Tender For Reinforcement Of Upula-Ii Old Operable Li Project (River Lift) Under Sss 2026-27 In Kakatapur Block Of Puri District
Tender Value
14.32 Lakhs
Estimated cost
Bid Submission
09 Nov 2026
10 days left
EMD
14322
Bank guarantee accepted
Document Fee
7080
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Puri → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Reinforcement Of Upula-Ii Old Operable Li Project (River Lift) Under Sss 2026-27 In Kakatapur Block Of Puri District
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation of Foundation and plinth in hard soil including dressing and levelling of bed within initial lead of 50mtr.andlifi 1.5mtr etc complete as per the direction of the Engineer-in-charge. |
| 2 | Filling in foundation and plinth with sand including watering and ramming etc complete as per the direction of the Engineer-incharge. |
| 3 | Cement concrite(1:4:8) with 4cm size h.g.b. crusser broken metal of approved quality from approved quarry with ramming watering and curring etc.complete including cost , taxes, royality convence charges of all materials to work site,supply of cement T&P required etc.comelete as per the direction of the Engineer-incharge. |
| 4 | Cement concrite(1:2:4) with 12mm size black Crusher broken chips of approved quality from approved quarry with ramming watering and curring etc.complete including supply of all labours, cost.taxes,royality convence charges of all materials to work site,supply of cement T&P required etc.comelete as per the direction of the Engineer-incharge. |
| 5 | Brick work with flyash Brick 25cm x 12cm x 8cm size having croshing strength not less than 100kg/cm2 to149kg/cm2 with dimensional tolerrance± 8% in cement morter (1:6) in foundation and plinth etc. complete as per the Engineer-incharge. |
| 6 | Brick work with flyash Brick 25cm x 12cm x 8cm size having croshing strength not less than 100kg/cm2 to149kg/cm2 with dimensional tolerrance± 8% in cement morter (1:6) in superstructure work etc. complete as per the Engineer-incharge. |
| 7 | 12mm thick cement plaster in cement morter(1:6)finished smooth to brick work after racking out joints including watering and curring etc.complete including cost.taxes,royality convence charges of all materials to work site,supply of cement T&P required etc.comelete as per the direction of the Engineer-in-charge. |
| 8 | R.C.C worrk for Roof slab of M-20 grade with 20 mm and down grade black hard granite (crushbroken) stone chips including hoisting and laying with centering and shuttering complete. |
| 9 | R.C.C worrk for Lintels and chajja of M-20 grade with 20 mm and down grade black hard granite (crushbroken) stone chips including hoisting and laying with centering and shuttering complete. |
| 10 | R.C.C worrk for Foundation,plinth band and footings bases of column mass concrete pre cast slabsof M-20 grade with 20 mm and down grade black hard granite (crushbroken) stone chips including hoisting and laying with centering and shuttering complete. |
| 11 | R.C.C worrk for beams,columns, of M-20 grade with 20 mm and down grade black hard granite (crushbroken) stone chips including hoisting and laying with centering and shuttering complete. |
| 12 | R.C.C worrk for walls and fins of M-20 grade with 20 mm and down grade black hard granite (crushbroken) stone chips including hoisting and laying with centering and shuttering complete. |
| 13 | Cost of suplying HYSD steel bars for R.C.C. work including Labour charges for cutting, bending,binding,Straightening and laying grills and placing in position including cost of binding wire 18 to 20 gauge |
| 14 | Cement punning over plastering including watering & curing with cost, taxes, royality & conveyance charges of all materials & supply of all materials & T& P etc complte as per direction of Engineer- in - charge. |
| 15 | Filling in foundation and plinth with excavated materials including watering and ramming as directed by the Engineer-incharge. |
| 16 | 2.5cm A.S. flooring with C.C.(1:2:4) including punning with 12mm size chips. |
| 17 | 20 mm thick grading plaster with cement mortar (1:4 ) finished smooth to the roof surface etc complete. |
| 18 | Cost of Double Pannel Door of size (1.05 mx2.00m) made out of M.S.Frame (35mmx35mmx5mm) with G.P.Sheet pannel of 1.20 mm thick and Window of size(0.90mx1.20m) made out of M.S.Frame(30mmx30mmx5mm) with G.P.Sheet pannel of 1.20mm thick including fitting at site with all cost etc. complete as per direction of Engineer in charge. |
| 19 | Finishing walls with water proofing cement paint two coats over a coat of primer of approved shade on new work to give an even shade including cost of cement paint & primer, labour etc complete. |
| 20 | Painting two coats with enamel paint over a coat of red oxide primer for priming over iron work including cost of paint & labour etc complete. |
| 21 | Writing charge of required information and data on both side of the transperancy pillar & pump chamber including supplying of approved paints and required material for writing etc. complete. |
| 22 | Cost of pump chamber wiring with all cost of wiring materials, labour etc complete. |
| 23 | Laying and Fitting of un plasticised 250 mm dia PVC Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non-heat application method including fitting & fixing of required nos. of PVC Teee for outlet & PVC shaddle & PVC raiser, nipple for fitting of air valve, equal Tee etc. complete including conveyance of pipe from factory to work site & testing of pipe line etc complete as per direction of Engineer - in-charge. |
| 24 | Laying and Fitting of un plasticised 200 mm dia PVC Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non-heat application method including fitting & fixing of required nos. of PVC Teee for outlet & PVC shaddle & PVC raiser, nipple for fitting of air valve, equal Tee etc. complete including conveyance of pipe from factory to work site & testing of pipe line etc complete as per direction of Engineer - in-charge. |
| 25 | Labour charges for Instalation of 10 HP pump Sets including fitting , fixing ,Nut and bolt ,Rubber insertion etcof base frame, fitting & fixing suction and delivery pipe to motor,NR Valve, Foot valve, Sluice valve and other fitting materials including cutting, welding and etc. including transportation to project site and site clearance etc. complete as per the direction of the Engineer-incharge. |
| 26 | Fabrication of special joint including cutting and welding of pipes out of M.S. pipe / 100mm dia G.I.pipe including welding charges etc. complete. |
| 27 | Labour for fitting and fixing of G.I/PVC/HDPE outlet Tees along the rising main/lateral pipelines. |
| 28 | Supply of 250mm dia unplasticised riged UPVCpipe ivory in colour having specific gravity of 1.40 to1.46 gms/cc of straight length of 6(six) meter for portable water supplies conforming to IS-4985/2000 of BIS-Amendment-2 read with Table-1 of IS-specification bearingISImarks for working pressure CI-I UPVC pipe to withstand pressure of 2.5kgf/sqcm& the specification and manufacture name should be prominently marked on body of each pipe as per the latest Amendment of IS-4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including including all cost, conveyance, cess etc complete but excluding cost of GST |
| 29 | Supply of 200mm dia unplasticised riged UPVCpipe ivory in colour having specific gravity of 1.40 to1.46 gms/cc of straight length of 6(six) meter for portable water supplies conforming to IS-4985/2000 of BIS-Amendment-2 read with Table-1 of IS-specification bearingISImarks for working pressure CI-I UPVC pipe to withstand pressure of 2.5kgf/sqcm& the specification and manufacture name should be prominently marked on body of each pipe as per the latest Amendment of IS-4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transporation to work site in complete shape and handed over to Pani Panchayat Chairman of Secretary. |
| 30 | 100mm dia nominal bore G.I.pipe having wall thickness 4.5mm electrical resistance welded of medium class confirming to IS- 1239(part-1/2004) with latest ammendments, screwed at both ends as per IS-554 with socketed at one end and the other end protected with plastic threaded protector including its transportation and unloading at L.I.P. site. The socket confirming to ISI 1239(part II/1992) with latest ammendments in random length of 4 to 7 mtr.Each pipe should bear IS certification and manufacturers name/trade mark. |
| 31 | 100mm dia G.I.Bend ( Medium Duty) conforming to IS No-1239 (part II/1992) with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 32 | 100mm dia C.I. Screw boss Foot Valve of swing type friction less with single disc conforming to IS-4038/1979 of reputed brand with ISI mark of reputed company having wide dealership network including all cost, conveyance, cess etc complete but excluding cost of GST |
| 33 | 100mm dia G.I.Flange (Medium Duty) conforming to IS No-6392/1971 with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 34 | 10 HP/7.50 KW Energy efficiency Monoblock pump set of total head 18 mtrs having discharge 1700 LPM with squirrel cage induction motor fitted with bronze impeller TB-2 of IS 318/1981, companion flanges & Class \\"F\\"insulation suitable for operation 415 volt +6%-15% 3 phase, 50Hz AC poweer supply suction/deliveery= 100mmx100mm with BEE 3 Star rated energy efficiency Pump & as per IS-9079/2002 with overall efficiency 62 to 65% of reputed brand having wide dealership net work for easy availability of spares confirming to IS specification (a) Casing: FC 200 as per IS 210/1978 (b) Impeller: Bronze grade LTB-2 of IS 318/1981 including all cost, conveyance, cess etc complete but excluding cost of GST |
| 35 | 100mm dia C.I.Double Flanged Non Return Valve swing type PN-1.0 (IS-5312(Part-I-2004) with bypass arrangement with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 36 | 100mm dia C.I.Sluice Valve Flanged type PN-1.0 as per (IS-14846-2000 Standard) with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 37 | 100X100X25 mm dia G.I.Tee with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 38 | 150X100 mm dia G.I.Reducing Socket with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 39 | 200X150 mm dia G.I.Reducing Socket with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 40 | 250X200 mm dia G.I.Reducing Socket with ISI mark of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 41 | Cost, supplying of 50mm dia Kirloskar make C.I double Air Release Valve PN 1.6 with saddle and Raiser pipe conforming to IS 14845 (SI) with ISI mark including all cost, conveyance, cess etc complete but excluding cost of GST |
| 42 | 200mm dia C.I. Butter Fly Valve BS:5155/15: Kirloskar or equivalent make 13095-CI MOC Lever Operated PN-1.0 with ISI mark of reputed including all cost, conveyance, cess etc complete but excluding cost of GST |
| 43 | Cost of 250 mm dia PVC Bend ( 90* W.P. 10 Kgf/cm2 ) conforming to IS - 4995/ 1988 including all cost, conveyance, cess etc complete but excluding cost of GST |
| 44 | Cost of 200 mm dia PVC Bend ( 90* W.P. 10 Kgf/cm2 ) conforming to IS - 4995/ 1988 including all cost, conveyance, cess etc complete but excluding cost of GST |
| 45 | 250 mm x 200mm Ø PVC Reducing Tee ( W.P. 4 Kgf/cm2 ) conforming to IS - 4995/ 1988 including all cost, conveyance, cess etc complete but excluding cost of GST |
| 46 | 250 mm Ø PVC Coupler( 4 Kgf/cm2 agricultural PVC fitting ) conforming to IS - 4995/ 1988 including all cost, conveyance, cess etc complete but excluding cost of GST |
| 47 | 200 mm Ø PVC Coupler( 4 Kgf/cm2 agricultural PVC fitting ) conforming to IS - 4995/ 1988 including all cost, conveyance, cess etc complete but excluding cost of GST |
| 48 | 250 mm Ø PVC End Cap ( W.P. 10 Kgf/cm2 ) conforming to IS - 4995/ 1988 including all cost, conveyance, cess etc complete but excluding cost of GST |
| 49 | 200 mm Ø PVC End Cap ( W.P. 10 Kgf/cm2 ) conforming to IS - 4995/ 1988 including all cost, conveyance, cess etc complete but excluding cost of GST |
| 50 | 250 mm x250 mm x200mm ØPVC Tee ( W.P. 4 Kgf/cm2 ) conforming to IS - 4995/ 1988 including all cost, conveyance, cess etc complete but excluding cost of GST |
| 51 | 200 mm x200 mm x200mm ØPVC Equal Tee ( W.P. 4 Kgf/cm2 ) conforming to IS - 4995/ 1988 including all cost, conveyance, cess etc complete but excluding cost of GST |
| 52 | Cost, supplying of 200mmx200mmx110mm dia Weldless G.I.Tee (3.6mm thickness) with bend, closing and opening arrangement of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 53 | Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 10 HP with 16 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 8.9 to 13.5 Amp & no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The Starter should provide dependable protection against over load and single phasing fitted with Volt Meter, Ameter, MCB in complete shape including Indicator Lamp reputed brand of ISI specification including all cost, conveyance, cess etc complete but excluding cost of GST |
| 54 | 63 AMP Triple Pole Mainswith confirming to IS No.4064(Part I & II) with ISI marking of reputed company having utilisation capacity cagegory AC- 22 reputed brand of ISI specification including all cost, conveyance, cess etc complete but excluding cost of GST |
| 55 | 4KVAR Power Shunt Capacitor with ISI mark of of reputed approved brand of ISI marked including all cost, conveyance, cess etc complete but excluding cost of GST |
| 56 | Base frame for panel (size 0.40mx0.20m) made with 3 size M.S. channel having suitable holes for fitting of panel Board, coloured with one coat of red oxide primer and two coats of powder coated paint of approved quality & Base frame for motor (size 0.50mx0.27m) made with 3 size M.S. channel having suitable holes for fittings of different size and make 3 phase centrifugal monoblock pump set from 10 HP. to 15 H.P. coloured with one coat of red oxide primer & two coats of powder coated paint of approved quality reputed brand of ISI specification including all cost, conveyance, cess etc complete but excluding cost of GST |
| 57 | Motor hood size (0.45mx0.45mx0.60m) made with 18 SWG (cold rolled M.S.Sheet with one coat of red axide primer and two coats of powder coated paint of approved quality on both side (inside & outside) suitable to cover centrifugal monoblock Pump Set from 10 HP to 15 HP and having provision for attachement with the groves on rear side of the pannel board of approved brand including all cost, conveyance, cess etc complete as per the direction of the Engineer-In-Charge but excluding cost of GST |
| 58 | 3x10 sqmm PVC insulated (HD) tropoder armoured Electric Cable with alluminum conductor for use in 3 phase power system of working voltage upto & including 1100 volts at 50Hz confirming to IS 7098 (Pt-II) of approved brand of ISI marked including all cost, conveyance, cess etc complete but excluding cost of GST |
| 59 | Electrical installation with electrical materials such as PVC tape, Ampere tape, 7/20 PVC copper wire, 3/20 PVC copper wire, GI flexible conduite pipe, No. 6 GI wire, Copper cable socket, GI socket and flange and petty materials required for electrical installation.All materials should be as per IS |
| 60 | Electrical earthing including all materials as per the direction of the Engineer-incharge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender