 8 mtr)
1153Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking /inside pole/Bus bars or any other places as per specification No: WG-MA/BW (for 1 Lift- Lift Room- 7 mtr)
1154Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (for 1 Lift- shaft- 15 mtr)
1155Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places. as per specification No: WG-MA/BW (for 1 Lift- shaft- 25 mtr)
1156Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. (shaft- (bulkhead-1 & socket-1)x 3 )
1157Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. (shaft - 3 )
1158Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. (Lift Room- 1 x 1= 1 x 1=3 = 1=3)
1159Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
1160Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected.
1161Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected
1162Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW (Lift room-3 no)
1163Wiring for plug on board with Switch socket surface/ concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW /CW (Lift Room- 1)
1164Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. (Shaft 3 = 3 x 12= 36)
1165Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB (Lifr Romm power-1)
1166Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB (shaft Lighting-1, Romm SB-1)
1167Providing, erecting and commissioning 2 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 16/ 25A complete as per specification no. SW-RCCB/RCCB (Lift Room 4-SPN enclosure)
1168Supplying & erecting CRCA sheet metal one way enclosures suitable for DP MCB /TP MCB /FP MCBerected on angle iron/GI frame complete. (4P RCCB-1, 2P RCCB+2SP MCB-1) (2 x 2=4)
1169Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
1170Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
1171Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1172Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1173Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
1174Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall /cable /conduit with screws complete. (8 SWG Tar- 0.116 kg / mtr - 20 Mtr x 0.116 Kg/Mtr = 2.32 Kg x 1 Lifts)
1175SITC of Electric Traction Passenger cum Lift with
1176Rated capacity :- 13 Passenger/884Kg
1177· Floors :- G+8 floor (9Stops/9 Landings)
1178· Travel :- 62.4 mtrs
1179· Location of Lift Machine:- MR/MRL
1180· Rated speed :- 1.75mps VS
1181Car/Landing door clear opening of 1000 mm wide x 2000mm high
1182Clear Car size of .1100mm wide x 2000mm deep x 2250mm high
1183Lift shaft available having clear size of 1800 mm wide x 2200 mm deep, 1800mm Pit depth, 5100 mm Overhead.
1184Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).
1185· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge.
1186· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor
1187· LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings
1188· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation
1189operation, earthquake operation, door open/closeoperation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCDscreen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provisionfor addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.
1190· ARD complete with necessary SMF VRLA batteries
1191· Fireman controller having fireman switch at fire Landing,
1192· CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimedon Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days min. with 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge
1193· Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.
1194· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work
1195· Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc completewith plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.
1196General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.
1197The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.
1198For Lift having 1000mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope, landing doors with all accessories etc. complete for the safe functioning of lift installation.
1199SITC of Triplex Lift control system for three nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication /control/data cabling laying in rigid PVC conduits/trunking etc. complete..
1200For Lift travelling above First floor & up to Eight floor
1201Sub Work E : Immersive TechProviding Immersive System for Proposed Construction of Marathwada Mukti Sangram Smarak Building At Chhatrapati Sambhajinagar
1202Supplying, erecting, testing and commissioning of all-in-one wireless headset audio guide unit with integrated high-quality audio output, offering hands-free automatic content triggering via Infrared (IR), 2.4GHz Radio Frequency (RF) and Radio Frequency Identification (RFID) technologies, with location-based triggering accuracy of approximately 10cm. Onboard non-volatile storage: minimum 16GB, supporting audio formats WAV/MP3/AAC/M4A/OGG, loadable via USB/SD card. Unit shall support programming and playback of minimum 3 languages (expandable up to 32 languages/tour versions). Battery: rechargeable, minimum two (2) days continuous operating autonomy per full charge, with fast-charge capability (up to 80% in approx. 2 hours) via magnetic charging contacts compatible with modular 20-unit charging racks (Item 6). Body of rugged, impact-resistant polycarbonate construction, operable in ambient temperature -10°C to +50°C, up to 96% relative humidity. Unit shall support auto-synchronisation with external multimedia equipment (video, interactive displays, lighting, show controllers) via IR/RF triggering. Body dimensions/weight: approx. 160 x 170 x 30mm (approx. 70g) or 160 x 170 x 55mm (approx. 118g), variant dependent. Complete with all standard accessories as required.
1203Supplying, erecting, testing and commissioning of Digital 2.4GHz Tour-Guide Transmitter having the following technical specifications:Triggering modes: Point & Click, Buzz & Play, IR, RF, RFID, keypad and manual; operating frequency 2.4GHz digital; channel/group capacity up to 20/40 parallel channels/groups, minimum 7 required; 1.7 inch colour display; onboard storage not less than 16GB; audio output via standard 3.5mm jack; language capacity up to 32 languages/tour versions; rechargeable battery providing minimum 100 hours continuous operating autonomy per full charge; operating temperature range -10°C to +50°C; overall dimensions/weight 155 x 58 x 18mm, 150g; accessibility features including visually-impaired keypad navigation, induction loop and Braille keypad support.Complete as per direction and to the entire satisfaction of the Engineer-in-Charge, with comprehensive on-site warranty for a minimum period of 5 (five) years from the date of successful commissioning.
1204Supplying, erecting, testing and commissioning of Group-Leader Microphone (for use with Item 2) having the following technical specifications:Channel capacity of 20 selectable transmission channels/codes; group transmission range of 10-15m, field-adjustable; individual/close-range transmission mode of 10-50cm, field-adjustable; each range independently adjustable across 18 discrete power levels (0-17); automatic mute/squelch function suppressing transmission when the group leader is not speaking, to minimise ambient noise pick-up and feedback; field-adjustable microphone gain.Complete as per direction and to the entire satisfaction of the Engineer-in-Charge, with comprehensive on-site warranty for a minimum period of 5 (five) years from the date of successful commissioning.
1205Supplying, erecting, testing and commissioning of Headset Fitting Adapter (for use with Item 1) having the following technical specifications:Ear-cushion/fitting adapter enabling secure and comfortable fit of the headset across all head sizes, including smaller head sizes for children, without direct ear-canal contact (hygienic, contactless design); skin-safe, easily cleanable and replaceable padding material, fully compatible with the headset unit supplied at Item 1.Complete as per direction and to the entire satisfaction of the Engineer-in-Charge, with comprehensive on-site warranty for a minimum period of 5 (five) years from the date of successful commissioning.
1206Supplying, erecting, testing and commissioning of Individual Docking Station (for Item 1 unit) having the following technical specifications:Single-unit docking station providing battery charging, statistics/data upload and content re-programming of the headset audio guide unit (Item 1) via a single multi-purpose docking interface; overall dimensions 20.5 x 14.5 x 5cm.Complete as per direction and to the entire satisfaction of the Engineer-in-Charge, with comprehensive on-site warranty for a minimum period of 5 (five) years from the date of successful commissioning.
1207Supplying, erecting, testing and commissioning of 20-Unit Battery and Data Charging Rack (for Item 1 units) having the following technical specifications:Modular rack/cabinet providing simultaneous magnetic-contact charging for 20 nos. headset audio guide units, with USB-based data transfer to host PC for content programming and usage-statistics retrieval; power supply 110-220V AC, approx. 200W rated consumption; overall dimensions 66 x 23 x 46cm; weight approx. 8kg; stackable/modular construction for scalable deployment.Complete as per direction and to the entire satisfaction of the Engineer-in-Charge, with comprehensive on-site warranty for a minimum period of 5 (five) years from the date of successful commissioning.
1208Supplying, erecting, testing and commissioning of All-in Multimedia Easy-Synchro Emitter having the following technical specifications:Triggering modes: Point & Click, automatic IR, automatic 2.4GHz RF and RFID; fitted with General Purpose Input/Output (GPIO) ports, both input and output, for interfacing with third-party AV/show-control equipment; power supply 110-220V AC; overall dimensions 100 x 97 x 40.5mm; compatible with the full range of audio guide headsets/transmitters supplied under this contract. Complete as per direction and to the entire satisfaction of the Engineer-in-Charge, with comprehensive on-site warranty for a minimum period of 5 (five) years from the date of successful commissioning.
1209Supplying, erecting, testing and commissioning of Compact IR radiator used for the Auto IR function. Used in combination with the emitters ref 5ZONEIR AG/ LK, TARGET AG, and SYNCH AG/ LK. Dimensions/ 63 (open position) x 25 (dia.) mm. Used for all Look audio guides and for Look tablet. Coverage: 90° angle, 15 meters.
1210Supplying, erecting, testing and commissioning of All-in emitter box for one auto IR triggering zone with adjustable emission power. AC power supply 110-220 V. 90° angle, 15 m.Three different IR LED power options: 30°/ 5 m, 60°/ 5 m, and 90°/ 15 m. Dimensions 65 dia. x 75 mm.
1211Supplying, erecting, testing and commissioning of All-in auto IR and RFID emitter. Runs on 110-220 v power supply. Easy installation box, and a printable/ customizable target cover. Dimensions 128 x 75 x 20 mm. Used for all Look audio guides and for Look tablet. Box without cover.
1212Supplying, erecting, testing and commissioning of All-in auto IR and RFID emitter. Runs on 110-220 v power supply.Easy installation box, and a printable/ customizable target cover. Dimensions 128 x 75 x 20 mm. Used for all Look audio guides and for Look tablet. USED FOR ALARM NEXT TO EXIT DOOR.
1213Supplying, erecting, testing and commissioning of Smart alarm system that alerts front desk. Used in combination with AUTO LK AG emitters. Adjustable volume and alarm sound. AC power supply 110-220 V. Dimensions: 20.5 x 14.5 x 5 cm; Weight 1.13 kg. USED FOR ALARM NEXT TO DESK.
1214Supplying, erecting, testing and commissioning of Language Set-Up System having the following technical specifications:Rapid language/tour-version configuration system for bulk (re)programming of audio guide headset units via Infrared (IR) and Radio Frequency (RF) technology; configuration capacity of up to 40 compatible devices simultaneously, at approx. 1 second per device; up to 20 field-programmable function buttons (language, tour version, custom/children's tour and channel selection); 5.5 inch integrated display; external dimensions 40 x 30 x 32cm; internal chamber dimensions 40 x 30 x 26cm; compatible with the full range of audio guide headsets/transmitters supplied under this contract.Complete as per direction and to the entire satisfaction of the Engineer-in-Charge, with comprehensive on-site warranty for a minimum period of 5 (five) years from the date of successful commissioning.
1215Supplying, erecting, testing and commissioning of Professional UV-C Sanitizing System having the following technical specifications:Rated efficacy not less than 99% against bacteria and viruses, including SARS-CoV-2 (COVID-19); fully enclosed reflective sanitising chamber with two-tier acrylic shelf/tray arrangement, capacity up to 49 audio guide units per cycle; safety interlock ensuring the UV-C lamp activates only when the chamber is fully closed; UV-C lamp of minimum 8W rated power, 253.7nm wavelength, minimum rated lamp life 9,000 hours, delivering a minimum UV dose of approx. 186,000 microwatt-seconds/cm² per standard cycle; standard recommended cycle time of 5 to 10 minutes, field-adjustable up to 30 minutes; overall dimensions 60.5 x 35.5 x 30.5cm; weight 11.5kg; dual-mode power supply - 100-240V AC or USB-C (5V/3A) DC - with internal rechargeable lithium-ion battery of minimum 40,000mAh (148Wh) capacity, providing full-day operating autonomy; unit shall carry CE and FCC certification, with external LED status indicator for cycle status.Complete as per direction and to the entire satisfaction of the Engineer-in-Charge, with comprehensive on-site warranty for a minimum period of 5 (five) years from the date of successful commissioning.
1216Supplying and commissioning of Annual Maintenance Contract (AMC) for the audio guide fleet-management and usage-statistics software platform (associated with the Statdock hardware interface used with Items 5 and 6) having the following scope:Software licensing, updates and technical support for collection, upload and reporting of audio guide usage/visit statistics via the manufacturer's statistics dashboard/portal, for a contract period of one (1) year per unit charged.Complete as per direction and to the entire satisfaction of the Engineer-in-Charge.
1217Video Wall
1218Supplying, erecting, testing and commissioning of an indoor flexible/curved Active LED Screen for the 360° immersive theatre, of size approximately 39m x 4m (diagonal approximately 1543 inches), configured as a continuous curved wrap conforming to the theatre's circular geometry, with curvature radius as per the Architect's approved theatre plan. The screen shall be of below or equal 2mm (P27) pixel pitch, comprising cabinets of 500mm x 500mm x 87mm size arranged in a 78 (W) x 8 (H) matrix, giving a wall resolution of 13,448 x 1,379 pixels. Cabinets shall be die-cast aluminium construction weighing approximately 8 kg each, with front-service access and magnetic suction mounting onto the structural steel framework. Brightness shall be field-adjustable across a wide dimming range of minimum 10–800 cd/m² to suit darkened theatre ambient conditions, with a minimum refresh rate of 3840Hz for flicker-free, camera-safe playback, and a minimum viewing angle of H140°/V140°. The display shall be rated IP31 for indoor use, suitable for operating conditions of 0–50°C and 10–90% RH, and shall be of curved/flexible module construction capable of concave and convex cylindrical installation without visible seams. The item shall be complete with control card and power supply, as directed by the Engineer-in-Charge. On Site Warrenty 5 years.
1219Supplying, installing, testing and commissioning of a 4K-capable LED video wall controller/processor for the screen at Sr. No. 1, complete with sending and receiving cards, control PC interfacing, cabling and control/content management software licence. The controller shall support HDMI 2.0 / DisplayPort / SDI / IP-streaming input up to native 4K resolution and above, with not less than 16-bit colour processing, dual-redundant power and signal loop backup, multi-source input with seamless switching, and multi-window/layout management, sized to the wall resolution of 19,500 x 2,000 pixels, rack-mounted/cabinet-housed at the designated control room location, complete as directed by the Engineer-in-Charge. On Site Warrenty 5 years.
1220Design, fabrication, supply, erection, testing and commissioning of a site-customised supporting structure for the LED wall at Sr. No. 1, sized to receive a 78 (W) x 8 (H) matrix of 500mm x 500mm cabinets over an overall area of approximately 39m x 4m. The structure shall be fabricated of Mild Steel (MS) or Galvanised Iron (GI) sections (angles, channels, box/square tubes), shop-primed and powder-coated, designed with adequate safety factor to carry the full dead load of the cabinets (approx. 9–10 kg/cabinet plus cabling and service margin) together with wind/seismic loads applicable to the location, with adjustable mounting brackets for cabinet alignment, integrated cable trays for concealed cabling, and suitable foundation anchors/fasteners for secure fixing to the building structure, complete in all respects as directed by the Engineer-in-Charge. On Site Warrenty 5 years.
1221Supplying, erecting, testing and commissioning of an indoor LED video wall of overall size approximately 11.48 ft (W) x 6.56 ft (H) [3.5m x 2.0m], built up from die-cast aluminium cabinets of size 500mm x 500mm x 87mm arranged in a matrix of 7 (W) x 4 (H) cabinets, to achieve a wall resolution of 1,750 x 1,000 pixels at a pixel pitch of 2.0mm. Each cabinet shall house full-colour RGB SMD LED modules, offering a minimum brightness of 800–1000 cd/sq.m, viewing angle of not less than 140° horizontal and 140° vertical, refresh rate of not less than 3,840Hz, frame rate of 50/60Hz, and contrast ratio of not less than 5,000:1. Average and maximum power consumption shall not exceed 350 W/sq.m and 850 W/sq.m respectively, at input voltage AC 110–220V, 50/60Hz. Cabinets shall be of total front-access design, weighing approximately 9–10 kg each, rated for a minimum life of 1,00,000 hours at 50% brightness, operable within 0°C to 50°C and 10–90% RH indoor ambient conditions, and compliant with CE/BIS/CCC/FCC/CB standards, complete in all respects. On Site Warrenty 5 years.
1222Supplying, installing, testing and commissioning of a standard-tier LED video wall controller/processor for each screen at Sr. No. 4, complete with sending and receiving cards, control PC interfacing, cabling and control/content management software licence. The controller shall support HDMI / DVI / VGA / SDI input as required up to the screen's native resolution of 1,750 x 1,000 pixels, with not less than 14-bit colour processing and loop-backup/hot-swap redundancy as warranted by site criticality, rack-mounted/cabinet-housed at the designated control location, complete as directed by the Engineer-in-Charge. On Site Warrenty 5 years.
1223Design, fabrication, supply, erection, testing and commissioning of a site-customised supporting structure for each LED wall at Sr. No. 4, sized to receive a 7 (W) x 4 (H) matrix of 500mm x 500mm cabinets over an overall area of approximately 3.5m x 2.0m. The structure shall be fabricated of MS/GI sections, shop-primed and powder-coated, designed with adequate safety factor to carry the full dead load of the cabinets plus cabling and service margin, with adjustable mounting brackets, integrated cable trays, and suitable anchors/fasteners for secure fixing, complete in all respects as directed by the Engineer-in-Charge. On Site Warrenty 5 years.
1224Supplying, erecting, testing and commissioning of an indoor LED video wall immersive experiantial tunnel of overall size approximately 28m (W) x 3m (H), built up from die-cast aluminium cabinets of size 500mm x 500mm x 87mm arranged in a matrix of 56 (W) x 6 (H) cabinets, to achieve a wall resolution of 14,000 x 1,500 pixels at a pixel pitch of 2.0mm. Each cabinet shall house full-colour RGB SMD LED modules, offering a minimum brightness of 800–1000 cd/sq.m, viewing angle of not less than 140° horizontal and 140° vertical, refresh rate of not less than 3,840Hz, frame rate of 50/60Hz, and contrast ratio of not less than 5,000:1. Average and maximum power consumption shall not exceed 350 W/sq.m and 850 W/sq.m respectively, at input voltage AC 110–220V, 50/60Hz. Cabinets shall be of total front-access design, weighing approximately 9–10 kg each, rated for a minimum life of 1,00,000 hours at 50% brightness, operable within 0°C to 50°C and 10–90% RH, and compliant with CE/BIS/CCC/FCC/CB standards, complete in all respects. On Site Warrenty 5 years.
1225Supplying, installing, testing and commissioning of a 4K-capable LED video wall controller/processor for the screen at Sr. No. 7, complete with sending and receiving cards, control PC interfacing, cabling and control/content management software licence. The controller shall support HDMI 2.0 / DisplayPort / SDI / IP-streaming input up to native 4K resolution and above, with not less than 16-bit colour processing, dual-redundant power and signal loop backup, multi-source input with seamless switching, and multi-window/layout management, sized to the wall resolution of 14,000 x 1,500 pixels, rack-mounted/cabinet-housed at the designated control room location, complete as directed by the Engineer-in-Charge. On Site Warrenty 5 years.
1226Design, fabrication, supply, erection, testing and commissioning of a site-customised supporting structure for the LED wall at Sr. No. 7, sized to receive a 56 (W) x 6 (H) matrix of 500mm x 500mm cabinets over an overall area of approximately 28m x 3m. The structure shall be fabricated of MS/GI sections, shop-primed and powder-coated, designed with adequate safety factor to carry the full dead load of the cabinets plus cabling and service margin together with applicable wind/seismic loads, with adjustable mounting brackets, integrated cable trays, and suitable anchors/fasteners for secure fixing, complete in all respects as directed by the Engineer-in-Charge. On Site Warrenty 5 years.
1227Supplying, erecting, testing and commissioning of an indoor LED video wall for immersive experiantial tunnel of overall size approximately 17m (W) x 3m (H), built up from die-cast aluminium cabinets of size 500mm x 500mm x 87mm arranged in a matrix of 34 (W) x 6 (H) cabinets, to achieve a wall resolution of 8,500 x 1,500 pixels at a pixel pitch of 2.0mm. Each cabinet shall house full-colour RGB SMD LED modules, offering a minimum brightness of 800–1000 cd/sq.m, viewing angle of not less than 140° horizontal and 140° vertical, refresh rate of not less than 3,840Hz, frame rate of 50/60Hz, and contrast ratio of not less than 5,000:1. Average and maximum power consumption shall not exceed 350 W/sq.m and 850 W/sq.m respectively, at input voltage AC 110–220V, 50/60Hz. Cabinets shall be of total front-access design, weighing approximately 9–10 kg each, rated for a minimum life of 1,00,000 hours at 50% brightness, operable within 0°C to 50°C and 10–90% RH, and compliant with CE/BIS/CCC/FCC/CB standards, complete in all respects. On Site Warrenty 5 years.
1228Supplying, installing, testing and commissioning of a standard-tier LED video wall controller/processor for the screen at Sr. No. 10, complete with sending and receiving cards, control PC interfacing, cabling and control/content management software licence. The controller shall support HDMI / DVI / VGA / SDI input as required up to the screen's native resolution of 8,500 x 1,500 pixels, with not less than 14-bit colour processing and loop-backup/hot-swap redundancy as warranted by site criticality, rack-mounted/cabinet-housed at the designated control location, complete as directed by the Engineer-in-Charge.On Site Warrenty 5 years.
1229Design, fabrication, supply, erection, testing and commissioning of a site-customised supporting structure for the LED wall at Sr. No. 10, sized to receive a 34 (W) x 6 (H) matrix of 500mm x 500mm cabinets over an overall area of approximately 17m x 3m. The structure shall be fabricated of MS/GI sections, shop-primed and powder-coated, designed with adequate safety factor to carry the full dead load of the cabinets plus cabling and service margin, with adjustable mounting brackets, integrated cable trays, and suitable anchors/fasteners for secure fixing, complete in all respects as directed by the Engineer-in-Charge. On Site Warrenty 5 years.
1230Supplying, erecting, testing and commissioning of an indoor LED video wall of overall size approximately 5.5m (W) x 3m (H), built up from die-cast aluminium cabinets of size 500mm x 500mm x 87mm arranged in a matrix of 11 (W) x 6 (H) cabinets, to achieve a wall resolution of 2,750 x 1,500 pixels at a pixel pitch of 2.0mm. Each cabinet shall house full-colour RGB SMD LED modules, offering a minimum brightness of 800–1000 cd/sq.m, viewing angle of not less than 140° horizontal and 140° vertical, refresh rate of not less than 3,840Hz, frame rate of 50/60Hz, and contrast ratio of not less than 5,000:1. Average and maximum power consumption shall not exceed 350 W/sq.m and 850 W/sq.m respectively, at input voltage AC 110–220V, 50/60Hz. Cabinets shall be of total front-access design, weighing approximately 9–10 kg each, rated for a minimum life of 1,00,000 hours at 50% brightness, operable within 0°C to 50°C and 10–90% RH, and compliant with CE/BIS/CCC/FCC/CB standards, complete in all respects. On Site Warrenty 5 years.
1231Supplying, installing, testing and commissioning of a standard-tier LED video wall controller/processor for each screen at Sr. No. 13, complete with sending and receiving cards, control PC interfacing, cabling and control/content management software licence. The controller shall support HDMI / DVI / VGA / SDI input as required up to the screen's native resolution of 2,750 x 1,500 pixels, with not less than 14-bit colour processing and loop-backup/hot-swap redundancy as warranted by site criticality, rack-mounted/cabinet-housed at the designated control location, complete as directed by the Engineer-in-Charge. On Site Warrenty 5 years.
1232Design, fabrication, supply, erection, testing and commissioning of a site-customised supporting structure for each LED wall at Sr. No. 13, sized to receive an 11 (W) x 6 (H) matrix of 500mm x 500mm cabinets over an overall area of approximately 5.5m x 3m. The structure shall be fabricated of MS/GI sections, shop-primed and powder-coated, designed with adequate safety factor to carry the full dead load of the cabinets plus cabling and service margin, with adjustable mounting brackets, integrated cable trays, and suitable anchors/fasteners for secure fixing, complete in all respects as directed by the Engineer-in-Charge. On Site Warrenty 5 years.
1233Sub Work F : Air ConditioningProviding HVAC System for Proposed Construction of Marathwada Mukti Sangram Smarak Building At Chhatrapati Sambhajinagar
1234Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
1235Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
1236Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
1237Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for AC unit.
1238Supplying, erecting, testing and commissioning of 20HP, VRF/VRV air conditioning system out door unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56°C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
1239Supplying, erecting, testing and commissioning of 22HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/ digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
1240Supplying, erecting, testing and commissioning of 24HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/ digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
1241Supplying, erecting, testing and commissioning of 28HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/ digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
1242Supply, installation, testing and commissioning air curtain of 6 feet width having air throw velocity of 21 m/sec, low noise level up to 38 to 46dBA suitable for door height upto 9 feet, working on 1 phase, 230V, 50Hz, A.C.
1243Supply, fabrication, installation and testing of flexible canvas connections constructed between ductable unit/dampers/ducting of suitable size with fire resist flexible double canvas sleeve complete.
1244Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC-2017
1245Supplying and installation of high pressure grade required size copper connection Y or T- Joints/refnut complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation,painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system.
1246Supplying and installing of collar damper of galvanised iron material of upto120 microns for anti corrosive resistance for supply air grill of suitable size.
1247Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°.
1248supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
1249supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
1250supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
1251supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
1252supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
1253supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
1254supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
1255supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4mm dia (OD)for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
1256Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
1257Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
1258Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
1259Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 500 mm width & 20 mm height complete with necessary hardware.
1260Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
1261Supply, installation, testing and commissioning of factory built Floor mounted double skin type Air Handling Units with thermal break profile made of 43 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8 mm outside layer and 0.8 mm plane inside layer with polyurethene foam (PUF) insulation of density 32 kg/m3 factory injected between them by injection moulding machine, complete with blower section with blower DIDW backward curved centrifugal fan/plug type fan of , 6 row deep cooling coil, section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type inlet EU-4 &,plug fan with TEFC drive motor suitable for 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, complete with mixing box, drain connections with drain valve, drain pan, necessary vibration isolation arrangement etc, With AHU accessories like expansion valve, drier, PCB, liquid valve, hand shut off valve, flare nut/AHU kit for VRF ODU etc with Cordless /Corded remote control & VFD.The Air Handling Unit Shall have necessary drive set.complete as per specifications of following capacities:
126228000 CFM @ 80mm (Ground Floor) In 21.8 deg.C DB / 16.8 deg.C WB Out 11.1 deg.C DB / 10.7 deg.C WB
126320000 CFM @ 80mm (First Floor) In 21.8 deg.C DB / 16.8 deg.C WB Out 11.1 deg.C DB / 10.7 deg.C WB
126416500 CFM @ 80mm (Second Floor) In 21.8 deg.C DB / 16.8 deg.C WB Out 11.1 deg.C DB / 10.7 deg.C W
126516000 CFM @ 80mm (Third Floor) In 21.8 deg.C DB / 16.8 deg.C WB Out 11.1 deg.C DB / 10.7 deg.C WB
126614500 CFM @ 80mm (Fourth Floor) In 21.8 deg.C DB / 16.8 deg.C WB Out 11.1 deg.C DB / 10.7 deg.C WB
126712500 CFM @ 80mm (Fifth Floor) In 21.8 deg.C DB / 16.8 deg.C WB Out 11.1 deg.C DB / 10.7 deg.C WB
126812500 CFM @ 80mm (Sixth Floor) In 21.8 deg.C DB / 16.8 deg.C WB Out 11.1 deg.C DB / 10.7 deg.C WB
126913500 CFM @ 80mm (Seventh Floor) In 21.8 deg.C DB / 16.8 deg.C WB Out 11.1 deg.C DB / 10.7 deg.C WB
12709000 CFM @ 80mm (Eighth Floor)In 21.8 deg.C DB / 16.8 deg.C WB Out 11.1 deg.C DB / 10.7 deg.C WB
1271Est No 122048 / 2026-27 Providing CCTV System to Proposed Construction of Marathwada Mukti Sangram Building at Vishvas Nagar ,Labour Colony, at Chatrapati Sambhajinagar,Dist.Jalna.
1272Supplying and erecting 20mm dia. corrugated flexible polypropylene conduit
1273Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
1274Supplying and erecting PVC box trunking of size 50x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX.
1275Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1276Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1277Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
1278Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
1279Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
1280Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
1281Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
1282Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected.
1283Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module duly erected.
1284Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
1285Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, core dia 50/125 µm (OM3), suitable upto 10 GBPS, ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-COC/OFC LSZH
1286Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
1287Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete.
1288Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS
1289Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
1290Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
1291Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
1292Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
1293Supplying and fixing 42 U floor mount server rack (Dimension-DxWxH – 800x1000x2070 mm) as per specification No. WG-NAS/RAK
1294Supplying, erecting, testing and commissioning of 2kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
1295Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete
1296Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features 4/5 Megapixel Vandal Dome Camera . 1/2.7\\" or higher 4MP PS CMOS Image sensor.MAx.4MP ( 2688 x 1520 ) @ 25 fps or above / max. 5MP ( 2688 x 1620 ) @ 25 fps or above. Instastream H.264,H.264,H264H,H264B,MJPEG Support Quad Stream. WDR ( 120 dB),DAy/Night( ICR),3D NR,ROI,AWB,AGC,BLC,HLC,Digital watermarking support Built in Mic. IR Range of 30 Mtr or above ,Warm Light Range of 30mtr or above. 3.6 mm fixed lens ( 2.8mm,6mm Optional).Support starlight Technology. Micro SD card upto 256 GB supported,PoE,IP 67,IK10,ISO 9001:2015,ISo 20000-1 :2018,CE,FCC and RoHS,BIS,STQC ER Certificate,duly erected on wall/Cealing/provided pole with all accessories complete with 3 years warranty.
1297Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features 4/5 MP Bullet Camera . 1/2.7\\" or higher 4MP PS CMOS Image sensor.Max.4MP ( 2688 x 1520 ) @ 25 fps or above / max. 5MP ( 2688 x 1620 ) @ 25 fps or above. Instastream H.265,H.264,H264H,H264B,MJPEG Support Quad Stream. WDR ( 120 dB),Day/Night( ICR),3D NR,ROI,AWB,AGC,BLC,HLC,Digital watermarking . IR Range of 30 Mtr or above ,Warm Light Range of 30mtr or above. 3.6 mm fixed lens ( 2.8mm,6mm Optional).Support starlight Technology. Micro SD card upto 256 GB supported,PoE,IP 67,IK10,ISO 9001:2015,ISo 20000-1 :2018,CE,FCC and RoHS,BIS,STQC ER Certificate,duly erected on wall/Cealing/provided pole with all accessories complete with 3 years warranty.
1298Supplying, installing, testing & commissioning of 64 Ch Network Video Recorder 64Ch. 4K AI Network Video Recorder Up to 64 channel IP camera input Max. Decoding capability: 32 1080p@30fps Max. 320/384 Mbps Incoming/ Recording/ Outgoing bandwidth AI by Recorder: supports 8 channel face detection and recognition, up to 20 face databases and 200,000 face images, 8 channel metadata, 24 channel perimeter protection, 32 channel SMD Plus. AI by Camera: supports face detection and xecogrñtion, peñmeter protection, SMD Plus, metadata, ANPR, stereo analysis, heat map, and people countingSupport redundant power, RAID 0/1/5/6/10, N+M cluster Support 8 SATA HHDs up to 20TB Each, 4 USB Port2 HDMI / 2 YGA simultaneous video output RoHS, UL, CE, FCC certified.duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specificationss no. CCTV-NVR complete with3 years warranty.
1299Supplying & erecting of High definition 4/5 Megapixel IP IR PTZ Camera with following features4/5 MP WDR 32x IR Network PTZ Camera.1/2.8” ox higher 4MP PS CMOS Image sensorMax. 4MP (2688 x 1520)@25fps or above /Max. 5MP (2880x1620)@25fps or aboveInstastream, H.265, H.264, H.264B, H.264H, MJPEG Support Triple stream, Storage - SFTP, NAS, Mirco SD card (Upto 256GB) Powerful 32x Optical and 16x Digital zoomWDR(120dB), 2D NR/ 3D NR, Day/Night(ICR), ROI, Defog, AWB, BLC Up to 300 Presets, S Scan, 8 Tour, S Pattern
1300Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64,Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD complete with 3 years warranty.
1301Supplying & erecting 65\\" professional LED display with 1920 *1080 ( Full HD)Display, suitable for 64 channel NVR and following featuresBrightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1Viewing angle: 178/178 deg.Response time: maximum 8 msInputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W,Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand andwiring connections etc. complete as per specifications no. CCTV-Monitor
1302Sub Work H : Pumps, GenratorProviding DG Set and Water Pumps for Proposed Construction of Marathwada Mukti Sangram Smarak Building At Chhatrapati Sambhajinagar
1303Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match theswitchgears or as per directions by the authority.
1304Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. ( 3.5 Mtr X 2.0 Mtr X 0.3 Mtr)
1305Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete.
1306Supplying, erecting, testing and commissioning of diesel generating set with alternator of 500 kVA confirming to CPCB-IV plus Emission Compliant with output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f.A.C supply, a totally enclosed liquid cooled multi in line cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/-0. 5 %, with performance class G2 Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters,switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, with suitable capacity DEF tank provided with first filling of oil, diesel tank capacity not less than 230 Litres etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector if necessary. This D.G set is Fitted in Soundproof & Weather Proof Acoustic Enclosure as per CPCB IV plus Emission Compliant (with acoustic enclosure as per
1307Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 400 kVA up to 500 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF...(10% less) (Note: In case of new DG set, If AMF/SYNC panel is to be used inlieu of standard panel, reduce rate of Item No 11-2-1 to 11-2-23 by 10%of rate of new AMF panel/ SYNC panel.)
1308Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1309Supplying and laying (including excavation of suitable width & depth up to 90 cm) 160 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
1310Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
1311Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. (25x3 GI Strip - 30 Mtr x 0.59 Kg/Mtr = 17.7)
1312Supplying and erecting metal work in CRCA (14 SWG) sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
1313Supplying and erecting Iron, sheet metal work consisting of CRCA Sheets, Various sections of iron, Plates, Chequered Plates, Rods, Bars, MS pipes, etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority
1314Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP
1315Supplying, installing, testing and commissioning air circuit breaker manual drawout type, 650V, up to 800A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection), 50 kA (Ics=Icu=Icw for 1s),with standard accessories and with ready to close, individual fault trip, alarm and trip indication, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB (2 No for 2 Nos 5OOKVA DG SET incomer supply, 1 No for Bus Coupler)
1316Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable tooperate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. (1 No Transformer, 2 No for 2 DG)
1317Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. (1 No Transformer, 2 No for 2 DG)
1318Supplying and erecting LT current transformer with bar primary 50/5 to 2000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
1319Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
1320Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs.
1321Battery Charger- Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1322CONTROL MCB- Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1323Multifunction Meter: Supplying and erecting Intelligent flush mounted panel meter three phase four wire (IPM) input voltage measurement range 50-550 V AC (P-P) 415V, aux. supply 90-300 V AC/DC, flush mounted (96 x 96 mm) meter constant Wh viewing in LCD multifunction meters in auto scroll mode with voltage, current, frequency, power factor kW, kVA, kVAR, kWh, kVAh, kVARh, phase angle, interrupts, THD, complete with RS 485 communication protocol, class 1 accuracy and wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.
1324Aux. Contactor 2 NO + 2 NC
1325Synchronising Relay AGC 150
1326LVMR- Low Voltage Monitoring Relay
1327BATTRY CHARGER DC output range 24V / 48V / 110V / 220V / 360V — up to 800A Configuration FCBC | Dual FCBC | Float + FCBC Input supply 1-Phase 230V AC or 3-Phase 415V AC, 50Hz Phase 1Ph–1Ph | 3Ph–3Ph Converter technology 3-phase 6-pulse thyristor (SCR) | single-phase half-controlled SCR | 2-switch forward SMPS / IGBT Battery types supported Lithium-Ion, Lead-Acid, VRLA, Ni-C Control 40-pin microcontroller - auto float/boost selection, charge start/stop, fault sensing & alarm annunciation
1328Supplying and erecting 12V/200Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete
1329Supplying and erecting minimum Three & above star rated submersible pump set of 3.75 KW/5 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 60 to 290 LPM discharge at 112 to 12 m head & discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP (Boreweel-5 Nos)
1330Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP (1 running & 1 standby) (4 Nos Terrace Tank)
1331Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assemblycomplete.
1332Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .
1333Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1334Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
1335Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
1336Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete.
1337Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.
1338Supplying and erecting CI flange 50 mm. dia with necessary nuts bolts and washers with rubber seal in position complete.
1339Supplying & erecting four pole ON LOAD change over switch, 415V, 40A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying toIS/IEC 60947-3 Part-1/3. (for openwll pump, incase felure)
1340Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1341Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
1342Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only
1343Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and dulypowder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58265136
AUTHORITY Government Departments
TENDER VALUE 75.88 Crore
LAST DATE 13-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Marathwada Mukti Sangram Smarak And Immersive Technology At Taluka And District Chh.Sambhajinagar
Basic Detail
Tender No E TENDER NOTICE NO 98/01 FOR 2026-27
Bidding Type Tender
Location
City Aurangabad
State Maharashtra
Key Dates
Publish Date 29 Oct 2026
Submission Date 13 Nov 2026
Open Date 16 Nov 2026
Finance
Tender Value 75.88 Crore
Tender Fee 3540
EMD 37.95 Lakhs
Exemption Not Available
Document List
76b6e652-58c1-4708-8700-dad6f115abea.html
BOQ_2303168.xls
SrNo01ofTN98TENDER.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Nov 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

76b6e652-58c1-4708-8700-dad6f115abea.html

xls

BOQ_2303168.xls

pdf

SrNo01ofTN98TENDER.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender