Bids Are invited for Excavation Soft And Loose Soil Not Exceeding 1 Point 5 Metre Deep And Wide - Excavation In Trenches In Soft & Loose Soil Not Exceeding 1 Point 5 Metre Deep And Not Exceeding 1 Point 5 Mtr Wide All As Per Socpe Of Work , Returning
Tender Overview
Project Description
Bids Are invited for Excavation Soft And Loose Soil Not Exceeding 1 Point 5 Metre Deep And Wide - Excavation In Trenches In Soft & Loose Soil Not Exceeding 1 Point 5 Metre Deep And Not Exceeding 1 Point 5 Mtr Wide All As Per Socpe Of Work , Returning Filling In Soilsspreading Leveling Watering And Well Ramming - Returning, Filling In Soils Including Spreading Leveling Watering And Well Ramming All As Per Socpe Of Work , Removal Of Surplus Soils Not Exceeding 50 Mtr Distance - Removal Of Surplus Excavated Soils Not Exceeding 50 Mtr Distance And Depositing All As Per Socpe Of Work , M And L For Sand Filling With Clean Dry Find Sand Unwashed - Material & Labour For Sand Filling With Clean Dry Find Sand Unwashed All As Per Socpe Of Work , S And L Un Reinforced Pre Cast Flat Concrete Cable Protection Cover - Supplying And Laying Un Reinforced Pre Cast Flat Concrete Cable Protection Cover Of Class Hv Type I Size 300Mm X 180Mm X 40Mm All As Per Socpe Of Work , S And Fixing On Ht Pole Danger Notice Plate For Ht 11Kv - Supply And Fixing On Ht Pole Danger Notice Plate For Ht 11Kv Of Size 25 Cm X 20 Cm All As Per Socpe Of Work , Tubes Light Grade Galvanised Of Size 80 Mm - Tubes Light Grade Galvanised With All Fitting And Fixed Complete To Walls And Ceilings Or Laid In Floors Of Size 80 Mm All As Per Socpe Of Work , M And L For Earthing Complete With Gi Steel Earth Plate 600Mm X 600Mm X 6Mm - M And L For Earthing Complete With Galvanized Steel Earth Plate Electrode 600Mm X 600Mm X 6Mm Buried Directly In Ground Vertically To A Depth All As Per Socpe Of Work , M And L Earthing Complete With Copper Earth Plate Of Size 600X600x3point 5 Mm - All As Per Item Ser No 13 Here-In-Before But Copper Earth Plate Of Size 600Mmx600mmx 3 Point 5 Mm And Connected With Copper Strip Of Size 20 X 3 Mm Complete All As Per Socpe Of Work , M And L For Ht Heat Shrinkable Straight Through Jointing Kit Size 95 Sqmm - M And L For Ht Heat Shrinkable Type Straight Through Cable Jointing Kit Size 95 Sqmm 3 Core Complete All As Per Socpe Of Work , Supply And Fixing In Repair Lightning Arrester Single Pole 11 Kv 65 Kilo - Supply And Fixing In Repair Lightning Arrester Single Pole 11 Kv 65 Kilo All As Per Socpe Of Work , Sitc Of 11Kv Sf6 Gas 4Way Rmu 630 Amps - Sitc Of 11Kv Extensible Outdoor Duty Ip 55 Enclosure Sf6 Gas Insulated 4Way Motor Operated Rmu Of 01 Nos 630 Amps Load Break Switch As Incomer And 03 Nos 630 Ampsvacuum Circuit Breaker As Outgoing All As Per Socpe Of Work , Sitc Of 11Kv 630A Switch Sf6 Disconnector Outdoor Panel - Sitc Of 11Kv 630A Switch Sf6 Disconnector Outdoor Panel For Protection Of Various Transformers All As Per Socpe Of Work , Supply Erecting And Fixing Steel Tubular Swaged Pole 410 Sp55 11 Mtr Long - Supply Erecting And Fixing In Vertical Position Steel Tubular Swaged Pole 410 Sp55 11 Mtr Long Complete With Base Plate All As Per Socpe Of Work , Supply And Installation And Testing 11 Kv Outdoor Type God - Supply And Installation And Testing 11 Kv Outdoor Type , Gang Operated Air Break Switch Triple Pole Mechanically Operated All As Per Socpe Of Work , Sitc Of 100 Kva Level 03 Transformer 11Kv On Ht And 433 Volts On Lt Side - Sitc Of Capacity 100 Kva, Level 03 Outdoor Transformer Floor Mounted 11Kv On Ht Side And 433 Volts On Lt Side All As Per Socpe Of Work All As Per Socpe Of Work , Sitc Of 125 Kva Level 03 Transformer 11Kv On Ht And 433 Volts On Lt Side - Sitc Of Capacity 125 Kva, Level 03 Outdoor Transformer Floor Mounted 11Kv On Ht Side And 433 Volts On Lt Side All As Per Socpe Of Work All As Per Socpe Of Work , Sitc Of 160 Kva Level 03 Transformer 11Kv On Ht And 433 Volts On Lt Side - Sitc Of Capacity 160 Kva, Level 03 Outdoor Transformer Floor Mounted 11Kv On Ht Side And 433 Volts On Lt Side All As Per Socpe Of Work , Sitc Of 250 Kva Level 03 Transformer 11Kv On Ht And 433 Volts On Lt Side - Sitc Of Capacity 250 Kva, Level 03 Outdoor Transformer Floor Mounted 11Kv On Ht Side And 433 Volts On Lt Side All As Per Socpe Of Work , Sitc Of 500 Kva Level 03 Transformer 11Kv On Ht And 433 Volts On Lt Side - Sitc Of Capacity 500 Kva, Level 03 Outdoor Transformer Floor Mounted 11Kv On Ht Side And 433 Volts On Lt Side All As Per Socpe Of Work , Taking Out Of Transformers 100 Kva To 500 Kva Depositin In Mes Yeard - Taking Out Of Transformers Of Capacity 100 Kva To 500 Kva Carefully From Two Pole Or Four Struction And Depositin In Mes Store Yeard All As Per Socpe Of Work , Taking Out Old Unsv Ht Ug Cable Of Any Size , Dismantling Air Break Gang Operated Switches - Dismantling Air Break Gang Operated Switches Vertical/Horizontal Mounted Including Insulators And Operating Mechanism All As Per Socpe Of Work , Sitc 11 Kv Cables Conforming To Is 7098 Part-Ii 95 Sqmm 3 Core - Sitc 11 Kv Earthed Aluminium Conductor Screened Xlpe Insulated Armoured Shielded And Pvc Sheathed Cables Conforming To Is 7098 Part-Ii 95 Sqmm 3 Core
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Excavation soft and loose soil not exceeding 1 point 5 metre deep and wide | Excavation in trenches in soft & loose soil not exceeding 1 point 5 metre deep and not exceeding 1 point 5 mtr wide All as per socpe of work |
| 2 | Returning filling in soilsspreading leveling watering and well ramming | Returning, filling in soils including spreading leveling watering and well ramming All as per socpe of work |
| 3 | Removal of surplus Soils not exceeding 50 Mtr distance | Removal of surplus excavated Soils not exceeding 50 Mtr distance and depositing All as per socpe of work |
| 4 | M and L for sand filling with clean dry find sand unwashed | Material & labour for sand filling with clean dry find sand unwashed All as per socpe of work |
| 5 | S and L un reinforced pre cast flat concrete cable protection cover | Supplying and Laying un reinforced pre cast flat concrete cable protection cover of class HV type I size 300mm x 180mm x 40mm All as per socpe of work |
| 6 | S and fixing on HT pole danger notice plate for HT 11KV | Supply and fixing on HT pole danger notice plate for HT 11KV of size 25 cm x 20 cm All as per socpe of work |
| 7 | Tubes light grade galvanised of size 80 mm | Tubes light grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors of size 80 mm All as per socpe of work |
| 8 | M and L for earthing complete with GI steel earth plate 600mm x 600mm x 6mm | M and L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth All as per socpe of work |
| 9 | M and L earthing complete with copper earth plate of size 600x600x3point 5 mm | All as per item ser No 13 here-in-before but copper earth plate of size 600mmx600mmx 3 point 5 mm and connected with copper strip of size 20 x 3 mm complete all as per socpe of work |
| 10 | M and L for HT heat shrinkable straight through jointing kit size 95 Sqmm | M and L for HT heat shrinkable type straight through cable jointing kit size 95 Sqmm 3 core complete All as per socpe of work |
| 11 | Supply and fixing in repair Lightning arrester single pole 11 KV 65 Kilo Amp | Supply and fixing in repair Lightning arrester single pole 11 KV 65 Kilo Amp All as per socpe of work |
| 12 | SITC of 11KV SF6 gas 4way RMU 630 Amps | SITC of 11KV Extensible Outdoor duty IP 55 enclosure SF6 gas insulated 4way motor operated RMU of 01 nos 630 Amps Load Break Switch as incomer and 03 nos 630 AmpsVacuum Circuit Breaker as outgoing All as per socpe of work |
| 13 | SITC of 11KV 630A switch SF6 disconnector outdoor panel | SITC of 11KV 630A switch SF6 disconnector outdoor panel for protection of various transformers All as per socpe of work |
| 14 | Supply erecting and fixing steel tubular swaged pole 410 SP55 11 mtr long | Supply erecting and fixing in vertical position steel tubular swaged pole 410 SP55 11 mtr long complete with base plate All as per socpe of work |
| 15 | Supply and installation and testing 11 KV outdoor type GOD | Supply and installation and testing 11 KV outdoor type , gang operated Air break switch triple pole mechanically operated All as per socpe of work |
| 16 | SITC of 100 KVA Level 03 transformer 11KV on HT and 433 volts on LT side | SITC of capacity 100 KVA, Level 03 outdoor transformer floor mounted 11KV on HT side and 433 volts on LT side All as per socpe of work All as per socpe of work |
| 17 | SITC of 125 KVA Level 03 transformer 11KV on HT and 433 volts on LT side | SITC of capacity 125 KVA, Level 03 outdoor transformer floor mounted 11KV on HT side and 433 volts on LT side All as per socpe of work All as per socpe of work |
| 18 | SITC of 160 KVA Level 03 transformer 11KV on HT and 433 volts on LT side | SITC of capacity 160 KVA, Level 03 outdoor transformer floor mounted 11KV on HT side and 433 volts on LT side All as per socpe of work |
| 19 | SITC of 250 KVA Level 03 transformer 11KV on HT and 433 volts on LT side | SITC of capacity 250 KVA, Level 03 outdoor transformer floor mounted 11KV on HT side and 433 volts on LT side All as per socpe of work |
| 20 | SITC of 500 KVA Level 03 transformer 11KV on HT and 433 volts on LT side | SITC of capacity 500 KVA, Level 03 outdoor transformer floor mounted 11KV on HT side and 433 volts on LT side All as per socpe of work |
| 21 | Taking out of transformers 100 KVA to 500 KVA depositin in MES yeard | Taking out of transformers of capacity 100 KVA to 500 KVA carefully from two pole or four struction and depositin in MES store yeard All as per socpe of work |
| 22 | Taking out old unsv HT UG cable of any size | Taking out old unsv HT UG cable of any size All as per socpe of work |
| 23 | Dismantling air break gang operated switches | Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism All as per socpe of work |
| 24 | SITC 11 KV cables conforming to IS 7098 Part-II 95 Sqmm 3 core | SITC 11 KV Earthed aluminium conductor screened XLPE insulated armoured shielded and PVC sheathed cables conforming to IS 7098 Part-II 95 Sqmm 3 core |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender