Civil Aviation Boards / Undertakings / PSU Closing in 12 days TDR #58260445

Tender For Providing Of Runway Guard Light (Rgl) And Turning Pad Lighting At Donyi Polo Airport, Itanagar,Arunachal Pradesh

Issued by Boards / Undertakings / PSU · Papum Pare, Arunachal Pradesh
Tender Value
3.57 Crore
Estimated cost
Bid Submission
28 Nov 2026
12 days left
EMD
8.44 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Papum Pare → Arunachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing Of Runway Guard Light (Rgl) And Turning Pad Lighting At Donyi Polo Airport, Itanagar,Arunachal Pradesh

BOQ

Name of Work:- Providing of Runway Guard Light (RGL) and Turning Pad Lighting at Donyi Polo Airport, Itanagar,Arunachal Pradesh
Sl. No. Item Description
1Supply of unidirectional LED inset fitting with green filters for Turnpad light (straight line & Curve) of turnpad marking applications suitable for use in 6.6A airfield lighting circuits normally supplied from 15/45W isolating transformer and complete with lens support mechanism, lens clamping mechanism, gaskets, one cable lead of two pin secondary, including shallow base other accessories etc. complete as required meeting the requirement of ICAO Annex -14 and Aerodrome Design Manual part - IV amended upto date.
2Installation, testing and commissioning of inset type Turning Pad fittings including shallow box & all accessories in the bitumen/ concrete surface using core cutting machine and filling the groove with Dobefil 60 compound & Hardener 758 as required, installation and aligning of inset fitting using suitable jig, closing of shallow base with sealant material, connecting with secondary leads, providing Insulation tape etc. as required.
3Supply of elevated type high intensity each guard light fitting with 02 Nos. LED luminaires in , wig-wag unidirectional yellow with plastic cover tube, sun shield/visor, T bar with breakable coupling, base plate with 6 nos of M-10 stainless steel bolts, spring washers and all other accessories, suitable flasher unit, lenses & filters and with all standard hardware and accessories ready for site installation and as per ICAO requirement suitable for operation with CCR of suitable rating complete as required. (Make: As per list of preferred make meeting ICAO requirement for ISO CANDALA as specified in Annex- 14.)
4Installation, testing and commissioning of Runway Guard Light fittings on the existing transformer housing boxes including installation of isolating transformers, lens, filters, lamps and other accessories, alignment, levelling and making secondary lead connections to transformer & fittings, making earth connections etc. complete as required.
5Supply of CI isolating transformer housing box,water tight round type, metal container of outside dia 330mm, height 450mm made of 10mm thick cast iron moulding all round, except the top surface which is 15 mm thick, cast iron moulding suitable to receive light fitting base plate on the top and having a clear hole on one side surface with centre 75 mm above bottom to receive 50mm dia 'B' class GI pipes with check nuts as required. The box should have 2 nos SS earth bolts M10x30mm tapped inside near the hole (4” away from the hole centre) and having a drain hole at the bottom tapped to receive 15 mm dia B class GI pipe and having clear opening of 220 mm at the top surface and 6nos M10 tapped hole as per specifications as required.Single hole
6Installation of transformer housing box for elevated type runway guard light fittings in concrete runway/taxiway shoulder with the top of the box at 20-25mm above the FFL by core cutting the runway/taxiway shoulder with suitable machine tool for the required size for fixing the housing box (cutting dimension 430-440mm dia x 550-560mm depth approx) with a base concrete of 1:2:4 of size 430-450 mm x 100 mm thick, all round concrete of 1 : 2 : 4 of minimum 50 mm thick, alignment of box, fixing the box by using quick setting sealant compound such as plasticised sulphur cement / dobfil compound etc. making good the runway/taxiway to the original shape and strength, etc complete as required.
7Installation of CI housing box of size 330 mm dia and depth up to 450 mm as per drawing i/c excavation of hard rock/all kinds of soil to the required depth, as per specifications, refilling the side surface, sloping and making good the same as original, providing cement concrete foundation of ratio 1:3:6 ( 1 cement, 3 coarse sand and 6 graded stone of 40 mm nominal size) & thickness of concrete at 75 mm in all sides i/c bottom dressing of earth, with brick and finishing with 13 mm thick cement plaster of ratio 1:3 on exposed surface and neat cement finishing on top etc. as required.
8Supply of microprocessor based 4 KW CCR with 5 step intensity suitable for use with LED Elevated Runway Guard Light /Turn pad lights.
9ITC of 4 KW Indoor Type Microprocesor based Air Cooled Constant Current Regulator (CCR)
10Supply of 5 KV grade PVC insulated, PVC sheathed, single core, unarmoured, stranded copper conductor, anti-termite and anti-rodent treated UG cable confirming to IS 1554-Part-II as amended up to date and as per enclosed specifications for use in Airfield Lighting of the following size:1C x 6 sq mm
11Laying of one number 5 KV grade PVC insulated, PVC sheathed, single core, unarmoured, stranded copper conductor underground Airfield Lighting cable of following size in the existing RCC/HUME/METAL/DWC HDPE/HDPE Pipe as required. 6 or 16 Sqmm
12Laying of one number 5 KV grade PVC insulated, PVC sheathed, single core, unarmoured, stranded copper conductor underground Airfield Lighting cable of following size in the existing masonary open duct as required. 6 or 16 Sqmm
13Supply of 2C x 4 Sq.mm AFL secondary lead of following length provided with 2 pin male connector at one end(in metres).20 Mtr
14Supply of 2C x 4 Sq.mm AFL secondary lead of following length provided with 2 pin male connector at one end(in metres).25 Mtr
15Supply of 2C x 4 Sq.mm AFL secondary lead of following length provided with 2 pin male connector at one end(in metres).30 Mtr
16Supply of 2C x 4 Sq.mm AFL secondary lead of following length provided with 2 pin male connector at one end(in metres).35 Mtr
17Supply of 2C x 4 Sq.mm AFL secondary lead of following length provided with 2 pin male connector at one end(in metres).40 Mtr
18Supply of 2C x 4 Sq.mm AFL secondary lead of following length provided with 2 pin male connector at one end(in metres).45 Mtr
19Making groove for laying of secondary cable with kerf cutting machine in taxiway/runway of PQC/bituminous surface of suitable depth and width, laying of cable in the groove with backer rods at top and bottom, filling and sealing the cut to pavement level by suitable sealing material etc complete as required as per the direction of Engineer In Charge.Up to 2 No. Secondary cable of size 2Cx4 sq.mm.
20Supply of 5 KV grade 50Hz series type isolating transformers following capacity and type of fittings/lamp lights encapsulated in polyester resin finally mould in neoprene type rubber with primary & secondary connections and ready to install etc. complete as required(as per List of makes attached herewith).15/45W 6.6/ 6.6 A
21Supply of 5 KV grade plug and receptacle of type I class \\"B\\" connector suitable for field attachment with 5 KV grade of 6 Sq.mm PVC insulated PVC sheathed single core copper conductor cable conforming to the relevant IS specification etc. complete as required(as per List of makes attached herewith).
22Making field connection by crimping 6/16 sqmm plug and receptacle on single core 6/16 sqmm copper conductor cable in an approved manner including applying HT tape etc. as reqd.
23Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930 Part II complete with fitting and cutting, jointing etc direct in ground (75cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
24Providing and fixing 6 SWG dia G.I. wire on surface/in recess / in existing RCC/HUME/METAL/DWC HDPE/HDPE Pipe for loop earthing as required.
25Supply and fixing of MS base plates of 10mm thick, 330 mm dia provided with 6 nos holes for M-10 SS bolts, for covering the CI transformer housing box including providing gaskets, and SS bolts etc. complete as required
26Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of EIC: bituminous road / concrete
27Numbering of Taxiway/ Runway light fittings serially with ISI marked enamel paint with double coat, yellow paint as background and numbering with black paint for suitable size etc., complete as required.
28Supplying and making cable route marker with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm. nominal size) of size 60 cm. x 60 cm. at the bottom and 50 cm. x 50 cm. at the top with a thickness of 10 cm. including inscription duly engraved as required.
29Earthing with G.I. earth pipe 4.5 m long x 40 mm dia. including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe,charcoal,salt etc. complete as required.
30Modification of existing remote control desk for operation of the air field lighting system, including providing connections for the operating the below mentioned Airfield Lighting Circuits, incorporating changes in the mimic panel using suitable LEDs to accomodate the system/orientation changes at field, providing required control/selector switches, labelling the same etc. complete as required(Existing Make:NASU).
31Supply and Laying 100 mm dia Class B GI pipe in concrete/bitumen road by cutting the concrete/bitumen and finish/Making good the surface with 1:2:4 Cement Concrete Etc as required
32Cleaning of mud/slush or any other materials inside Hume pipe/manhole in runway/taxiway crossing for laying of cable using suitable method without damaging existing laid cables.(laying of cable excluded)
33Carrying out Photometric test for each fitting installed as per CAR/ICAO specifications and submission of reports ofTurn Pad light
34Supply of following sizes of XLPE insulated copper conductor(solid conductor) armoured control cable conforming to IS 7098 (Part-I) amended upto date.16Cx2.5 Sqmm
35Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
36Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 35 Sq. mm in the existing HDPE/RCC/ HUME/ STONEWARE/ METAL pipe as required.
37Laying and fixing of one number PVC insulated PVC sheathed/XLPE power cable of 1.1 KV grade of following size on cable tray as requiredUpto 35 Sqmm (Clamped with 1mm thick saddle)
38Laying and fixing of one number PVC insulated PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 Sqmm (Clamped with 1mm thick saddle)
39Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonary open duct as requiredUpto 35 Sqmm
40Supplying and making end termination with brass compression gland and aluminium lugs for following size for PVC/ XLPE insulated and PVC sheathed armoured Copper conductor cable of 1.1. KV grade as required : 16C x 2.5 sq.mm.
41Providing and fixing following rating and breaking capacity and 4 pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. 63A 4 pole,25kA Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58260445
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 3.57 Crore
LAST DATE 28-11-2026
Authority
Authority Name Airports Authority Of India
Work Description Tender for Providing Of Runway Guard Light (Rgl) And Turning Pad Lighting At Donyi Polo Airport, Itanagar,Arunachal Pradesh
Basic Detail
Tender No AAI/HGI/GL TP lights/ 2026-27
Bidding Type Tender
Location
City Papum Pare
State Arunachal Pradesh
Key Dates
Publish Date 29 Oct 2026
Submission Date 28 Nov 2026
Open Date 30 Nov 2026
Finance
Tender Value 3.57 Crore
Tender Fee 1180
EMD 8.44 Lakhs
Exemption Not Available
Document List
3bbbf691-e86e-481f-bf05-a3c320fe5be1.html
BOQ_345045.xls
TenderDoc.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Nov 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

3bbbf691-e86e-481f-bf05-a3c320fe5be1.html

xls

BOQ_345045.xls

pdf

TenderDoc.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender