Tender For special Repair Of Lt Panels And Replacement Of Low Tension Acsr To Underground Low Tension Cable At Lower Leimakhong Mil Stn Under Ge 869 Ews.
Tender Value
48.18 Lakhs
Estimated cost
Bid Submission
20 Nov 2026
18 days left
EMD
96360
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kangpokpi → Manipur
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair Of Lt Panels And Replacement Of Low Tension Acsr To Underground Low Tension Cable At Lower Leimakhong Mil Stn Under Ge 869 Ews.
BOQ
| Sl. No. | Item Description |
| 1 | Schedule 'A' |
| 2 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, poles struts, laying of cables/pipes, etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in Soft/loose soil complete all as specified and directed. |
| 3 | Taking up/down worn out/damaged/unserviceable PVC insulated underground cable armoured, heavy duty with aluminium conductors of any size, 1100V grade from trench/duct/pole/wall/pipes/rooftops etc. complete all as specified and directed. |
| 4 | Supply, laying, Jointing connecting in repair of LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 400 sqmm 3.5 core laid in trenches / on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed. |
| 5 | All as per serial item No. 03 above but for 240 Sqmm 3.5 Core. |
| 6 | All as per serial item No. 03 above but for 185 Sqmm 3.5 Core. |
| 7 | All as per serial item No. 03 above but for 120 Sqmm 3.5 Core. |
| 8 | All as per serial item No. 03 above but for 95 Sqmm 3.5 Core. |
| 9 | All as per serial item No. 03 above but for 70 Sqmm 3.5 Core. |
| 10 | All as per serial item No. 03 above but for 50 Sqmm 3.5 Core. |
| 11 | All as per serial item No. 03 above but for 35 Sqmm 3.5 Core |
| 12 | All as per serial item No. 03 above but for 25 Sqmm 4 Core. |
| 13 | All as per serial item No. 03 above but for 16 Sqmm 4 Core. |
| 14 | All as per serial item No. 03 above but for 16 Sqmm 2 Core. |
| 15 | All as per serial item No. 03 above but for 10 Sqmm 2 Core. |
| 16 | S&F of 1100 volts grade heavy duty cabled PVC insulated aluminium conductor served with inner sheating of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than one meter apart including 4 mm suspension wire one twin core cable 2 core flat of 10 sqmm size complete all as specified and directed. |
| 17 | Supply and spread sand in trenches as sand cushioning to underground cable for protection with dry fine river sand and provide required cover after punning down 18CM will be measured and paid complete all as specified and directed.(Note: Thickness of sand cushion after punning down will be measured and paid.) |
| 18 | Supply and laying well burnt sub class ‘B’ bricks ( designated 75) locally available best quality, laid dry in trenches for protection of underground cable all as specified and directed. |
| 19 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm as in soils complete all as specified and as directed. |
| 20 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point as in soils complete all as specified and as directed. |
| 21 | Material and labour for cutting of road/ hard standing n exc 20cm width and n exc 60cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 to match with existing surface complete all as specified and as directed. |
| 22 | Supply and laying in replacement of GI tubing 80 mm bore, medium grade as in cable protection pipe including all fittings complete all as specified and directed. |
| 23 | S&F Sheet metal enclousre Vertical DB (for DB's when MCCB/MCBs to be used) Triple pole and neutral double door, IP-54, 4way, 415 Volts with rated bus bar of size phase 200 Amps, 2xneutral bar 300 Amps and 2xEarth bar including MCCB 4pole, 415 Volts, fixed Type, 125 Amps with breaking capacity 16 KA complete all as specified and directed. |
| 24 | M&L in repair of earthing complete with galvanized steel plate electrode 600 X 600 X 6 mm thick buried directely in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI earth wire 4mm as earthing lead by means of galvanized steel bolts,nuts check nuts and washers and other end connected with to Poles, Pannel board etc as directed including funnel, 20 mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50 mm thick pre cast RCC 1:2:4 type B1 with 8mm dia cover slab set in CM (1:4) reinforcement with 8mm dia deformed bars @ 15 cm C/C and suitable handle of 10mm dia MS round bars, including earth work as required complete all as shown in electrical plate No. 5 of MES schedule Part I and testing complete all as specified and as directed. (Note: GI Earthing strip upto 7.5m in length is deemed to be included in the unit rate. The Strip required beyond 7.5m shall be measured and paid for separately) |
| 25 | Supply, installation , testing and commissioning outdoor cubical type CPRI approved LT Panel (Main LT Panel) weather proof panel board (protection class IP-54) powder coated outdoor type double door shutter, made out of CRCA 3.15 mm thick sheet for outer and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outoor, floor mounting type with closed bus bar , chamber and with copper bus bar with necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supply including provn of digital Am-meter 0-300A, digital Volt-meter 0-500 Volts, CT's of suitable ratio,indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc . The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron (Main Panel)Copper bus bar capacity 600 Amps for Phase-R-Y-B- & neutral MCCB FP 630 Amps 35 KA Adjustable type (Incommer) - 01 NosMCCB FP 400 Amps 16 KA- 01 Nos MCB TPN 40 to 100 Apms 10 Ka 'C' Curve - 03 Nos MCB SPN 40 to 63 Amps 10 Ka 'C' Curve - 04 NosMCB SPN 6-32A 10 KA - 05 NosDigital voltmeter, ammeter and indicator lamp of suitable capacity- 01 |
| 26 | Supply, installation , testing and commissioning outdoor cubical type CPRI approved LT Panel (LT Panel -1) weather proof panel board (protection class IP-54) powder coated outdoor type double door shutter, made out of CRCA 3.15 mm thick sheet for outer and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outoor, floor mounting type with closed bus bar , chamber and with copper bus bar with necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supply including provn of digital Am-meter 0-300A, digital Volt-meter 0-500 Volts, CT's of suitable ratio,indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc . The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron (Main Panel)Copper bus bar capacity 300 Amps for Phase-R-Y-B- & neutral MCCB FP 400 Amps 35 KA Adjustable type (Incommer) - 01 NosMCCB FP 125 Amps 16 KA- 02 Nos MCCB FP 63 Amps 16 KA- 02 Nos MCB TPN 40A 10 KA - 01 NosMCB SPN 40 to 63 Amps 10 Ka 'C' Curve - 05 NosOnload Changeover 315 Amps - 01 NosDigital voltmeter, ammeter and indicator lamp of suitable capacity- 01 |
| 27 | Supply, installation , testing and commissioning outdoor cubical type CPRI approved LT Panel (Sub LT Panel-1 & 2) weather proof panel board (protection class IP-54) powder coated outdoor type double door shutter, made out of CRCA 3.15 mm thick sheet for outer and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outoor, floor mounting type with closed bus bar , chamber and with copper bus bar with necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supply including provn of digital Am-meter 0-300A, digital Volt-meter 0-500 Volts, CT's of suitable ratio,indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc . The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron (Main Panel)Copper bus bar capacity 250 Amps for Phase-R-Y-B- & neutral MCCB FP 160 Amps 35 KA (Incommer) - 01 NosMCCB FP 63 Amps 16 KA- 01 NosMCB TPN 40A 10 KA - 02 Nos MCB SPN 6-32A 10 KA - 06 NosDigital voltmeter, ammeter and indicator lamp of suitable capacity- 01 |
| 28 | Supply, installation , testing and commissioning outdoor cubical type CPRI approved LT Panel Sub LT Panel-3) weather proof panel board (protection class IP-54) powder coated outdoor type double door shutter, made out of CRCA 3.15 mm thick sheet for outer and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outoor, floor mounting type with closed bus bar , chamber and with copper bus bar with necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supply including provn of digital Am-meter 0-300A, digital Volt-meter 0-500 Volts, CT's of suitable ratio,indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc . The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron (Main Panel)Copper bus bar capacity 150 Amps for Phase-R-Y-B- & neutral MCCB FP 100 Amps 16 KA (Incommer) - 01 Nos MCCB FP 63 Amps 16 KA- 02 Nos MCB TPN 40A 10 KA - 01 NosMCB SPN 6-32A 10 KA - 04 NosDigital voltmeter, ammeter and indicator lamp of suitable capacity- 01 |
| 29 | Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized iron 25 x 4 mm strip as earthing lead by means of galvanized steel bolts, nuts check nuts and washers and other end connected with to Transformer ,DG set,Panel Board etc as directed including funnel, 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1with 8mm dia cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work as required complete all as shown in electrical plate No 5 of MES Schedule Part I and testing complete all as specified and as directed. (Note: GI Earthing strip upto 7.5m in length is deemed to be included in the unit rate. The Strip required beyond 7.5m shall be measured and paid for separately) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysNov 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender