Tender For Supply, Installation, Testing and Commissioning A C Machine And Allied electrical installation Work At System Officer Server Room At Dist Court Complex Krishnagar, Nadia (Job No.Ned/Kng/Ow/07/01 Of 26-27).
Tender Value
1
Estimated cost
Bid Submission
13 Nov 2026
13 days left
EMD
4678
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nadia → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Installation, Testing and Commissioning A C Machine And Allied electrical installation Work At System Officer Server Room At Dist Court Complex Krishnagar, Nadia (Job No.Ned/Kng/Ow/07/01 Of 26-27).
BOQ
| Sl. No. | Item Description |
| 1 | Sub Head -1 Bus Bar,TPN,VTPN,MAIN SWITCH |
| 2 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.(Ava 5mtr)[Page no E24/Item No1(a)]. |
| 3 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. |
| 4 | 4 Way Enclosure(607715) [14/D-10] (Legrand /Schnider/ Siemens Make) |
| 5 | 63A FP Isolator ( Legrand /Schnider/ Siemens Make) |
| 6 | 6-32A SP [7/D-6] . ( Legrand /Schnider/ Siemens Make) |
| 7 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. |
| 8 | 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC (From TPN to Computer point & From TPN to Power plug) [1sf/E-9] |
| 9 | 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC ECC(From TPN to AC Plug) [1sf/E-9] |
| 10 | 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC |
| 11 | SUB-HEAD 2-- PLUGS & SOCKETS |
| 12 | Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS(16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.[ page no E-7 /Item no 23]. |
| 13 | Supplying & Fixing Industrial Plug & Socket board with 415 V, 30A, TPN & Earth Metal Industrial Plug socket & 30A Industrial top incl. S&F 32 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection.[Page no D12/Item no 18]. |
| 14 | SUB-HEAD 3 AC EI work |
| 15 | Supply & Fixing 240 V, 21 -30 A 1phase OLP3+ Air conditioner starter and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.( Only for the 1 Ph AC).[NS] |
| 16 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Make- Legrand-Arteor / Schneider- Zencelo / Crabtree - Murano / L & T- Englaze) & necy.connections ( Only for the 1 Ph AC).[NS] |
| 17 | Supply & Delivery of 240V, 20 & 10 Amp 5 in 1 combined Socket (Ancho Neo capton 4 fixing hole,code-38590) .[NS] |
| 18 | Supply & Delivery 240 V,50 Hz, Metal body Heavy duty Exhaust fan of following sizes and RPM (Make -- EPC) |
| 19 | 9\\" (23 cm)1370 RPM |
| 20 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following dia incld. Supply & Fixing Al louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) |
| 21 | 9\\" (23 cm) |
| 22 | Supply & Delivery of 240V,1400 mm celling fan with safety wire and P 2 capacitor.( Make Usha -Striker/or equivelent). |
| 23 | Supplying & Delivery 4 feet single commercial LED type fluorescent light fittings complete with all accessories with 1 x 20 Wt.Master LED Tube lamp similar to Philips make cat No. TMC-501 P 1xTLED 22 WP3241 corresponding to Wipro / Bajaj / Crompton ) |
| 24 | S&F AC machine timer for one no. machine febricated with double door 14Way SPNDB as per L&T/Legrand) i) 240 V, 32A DP MCB of breaking capacity 10KA & ''C'' Charecteristic (L&T)-1no ii) 32A TP power contactor with 220 coil voltage (L&T, Cat no-MNX32-2P, CS90238)-1 No. iii) Digital timer switch (L&T, cat no-Crono 67DDTO)-1no. [N/S] |
| 25 | SUB-HEAD 4 -- EARTHING |
| 26 | Excavation of soil for installation of Earth Electrode and filling & ramming For Soft Soil [1(a)/G-1] |
| 27 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: |
| 28 | By ISI-Medium GI pipe . [2(a)/G-1] |
| 29 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [4(a)/G-2]. |
| 30 | Earth Continuity Conductor : Solid GI wire |
| 31 | No. 4 SWG |
| 32 | SITC of 1.5 Ton Split type A.C. machine having the following specification & feutures:- a) Star Rating -3 star b) Rated Voltage-230 V + / -5%, Frequency -50 Hzc) Compressor type- Rotaryd) Refrigrant: R-410A/R-32e) Cordless Remote Arrangement with all modernized provision of temperature setting , Fan speed option ( Low/Medium /High ) Auto Swing f) Out door operating Temperature:-50c (Minimum)g) PCB control unit of indoor unit should be covered by metalic enclosure. ( Make- OGeneral :SPLIT AC -1.5 Ton ASGG18CETB-B(R32) /Daikin/ Mitshushi Heavy Electrical). incl 3 mtr connecting kit. |
| 33 | SITC of 2.5 Ton Split type A.C. machine having the following specification & feutures:- a) Star Rating -3 star b) Rated Voltage-230 V + / -5%, Frequency -50 Hzc) Compressor type- Rotaryd) Refrigrant: R-410A/R-32e) Cordless Remote Arrangement with all modernized provision of temperature setting , Fan speed option ( Low/Medium /High ) Auto Swing f) Out door operating Temperature:-50c (Minimum)g) PCB control unit of indoor unit should be covered by metalic enclosure. ( Make- OGeneral :SPLIT AC -2.5 TR ASGC30CETB-B(R-32) /Daikin/ Mitshushi Heavy Electrical). incl 3 mtr connecting kit & drain pipe. |
| 34 | S&F 15.88mm & 6.35mm copper pipe with keno foam insulation & 3/4core 2.5 Sqmm copper un aurmored cable. [ for connection of plug socket to out door unit & out door to indoor unit] |
| 35 | S & F 19mm PVC flexible drain pipe. |
| 36 | Add GST % 18% |
| 37 | Add CESS % 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysNov 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender