Tender For Requirement Of Different Proposed Renovation Of Electrical Installation Works For The Beatification, Illumination Of The Wall Arts, Lawn And Lobby Area And Inside Light Fittings Fixtures Etc. At The Premises Of The Circuit House, Barasat,
Tender Overview
Project Description
Tender for Requirement Of Different Proposed Renovation Of Electrical Installation Works For The Beatification, Illumination Of The Wall Arts, Lawn And Lobby Area And Inside Light Fittings Fixtures Etc. At The Premises Of The Circuit House, Barasat, North 24 Parganas.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single corestranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittingsetc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI /PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casing capping and Switch board both on surface] |
| 4 | Average run 8 mtr |
| 5 | Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. with S & F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI / PVC switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface] |
| 6 | On Board |
| 7 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 8 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire [ For Run. Mtr. ] |
| 9 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire [ For Run Mtr. ] |
| 10 | Supplying and fixing PVC casing-capping [Precision Make] on wall,ceiling with saddles and other accessories as required and mending good damages to building works |
| 11 | PVC casing-capping of size 20x12mm |
| 12 | PVC casing-capping of size 25x12mm |
| 13 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. [Make- Gloster/RR Kabel/ Polycab/Finolex or Brand approved by EIC] |
| 14 | 3 x 1.5 sq. mm [ For Run. Mtr. ] |
| 15 | 3 x 2.5 sq. mm [ For Run Mtr. ] |
| 16 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 17 | (i) 1.5 sq mm |
| 18 | (ii) 2.5 sq mm |
| 19 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 20 | 1 or 2 Module (75mmX75mm) |
| 21 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. [ Make - Legrand Myrius/ Honeywell Wraparound MK/ Anchor ROMA Urban ] |
| 22 | 5/6 A switch |
| 23 | 3 pin 5/6 A socket outlet |
| 24 | 15/16 A switch |
| 25 | 6 pin 15/16 A socket outlet |
| 26 | 2 way 5/6 A switch |
| 27 | Bell push |
| 28 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 29 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 30 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 31 | S&F Modular type Indicator lamp |
| 32 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 33 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 34 | 12 Way, Double door |
| 35 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments) [Make- Gloster/RR Kabel/ Polycab/Havells/KEI or Brand approved by EIC] |
| 36 | 2 core 10 Sq. mm |
| 37 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 38 | Upto 35 sq. mm (clamped with 1mm thick shaddle) |
| 39 | Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages as per GS. From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor / pavement /wall etc. |
| 40 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 41 | 2 X 10 sq.mm (19 mm) |
| 42 | Supplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, frequency 50/60 Hz, Operating temp range 0 deg to 40 deg C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection, THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 3000°K, Colour - Warm White and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted.(System lumen efficacy ≥115 lm/Watt) [Make- Philips(signify)/Crompton/Wipro/Osram or Brand approved by EIC] |
| 43 | Twin fittings along with S/F of 2 nos. 18-20 W LED lamps as per specification |
| 44 | Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 45 | Supply & Delivery of 4 foot long 20 watt LED Tube, 230 V AC, 50 Hz, CCT 3000K, THD< 10%, built in 2.5 KV SPD LED Tube, as directed by EIC, Luminious efficacy 100 to 120 Lumen/watt (Colour- Warm White). The LED luminaves & accessories shall have BEE certification. (Make- Philips/Crompton/Wipro/Osram) |
| 46 | Fixing only 4 foot length LED Tube light on the existing Single/Twin LED Tube light fittings suspended from ceiling or fixed on wall. |
| 47 | Installation, Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. [ For Mirror light, 2'x2' LED Recessed/Surface mounted light, Round LED Surface mounted light, Recessed LED Spot light, Photo frame Wall mounted LED Spot light, Linear LED wall mounted light, Track LED wall mounted light ] |
| 48 | S & D of 240 V, 50 HZ, 12 Watt (WW) Surface Mounted Mirror LED Wall light fittings [ Make - Phillips Signify, Model No.- 31403, Muziris Picture Light 12W (WW), Colour - Warm White, CCT 3000K/Crompton or equivalent specifications as per the direction of EIC ] |
| 49 | S & D of 20 Watt Round LED Surface Mounted Full Glow light fittings -- [Make - Philips Signify, Model No.- 582305, 20W Rd Metal Full Glow LED Surface (WW), Colour - Warm White, CCT 3000K/ Crompton or equivalent specifications as per the direction of EIC |
| 50 | S&D of (2' X 2' ) 36 Watt Square LED Panel Light, Surface Mounted , [ Make - Osram, Cat No. - LDECO PANEL 0606 36W 830, Colour - Warm White, CCT 3000K/4000K/Crompton/Phillips/Havells/Wipro or equivalent specifications and S&D of Surface accessory for the arrangement of fixing of the above mentioned fittings [ Make - Osram, Cat No. - LDECO PANEL 0606 surface accessory/Crompton/Phillips/Havells/Wipro or equivalent specifications as per the direction of EIC |
| 51 | S&D of (2' X 2' ) 36 Watt Square LED Light, Recessed Mounted, [ Make - Phillips, Cat No. - RC360B LED 36S, Colour - Warm White, CCT 4000K /Crompton/Havells/Wipro or equivalent specifications as per the direction of EIC |
| 52 | S & D of 240 V, 50 HZ, 1 X 3 Watt LED Recessed mounted Spot light type fittings [ Make - Philips Signify, Model No.- 59145, 3W LED Astra Spot Tiltable, 3W (WW), Colour - Warm White, CCT 3000K/ Crompton or equivalent specifications as per the direction of EIC |
| 53 | S & D of 240 V, 50 HZ, 1 X 3 Watt LED wall mounted Spot type light fittings for photo frame [ Make - Orient, Flexi LED Spot Light with 360 degree Adjustable Arm, Colour - Warm White/Natural White, CCT 3000K/4000K/ Crompton/Phillips/Wipro/Havells/Magik or equivalent specifications as per the direction of EIC |
| 54 | S & D of 240 V, 50 HZ, 20 Watt Magnelite Linear LED wall mounted type light fittings [ Make - Orient, Magnelite Linear, Colour - Warm White/Natural White, CCT 3000K/4000K/Crompton/Phillips/Wipro/Havells/Magik or equivalent specifications as per the direction of EIC |
| 55 | S & D of 240 V, 50 HZ, 20 Watt Magnelite Track LED ceiling mounted type light fittings [ Make - Orient, Magnelite Track light, Colour - Warm White/Natural White, CCT 3000K/4000K/Crompton/Phillips/Wipro/Havells/Magik or equivalent specifications as per the direction of EIC |
| 56 | Fixing of Foot light fitting after cutting the brick wall and concealed in wall as per the size of the fitting incl. necessary arrangements as required as per the direction of E.I.C. [ For Foot lamp of bed room ] |
| 57 | Supply & Delivery of 6 Watt LED Foot Lamp, Make - Crompton, BEACON, Cat No.- LSL - 6 - CDL, Colour - Warm White, CCT 3000K/Philips/Wipro/Havells or equivalent specifications as per the direction of EIC ] |
| 58 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 59 | Fixing only lamp. |
| 60 | Supply of 9 Watt LED lamp to the lamp point. [ Make - PHILLIPS(Signify), Colour - Warm White, CCT 3000K, Lamp Base - B22, Pin type/Crompton or Brand approved by EIC] |
| 61 | Supply of 9 Watt LED lamp to the lamp point. [ Make - PHILLIPS(Signify), Colour - Warm White, CCT 3000K, Lamp Base - E27, Thread type/Crompton or Brand approved by EIC] |
| 62 | Supply of 14 Watt LED lamp to the lamp point. [ Make - PHILLIPS(Signify), Colour - Warm White, CCT 3000K, Lamp Base - E27, Thread type/Crompton or Brand approved by EIC] |
| 63 | S & D of 240 V, 50 HZ, 30 Watt, ORBIT LED Cylinder type light fittings [ Make - Crompton, Cat No.- CDS-200-30-57-SL-NWH, Colour - Warm White, CCT 3000K/ Phillips/Wipro/Orient/Havells/Magik or equivalent specifications as per the direction of EIC |
| 64 | S & D of 240 V, 50 HZ, outdoor type 12 Watt Spike LED light fittings [ Make - Orient, Spike light, Cat No.- LLSL-12-W-V1, Colour - Warm White, CCT 3000K /Crompton/Phillips/Wipro/Havells/Magik or equivalent specifications as per the direction of EIC |
| 65 | Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm thick steel conduit, aluminium cast back plate and brass holder complete, including wiring the down rod with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and painting etc. as required. [ For LED Cylinder type light & Spike LED light ] |
| 66 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% 53 DELHI SCHEDULE OF RATES (E&M)-2025 as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/cexternal connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per equirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 67 | 70 Watt |
| 68 | Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as require |
| 69 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible as per GS. -- |
| 70 | 23 cm (9\\") |
| 71 | Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) |
| 72 | For Aluminum, 23 cm Exhaust fan (9\\") |
| 73 | Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 74 | Dismantling of the existing old unusable electrical installtaion incl. electrical wiring, switch board, fittings-fixtures & other materials by Co's own tools & tackels and shifting & relocate the same at suitable place & mending good the damages by necy. plaster works to these all damaged areas as per the requirement of site situation as per the direction of EIC with 1 no. Semi- skilled and 1 no. Unskilled labour for 3 day. |
| 75 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt).Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) [Make- Philips(signify)/Crompton/Wipro or brand approved by EIC] |
| 76 | 72 Watt |
| 77 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% 53 DELHI SCHEDULE OF RATES (E&M)-2025 as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/cexternal connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per equirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 78 | 200 Watt |
| 79 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40/ 50mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. |
| 80 | Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as require |
| 81 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender