Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #58265058

Tender For Special Repair To Replacement Of 2X1.6 Mva 33/11 Kv Transformer And Connected Work Under Cwe Jabalpur

Issued by Statutory Bodies & Commissions/Committees · Jabalpur, Madhya Pradesh
Tender Value
1.41 Crore
Estimated cost
Bid Submission
21 Nov 2026
21 days left
EMD
2.17 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jabalpur → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Replacement Of 2X1.6 Mva 33/11 Kv Transformer And Connected Work Under Cwe Jabalpur

BOQ

Name of Work:- SPECIAL REPAIR TO REPLACEMENT OF 2X1.6 MVA 33/11 KV TRANSFORMER AND CONNECTED WORK UNDER CWE JABALPUR
Sl. No. Item Description
1Supply and fixing of new Air break gang operated switch, triple pole, mechanically operated out door with all fitting/ accessories mounted on and including 9 Nos. 33 KV porcelain insulator and steel channel frame Gi operating rod 25 mm dia of suitable length with operating mechanism worked from ground level horizontally operated rotating type with copper isolator as per site requirement including locking arrangement for operating handle complete suitable for current rating upto 400 Amps 33 KV complete all as specified and directed by Engr in charge.
2M&L for new lightning arrestor expulsion type complete with all fittings, transmision/ distribution class 65 KA, conforming to IS-3070 (Part-II) 1993 suitable for 33 KV system and mounting on poles including all necessary bolts, nuts and washers and making electric connection and testing on completion complete all as specified and directed.
3Taking down old unsv insulator any type any size
4M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore Gl pipe light grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore Gl medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge 8 mesh per linear including 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS TMT bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-1 (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same Gl earth strip alongwith protection pipe and testing on completion complete all as specified and directed.Note: GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by contractor
5M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised wire 4mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore Gl pipe light grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore Gl medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge 8 mesh per linear including 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS TMT bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-1 (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same Gl earth strip alongwith protection pipe and testing on completion complete all as specified and directed.Note: GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by contractor
6Taking down old unsv earthing any type complete all as specified and directed.
7Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables earthed (heavy duty) with stranded aluminium conductor, 11000 volts grade of size 3 core 120 sq mm. complete all as specified and directed.
8Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables earthed (heavy duty)with stranded aluminium conductor, 33000 volts grade of size 3 core 120 sq mm complete all as specified and directed.
9Taking down old unsv HT/LT cable any type any size complete all as specified and directed.
10Cross arm bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finished coat of paint complete all as specified and directed.
11Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc (Fe-290 (Gde E-165)) for 33 KV gantries yard complete all as specified and directed.
12Supply and fixing of new pin type polymer insulator vitreous white/brown/ green 150 mm high and 150 mm dia incl one galvanised mild steel spindle, two galvanised iron washers & one galvanised iron nut suitable for HT 33000 volts complete all as specified and directed.
13Supply and fixing of new disc type insulator, polymer, vitreous white/brown/green 145mm high and 225mm dia ball & socket type single disc assembly for tension with Gl tension clamps for conductors for working pressure of 33000 volts complete all as specified and directed.
14Supply & Fixing post type polymer insulator suitable for 33 KV complete all as specified and directed.
15Supply and fixing of new pin type porcelain, vitreous, white/ brown/ green insulator 150mm high and 150mm dia including one galvanised mils steel spindle, two galvanised iron washers and one galvanised iron nut, suitable for HT 11000 volts complete all as specified and directed.
16Supply & Fixing post insulator for Air Break switch with metal part suitable for HT 11KV conforming to IS 5572-1972 complete all as specified and as directed.
17Supply and fix cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 sqmm complete all as specified and directed.
18Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 sqmm complete all as specified and directed.
19M&L for cable jointing kit for 33 KV (Earthed) grade cable for outdoor cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm and testing on completion complete all as directed.
20Taking down old unsv jointing kit any type any size
21Supply & fix copper strip 32mm x 6 mm or hollow copper conductor of dia 25mm & 3mm thickness for connection of 33 KV supply network and 33/11 KV supply network including connector, clamp, Tee joints, straight joints etc
22Supply and fix Gl strip 32mm x 6mm buried in ground
23M&L for broken stone aggregate for loose filling under 11 KV four pole and arround the transformer, of gauge 40 mm graded in and including for stacking materials in regular heaps/stacks for measurement.
24Taking down old U/S CT any type and size.
25Taking down old U/S PT any type and size
26Taking down old unserviceable 33 KV out door type gang operated air-break switch
27Taking down old US lighting arrestor any type
28Dismantling cross-arms of M.S. channel or angle sections, rail/channels, purlins etc. complete and setting aside for re-use with in 50m
29M&L for shifting of transformers after disconnecting all connections and shifting to locations within 5 KM all as per required and directed by Engr in Charge.
30Taking down existing worn out/old/broken ACSR conductors of any size and length at any position from HT poles and supply, fixing and stretching new ACSR conductors of any size and type for over head HT poles including binding at site to insulator with suitable size of binding wire etc complete all as specified and directed by Engr in charge.
31Supply, Installation, testing and commisioning of Power Transformer step down, out door type SACADA compatible of capacity 1600 KVA, HT 33 KV/11 KV, 3 phase cycles AC with Off Load Tap Changing arrangements with remote control panel operation on 33 KV sides to vary secondary voltage from 5 position off , circle tap changer tapping range (+) 5% to (-) 5% in steps of 2.5%, % impedance should not be less than 6.50% at normal/common tap No. 7 including suitablemarshalling box and HV terminals 3 Nos outdoor bare bushings with socket and LV terminal connectors of copper to connect the transformer with HT XLPE Power cable of size 95 sqmm x 3 core with aluminum conductor and LV side additional Neutral with one No. solid porcelain type out door bushings with sockets on the transformer lid for earthing purpose complete in all respects with standard accessories and fittings conforming to IS-2026. HV(Primary) side delta and LV (secondary) side star connected including control pannel of transformer. The silent features of the transformer shall be as under:-
32(a) (i) Transformer shall be Dyn11 vector group oil immersed naturally cooled, double wound copper winding core type, Radiator cooled MS tank complete with first fill of transformer oil as per IS-335 with ONAN cooling system. The temperature of oil shall not rise 45°c to ambient 55°c of winding. Transformer shall be painted with two coats of synthetic enamel paint with two coats of expoxy paint as per IS-632.
33Standard Fittings:-(i) Rating and diagram plate alongwith levels where ever necessary.(ii) Earthing terminals - 2 Nos.(iii) Lifting lugs.(iv) Thermometer pocket with thermometer.(v) Air release hole with plug.(vi) Oil filling hole with plug on & incl. Conservator tank with drain valve and plug.(vii) Prismatic type oil indicator on one side of conservator tank with minimum and maximum oil level marking.(viii) Dehydrating breather-01 No(ix) Oil conservator with drain valve and plug.(x) Sampling valves, top and bottom.(xi) Under base with flat treaded bi-directional rollers.(xii) Drain cum bottom filter valve with plug(xiii) Top filter valve with plug.(xiv) Explosion vent with diaphragm and equalizer pipe (pressure release valve).(xv) Jacking lugs and hauling holes.(xvi) Inspection cover.(xvii) Detachable radiators with shut off valves between radiators and tank.(xviii) Radiator with air release hole and plug. Oil drain hole with plug and lifting eye all as per manufacturer's standards.
34(xix) 150mm dia oil temperature indicator stems type.(xxx) Double float Bucholtz relay with two sets of contacts' and isolating valves.(xxi) 150mm dia winding temperature indicator with maximum indicating pointer and resetting device.(xxii) 100mm dia magnetic oil level gauge with low level alarm.(xxiii) Terminal arrangements(xxiv) Suitable wheels (width/distance should be as per Broad Gauge rails).(xxv) Marshalling box Please Enable Macros to View BoQ information
35(xix) 150mm dia oil temperature indicator stems type.(xxx) Double float Bucholtz relay with two sets of contacts' and isolating valves.(xxi) 150mm dia winding temperature indicator with maximum indicating pointer and resetting device.(xxii) 100mm dia magnetic oil level gauge with low level alarm.(xxiii) Terminal arrangements(xxiv) Suitable wheels (width/distance should be as per Broad Gauge rails).(xxv) Marshalling box Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58265058
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.41 Crore
LAST DATE 21-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Replacement Of 2X1.6 Mva 33/11 Kv Transformer And Connected Work Under Cwe Jabalpur
Basic Detail
Tender No 81172/E8
Bidding Type Tender
Location
City Jabalpur
State Madhya Pradesh
Key Dates
Publish Date 29 Oct 2026
Submission Date 21 Nov 2026
Open Date 28 Nov 2026
Finance
Tender Value 1.41 Crore
Tender Fee 1000
EMD 2.17 Lakhs
Exemption Available
Document List
a1fbecd5-49c5-49db-884d-cd26e30b9e82.html
BOQ_893187.xls
Tendernotice_1.pdf
TENDER_81172.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Nov 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 28 days

Tender Documents

Download All (ZIP) ↓
html

a1fbecd5-49c5-49db-884d-cd26e30b9e82.html

xls

BOQ_893187.xls

pdf

Tendernotice_1.pdf

pdf

TENDER_81172.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender