Drinking Water Supply and Sanitation Government Departments Closing in 10 days TDR #58264938

Tender For Augmentation And Upgradation Of Raw Water Delivery, Effluent Treatment Management And Supply Infrastructure Including 600Mm Rwm Connection To 2.2Mgd Rsfp, Dual Sump Lift At Zero Effluent System, 4.3 Mg special repair Supply Network With In

Issued by Government Departments · Srinagar, Jammu and Kashmir
Tender Value
60 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
10 days left
EMD
1.20 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Augmentation And Upgradation Of Raw Water Delivery, Effluent Treatment Management And Supply Infrastructure Including 600Mm Rwm Connection To 2.2Mgd Rsfp, Dual Sump Lift At Zero Effluent System, 4.3 Mg special repair Supply Network With Interconnecting Trunk Mains, Security And Surveillance Systems And Allied Works At Water Treatment Plant Nishat Under Smc Capex (City Sustainable Infrastructure Fund) (Advt. Construction 60.00 Lacs)

BOQ

Name of Work:- Augmentation and upgradation of raw water delivery, effluent treatment management and supply infrastructure including 600mm RWM connection to 2.2MGD RSFP, Dual sump lift at zero effluent system, 4.3 MG SR supply network with interconnecting trunk mains, security and surveillance systems and allied works at Water Treatment Plant Nishat under SMC Capex (City Sustainable Infrastructure Fund) (Advt. Cost. 60.00 Lacs)
Sl. No. Item Description
1Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.In All kinds of Soils
2Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 min width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: In All kinds of Soils
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
4Demolishing cement concrete/ R.C.C manually/by mechanical means including disposal of material within 50meters lead as per direction of Eng.- in charge:1:3:6 or richer mix (i/c equivalent design mix)
5Desilting of zero effluent Pre Settling chamber Clarifloculator by manual means including use of tools etc as required .complete job .
6Supply and packing of boulder - filling hand packed and Graded to minimize void space including second class sand as filler- all complete.(Incl. carriage), actual qty as per execution and subsequent measurement.
7Providing/ laying of stone soling hand packed in trenches incld carriage
8Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
9Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
10Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
11Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade. Fe-500Dormore.
12Centering & shuttering including strutting, propping etc & Removal of form for
13Foundations, footing, bases of columns etc. for mass concrete.
14Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms.
15Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers.
16Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 (1 cement : 6 coarse sand) in superstructure above plinth level upto floor five level.
17Extra for brick work with common burnt clay bricks / cement concrete bricks in superstructure above plinth level upto floor five level.
18CEMENT PLASTER (IN FINE SAND) 15mm Cement plaster of mix:1:6 (1 cement : 6 fine sand) – Internal walls and external faces (Rates for external plaster are for height upto 10m from ground level unless otherwise stated)
19Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete
20Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer's specifications. non aesthetic surfaces without smooth finish or paint
21Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
22Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers' specifications: Two or more coats applied @ 1.25 litre/10sqm over and including one coat of special primer applied @ 0.75 litre/10sqm
23Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven storey height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffoldings for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations withessential safety features for the workmen etc complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding and only for portions out of reach without scaffolding and not the entire structure.
24Painting on GS sheet with synthetic enamel paint of approved brand & manufacture of required colour to give an even shade on old work (one or more coats).
25Painting with synthetic enamel paint of approved quality, brand and shade over and including one coat of red oxide zinc chrome priming paint on metal surfaces complete as per specification: M.S. Pipes, Covers and Lids etc. ( to be paid as per painted surface area measurment)
26Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : of area of 3 sqm. and below
27Of area beyond 3 sqm
28Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Kiln seasoned & chemically treated hollock wood.
29Providing & fixing panelled or panelled & glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Eng. incharge. (Note: -Butt hinges & necessary screws shall be paid separately).(Second class kail wood). 35mm thick Shutter.
30Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
31Providing & fixing ISI marked Oxidized M.S sliding door bolts with nuts and screw etc. complete. 250 X 16mm
32Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete. 250x10mm.
33Providing and fixing of ISI marked oxidized M.S. door latches confirming to IS: 5930 with screws etc. (300x20x6mm)
34Providing and fixing ISI marked oxidized M.S. handles conforming to IS: 4992 with necessary screws etc. complete : 125mm.
35Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
36Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture.
37Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work.
38Dismantling C.I. pipes manually/ by mechanical means breaking lead caulked joints, melting of lead & making into blocks including stacking of pipes & lead at site within 50 mtr lead as per direction of Eng. incharge.Including excavation & refilling trenches after taking out the pipes. Above 300mm diameter.
39Labour for cutting C.I. pipes by manually /mechanical means with including all sort of hire charges. 80 mm diameter C.I. pipe. 600 mm diameter C.I. pipe
40Providing lead caulked joints to spun iron or C.I. pipes and specials including testing of joints but excluding the cost of pig lead. 600mm dia pipe.
41Supply of pig lead to site including all carriages upto the site of work complete.
42Supply of spun yarn to site including all carriages upto the site of work complete.
43Providing and fixing including testing, commissioning & fabricating at site M.S pipe lengths of dimensions required and directed by engineer in charge (for straight lengths of more than 0.9 metre incld. all sorts of carriages upto site of work, as per requirement at site complete job. This job includes cutting, welding, making connection of these fresh lengths with existing pipe junctions or collars etc & making functional the same.
44Providing and fixing including Fabrication, testing, commissioning at site M.S pipe Specials - M.S tees , bends, collars flanges including cost Nuts, Bolts, washers etc & all sorts of carriages upto site of work, as per requirement at site complete job. This job also includes preparation of site spot by way of clearance of dismantled material, placing of tripod or other tools or tackles required for execution.
45Provisional quantity for providing and fixing of MS flanges at connectors , junctions etc of dia , thickness and pitch as directed by engineer in charge based on site conditions
46Dismantling of existing system including removal of suction/guide pipes, 125mm dia NRVs, sluice valves & defunct submersible pumping units currently installed in the pre-settling chamber, including disconnection of all electrical & mechanical connections, careful extraction of all components using proper tools & tackles. All dismantled/ salvaged material to be duly stacked, accounted for and handed over to the Plant In-charge complete. The job includes all labour, tools, tackles & carriage involved.
47Providing, supplying & fitting of 150mm dia FOOT Valves (NRV) of IS 4038 rating, Kirloskar,VAG , TALIS make or equivalent, including all flanges, nut bolts, gaskets & accessories complete as per site requirement.
48Providing, supplying & fitting of 200mm dia Non Return Valves (NRV) of PN 1.6 rating, Kirloskar, VAG, TALIS make or equivalent, including all flanges, nut bolts, gaskets & accessories complete as per site requirement.
49Repairs/restoration to the damaged 3Phase of various capacities of submersible pumping units of all kinds by way of disconnecting the power supply connections of Motor then dismantling of Motor from the base frame. The job includes dismantling of Motor assembly and then extracting the damaged/ burnt stator coils from the stator coils from the stator slots using proper tools & takles avoiding damage to the shtator core. The job includes inserting proper insulation in all slots and then complete rewinding of 3-Phase Motors in copper wire insulated having specific size and guage of superior quality & same within the existing power meters. The job shall further include registration of Motors on the frame and then recoupling of pump Motor and then completing the electric connections. The job includes cost on account of skilled man power, involved, tools, tackles besides all sorts of carriage involved complete. The rate includes rebate on old scrape to be retained by the contract agency. The job further includes complete overhauling and repair of the pump assembly of the submersible unit, comprising: dismantling of the pump bowl assembly; inspection and replacement/repair of impeller(s), wear rings, check nut & shaft sleeves as required; replacement of radial and thrust bearings; replacement of oil seals and mechanical seals; replacement of O-rings & all rubber/elastomeric components; thorough cleaning & inspection of the diffuser and bowl assembly; reassembly of the pump unit to OEM specifications; and re-coupling with the repaired motor. The complete unit shall be tested for satisfactory performance, leak-free operation and correct direction of rotation before handing over. All replacement spares shall be of standard/equivalent make & specification as approved by the Eng. incharge. Rate is inclusive of all spares, materials, skilled manpower, tools, tackles & carriage, complete. 75 HP Submersible.
50Overhauling, repair & complete reconditioning of existing fully automatic Star-Delta (FASD) Motor Starters (L&T MUG type or equivalent reputed make), on a complete job basis. The scope of work includes safely dismantling the non-functional starter from the panel, safe transportation/cartage from the site to the workshop & back, thorough servicing, and replacement of any or all faulty components as per site requirements to restore original OEM functionality. This includes the supply & installation of new contactor sets (fixed & moving contacts), thermal overload relays, integrated electronic star-delta timers & single phase preventers (SDz5 or equivalent) ,auxiliary/logic glass relays,start/off push buttons, heavyduty copper lugs/thimbles, internal control wiring, & insulation sleeves. The job also encompasses reinstallation into the panel, circuit integration,testing,commissioning, & handing over the system in perfect running condition.(Rate shall be inclusive of all materials, labor,machinery, tools & double-way transportation).The job includes proper test run & commisioning of the setup and shall only be paid as a wholly singular finished job. Upto 75 HP.
51Providing & fitting testing & commissioning of 10 HP MUG- starters.The job includes providing laying & fixing of connector cable from starter to the pump assembly incl. all fixtures, thimbles etc. whatever requirement for commissioning.
52Providing & fitting of various copper lugs/Thimbles (Dowells/Action/or any other reputed make) by using crimping tool as under: 6-10sqmm.
53Providing & fitting of various aluminium lugs/Thimbles (Dowells/Action/or any other reputed make) by using crimping tool as under: 25-50sqmm
54Providing and fitting of L.T, 3 core, capable to work up to 1.1 KV, XLPE insulated, galvanized steel strip armored Copper cable submersible conforming to IS: 7098 (part -1) 1988 With latest amendments to be utilized for interconnection of various electrical gadgets. The job includes providing & fitting of suitable rating copper thimbles duly crimped and taped at conductor ends by hydraulic crimping tool. The job includes laying of cable in cable tray. The Test Certificate of Cables duly stamped by manufacturer shall be provided at the time of supply of material 3 C x 16 sqmm 1.1kV grade (CU)
55Providing & fitting of XLPE insulated PVC sheathed power cable – solid aluminium conductor – Armoured 120 sq.mm 3.5 core cable along with thimbling as per requirments and reputed brand (Havells/Polycab) from stablizer to pumping setup/ starter.
56Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
57Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.- Rate for fabrication and fixing of control gates including winch control mechanism involving 50mm dia S.S threaded rod. handle and ball bearing (ring type) to allow for movement of rod/gate along the vertical plane. Actual specifications and dimensions for execution will be decided by engineer at site as per requirement.
58Providing and fixing G.I chain link fabric fencing of required width in mesh size 50x50mm including strengthening with 2mm dia wire or nuts bolts and washers as required complete as per the direction of engineer incharge. made of 4mm dia wire.
59Finishing with Deluxe multi surface paint system for exteriors using primer as per manufacturers’ specifications Painting steel work with deluxe multi surface paint of required shade to give an even shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.80litre/10sqm of approved brand and manufacture (if applied on surfaces such as chain link fencing appropriate gap percentage shall be deducted )
60Applying priming coat With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works (if applied on surfaces such as chain link fencing appropriate gap percentage shall be deducted )
61Installation of Hiknet/Hikvision camera door phone for single door entry near main gate including all fixing charges and connecting cables through requisite plastic tubes and fixtures required for control panel/screen installation at control room . Device specification and connectivity features to be strictly as per engineer in charge and shall only be paid as a Complete job and not a supply item.
62Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete.
63Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded.
64Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.50 mm thick with zinc coating not less than 275 gram/m2.
65Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.50 mm thick with zinc coating not less than 275 gram/m2.
66Providing and fixing 20 gauge (0.9mm) plain galvanised iron sheet as eave chajja / canopy projecting 375mm from face of parapet all round, fixed over MS angle iron 50x50x6mm supporting framework welded to bottom chord / end rafter of steel truss at 1200mm c/c, including cutting, bending, lapping, fixing with selfdrilling screws, sealing at wall junction. complete.
67Providing and fixing 24 gauge (0.63mm) pre-painted colour-coated GI sheet as soffit lining to underside of eave overhang, fixed to MS angle cleats with self-drilling screws at 250mm c/c, including all cutting, notching, lapping and finishing at edges with PVC trim complete.
68Providing and fixing 20 gauge (0.9mm) plain galvanised iron sheet as fascia board 200mm deep at outer eave edge all round, fixed to MS flat bar stiffener welded to end of rafter, including bending at bottom to form drip edge, lapping with roofing sheet at top, fixing with self-drilling screws, all complete.
69Carriage of materials from different sources up to the actual site of work including loading, unloading & stacking complete.
70Bricks for an Avg. lead of 25 Km
71Sand for an Avg. lead of 20 Km
72Aggregate for an Avg. lead of 25 Km
73Supply, carriage and assembly with functional test and commisioning of Exide Hybrid inverter 1125 v.a with exide solar tabular battery(2no.) 150 AH/160 watt and solar panels (no. depending on total power %age supplied by panels) complete with requisite fitting/ modifications in exisitng electrical settings (or any reputed brand approved by the engineer) .
74Making of 100mm & 80mm connection on 500mm MS clear water pipeline incl. fixing of all specials required like 100mm union,100mm nipple, 100mm tee & 80mm nipple, tee etc complete job (Sluice valves shall be paid separately)
75Providing and fixing D.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions
7680mm dia
77100mm dia
78150mm dia
79200mm dia
80300mm dia
81Supply, installation & fixing of reflective aluminium staff gauge scales (SRS) for water level measurement at reservoir/sump, complete with fixing bolts, nuts and sealant as per direction of Eng. incharge. (PVDF coated aluminium, reflective radium markings, 1m sections, accuracy ±2mm, confirming to CWC/IMD standards)
82Supply of self-amalgamating EPR (Ethylene Propylene Rubber) cable insulation repair tape of approved brand (3M Scotch-23 or equivalent) for repair/insulation of cable joints and terminations. Tape size: 19mm wide × 10m roll, rated up to 69 kV, as per direction of Engineer-in-charge.
83Wiring and switch/socket installation for Light point/Exhaust Fan/ Wall Fan/Ceiling fan Point with 1.5 sq.mm FR ( Havells/Finolex /Polycab/ KEI make ) PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm (excluding the cost of earth wire). FR PVC insulated multistrand copper conductor single core cable etc as required including the cost of PVC Conduits complete job.
84Wiring and 6/16 amp switch socket outlet for power point with 3x 4mm sq (P+N+E) FR PVC insulated 1100 volt grade multistrand copper conductor wire (Finolex/ Polycab/ Havells/KEI make) concealed/recessed manner through fresh 25mm dia PVC conduit (Polycab /Ravindra/Finolex make) including cost of cutting/ making good chases in brick work rough plastering & including the cost of supplying & fixing mounted 4no. 16amp modular 5/6 pin combined socket outlet along with 16 amp modular control switch both mounted on GI box etc in each switch box & to be completed as per specification & as required including bend,socket etc.
85Providing, fixing, testing and commissioning of Ceiling Fan, 1200mm (48\\") sweep, 75W, 3-blade, conforming to IS 374, with 300mm G.I./S.S. down rod, canopy set and C.I. hook box (internal dia 140mm as per IS), including 5-step electronic regulator conforming to IS 2121, make approved (Usha / Orient / Havells / Crompton or equivalent), all complete as per direction of Engineer-in-Charge. (Wiring point and switch to be paid for separately under Item for fan point.)
86Circuit wire to be laid through in Fresh PVC conduit for sub mains using following sizes of multistrand PVC insulated copper wire (Havells /Finolex/Polycab/KEI make FR) including the cost of PVC conduits complete job.
872 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
882 X 6 sq. mm + 1 X 6 sq. mm earth wire
895/6 amps socket Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58264938
AUTHORITY Government Departments
TENDER VALUE 60 Lakhs
LAST DATE 09-11-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Augmentation And Upgradation Of Raw Water Delivery, Effluent Treatment Management And Supply Infrastructure Including 600Mm Rwm Connection To 2.2Mgd Rsfp, Dual Sump Lift At Zero Effluent System, 4.3 Mg special repair Supply Network With Interconnecting Trunk Mains, Security And Surveillance Systems And Allied Works At Water Treatment Plant Nishat Under Smc Capex (City Sustainable Infrastructure Fund) (Advt. Construction 60.00 Lacs)
Basic Detail
Tender No 44/WWD/Sgr/Civil of 2026-27
Bidding Type Tender
Location
City Srinagar
State Jammu and Kashmir
Key Dates
Publish Date 29 Oct 2026
Submission Date 09 Nov 2026
Open Date 10 Nov 2026
Finance
Tender Value 60 Lakhs
Tender Fee 2000
EMD 1.20 Lakhs
Exemption Not Available
Document List
a0b2d021-be2d-4345-8e92-45b35bae3e08.html
BOQ_1117224.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Nov 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

a0b2d021-be2d-4345-8e92-45b35bae3e08.html

xls

BOQ_1117224.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender