Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #58261958

Tender For Provn Of Micro Processor Based Lift At (P-19 New Bldg) Cmdc (Nc) Under Ge (Utilities) Udh Ur

Issued by Statutory Bodies & Commissions/Committees · Reasi, Jammu and Kashmir
Tender Value
90.42 Lakhs
Estimated cost
Bid Submission
01 Dec 2026
9 days left
EMD
1.60 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Reasi → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provn Of Micro Processor Based Lift At (P-19 New Bldg) Cmdc (Nc) Under Ge (Utilities) Udh Ur

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 18-Nov-2026 Corrigendum No.1 Date 01-Dec-2026

BOQ

Name of Work:- PROVN OF MICRO PROCESSOR BASED LIFT AT (P-19 NEW BLDG) CMDC (NC) UNDER GE (UTILITIES) UDH UR
Sl. No. Item Description
1BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER, UDHAMPUR Name of Work: PROVN OF MICRO PROCESSOR BASED LIFT AT (P-19 NEW BLDG) CMDC (NC) UNDER GE (UTILITIES) UDHAMPUR Contract No: CWE/U(U)- 77/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words
2Supply, install, testing & commissioning 13 Passengers Machine Room Less Lift suitable to serve G+2 floors with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories conforming to IS : 17900, simplex collective selective automatic & manual dual controlled operation with/without attendant, automatic centre opening doors with VVVF door drive (electric motor driven mechanism), sliding glass vandalproof doors and vandalproof textured cabin (opening size not less then 900 x 2100 mm), automatic rescue device (ARD) system with audio announcer equipped with 3 Way Intercom, complete all as specified and directed by Engr-in-charge NOTE- Contractor/OEM Rep requested to visit the site before quoting the ratesSpecification of lift-Elevator Type- Passenger elevatorLoad & Capacity- 884 kg or 13 personsSpeed -1 m/s single speed motorStops & Openings- 3 stops & 3 openings, Single entrance carTravel height- 8 mElevator Grouping- Simplex Full Collective ControlWell Dimension- 1900 mm width and 2600 mm depthHead Room height- 4200 mm Pit Height- 1600 mm Car dimensions-1350 mm wide x 1600 mm deep x 2300 mm highDoor dimensions- 900 mm wide x 2100 mm internal height
3Srl item No 1 Contd … Car Finishes:-Car design-SS silver brushedCar Panel Finish-SS Vandalproof TexturedCar Wall Material Thickness(mm) - As per Latest IS normsHandrail-Round Bend Handrail Silver brushed stainless steel (ST4) at Rear WallCeiling & Lighting-Integrated roof HS80 Stainless Steel Hue spot LED lightFlooring-20 mm Customer provide Granite StoneCar skirting material: Stainless steel Hairline AISI441Car Door Finish-SS Vandalproof Textured.Standard Features:-Correction drive to next levelEmergency Alarm @ Main FloorUnintended Car Movement Protection (UCMP)Overload protection function with L.W.D. (Load Weighing Device), constant indication/BuzzerBypass load FunctionAuto Cut off Fan and LightCentralized Hoisting for lesser vibration and smooth travelFireman's Emergency ServiceMicro movement Led Based ButtonsAscending Car Overspeed Protection(ACOP)Direction & Position Indicator In Car & LandingOverspeed Governor
4Srl item No 1 Contd … Advanced Car Position IndicationAutomatic Brake Test function every 11hoursPhase reversal functioningManual Rescue Operation+10% to –10% Voltage Fluctuation Withstanding CapacityDoor Open ButtonCar Emergency LightCurtain of light(IR Sensor) fix to sillAccurate Relevelling, Automatic, Closed DoorCar door interlockAdditional Features:-BMV M, Modulated line brakingYes Gong in CarEmergency Rescue Device with audio announcerE-link provision onlyThree way intercomNudging serviceParking Predefined floor - Doors closedHue spot LED lightCCTV provision KONE API service readyK1; IS17518 E120 for landing doorElec surge protection
5Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sq.mm. 3.5 core,complete all as specified and as directed.
6Supply and installation , testing and commissioning of diesel engine driven generating set of capacity 30 KVA output at NTP with AMF control panel, 415 Volts, 50 C/S AC, 3 phase 4 wire at power factor of 0.8 lagging all as per IS- 4272/2001, DG set mounted on common base plate and directly coupled through flexible coupling of diesel engine with cushy foot mountings (anti vibration) pad in and including acoustic insulated encloser/canopy with less 75 db noise level at 01 metre distance from DG set, complete with self starting system including accssories, equipment control panel ete complete as per manufacurers recommendations and to the satisfaction of Engr in charge.(a) Alternator (bush less) shall be design for an output of 30 KVA at full load for continuos rating at 0.80 PF AC 3 phase 4 wire 415 Volts 50 C/S with 1500 RPM speed, self excited self excited self regulated, screen protected, drip proof construction with insulation class 'H' with two end shield ball/roller bearing with damper winding in each pole faces as per IS-4722 or BS 2613-1970. The armature winding to be fixed on the stator and field winding on the rotor with complete AVR connections complete all as specified and directed.(b)Diesel Engine :- Diesel Engine air cooled of suitable BHP and electric start suitable to drive above alternator independently, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type as per BS-649 or IS-1601 with A1 electronic governor suitable to regulate speed of DG set from No load complete with fuel tank of capacity as per manufacturer recommendations, fuiel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standared accessories,
7Srl item No 3 Contd … sump pre pre heaters etc all as specified and direcetd. (c) Control Panel : - The standared AMF panel consisting of control cubical fabricated sheet steel construction indoor type suitable for mounting accessories, multifunctional digital meter suitable for measuring energy, power factor, frequency, voltage (0-500) volts and current, including CT's of suitable ratio with inbuilt selector switch, indicator lamps LED type hours meter/RPM indicator, lub oil pressure gauge, water temperature gauge, oil temp gauge & fuel level indicator safety control for engine shut off (trip with visual indication) for low lube oil pressure, safety control for engine shut off (trip with visual indication) for high wtare temperature, safety control (trip with visual indication) for low fuel level with protection of short circuit/over load and auto shut down.(d) Elctric starter equipment :- The equipment will comprise the followngs : (i) Maintenance free sealed lead acid battery 12 V & Battery lead of adequate size and capacity (ii) Starter Motor (iii) Starter gearing (iv) Start/Stop push button.(vi) Invertor cum battery charger 500 VA capacity suitable to work on 230 Volts 50 Hz AC supply system for charging of DG Set batteries externally when DG set is in off position (vi) Alternator/Dynamo of suitable capacity to charge the batteries while DG sets running complete with cut out all as per manufacturer recommendation os required at site or directed by Engr-in-Charge (vii)Cost of Foundation of DG Set to be included in quoted rate(viii)Diesel Engine should conform to latest CPCB norms
8Earthing complete with galvanised steel earth plate electrode 600mm×500mmx6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the piate not less than 1.5m below normal ground level) connected to and including galvanised strip 32x5mm by means of bolts, nuts, check nuts and washers of galvanised iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2.4 cover reinforced with 8mm dia TMT bars 150mm C/C both ways and 12 mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mesh and light grade Gi protection pipe 40mm bore upto 5m length for drawing in earth lead wire, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus soil to a distance not exc. 50m complete all as shown in electrical plate No 3 of MES schedule 2009 (Pt-1) and connected to main control board all as specified or indicated including testing on completion.
9Supply, installation, commisioning & testing of LT panel board outdoor type floor mounted/wall mounted as per site requirements having independent compartment for bus bar incoming feeder and each out going feeders, dust and vermin proof factory made, fabricted out of 3.15 mm thick CRCA sheet suitable for 3 Phase, 415 volts 50 Hz, AC supply, bus bar chamber with copper bus bar of 300 Amp rating for 3 Phase and 4 wire system duly insulated with heat shrinkable type sleeves as per colour codeComprising of following-(a) MCCB 4 Pole 100 Amps Ics =100%Icu, breaking capacity of 25 KA-01 No. (Incoming)(b) MCCB 4 Pole 63 Amps Ics =100%Icu, breaking capacity of 25 KA-03 No. (outgoing)(c) Digital Ammeter with CT ratio 200/5 Amps with selector switch-01 No.(d) Digital Voltmeter 0-500 V with selector switch-01 No(e) LED Indicator lamp with holder 3 Nos-01 Set.(f) Connector with suitable size bus barNote-:1) The pannel shall be front operatded with cable entry from the bottom with cable glands. The fault with standing Capacity shall be 50 KA & earth bus shall be part of the LT panel.(2) Fabrication of panel box to be done by CPRI approved manufacturer(3) Cost of earth work and construction of platform for panel, brick masonary in cement mortar 1:6 with foundation PCC 1:4:8 (type D-2) including plaster work, PCC coping 1:2.4 (20mm thick crushed stone aggregate), deemed to be included in this item rate.
10Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed.
11Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and as directed.
12Dismantling structural steel any description including door steel gates etc complete all as specified and directed.
13Dismantling boarding any discription fixing in any position with nails complete all as specified and as directed.
14Surface excavation not exc. 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified.
15Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, complete all as specified and as directed.
16Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (not exceeding 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m to 3.0m, complete all as specified and as directed.
17Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete, complete all as specified and as directed.
18RCC M-25, design mix, using 20mm graded crushed stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc., complete all as specified & directed.
19Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil,complete all as specified and as directed.
20Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed.
21Reinforced cement concrete M-25 design mix (using 20 mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts, complete all as specified and as directed.
22RCC M-25 (design mix), using 20 mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed.
23Reinforced cement concrete M-25 design mix, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed.
24RCC M-25 (design mix), using 20 mm graded crushed stone aggregate as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses, complete all as specified and as directed.
25RCC M-25 Design mix, using 20mm graded crushed stone aggregates as in fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like, complete all as specified and as directed.
26Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter including rough finished flat surfaces of concrete, complete all as specified and as directed.
27Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc, square, ractangular or polygonal, to obtain rough finished surface of flat concrete complete all as specified and as directed.
28Formwork for fair finished to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
29Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
30Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, complete all as specified and directed.
31Formwork to Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like, complete all as specified and as directed.
32TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and including binding with MS wire (annealed not less than 0.9mm dia), complete all as specified and as directed.
33TMT mild steel bars, 6mm to 8mm dia, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) complete all as specified and as directed.
34TMT mild steel bars, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and includingMS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed.
35Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4,complete all as specified and as directed.
3615mm thick rendering on other than fair faces of brick or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement, complete all as specified and as directed.
3720mm thick rendering on other than fair faces of brick or concrete surfaces in cement mortar 1:4 with WPC, finished even and fair, complete all as specified and as directed.
385mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed.
39Preparation new surfaces plastered or unplastered and applying three coats of white wash on wall, complete all as specified and as directed.
40Preparation new surfaces plastered or unplastered and applying three coats of white wash on ceiling, complete all as specified and as directed.
41Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance asper IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10sqm over a coat of wall care putty over new/old surfaces complete all as specified and as directed.
42Supply and fix powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates (minimum thickness of powder coating 50 micron) including joining cleat for fixing etc.complete all as specified and directed.
43Powder coated (not less than 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete, all as specified and directed.
4412 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with screws to timber frame work complete, all as specified and directed.
45Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
464mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in eachpane complete all as specified and directed.
47Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and or reveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 grade-E-165, complete all as specified.
48Supply and fixing Polythene film, 150 micro thick laid on bitumen primer, complete all as specified and as directed.
49Sand filling under floors or in foundations including watering and consolidation and complete all as specified and as directed.
50Hard core of gauge exc 63mm but not exc 100mm using broken stone or boulders, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified.
5175 mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base, complete all as specified and as directed.
5225 mm thick PCC 1:2:4 type B-0 (using 12.50 mm graded crushed stone aggregate) as in sub base for laying floor finishes complete all as specified and directed.
53Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match,over and including 20 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed.
54125 mm thick PCC M-15 nominal mix, complete all as specified and as directed.
5550 mm thick PCC type C-1 1:3:6 using 20mm graded crushed stone aggregate as in plinth protection laid in alternate pannels finished even and smooth without using extra cement complete all as specified and as directed.
56Glazed coloured ceramic jointfree/rectified tiles 450mm x 300mm x 7 to 8mm /600 mm x 300 mm x 7 to 8mm thick on vertical surfaces of walls as in dado/skirting etc., set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including 10 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engr-in-Charge.
5718 to 20 mm thick granite, single piece, (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and mirror finish polishing over and including 15 mm thick screed bedding/ backing layer in CM 1:6, complete all as specified and as directed.
58Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 5mm thick plastering in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately). Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric five layred APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.5 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm & including two coats of bituminous Aluminium paint, complete all as specified and as directed by Engr-in- Charge.
5925 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) as in floor and finished even and fair complete all as specified and directed.
60Supply only water proofing compound complete all as specified and as directed.
61Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc., complete all as specified.
62Plain cement concrete 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in coping, benching and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
63Providing outsourcing of Elevator attendant/ operator cum rescue (semi-skilled) for 13 passenger lifts. The lift attendant should be well trained to rescue the passenger in case the lift is stuck. The lift attendant/ operator (semi-skilled) deployed as per the following manner complete all as specified and as directed by Engr-in-Charge :- (a) CMDC (P-19 New Bldg) (Total lifts - 01 Nos lift) (Gound + Two i.e. total three landings) (i) Including Sunday & holiday.(ii) Ist shift - 0600 hrs to 1400 hrs - 01 Nos lift attendant/ operator cum rescue(iii) IInd Shift - 1400 hrs to 2200 hrs - 01 Nos lift attendant/ operator cum rescue Total = 02 operators, Total Shifts = 02Notes:-(i) Contractor shall monitor the duties of all lift attendant/ operator cum rescuer and specifically during change of shift and submit report to concerned JE E/M / Engr-in-Charge.(ii) Contractor will monitor the attendance of lift attendants/operator cum rescuer at a central location at each item of Sch 'A' or as decided by Engr-In-Charge.(iii) All lift attendants/ operator cum rescuer should be in possession of mobile for ease of communication.
64NOTES Contd … NOTES Contd … (iv) Contractor shall provide only trained lift attendant/ lift operator cum rescuer.(v) Duty roster will be submitted by the contractor before commencement of the month for obtaining the approval of JE and Engr-in-Charge.(vi) Each lift attendant/ operator shall be responsible for operating the lifts of detailed blocks/ buildings which are at nearest location or as directed by Engr-in-Charge.(vii) The lift attendant/operator cum rescuer should have the requisite qualification / experience as specified in the tender.(viii) Contractor should arrange proper uniform with name plate on shirt for the operators and its cost shall be deemed to be inclusive in the quoted rate.(ix) The operator shall also be responsible to inform any complaint of non functioning of lift to the Engr-In-Charge/JE E/M.(x) The contractor shall provide reliever of lift attendant/ lift operator as per labour rules & regulations, the rates for which are deemed to be inclusive in the quoted rate.
65Comprehensive maintenance of lift installed at CMDC (P-19 New Bldg) in reliable safe and efficient operating condition through MOU with OEM by regularly examining, lubricating and adjusting the equipments and carry out planned maintenance in systematic and controlled manner suitable for serving Ground + 2 floors (total three landings) 13 passengers with electric power operated doors, auto electric levelling device installed complete all type of mechanical and electrical items, governor sleeve, gears, gear shaft assembly, bearings, brake contact, brake shoe liner, brake magnets, governor jaws, sheave or main rope, trailing cable, speed governor rope, all type of electric motors, car & hall mechanical buttons, car, electric motor drive (electronic motor strater) & hall position indicators, car direction indicators and all other car and landing signal / fixtures, deflectors, car and counter weight guide rails and buffers, wire, lugs, nut, bolts, screws, hand rails, light luminaries, ventilating fan, hooter, lubricant, gear oil, aircord, rollers, landing wheel, aircord wheel, rubber bush, rail guide shoe, infra red door sensors, automatic door operating system, travelling cables, ARD, Batteries, car doors, landing gates, door sills, 3-Way intercom system, CVT, all types of control panel PCBs, transducers, transformers, rectifires, phase sequence corrector & single phase preventer, relays & cards etc and all machine works i.e. welding, cutting, drilling etc as and when required incl sunday and holidays, after completion of defect liability period, complete all as directed to entire satisfaction of GE.
66Srl item 61 Contd … Comprehensive, preventive, periodical maintenance after completion of defects liability period and attending day to day complaints for smooth functioning of lifts/elevators (01 Nos) installed at Blocks mentioned here in under:-(a) Provn of Micro processor based lift at (P-19 New Bldg) Under GE (Utilities) at Udhampur 13 passenger lift -(01 Nos Lifts).Note :- (i) Comprehensive maintenance will start only after completion of defect liability period, complete all as directed to entire satisfaction of GE.(ii) Any Maintenance/replacement of any items during defect liability period will be borne by the contractor.(i) The entire work relating to comprehensive, preventive and periodical maintenance of lifts/elvators (including supply of spares) as mentioned above, shall be got executed through the manufacturer from whom the new lifts/elevators are procured. (ii). The cost of all kind of replaced defective part(s) / spare(s) / control card(s) / oil / lubricants etc or any other component(s) / item(s) whether mentioned or not mentioned here-in-before, as and when required to make the lift/elevator fully functional, is deemed to be included in quoted rates and no extra cost shall be paid to the contractor on this account.(iii). The comprehensive / preventive / periodical maintenance includes monthly, inspection/testing as per service manual or as per IS standard. The inspection / test report will be submitted to GE. (iv) The contractor will have to submit MOU & aggreement in last month of defect liability period and at least 15 Days before commencement of comprehensive maintenance.
67NOTES Contd … (v) Contractor will conclude AMC for contract with OEM and copy of the agreement will be submitted to Engineer-in-Charge and GE before commencement of AMC. No payment will be made to contractor without submission of valid AMC agreement. (vi) The above maintenance include complete maintenance of newly installed lift by regularly and systematically examining adjusting fabricating as required for smooth and efficient functioning of the equipment/lift. (vii) The OEM will also detail one technical staff to inspect the lift every week. regarding its functioning operation or any other issue arising in the lift.Technician should always carry service tool along with himself during each weekly visit. (viii) Sufficient stores should be kept in stock with OEM to address the problem/complaints immediately. (ix) All existing earthing of the lifts shall be watering of all existing earthing of the lifts and cheacking for functional shall be done by the contractor to the entire satisfaction of the GE. Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58261958
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 90.42 Lakhs
LAST DATE 01-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Micro Processor Based Lift At (P-19 New Bldg) Cmdc (Nc) Under Ge (Utilities) Udh Ur
Basic Detail
Tender No CWE/U(U)-77/2026-27
Bidding Type Tender
Location
City Reasi
State Jammu and Kashmir
Key Dates
Publish Date 18 Nov 2026
Submission Date 01 Dec 2026
Open Date 03 Dec 2026
Finance
Tender Value 90.42 Lakhs
Tender Fee 1000
EMD 1.60 Lakhs
Exemption Not Available
Document List
9ab75419-ccf3-4513-a9f2-b6bd6d7768e1.html
BOQ_893145.xls
Tenderdocuments.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 01, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 9 days
Dec 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Dec 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

9ab75419-ccf3-4513-a9f2-b6bd6d7768e1.html

xls

BOQ_893145.xls

pdf

Tenderdocuments.pdf

pdf

Tendernotice_1.pdf

Disclaimer