Tender For Overhead Ht Lt Line Shifting And Underground Work In Chambal Garden And Bheetariya Kund Under Municipal Corporation Kota
Tender Overview
Project Description
Tender for Overhead Ht Lt Line Shifting And Underground Work In Chambal Garden And Bheetariya Kund Under Municipal Corporation Kota
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-Nov-2026 | NNK/ELECTRIC/2026/1952-58 | Date | 12-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | WORK NAME |
| 2 | Item Description (RUIDP SOR 2023) Providing & Laying XLPE insulated three core Armoured Aluminiumcable for working voltage 33 K.V.(E) confirming IS :7098 P - 2 withH4- Grade electrolytic aluminium conductor confirming to IS: 8130class-2 of purity >99.6 %, Insulation Screening: ExtrudedSemiconducting Compound followed by helically wrapped CopperTape, round / flat strip armouring of cables , Inner / outer sheathPVC type ST-2 confirming to IS:5831 in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have it's own inhouse NABL accrediated Laboratory for testing procedure as perIS:10810 All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR 3 core 300.0 Sq.mm |
| 3 | Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR 3 core 185.0 Sq.mm |
| 4 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 185.0 Sq. mm 3.5 Core |
| 5 | 16.0 Sq. mm 4 core |
| 6 | 70.0 Sq. mm 3.5 core |
| 7 | 25.0 Sq. mm 3.5 core |
| 8 | P / L of Double wall corrugated HDPE pipe confirming to IS : 16205P-24, Stiffness Class 750 N, Externally corrugated and havingsmooth surface inside with HDPE Coupler, Elbow, Tee at requiredDepth below the ground for laying cable of following Nominal Outerdia. MFR Test report from NABL accrediated is to besubmitted.(Excavation of Earth & Back filling with compaction is tobe Paid Extra)All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR 50mm |
| 9 | 90 mm |
| 10 | 200 mm |
| 11 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. including testing etc. as required of following sizes. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .11 KV End Termination Kit Outdoor type 3 core 240/300 Sq.mm 11 KV Straight Through Joint Kit |
| 12 | 3 core 240/300 Sq.mm |
| 13 | 11 KV End Termination Kit Indoor type 3 core 240/300 Sq.mm |
| 14 | 33 KV End Termination Kit Indoor type 3 core 120/150/185 Sq.mm |
| 15 | 33 KV End Termination Kit Outdoor type 3 core 120/150/185 Sq.mm |
| 16 | 33 KV Straight Through Joint Kit 3 core 185/240/300 Sq.mm |
| 17 | Add Extra for Laying of one number XLPE power cable of 11/33 KV (Earthed) voltage grade direct in ground including excavation of trench of size 120 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 18 | Add Extra in Item no.62.3 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same |
| 19 | Supply and fixing of 33 kV pin insulator confirming to IS:731:1971with latest ammendment on existing bracket including allaccessories like MS forged hot dipped GI Pin confirming to IS2486(Part-I)/1993 & IS:2486 (Part-II)/1989 with latest amendment,and as per latest Discom specs. etc. as required. All as per preapproved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR . |
| 20 | Supply of Fabricated 33 KV of 'V' type cross arms as per Discomspecifications made of MS channel 100x50 ISMC (9.5Kg. Per Mtr.)on the existing poles complete including all necessary nut and boltetc with clamps including two coats of Red oxide and two coats ofAluminium paint etc. as Required. All as per pre approved byEngineer in-charge. For additional technical parameters of products/work , refer Annexure \\"A\\" attached with this BSR |
| 21 | Supply and fixing of top hamper as per Discom specifications on theexisting pole complete including nut bolts etc as required. Verticaltype 33 kV. 0.75mtr. IS 75x75x6mm as per tech specs. Of DISCOM(Steel weight 6.5Kg. Approx. per top hamper). All as per preapproved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR |
| 22 | Supply and fixing of 33kV Disc insulator and Hot dipped galvanized Hardware confirming to IS:731:1971 with latest ammendment and as per latest Discom Specs. on existing bracket including all accessories etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR B & S type hardware 120KN |
| 23 | B & S disc insulator 120KN |
| 24 | Supply and installation of spike of M.S. rod 20mm dia 3.0mtr. long for earthing of (tower/pole) drive into earth by mechanical means sturcture connection the spike with cross arm top hamper PCC pole, lattics tower to earth etc. complete as per technical specification of DISCOM |
| 25 | Supplying and drawing overhead steel core Aluminium conductor(ACSR) ISI marked(IS 398 part II-1996) on existing cross armsthrough insulator with all necessary T&P required including bindingand twisting etc. complete in all respect as required. All as per preapproved by Engineer in-charge.For additional technical parametersof product / work refer Annexure 'A' attached with this BSR 100 sqmm of (6/4.72 mm+1/1.57 mm) (Dog) |
| 26 | Supply and fixing of 'V' type cross arms with top hamper and clamps as per latest Discom specifications made of MS angle on the existing poles complete including all necessary nut and bolt, clamps with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 27 | Supply and fixing of 11 kV pin insulator confirming to IS:731:1971 with latest ammendment on existing bracket including all accessories like MS forged hot dipped GI Pin confirming to IS 2486(Part-I)/1993 & IS:2486 (Part-II)/1989 with latest amendment, and as per latest Discom specs. etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 28 | Supply and fixing of 11kV Disc insulator and Hot dipped galvanized Hardware confirming to IS:731:1971 with latest ammendment and as per latest Discom Specs. on existing bracket including all accessories etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR B & S type hardware 45 KN |
| 29 | Supply and fixing of 11 / 33. KV Stay insulator as per IS:5300/1969 and as per Discom's standard specifications etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 110 x 75 x 22mm 11 KV Stay Insulator |
| 30 | 140 x 85 x 25mm 33 KV Stay Insulator |
| 31 | Supply and erection of GI stay set confirming to pattern-1 of BS:16/1974 and as per latest Discom Specifications complete with stay rod with anchor plate fitted with cast iron cross head and steel bow, in cement concrete 1:3:6 including excavation of pit-re-filling etc complete as reqd. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Stay set of dia 20mm, 2.4m long stay rod and anchor plate 380 x 380 x 4.0 mm |
| 32 | Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR |
| 33 | Supply & Laying following size' B ' class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in-charge. (Earth Excavation will be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annex ure \\"A\\" attached with this BSR .150 mm dia |
| 34 | Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) confirming to IS 8309 -1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .185.0 Sq.mm |
| 35 | 300.0 Sq.mm |
| 36 | 16.0 Sq.mm(copper) |
| 37 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 4 pole MCCB With Thermal Magnetic release 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting |
| 38 | 250 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 39 | 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting |
| 40 | Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. 3 pole Power contactors with following AC 3 Rating 185 Amp |
| 41 | 250 Amp |
| 42 | 400 Amp |
| 43 | Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 2 x 16.0 sq.mm |
| 44 | 2 x 25.0 sq.mm |
| 45 | 2 x 70.0 sq.mm |
| 46 | 3.5 x 185.0 sq.mm |
| 47 | 3.5 x 240.0 sq.mm |
| 48 | Supply and fixing of 100 Amp, 11kV Horn gap fuse set IS 9385 onexisting DP structure with 6 nos 24kV/22kV post insulator (IS:5350part III), hot dipped hard ware,fuse wire of required size etc.complete in all respect as per Discom specification etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR |
| 49 | Supply and fixing of 11kV, 400 Amp 3 pole, central pot rotatingdouble break type isolator (IS:9921 part I toV) without earth bladeoperating mechanism with GI spring loaded reverse loop type fixedcontact, solid hard drawn electolytic copper tubular moving contactwith silver/ nickel plated at end points, 9 nos post insulator of 12 kV(IS:2554 & IS 5350 part III), hot dipped galvanising hard ware, nut,bolts etc complete in all respect as per Discom specification etc. asrequired. All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR |
| 50 | Supply and fixing Substation structure for mounting 11/0.4 KvTransformer on Double pole as per DISCOM specification completein all respect as required including nuts and bolts etc (excluding thecost of poles) made of MS channel of 4 nos 100 x 50 x 6mm and 4nos 75 x 40 x 6mm and MS flat 50 x 6mm etc. as required. All as perpre approved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR |
| 51 | Providing and fixing of single pole mounted substation structure setfor isolator / single phase transformer as per DISCOM specificationcomplete in all respect with nuts and bolts as required MS flat 50 x6mm, MS angle 65 x 65 x6mm, MS channel 100 x 50 x 6mm. (Excluding cost of pole ). Etc. as required. All as per pre approved byEngineer in-charge. For additional technical parameters of products/work , refer Annexure \\"A\\" attached with this BSR |
| 52 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 53 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinthleve |
| 54 | Supply and erection of RS joist of 116 x 100 mm, 11 Meter long withthe welded/ bolted top hamper 65 x 65 x 6mm (0.7 Mtr long) makingnecessary arrangement for fixing 11 kV 'V' cross arm, LT bracketand guard wire bracket, grouted in ground 1/6 th of its length andfixed with cement, coarse and grit in 1:3:6 ratio in 1/5th of its length(40cm dia) from the bottom including two coats of aluminium paintover the complete length of joist etc. as required. (Excavation of pitPCC and CC foundation as per Discom specs. to be Paid Extra) Allas per pre approved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR |
| 55 | Supply and erection of GI stay set confirming to pattern-1 ofBS:16/1974 and as per latest Discom Specifications complete withstay rod with anchor plate fitted with cast iron cross head and steelbow, in cement concrete 1:3:6 including excavation of pit-re-fillingetc complete as reqd. All as per pre approved by Engineer incharge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Stay set of dia 20mm, 2.4m long stay rod and anchor plate 380 x380 x 4.0 mm |
| 56 | SITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) , Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated 304 (Non Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for gas tank. Vacum Interrupter of VCB should be RMU Manufacturer’s own make. Each feeder of RMU should have voltage presence indicator and compring of followings:- 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB.- 1 No. Manometer for each tank,- 1 nos. Fault Passage indicator,-Right angle boots for all the feeder Modules All the type test certificates as per IEC from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation / Steel Structure to be paid Extra) All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR Extensible 3 way RMU with 1 no. VCB & 2 No. Load Break Switch |
| 57 | P & Fixing Powder coated CRCA sheet enclosures on existing angle iron frame by means of nuts and bolts and making holes , Din rail etc. as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2.0 mm thick |
| 58 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .Electrolytic grade Aluminium bus bar 6010 grade |
| 59 | Electrolytic grade (Cu-ETP) Tin Coated annealed copper bus bars IACS 100% grade |
| 60 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .8 SWG G.I. ( Hot Dipped ) Wire |
| 61 | Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .25mm x 3mm copper strip |
| 62 | Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 63 | Supply and fixing of 11 KV Outdoor 4 way feeder pillar Box confirming to Discom specifications and made of 3.15 mm thick powder coated CRCA sheet enclosure confirming to IS 14772/IEC 60670 (1989) of Size 1000 mm x 1000 mm x 1500 mm, Both front and rear doors should have 3 heavy duty M.S. hinges with Brass pin inserted inside and locking arrangements.The bottom foundation frame stand should be made from 65x65x6mm MS Angle with four legs of 200mm height provided with 150x150x6mm flats grouted with C.C. of M-10 grade to achieve the height of 2.0 feet above the road level suitable for four outgoing. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR |
| 64 | SITC of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & losses as defined as per 2014 (Fourth Revision) Level-1 . including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect . The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 160KVA |
| 65 | Dismantling of existing LT/HTelectric lines including poles/towers, ACSR conductors, guard wires, stay wire, insulators and other electrical items of the pole coming along the alignment of the road or in the plant premises and removal and transportation as well as disposal of all the items as per the direction of engineer incharge.(Serviceable material or can-dum material.) Dismantling of 11KV Lattice Tower with all accessoriesbrackets, tophamper, chakri, V-Cross arms guard bracket, stay, insulators (pin /disc) etc. |
| 66 | Dismantling of 11KVRail/cement Pole /joist/(RSJ - 9 or 10 mtr height with earth wire and brackets, tophamper, chakri, V-Cross arms guard bracket, stay, insulators (pin /disc) etc |
| 67 | Dismantling and rerolling of 11KV conductor any type |
| 68 | Dismantling and rerolling of LT conductor any type |
| 69 | Dismantling and rerolling of earth conductor any type |
| 70 | Dismantling of the four pole structure with mounted transformersalong with distribution boards G.O, D.O, street light panel, stays,earthing wire pipe, cabling etc & installing the same transformer onthe structure newly erected along with distribution board along witherection, testing and commissioning. |
| 71 | Dismantling and reinstallation of 11KV Feeder pillar box any type |
| 72 | Dismantling of 33KV Lattice Tower (580 kg/450 kg) with allaccessories brackets, tophamper, chakri, V-Cross arms guardbracket, stay, insulators (pin /disc) etc |
| 73 | Dismantling of 33KV Rail /any type of pole with all accessoriesbrackets, tophamper, chakri, V-Cross arms guard bracket, stay,insulators (pin /disc) etc. |
| 74 | Dismantling of LT line pole (PCC - 8/9 mtr height) single phase/3phase & 5 wires bracket, top hamper, insulators(pin or disc)earthwire and conductors. |
| 75 | Dismantling and rerolling of 33KV conductor any type |
| 76 | Labour charges for Dismentling the structure with pole mountedtransformer different capacity along with distribution boards and reerecting the transformer in the structure to be newly erected alongwith distribution boards and erecting testing, testing andcommissioning (as well as cabling) |
| 77 | Labour charges for Dismantling of existing electric poles (PCCpoles, MS channel, Lattic tower 12.6mtr. , 11 mtr. along with theACSR Conductors, 11KV/33KV/LT line etc. 11KV insulator LTinsulator guard wires, staywires and other electric items of the polecoming along the alignment of the road and removal and re- rollingPCC pole, MS channel different sizes as well as handing over thesame to DISCOM store including transportation from site to storeand stacking of dismantling material in store and as per the directionof Engineer Incharge and clean the site good as per the requirementand submit the receipt from DISCOM/ concering authority, includingall complete works |
| 78 | Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discom's specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR LT cross arm 600 mm long with clamp |
| 79 | LT cross arm 1200 mm long with clamp |
| 80 | Supply and fixing of LT porcelain shackle insulator as per IS:1443 1979 and as per Discom's standard specifications, suitable for working voltage 1100 volts including all accessories like GI Hardware fittings confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 75mm x 90mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 9 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender